Loading...
HomeMy WebLinkAbout19090162 State CDRELECTRONICALLY FILE YOUR PROJECT WITH STATE OF INDIANA at http://www.in.govidhs/2650.htm. This on-line filing is through a secure site, you can use it to submit your project information, pay the fees and upload your project plans. Use Internet Browser to View this report, other browsers are not compatible to view this report e" CONSTRUCTION DESIGN RELEASE yS State Form 41191 (R9/5-98) Report Printed on: June 25, 2019 �! Indiana Department of Homeland Security INDIANA 02 j DIVISION OF FIRE 8 BUILDING SAFETY `r(e 00(� PLAN REVIEW DIVISION IVI 0 it 402 W. Washington St, Room E245 --� Indianapolis, IN 46204 Available At Your Local Licence Branch To: Owner / Architect / Engineer SUPPORT HOOSIER SAFETY Schott Design Kevin Hugh Boyle AR10700017 450 East 96th St. Suite 175 Indianapolis IN 46240 Fax & e-mail: 3176609170, studiob@schottdesign.com 408753 construction type II -A, SPK B, REM Scope of release ARCH ELEC MECH PLUM Type of release --- - -------- Standard 06/24/19 i Project name Vacancy Conference & Fitness Center Renovatio Street address 10201 N Illinois St City --- County INniAmApnl m MAPInN The plans, specifications and application submitted for the above referenced project have been reviewed for compliance with the applicable rules of the Fire Prevention and Building Safety Commission. The project is released for construction subject to, but not necessarily limited to, the conditions listed below. THIS IS NOT A BUILDING PERMIT. All required local permits and licenses must be obtained prior to beginning construction work. All construction work must be in full compliance with all applicable State rules. Any changes in the released plans and/or specifications must be filed with and released by this Office before any work is altered. This release may be suspended or revoked if it is determined to be issued in error, in violation of any rules of the Commission or if it is based on incorrect or insufficient information. This release shall expire by limitation, and become null and void, if the work authorized is not commenced within one (1) year from the above date. CONDITIONS: Note :(Al A & Al B): In accordance with the affidavit sworn under penalties of perjury in the application for construction design release the plans and specifications filed in conjunction with this project shall comply with all of the applicable rules and laws of Fire Prevention and Building Safety Commission. Providing false information constitutes an act of perjury, which is a Class D felony punishable by a prison term and a fine up to $10,000. In accordance with Section 19 of the General Administrative Rules (675 IAC 12-6-19) a complete set of plans and specifications that conform exactly to the design that was released by the office of the state building commissioner shall be maintained on the construction jobsite as well as a copy of the design release. 14B This project has been reviewed under the 2014 Indiana Building Code. 4GO412AC No addition or alteration shall cause an existing building, structure, or any part of the permanent heating, ventilating, air conditioning, electrical, plumbing, sanitary, emergency detection, emergency communication, or fire or explosion suppression systems to become unsafe or overloaded under the provisions of the rules of the Commission for new construction in accordance with 675 IAC 12-4- 12(c). 4GO603AF Detailed plans and specifications for the revised fire suppression system shall be filed with the required application and appropriate fees in accordance with 675 IAC 12-6- 3(a), 675 IAC 12-6- 7(g)(17), and 675 IAC 13-1-8. (N.F.P.A. 13) 14W1104A Required means of egress shall be maintained during construction and demolition, remodeling or alterations and additions to any building, in accordance with Section 1104, IFC (675 IAC 22-2.5). 4GO412AF No addition, alteration, or repair shall reduce existing exit capacities to less than that required under the provisions of the rules of the Indiana Fire and Building Safety Commission for new construction in accordance with 675 IAC 12-4-12(d). 141306011IA The minimum construction type permitted for this building is Type II -A. Building elements shall be protected as specified in Chapters 5, 6, and Table 601, IBC (675 IAC 13-2.6). NOTE: This project release does not include the finish of one or more tenant spaces. Tenant space finishes shall be filed as a new project in accordance with 675 IAC 12-6-6 before commencing work. AREL Pursuant to 675 IAC 12-6-21, the issuance of a design release does not relieve the owner from required compliance with all applicable rules of the commission, even if noncompliant conditions appear in the plans and specifications that have been filed with the division. The owner is responsible for correcting any and all areas of noncompliance even if they are discovered subsequent to the issuing of this design release. Page 1/2