HomeMy WebLinkAboutL100 Life Safety2 3 4 5 6 7 B 9 10 11 12 13 14 15 16 CODE SUMMARY SCOPE OF WORK MERCANTILE BUILD OUT PREVIOUS USE OF SPACE SHELL SPACE OCCUPANCYCLASSIFICATION MERCANTILE CHANGE OF OCCUPANCY CIASS2 NO TOTAL BUILDING AREA VARIES SF/FLOOR X 1 5STORIES = 142.394 SF TOTAL PROJECT AREA 2,311 SF SPACE TYPE AREA SF PER OCCUPANT OCCUR LOAD OCCUPANCY CALCULATIONS N UMBER OF EXITS MERCANTILE 2,311 SF 30 78 TOTAL OCCUPANTS IN PROJECT AREA 78 REQUIRED:2 PROVIDED:3 SPRINKLER SYSTEM( YES/NO( YES TOTAL AREA OF ACCESSORY USES 0 SF TOTAL AREA ON THE FLOOR 7,268 SF (DOES NOT INCLUDE PARKING GARAGE AREA( ACCESSORY AREA EXCEEDS 10% NO FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED( ALL EXISTING FIRE WALLS TO REMAIN ASHRAE 90.1 SUMMARY REQUIREMENTS WILL BE MET (SEE REFLECTED CEILING PLAN( BUILT BEFORE 1978? NO BUILDING CONSTRUCTION TYPE IILB TRAVEL TRAVEL RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City d Camel �VT�SJtDN�(1DJLAK DATE: 10/15/19 AREA NOT IN CONTRACT AREA OF WORK LEGEND Ep EXISTING ELECTRICAL PANEL LOCATION EX EXISTING EXIT �IQ FIRE EXTINGUISHER EXIT SIGN -LED EDGE LIT 4® ® EMERGENCY LIGHT — — — TRAVEL DISTANCE LIFE SAFETY NOTES I. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY. 2. PROVIDE ALARM NOTIFICATION APPLIANCES (HORNS/STROBES(, EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY OTHER REQUIRED ALARM 8 DETECTION SYSTEMS AS NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA(. IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE, WORKING SYSTEM. SCHOTT DESIGN, INC., IS NOT RESPONSIBLE FOR THE DESIGN, INSTALLATION, OR RENOVATION OF THE FIRE SPRINKLER SYSTEM. 5. THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND RELATED DOCUMENTS, WITH THE STATE AND LOCAL AUTHORITIES HAVING JURISDICTION OVER THE PROJECT. GENERAL NOTES LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION DETAILS. LIFE SAFETY PLAN 0 4' 8' 16, THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOTTO BE (USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCHOIT DESIGN. ER V Z W w Wc2 caLnry P— + LU U �~ LJ LEE Z N W Z REVISIONS MARld DATE I DIS SCRIPTION IN 0. AR10700017 STATE OF PROJECT NUMBER 2019.308 DRAWN BY NP 1ST FLOOR LIFE SAFETY L 100