CODE SUMMARY
SCOPE OF WORK
MERCANTILE BUILD OUT
PREVIOUS USE OF SPACE
SHELL SPACE
OCCUPANCYCLASSIFICATION
MERCANTILE
CHANGE OF OCCUPANCY CIASS2
NO
TOTAL BUILDING AREA
VARIES SF/FLOOR
X
1 5STORIES
=
142.394 SF
TOTAL PROJECT AREA
2,311 SF
SPACE TYPE AREA SF PER OCCUPANT OCCUR LOAD
OCCUPANCY CALCULATIONS
N UMBER OF EXITS
MERCANTILE
2,311 SF
30
78
TOTAL OCCUPANTS IN PROJECT AREA 78
REQUIRED:2 PROVIDED:3
SPRINKLER SYSTEM( YES/NO(
YES
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
7,268 SF (DOES NOT INCLUDE PARKING GARAGE AREA(
ACCESSORY AREA EXCEEDS 10%
NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED(
ALL EXISTING FIRE WALLS TO REMAIN
ASHRAE 90.1 SUMMARY
REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN(
BUILT BEFORE 1978?
NO
BUILDING CONSTRUCTION TYPE
IILB
TRAVEL
TRAVEL
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City d Camel
�VT�SJtDN�(1DJLAK
DATE: 10/15/19
AREA NOT IN CONTRACT
AREA OF WORK
LEGEND
Ep EXISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXIT
�IQ
FIRE EXTINGUISHER
EXIT SIGN -LED EDGE LIT
4®
®
EMERGENCY LIGHT
— — —
TRAVEL DISTANCE
LIFE SAFETY NOTES
I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES(,
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM 8 DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA(. IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE.
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE,
WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR
THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER
SYSTEM.
5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED
DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED
DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING
JURISDICTION OVER THE PROJECT.
GENERAL NOTES
LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
LIFE SAFETY PLAN
0 4' 8' 16,
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOTTO BE
(USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCHOIT DESIGN.
ER
V
Z
W
w
Wc2
caLnry
P—
+
LU
U
�~
LJ
LEE
Z
N
W
Z
REVISIONS
MARld DATE I DIS SCRIPTION
IN 0.
AR10700017
STATE OF
PROJECT NUMBER
2019.308
DRAWN BY
NP
1ST FLOOR
LIFE SAFETY
L 100