HomeMy WebLinkAboutA111 Deconstruction & Architectural Floor PlanDECONSTRUCTION LEGEND
EXISTING TO BE REMOVED EXISTING TO REMAIN
WALL
WALL
mmmmmm PARTIAL HEIGHT WALL � PARTIAL HEIGHT WALL
' T DOOR AND FRAME
=t—t= WINDOW / SIDELIGHT
1 ----- j CEI LING GRID AND
TILES, 2'A
I I CEILING GRID AND
i--?--r TILES, 2'x2'
F'T
I i'I SUPPLY AIR DIFFUSERS
caul
1
LIGHT FIXTURE,
LL __ Jj
FLUORESCENT, 2k4'
IF
LIGHT FIXTURE,
11
La&
FLUORESCENT, 2'x2'
X(
LIGHT FIXTURE, CAN
Fc�
LIGHT FIXTURE, TRACK
7.14 LIGHT FIXTURE, SCONCE
LIGHT FIXTURE,
PENDANT
$ LIGHTSWITCH
F4y^ EXIT LIGHT
ELECTRIC OUTLETS)
1�;lo;Ia;
DATA OR
b COMMUNICATION
OUTLET
7 DOOR AND FRAME
x WINDOW/SIDELIGHT
NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
® AREA NOT IN CONTRACT
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Camel
ja MG�
DATE: 10/15/19
DECONSTRUCTION PLAN
0 2' 4' 8' 16,
WALL TYPES
NOTE:
ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL.
ALL WALLS ARE TO BE I UNLESS OTHERWISE NOTED,
PROVIDE MOISTURE RE I TANT / GREEN BOARD AS REQUIRED IN
RESTROOM AND/OR SHOWER ROOMS.
NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS
PROJECT. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
H DEMISING WALL TO DECK WITH INSULATION
3558" METAL STUDS AT 16" O.C.;
ONE LAYER OF X'TYPE"X'GYPSUM BOARD 1fU Ul r�,
EACH SIDE; EXTEND WALL TO UNDERSIDE OF
DECK; FIBERGLASS SOUND BATT INSULATION
INSIDE WALL
9 BURR OUT EXISTING WALL
ZJ METAL STUDS AT 16" O.C.;
ONE LAYER OF s% TYPE "XGYPSUM BOARD;
EXTEND WALL TO UNDERSIDE OF DECK
® AREA NOT IN CONTRACT
❑ AREA OF WORK
ARCHITECTURAL LEGEND
NEW CONSTRUCTION EXISTING TO REMAIN
W4
WALL
®
PARTIAL HEIGHT WALL
a� WINDOW/SIDELIGHT
DOOR AND FRAME
(SEE DOOR SCHEDULE)
WALL
® PARTIAL HEIGHT WALL
a~¢ WINDOW/SIDELIGHT
7 DOORANDFRAME
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
GENERAL NOTES
I. SEE ELECTRICAL PLAN FOR INTENDED FURNITURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4 OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS.
PLAN NOTES
A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
NEW FIRE EXTINGUISHER AND RECESSED CABINET TO BE PROVIDED
A02 AND INSTALLED BY CONTRACTOR. ALL FIRE EXTINGUISHERS ARE
TO BE INSTALLED ACCORDING TO NFPA 10.
A03 COORDINATE EXACT MILLWORK DETAILS WITH MILWORK
CONTRACTOR AND TENANT.
A04 DRYWALL TO BE FINISHEDABOVE WINDOWS WHERE PERIMETER OF
EXPOSED CEILING MEET.
A05 SHELVES TO BE PROVIDED BY OTHERS. COORDINATE WITH TENANT.
P01 PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
AND VENT PIPING FOR SINKS.
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
OPROVIDE COLD WATER SUPPLY AND WATER LINES AS REQUIRED
P02 FOR NEW TOILETS.
OPROVIDE 4-COMP SINK, HAND WASH SINK AND MOP SINK IN THIS
P03 ROOM. PROVIDE POTABLE HOT AND COLD WATER AND SANITARY
WASTE AND VENT PIPING FOR SINKS. COORDINATE LOCATIONS
WITH TENANT.
ARCHITECTURAL PLAN
0 2' 4' 8' 16'
■ " IIIIIINI
N
Q 0q
N O
a8U
E
n Z ^'
L �
0Ia�
P Q^
w O M N
O � Q
QC
C
THIS DRAWING, AND TEE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
(USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
CV
M
O
E
U
z
W
W
Wow
In
LO
r
Q
+
uJ
U
ZHW
W
Z
W
CL
J
W
LJO
14e:t
REVISIONS
MARIO DATE I DB )DESCRIPTION
IN 0.
AR10700017
STATE OF
PROJECT NUMBER
2019.308
DRAWN BY
NP
1ST FLOOR
DECONSTRUCTION/
ARCHITECTURAL
FLOOR PLAN
A111