Loading...
HomeMy WebLinkAboutZurn 975XL2 - BackFlowPage 1 of 2 Zurn Industries, LLC | Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Rev. G Date: 2/19 Document No. BF-975XL2(LG) Product No. Model 975XL2(LG) Model 975XL2 Reduced Pressure Principle Assembly Application Ideal for use where Lead-Free* valves are required. Designed for installation on potable water lines to protect against both backsiphonage and backpressure of contaminated water into the potable water supply. Assembly shall provide protection where a potential health hazard exists. Standards Compliance • ASSE® Listed 1013 • IAPMO® Listed • CSA® Certified B64.4 • AWWA Compliant C511 • Approved by the Foundation for Cross Connection Control and Hydraulic Research at the University of Southern California • Meets the requirements of NSF/ANSI 61* *(0.25% MAX. WEIGHTED AVERAGE LEAD CONTENT) • UL® Classified (less shut-off valves or with OS&Y valves) • C-UL® Classified Materials Main valve body Low Lead Cast Bronze ASTM B 584 Access covers Low Lead Cast Bronze ASTM B 584 Fasteners Stainless Steel, 300 Series Elastomers Silicone (FDA Approved) Buna Nitrile (FDA Approved) Polymers Noryl™ Springs Stainless Steel, 300 series Ball valve handles Stainless Steel Features Sizes: 3/4", 1", 1-1/4", 1-1/2", 2" Maximum working water pressure 175 PSI Maximum working water temperature 180°F Hydrostatic test pressure 350 PSI End connections Threaded ANSI B1.20.1 Relief Valve discharge port: 3/4” - 1” - 0.63 sq. in. 1 1/4” - 2” - 1.19 sq. in. Dimensions & Weights (do not include pkg.)AB G CD F E OPTIONAL LEAD-FREE STRAINER (MODEL SXL)975XL2WILKINS ZURN WILKINS XLOptions (Suffixes can be combined) … - with full port QT ball valves (standard) …S - with bronze "Y" type strainer …FT - with integral male 45° flare SAE test fitting …TCU - with test cocks up …SE - with street elbows (3/4" & 1") …U - with union ball valves Accessories …Air gap (Model AG) …Repair kits (rubber only) …Thermal expansion tank (Mdl. XT) …Soft seated check valve (Model 40XL2) …Shock arrester (Model 1260XL) …QT-SET Quick Test Fitting Set …Ball valve handle locks …Test Cock Lock (Model TCL24) MODEL SIZE DIMENSIONS (approximate) WITH BALL VALVESABCDEFG in.mm in.mm in.mm in.mm in.mm in.mm in.mm in.mm lbs.kg 3/4 20 12 305 7 3/4 197 2 1/8 54 3 76 3 1/2 89 5 127 16 1/8 410 12 5.5 1 25 13 330 7 3/4 197 2 1/8 54 3 76 3 1/2 89 5 127 17 3/8 441 14 6.4 1 1/4 32 17 432 10 15/16 278 2 3/4 70 3 1/2 89 5 127 6 3/4 171 22 9/16 573 28 12.7 1 1/2 40 17 3/8 441 10 15/16 278 2 3/4 70 3 1/2 89 5 127 6 3/4 171 24 1/16 611 28 12.7 2 50 18 1/2 470 10 15/16 278 2 3/4 70 3 1/2 89 5 127 6 3/4 171 26 1/2 673 34 15.4 NSF/ANSI 61 Zurn Industries, LLC | Wilkins 1747 Commerce Way, Paso Robles, CA U.S.A. 93446 Ph. 855-663-9876, Fax 805-238-5766 In Canada | Zurn Industries Limited 3544 Nashua Drive, Mississauga, Ontario L4V 1L2 Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com Page 2 of 2 ⃟ Rated Flow (established by approval agencies)Flow Characteristics Typical Installation Local codes shall govern installation requirements. To be installed in accordance with the manufacturers’ instructions and the latest edition of the Uniform Plumbing Code. Unless otherwise specified, the assembly shall be mounted at a mini- mum of 12” (305mm) and a maximum of 30” (762mm) above adequate drains with sufficient side clearance for testing and maintenance. The installation shall be made so that no part of the unit can be submerged. OUTDOOR INSTALLATIONINDOOR INSTALLATION (Shown w/optional BMS) Specifications The Reduced Pressure Principle Backflow Preventer shall be certified to NSF/ANSI 61 shall be ASSE® Listed 1013, rated to 180°F, and supplied with full port ball valves. The main body and access covers shall be low lead bronze (ASTM B 584), the seat ring and all internal polymers shall be Noryl™ and the seat disc elastomers shall be silicone. The first and second checks shall be accessible for maintenance without removing the relief valve or the entire device from the line. If installed indoors, the instal- lation shall be supplied with an air gap adapter and integral monitor switch. The Reduced Pressure Principle Backflow Preventer shall be a ZURN WILKINS Model 975XL2. Capacity thru Schedule 40 Pipe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec 1/8"1 1 2 3 1/4"2 2 3 5 3/8"3 4 6 9 1/2"5 7 9 14 3/4"8 12 17 25 1"13 20 27 40 1 1/4"23 35 47 70 1 1/2"32 48 63 95 2"52 78 105 167 BATTERY MONITOR SWITCH* AIR GAP FITTING 12" MIN. 30" MAX. FLOOR DRAIN DIRECTION OF FLOW FLOOR CENTRAL STATION ALARM PA NEL 975XL2WILKINS ZURN12" MIN 30" MAX PROTECTIVE ENCLOSURE OPTIONAL WATER METER INLET SHUT-OFF AIR GAP DRAIN DIRECTION OF FLOW OPTIONAL LEAD-FREE STRAINER (MODEL SXL)975XL2WILKINS ZURN WILKINS XL0 20 40 60 805 10 15 20 0 50 100 150 200 2505 10 15 20 FLOW RATES (GPM)PRESSURE LOSS (PSIG) 69 PRESSURE LOSS (kpa) FLOW RATES (l/s) MODEL 975XL2 3/4", 1", 1 1/4", 1 1/2" & 2" (STANDARD & METRIC) 35 3/4" (20mm)1" (25mm)1 1/4" (32mm) 2" (50mm)103 15.812.69.56.33.25.03.82.521.26 1 1/2” (40mm) 137