HomeMy WebLinkAboutA111 Floor PlanDECONSTRUCTION LEGEND RECYCLING INSTRUCTIONS DECON. GENERAL NOTES
EXISTING TO BE REMOVED EXISTING TO REMAIN CO -MINGLE RECYCLING CONTAINER: I. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS
WALL
WALL
mmmmmm PARTIAL HEIGHT WALL I � PARTIAL HEIGHT WALL
DOOR AND FRAME 7 DOOR AND FRAME
WINDOW / SIDELIGHT
4_____I_
CEILING GRID AND
y_____r TILES, 2'A
--4--D I I CEILING GRID AND
i--?--r TILES, 2'x2'
F'T
I i'I SUPPLY AIR DIFFUSERS
cammili
k �y
1r= —l1
LIGHT FIXTURE,
FLUORESCENT, 2k4'
r=a
LIGHT FIXTURE,
L11
_A
FLUORESCENT, 2'x2'
)CC
LIGHT FIXTURE, CAN
FYI•4
LIGHT FIXTURE, TRACK
TP LIGHT FIXTURE, SCONCE
LIGHT FIXTURE,
PENDANT
LIGHTSWITCH
EXIT LIGHT
qiy^
C—]
EMERGENCY LIGHT
ELECTRIC OUTLETS)
1BiIDi1 �:
DATA OR
la COMMUNICATION
OUTLET
x WINDOW/SIDELIGHT
NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN
GOOD CONDITION.
n
u
"""
II II II Iej�'1
II 11 II IL_Y
II 11 II
II
Fr =— l� ii
r1�
rr17
L4__ �i a
,I II
II II
TI•ev_ �� II
I. CONTACT WASTE HAULER r0 ORDER TRASH DUMPSTER(S) AS
REQUIRED AND III CO -MINGLE RECYCLING BIN FOR DEMOLTION
PORTION OF PROJECT ONLY. SIZE CO -MINGLE CONTAINER
ACCORDING TO AMOUNT OF DEMOLITION (10-40 YARD
CONTAINERS AVAILABLE).
2. WASTE HAULER WILL APPLY CREDIT FOR METALS OBTAINED IN
CO -MINGLE CONTAINER TOWARDS CONTRACTORS OVERALL
INVOICE. PROVIDE COPY OF INVOICE r0 LANDLORD AS PROOF
OF RECYCLING.
3. TYPICAL ITEMS FOR CO -MINGLE CONTAINER:
3.1. ALL METALS INCLUDING: METAL STUDS, DOOR FRAMES,
CEILING GRID, LIGHT BOX FIXTURES, ELECTRICAL AND DATA
WIRING/ CONDUIT, HVAC COMPONENTS, AND
ELECTRICAL/DATA/SWITCH BOXES.
3.2. SHIPPING/PACKAGING CARDBOARD/PLASTICS, WOOD
STUDS, WOOD TRIM
4. DRYWALL MUST BE REMOVED FROM ALL METAL STUDS PRIOR TO
PLACING IN CO -MINGLE CONTAINER.
CARPET RECYCLING:
5. CONTACT KRUSE CARPET RECYCLING TO SCHEDULE PICK UP OF
ALL CARPET BEING REMOVED )BROADLOOM AND CARPET TILE).
COORDINATE REQUIREMENTS AND PICK UP WITH SUSAN SHAFER
(31 7) 337-1950.
6. KRUSE WILL PROVIDE A DUMPSTER ON STE ON DAYS REQUIRED,
OR PICK UP IN A BOX TRUCK. DEMOLITION CREW IS TO PLACE
CARPET DIRECTLY INTO TRUCK OR DUMPSTER; DOES NOT NEED TO
BE PALLETIZE.
7. KRUSE PICKUP AND RECYCLING FEES ARE r0 BE PAID THROUGH
SCHOTT DESIGN'S NO COST ADD PROGRAM. CARPET
MANUFACTURER IS TO PAY THE $1.00 PER SQUARE YARD FOR
CARPET RECYCLING BY REDUCING PRICE OF CARPET MATERIAL BY
$1.00. FLOORING CONTRACTOR IS BE RESPONSIBLE FOR
DEDUCTING MATERIAL PRICE AND PAYING THE AMOUNT TO
KRUSE. CONTACT SDI FOR ANY QUESTIONS.
+36"
I �`I ly�Jll C
DECONSTRUCTION PLAN
0 2' 4' 8' 16'
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VTI�tDwN'1BD�
DATE: \ 10/16/19
SHOWN ON PLAN PER LEGEND. PATCH WALL AND
PREPARE FOR NEW FINISHES AS REQUIRED.REFER TO ALL
DECONSTRUCTION NOTES ON TITLE SHEET TI 11.
2. ALL ITEMS BEING REMOVED FROM PROJECTAREA ARE TO
BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT
OR BUILDING IF POSSIBLE. FOR ALL ITEMS DETERMINED
FOR REMOVAL, REFER r0 THE RECYCLING INSTRUCTIONS.
3. REMOVE ALL EXISTING WOOD CROWN MOLDING AND
BASE THROUGHOUT.
DECON. PLAN NOTES
O01 REMOVE EXISTING CABINETRY AND COUNTERTOP,
CONFIRM WITH LANDLORD FOR STORAGE
LOCATION.
D02 REMOVE EXISTING SINK, SALVAGE FOR RELOCATION.
NO SERVICE SINKS ARE BEING REMOVED.
D03 REMOVE EXISTING PHONE BOARD AT THIS
LOCATION. PATCH AND REPAIR WALLAS REQUIRED
FOR NEW FINISHES.
OSALVAGE EXISTING CASEWORK FOR RELOCATION.
D04 SEE ARCHITECTURAL PLAN FOR LOCATION.
WALL TYPES
NOTE:
• ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL
ALL WALLS ARE TO BE H UNLESS OTHERWISE NOTED.
• EXISTING WALLS AREA CONSTRUCTED WITH 2 I'METAL STUDS.
CONTRACTOR TO PLAN ACCORDINGLY. NOT ALL WALL TYPES LISTED
BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO TYPICAL WAL
REFLECTED CEILING PLAN FOR CEILING HEIGHTS.
METAL STUD
STANDARD WALL -
3S/e" METAL STUDS AT 16" O.C.;
ONE LAYER OF% TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALLTO UNDERSIDE OF CEILING
WALL WTH INSULATION
3% METAL STUDS AT 16 O.C.; ,i'��`,/�i EXISTING WIN
ONE LAYER OF S/e" TYPE "X" GYPSUM BOARD MULLION
EACH SIDE;
EXTEND WALL TO UNDERSIDE OF CEILING;
FIBERGLASS SOUND BATT INSULATION INSIDE
WALL AND 2'-0" EACH SIDE OF WALL ABOVE
CEILING
PARTIAL HEIGHT WALL
3S%" METAL STUDS AT 16" O.C.;
ONE LAYER OF% TYPE "X" GYPSUM BOARD --
EACH SIDE;
EXTEND WALLTO 2-101
PROVIDE 1" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED
PARTIAL HEIGHT WALL
3% METAL STUDS AT 16" O.C.;
ONE LAYER OF %' TYPE "X" GYPSUM BOARD
EACH SIDE;
EXTEND WALLTO 3'-4}";
PROVIDE I" STEEL PIPE ANCHORS INTO
CONCRETE FLOOR FOR SUPPORT AS
REQUIRED
PLAN NOTES
A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS
STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS
ARE IN LINE WITH EXISTING WALLS.
OA02 PROVIDE PLYWOOD PHONE BOARD, 4'x8'xi, PAINTED WITH FIRE
RETARDANT PAINTTO MATCH ADJACENT WALL FINISH. VERIFY
LOCATION WITH TENANT PRIOR TO INSTALLATION.
NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY
A03
CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED
ACCORDING TO NFPA 10.
A04 PROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR
TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT
LOCATION WITH TENANT.
OCONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W2". IF NOT,
A05 ALTER EXISTING WALL AS REQUIRED TO MATCH"W2"
OPROVIDE PLASTIC LAMINATE (PL2) COUNTER ON TOP OF PARTIAL
A08 HEIGHT WALL. COUNTER TO BE 48"W AND HAVE I"OVERHANG
ON WEST END OF PARTIAL HEIGHT WALL. SEAL EAST END OF
COUNTER TO WALL WITH CLEAR SILICONE.
PROVIDE 24" DEEP PLASTIC LAMINATE WORK SURFACE AT 30"
A07 A.F.F. WITH (2) GROMMETS AND 12" DEEP PLASTIC LAMINATE
TRANSACTION TOP ON TOP OF PARTIAL HEIGHT WALL AT 42" A.F.F.
SUPPORT COUNTER AS REQUIRED W TH CENTERLINE BRACKET'S
FRONT MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS
WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER
VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL
BRACKETS AS NEEDED PRIOR r0 INSTALLATION OF DRYWALL.
COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL
INSTALLATION AS NEEDED.
OPROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR
TENANT'S SIGNAGE; COORDINATE EXACT LOCATION WITH
TENANT.
(AD9 PROVIDE ALTERNATE PRICE FOR 30'-0"W X2'-O'H'q'BUTr-GLAZED
GLASS CLERESTORY WINDOWS WITH FRAME r0 MATCH DOOR
FRAME TYPE AND FINISH AT THIS LOCATION. TOP OF FRAME TO
MATCH TOP OF DOOR FRAME.
A10 RELOCATE EXISTING CASEWORK SALVAGED FROM
DECONSTRUCTION TO LOCATION SHOWN ON PLAN. EXISTING
FINISHES TO REMAIN, CLEAN AND REPAIR AS REQUIRED.
PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE
P01 AND VENT PIPING FOR SINKS,
REFER TO LANDLORD FOR SOURCE OF HOT WATER AND
LOCATION ALLOWED IN THIS BUILDING.
Pot PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM
LOCATION WITH TENANT.
WALL
THFICC KKN'Ej�SS
z
PRE -FINISHED ALUMINUM
RECEIVER TRIM - FASTEN AT
WINDOW SILL AND SET IN A
CONTINUOUS BEAD OF
CAULK AT WINDOW MULLION
WHERE NEW WALLS MEET.
TRIM COLOR TO MATCH
BUILDING WINDOW
MULLIONS.
LINE OF EXISTING WINDOW
SILL COVER BELOW
CONTINUOUS BEAD OF
ACOUSTICAL SEALANT
WALL AT MULLION DETAIL
AI1T NOT TO SCALE
ARCHITECTURAL LEGEND
NEW CONSTRUCTION
WALL
W7
® PARTIAL HEIGHT WALL
io� WINDOW/SIDELIGHT
EXISTING TO REMAIN
WALL
[» PARTIAL HEIGHT WALL
Ei WINDOW/SIDELIGHT
�l�/ DOOR AND FRAME DOOR AND FRAME
(SEE DOOR SCHEDULE)
NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM
DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS.
GENERAL NOTES
I. SEE ELECTRICAL PLAN FOR INTENDED FURNTURE LAYOUT.
2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR
WALLCOVERING THAT REQUIRES LEVEL 4OR LEVEL 5 DRYWALL
FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. r
ARCHITECTURAL
0 2' 4' 8' 16'
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN, ARETHE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC., AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WTHOLF THE WRITTEN
CONSENT OF SCH07 DESIGN.
M O0
Eu N
O"iN�
/U W C/j
LU
I
O
in
V Q
mommommi O ~ Z
m=a<
W n
N
ISSUE
DATE
DESCRIPTION
08.07.19
REVIEWSET
08.12.19
PERMITSET
08.29.19
CONSTRUCTION SET
REVISIONS
MAR DAIS DB DESCRIPTIONiiiiiiiw
PROJECT NUMBER
2019.127
DRAWN BY
MS/AMM
3RD FLOOR
DECONSTRUCTION PLAN/
ARCHITECTURAL
FLOOR PLAN
AIII