Loading...
HomeMy WebLinkAboutA111 Floor PlanDECONSTRUCTION LEGEND RECYCLING INSTRUCTIONS DECON. GENERAL NOTES EXISTING TO BE REMOVED EXISTING TO REMAIN CO -MINGLE RECYCLING CONTAINER: I. REMOVE EXISTING RECEPTACLES AND/OR SWITCHES AS WALL WALL mmmmmm PARTIAL HEIGHT WALL I � PARTIAL HEIGHT WALL DOOR AND FRAME 7 DOOR AND FRAME WINDOW / SIDELIGHT 4_____I_ CEILING GRID AND y_____r TILES, 2'A --4--D I I CEILING GRID AND i--?--r TILES, 2'x2' F'T I i'I SUPPLY AIR DIFFUSERS cammili k �y 1r= —l1 LIGHT FIXTURE, FLUORESCENT, 2k4' r=a LIGHT FIXTURE, L11 _A FLUORESCENT, 2'x2' )CC LIGHT FIXTURE, CAN FYI•4 LIGHT FIXTURE, TRACK TP LIGHT FIXTURE, SCONCE LIGHT FIXTURE, PENDANT LIGHTSWITCH EXIT LIGHT qiy^ C—] EMERGENCY LIGHT ELECTRIC OUTLETS) 1BiIDi1 �: DATA OR la COMMUNICATION OUTLET x WINDOW/SIDELIGHT NOTE: EXISTING FIXTURES THAT ARE REMOVED CAN BE REUSED IF IN GOOD CONDITION. n u """ II II II Iej�'1 II 11 II IL_Y II 11 II II Fr =— l� ii r1� rr17 L4__ �i a ,I II II II TI•ev_ �� II I. CONTACT WASTE HAULER r0 ORDER TRASH DUMPSTER(S) AS REQUIRED AND III CO -MINGLE RECYCLING BIN FOR DEMOLTION PORTION OF PROJECT ONLY. SIZE CO -MINGLE CONTAINER ACCORDING TO AMOUNT OF DEMOLITION (10-40 YARD CONTAINERS AVAILABLE). 2. WASTE HAULER WILL APPLY CREDIT FOR METALS OBTAINED IN CO -MINGLE CONTAINER TOWARDS CONTRACTORS OVERALL INVOICE. PROVIDE COPY OF INVOICE r0 LANDLORD AS PROOF OF RECYCLING. 3. TYPICAL ITEMS FOR CO -MINGLE CONTAINER: 3.1. ALL METALS INCLUDING: METAL STUDS, DOOR FRAMES, CEILING GRID, LIGHT BOX FIXTURES, ELECTRICAL AND DATA WIRING/ CONDUIT, HVAC COMPONENTS, AND ELECTRICAL/DATA/SWITCH BOXES. 3.2. SHIPPING/PACKAGING CARDBOARD/PLASTICS, WOOD STUDS, WOOD TRIM 4. DRYWALL MUST BE REMOVED FROM ALL METAL STUDS PRIOR TO PLACING IN CO -MINGLE CONTAINER. CARPET RECYCLING: 5. CONTACT KRUSE CARPET RECYCLING TO SCHEDULE PICK UP OF ALL CARPET BEING REMOVED )BROADLOOM AND CARPET TILE). COORDINATE REQUIREMENTS AND PICK UP WITH SUSAN SHAFER (31 7) 337-1950. 6. KRUSE WILL PROVIDE A DUMPSTER ON STE ON DAYS REQUIRED, OR PICK UP IN A BOX TRUCK. DEMOLITION CREW IS TO PLACE CARPET DIRECTLY INTO TRUCK OR DUMPSTER; DOES NOT NEED TO BE PALLETIZE. 7. KRUSE PICKUP AND RECYCLING FEES ARE r0 BE PAID THROUGH SCHOTT DESIGN'S NO COST ADD PROGRAM. CARPET MANUFACTURER IS TO PAY THE $1.00 PER SQUARE YARD FOR CARPET RECYCLING BY REDUCING PRICE OF CARPET MATERIAL BY $1.00. FLOORING CONTRACTOR IS BE RESPONSIBLE FOR DEDUCTING MATERIAL PRICE AND PAYING THE AMOUNT TO KRUSE. CONTACT SDI FOR ANY QUESTIONS. +36" I �`I ly�Jll C DECONSTRUCTION PLAN 0 2' 4' 8' 16' RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �VTI�tDwN'1BD� DATE: \ 10/16/19 SHOWN ON PLAN PER LEGEND. PATCH WALL AND PREPARE FOR NEW FINISHES AS REQUIRED.REFER TO ALL DECONSTRUCTION NOTES ON TITLE SHEET TI 11. 2. ALL ITEMS BEING REMOVED FROM PROJECTAREA ARE TO BE CAREFULLY CONSIDERED FOR REUSE IN THE PROJECT OR BUILDING IF POSSIBLE. FOR ALL ITEMS DETERMINED FOR REMOVAL, REFER r0 THE RECYCLING INSTRUCTIONS. 3. REMOVE ALL EXISTING WOOD CROWN MOLDING AND BASE THROUGHOUT. DECON. PLAN NOTES O01 REMOVE EXISTING CABINETRY AND COUNTERTOP, CONFIRM WITH LANDLORD FOR STORAGE LOCATION. D02 REMOVE EXISTING SINK, SALVAGE FOR RELOCATION. NO SERVICE SINKS ARE BEING REMOVED. D03 REMOVE EXISTING PHONE BOARD AT THIS LOCATION. PATCH AND REPAIR WALLAS REQUIRED FOR NEW FINISHES. OSALVAGE EXISTING CASEWORK FOR RELOCATION. D04 SEE ARCHITECTURAL PLAN FOR LOCATION. WALL TYPES NOTE: • ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL ALL WALLS ARE TO BE H UNLESS OTHERWISE NOTED. • EXISTING WALLS AREA CONSTRUCTED WITH 2 I'METAL STUDS. CONTRACTOR TO PLAN ACCORDINGLY. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO TYPICAL WAL REFLECTED CEILING PLAN FOR CEILING HEIGHTS. METAL STUD STANDARD WALL - 3S/e" METAL STUDS AT 16" O.C.; ONE LAYER OF% TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALLTO UNDERSIDE OF CEILING WALL WTH INSULATION 3% METAL STUDS AT 16 O.C.; ,i'��`,/�i EXISTING WIN ONE LAYER OF S/e" TYPE "X" GYPSUM BOARD MULLION EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING; FIBERGLASS SOUND BATT INSULATION INSIDE WALL AND 2'-0" EACH SIDE OF WALL ABOVE CEILING PARTIAL HEIGHT WALL 3S%" METAL STUDS AT 16" O.C.; ONE LAYER OF% TYPE "X" GYPSUM BOARD -- EACH SIDE; EXTEND WALLTO 2-101 PROVIDE 1" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED PARTIAL HEIGHT WALL 3% METAL STUDS AT 16" O.C.; ONE LAYER OF %' TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALLTO 3'-4}"; PROVIDE I" STEEL PIPE ANCHORS INTO CONCRETE FLOOR FOR SUPPORT AS REQUIRED PLAN NOTES A01 ALIGN FINISHED WALL SURFACES. PROVIDE SAME THICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLS ARE IN LINE WITH EXISTING WALLS. OA02 PROVIDE PLYWOOD PHONE BOARD, 4'x8'xi, PAINTED WITH FIRE RETARDANT PAINTTO MATCH ADJACENT WALL FINISH. VERIFY LOCATION WITH TENANT PRIOR TO INSTALLATION. NEW FIRE EXTINGUISHER TO BE PROVIDED AND INSTALLED BY A03 CONTRACTOR. ALL FIRE EXTINGUISHERS ARE TO BE INSTALLED ACCORDING TO NFPA 10. A04 PROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR TENANT'S WALL MOUNTED TELEVISION; COORDINATE EXACT LOCATION WITH TENANT. OCONFIRM THAT EXISTING WALL MATCHES WALL TYPE "W2". IF NOT, A05 ALTER EXISTING WALL AS REQUIRED TO MATCH"W2" OPROVIDE PLASTIC LAMINATE (PL2) COUNTER ON TOP OF PARTIAL A08 HEIGHT WALL. COUNTER TO BE 48"W AND HAVE I"OVERHANG ON WEST END OF PARTIAL HEIGHT WALL. SEAL EAST END OF COUNTER TO WALL WITH CLEAR SILICONE. PROVIDE 24" DEEP PLASTIC LAMINATE WORK SURFACE AT 30" A07 A.F.F. WITH (2) GROMMETS AND 12" DEEP PLASTIC LAMINATE TRANSACTION TOP ON TOP OF PARTIAL HEIGHT WALL AT 42" A.F.F. SUPPORT COUNTER AS REQUIRED W TH CENTERLINE BRACKET'S FRONT MOUNTING PLUS BRACKET ATTACHED TO METAL STUDS WITH WOOD BLOCKING AND DRYWALL INSTALLED OVER VERTICAL SUPPORT. CASEWORK CONTRACTOR TO INSTALL BRACKETS AS NEEDED PRIOR r0 INSTALLATION OF DRYWALL. COORDINATE APPROVAL OF SHOP DRAWINGS WITH DRYWALL INSTALLATION AS NEEDED. OPROVIDE ADDITIONAL BLOCKING IN WALLAS REQUIRED FOR TENANT'S SIGNAGE; COORDINATE EXACT LOCATION WITH TENANT. (AD9 PROVIDE ALTERNATE PRICE FOR 30'-0"W X2'-O'H'q'BUTr-GLAZED GLASS CLERESTORY WINDOWS WITH FRAME r0 MATCH DOOR FRAME TYPE AND FINISH AT THIS LOCATION. TOP OF FRAME TO MATCH TOP OF DOOR FRAME. A10 RELOCATE EXISTING CASEWORK SALVAGED FROM DECONSTRUCTION TO LOCATION SHOWN ON PLAN. EXISTING FINISHES TO REMAIN, CLEAN AND REPAIR AS REQUIRED. PROVIDE POTABLE HOT AND COLD WATER AND SANITARY WASTE P01 AND VENT PIPING FOR SINKS, REFER TO LANDLORD FOR SOURCE OF HOT WATER AND LOCATION ALLOWED IN THIS BUILDING. Pot PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. WALL THFICC KKN'Ej�SS z PRE -FINISHED ALUMINUM RECEIVER TRIM - FASTEN AT WINDOW SILL AND SET IN A CONTINUOUS BEAD OF CAULK AT WINDOW MULLION WHERE NEW WALLS MEET. TRIM COLOR TO MATCH BUILDING WINDOW MULLIONS. LINE OF EXISTING WINDOW SILL COVER BELOW CONTINUOUS BEAD OF ACOUSTICAL SEALANT WALL AT MULLION DETAIL AI1T NOT TO SCALE ARCHITECTURAL LEGEND NEW CONSTRUCTION WALL W7 ® PARTIAL HEIGHT WALL io� WINDOW/SIDELIGHT EXISTING TO REMAIN WALL [» PARTIAL HEIGHT WALL Ei WINDOW/SIDELIGHT �l�/ DOOR AND FRAME DOOR AND FRAME (SEE DOOR SCHEDULE) NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. GENERAL NOTES I. SEE ELECTRICAL PLAN FOR INTENDED FURNTURE LAYOUT. 2. REFER TO FINISH PLAN FOR ALL ACCENT/SPECIALTY PAINT OR WALLCOVERING THAT REQUIRES LEVEL 4OR LEVEL 5 DRYWALL FINISH. REFER TO MANUFACTURER RECOMMENDATIONS. r ARCHITECTURAL 0 2' 4' 8' 16' THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARETHE EXCLUSIVE INTELLECTUAL PROPERTY OF SCH07 DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WTHOLF THE WRITTEN CONSENT OF SCH07 DESIGN. M O0 Eu N O"iN� /U W C/j LU I O in V Q mommommi O ~ Z m=a< W n N ISSUE DATE DESCRIPTION 08.07.19 REVIEWSET 08.12.19 PERMITSET 08.29.19 CONSTRUCTION SET REVISIONS MAR DAIS DB DESCRIPTIONiiiiiiiw PROJECT NUMBER 2019.127 DRAWN BY MS/AMM 3RD FLOOR DECONSTRUCTION PLAN/ ARCHITECTURAL FLOOR PLAN AIII