Loading...
HomeMy WebLinkAboutA111 Deconstruction & Architectural Floor PlanDECONSTRUCTION LEGEND EXISTING TO BE REMOVED EXISTING TO REMAIN WALL WALL mmmmmm PARTIAL HEIGHT WALL � PARTIAL HEIGHT WALL ' T DOOR AND FRAME =t—t= WINDOW / SIDELIGHT 1 ----- j CEI LING GRID AND TILES, 2'A I I CEILING GRID AND i--?--r TILES, 2'x2' F'T I i'I SUPPLY AIR DIFFUSERS caul 1 LIGHT FIXTURE, LL __ Jj FLUORESCENT, 2k4' IF LIGHT FIXTURE, 11 La& FLUORESCENT, 2'x2' X( LIGHT FIXTURE, CAN Fc� LIGHT FIXTURE, TRACK 7.14 LIGHT FIXTURE, SCONCE LIGHT FIXTURE, PENDANT $ LIGHTSWITCH F4y^ EXIT LIGHT ELECTRIC OUTLETS) 1�;lo;Ia; DATA OR b COMMUNICATION OUTLET 7 DOOR AND FRAME x WINDOW/SIDELIGHT NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. ® AREA NOT IN CONTRACT RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel ja MG� DATE: 10/15/19 DECONSTRUCTION PLAN 0 2' 4' 8' 16, WALL TYPES NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL. ALL WALLS ARE TO BE I UNLESS OTHERWISE NOTED, PROVIDE MOISTURE RE I TANT / GREEN BOARD AS REQUIRED IN RESTROOM AND/OR SHOWER ROOMS. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS. H DEMISING WALL TO DECK WITH INSULATION 3558" METAL STUDS AT 16" O.C.; ONE LAYER OF X'TYPE"X'GYPSUM BOARD 1fU Ul r�, EACH SIDE; EXTEND WALL TO UNDERSIDE OF DECK; FIBERGLASS SOUND BATT INSULATION INSIDE WALL 9 BURR OUT EXISTING WALL ZJ METAL STUDS AT 16" O.C.; ONE LAYER OF s% TYPE "XGYPSUM BOARD; EXTEND WALL TO UNDERSIDE OF DECK ® AREA NOT IN CONTRACT ❑ AREA OF WORK ARCHITECTURAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN W4 WALL ® PARTIAL HEIGHT WALL a� WINDOW/SIDELIGHT DOOR AND FRAME (SEE DOOR SCHEDULE) WALL ® PARTIAL HEIGHT WALL a~¢ WINDOW/SIDELIGHT 7 DOORANDFRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. PLAN NOTES A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. NEW FIRE EXTINGUISHER AND RECESSED CABINET TO BE PROVIDED A02 AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. A03 COORDINATE EXACT MILLWORK DETAILS WITH MILWORK CONTRACTOR AND TENANT. A04 DRYWALL TO BE FINISHEDABOVE WINDOWS WHERE PERIMETER OF EXPOSED CEILING MEET. A05 SHELVES TO BE PROVIDED BY OTHERS. COORDINATE WITH TENANT. P01 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. OPROVIDE COLD WATER SUPPLY AND WATER LINES AS REQUIRED P02 FOR NEW TOILETS. OPROVIDE 4-COMP SINK, HAND WASH SINK AND MOP SINK IN THIS P03 ROOM. PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE AND VENT PIPING FOR SINKS. COORDINATE LOCATIONS WITH TENANT. ARCHITECTURAL PLAN 0 2' 4' 8' 16' ■ " IIIIIINI N Q 0q N O a8U E n Z ^' L � 0Ia� P Q^ w O M N O � Q QC C THIS DRAWING, AND TEE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN. ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE (USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOUT THE WRITTEN CONSENT OF SCH07 DESIGN. CV M O E U z W W Wow In LO r Q + uJ U ZHW W Z W CL J W LJO 14e:t REVISIONS MARIO DATE I DB )DESCRIPTION IN 0. AR10700017 STATE OF PROJECT NUMBER 2019.308 DRAWN BY NP 1ST FLOOR DECONSTRUCTION/ ARCHITECTURAL FLOOR PLAN A111