HomeMy WebLinkAboutMIDRWON FLATS POOL1.14' MAXIMUM
SWIMMING POOL REQUIREMENTS AND
SPECIFICATIONS:
E LATCH REQUIREMENTS
MINIMUM 54" ABOVE DECK FLOOR
SHALL BE SELF -CLOSING, SELF -LATCHING,
AND LOCKABLE.
RELEASE MECHANISM ON POOL SIDE OF LATCH.
GATES SHALL SWING OUT FROM POOL.
FENCE USED AS DESIGN GUIDE:
AMERISTAR MONTAGE II
WELDED STEEL ORNAMENTAL FENCE
INSTALL STRICTLY TO MANUFACTURER'S
WRITTEN SPECIFICATIONS.
FENCE ELEVATION
GATE
DETAILS
<LIGHTING RNG
IF N IMENTB:
KING LIGHTING F NGHT SWIMMING IS ALLOWED:
SCALE: 1/2" = 1'-0"
SCALE:
1/2" = 1'-0"
EA AND POOL LIGHTING COMBINED SHALL PROVIDE
T LESS THAN 10 FOOT CANDLES OF LIGHT TO ALL
RTS OF THE POOL AND DECK AREAS.
OT CANDLE MEASUREMENT SHALL BE FROM 6" ABOVE
CK SURFACE.
P L LIGHTING REQUIREMENTS:
E DETAIL 2, SHEET A3.1 FOR CONSTRUCTION DETAILS
IOV IDE A MINIMUM OF 8.35 LUMENS PER SQUARE FOOT
'WATER SURFACE.
SCOPE OF WORK:
A. Provide all labor, material, tools, and equipment necessary for
swimming pool, circulations pumps, pool filter systems, chemical
treatment, piping and finishes.
B. Include cost and securing of all permits required by all governmental
agencies and submittals to regulatory bodies, including state and local
agencies.
STEEL REINFORCING:
A. Pool steel reinforcement shall be the responsibility of the Pool
Contractor, following plans prepared by a registered engineer or
architect.
PIPE INSTALLATION:
A. Use fittings for all changes in direction, changes in size, an
connections.
B. When possible, locate groups of pipes parallel to each othc
permit servicing of valves.
C. Locate all recirculating pipes in the floor of the pool, teeing
up the walls of the pool at the closest location to that fil
D. Install flow meter in accordance with the latest guidelines F
the state or local health departments.
E. Pipes should be hung using pipe hangers when in proximit
pump room ceiling and under braced supports when in
pump room floor.
F. Hydrostatically test the pool under 30 psi of air at least 24 t
to covering any piping with a maximum drop of two (2)
Pressure shall remain on all lines while any covering of
place.
QUALITY ASSURANCE: POOL SURFACE FINISH:
A. Pool Contractor shall perform all work in compliance with the A. Apply swimming pool plaster finish to all vertical and horizc
requirements of the following agencies: surfaces except as designated to receive other finishes
Indiana Swimming Pool Code, current edition. not acceptable.
International Building Code (Indiana Building Code, current edition) B. Trowel apply finish from''/4" to 1/2" thickness, trowel to even.
Local Health and Building Regulations hard surfaces free of surface blemishes and depressio
OSHA
POOL CONSTRUCTION:
A. Construction shall be Gunite or Shotcrete as specified by the American
Concrete Institute.
B. Final curing crush -strength of not less than 4,500 psi.
C. The walls of the pool are to be vertical and slope no greater than
eleven (11) degrees from plumb.
D. Provide a cove, not to exceed a 6" radius, shot at the floor and wall
intersections.
E. During the Gunite/Shotcrete application, all piping shall remain under
30 psi of air pressure.
SEQUENCING AND SCHEDULING:
A. The General Contractor and the Pool Contractor shall coordinate any
required pipe sleeves, conduits and building wall penetrations.
PIPE AND FITTING MATERIALS:
A. The swimming pool filter system piping shall be design pressure
Schedule 40 PVC, Rigid, Type 1 Grade 1, ANSI/ASTM D1785. Joints
shall be solvent -weld socket types as recommended by the pipe
manufacturer, fittings shall be PVC, normal impact Type 1,
ANSI/ASTM D2466, With solvent -weld socket ends for Schedule 40
pipe.
POOL SYSTEM SPECIALTIES:
A. Main drain suction line shall be plumbed to two (2) separate main drain
grates.
B. Skimmers shall be of PVC construction with two (2) 2" port threaded
outlets.
C. Returns shall be evenly spaced or as shown on drawings and in
accordance with the latest guidelines put forth by the state or local
health departments.
n Cln.., ...n.n.e e"I kn „,rid In . ,rdance with the latest guidelines put
RELEASED FOR CONSTRUCTION th departments.
both the influent and effluent sides of
Subject to compliance with all regulations the latest guidelines put forth by the
of State and meal Codes nts_
City of Camel
DATE: 10/16/19
IIll branch
[paced to
angling
9
forth by
I the
oximity to the
ns prior
unds.
ping is taking
at pool
Tool paint is
nooth,
TILE:
A. Apply 6"4" swimming pool tile at water line, as selected by Owner.
Pool contractor shall submit sample boards or tiles for Owner's
selection.
B. Surface accepting tile shall be clean, dry, and free of oily or waxy build-
up.
C. Clean glaze of tile using water and detergent as work progresses.
D. "NO DIVING" and depth indicator tiles shall be in accordance with the
latest codes and guidelines put forth by the state and/or local health
departments.
COPING:
A Install precast or brick coping in accordance with ANSI A108-1976
standards, grout with a color compatible with color of coping.
B. Coping shall meet all codes and standards of state and/or local health
departments.
DECK APPLIANCES:
A Install stainless steel handrails at the pool step entry/exit as shown on
drawings.
B. One three (3) step stainless steel ladder shall be placed at the deep
end of the pool as shown on drawings.
C. All deck anchors shall be brass.
D. All escutcheon plates shall be stainless steel and free of marring and
defects.
MAINTENANCE ACCESSORIES:
A. One (1) 1 %" 35 foot long vacuum hose.
B. One (1) wall adapter.
C. One 18"vacuum cleaner head.
D. One (1) telescoping pole With locking nut.
E. One (1) 18" curved wall brush.
F. One (1) 12" algae brush.
G. One (1) dip net.
H. One (1) DPD test kit.
SAFETY EQUIPMENT:
A. One (1) 24" U.S. Coast Guard approved life buoy with a minimum 30
foot throw line.
B. One (1) solid non-adjustable pole With life hook.
C. One (1) spine board with straps.
D. One (1) 24-unit first aid kit with disposable gloves.
FILLING OF POOL:
A. Pool Contractor shall coordinate timing of fill with the General
Contractor and/or Owner to assure construction is complete.
B. Do not fill the pool until the filter system is ready to be placed in
operation.
INSTRUCTIONS AND TRAINING:
A. Pool Contractor shall coordinate the instruction of the operation of the
pool and its appliances to all interested parties on a selected normal
workday.
B. Provide to the Owner all manuals and written instructions on the pool
appliances.
16' 11"
0
0
e /
50'-0"
LAIJOSCAPE BED
BY OTHERS
OVERALL DECK PLAN
SCALE: 1/4" = 1'-0"
i97
Y
Q
J
U
Z
Q
m
O
0
0
^/
�OL
ETAIL
V
C 0
O J W
MMNI 7 Z
Z OQ
O in 0
tL Z Z
O pw
a �g
7�zLo0
H
O DRAWING COMPLETION DNI
JULY 12, 2019
`aouummDie"y',
A o � eHs..C7Y
• AR00032537
STATE OF
�'1'D I ASP •`