HomeMy WebLinkAboutA121 Electrical and Reflected CeilingELECTRICAL LEGEND NEW CONSTRUCTION EXISTING TO REMAIN POWER OUTLET, DUPLEX POWER OUTLET, DUPLEX .N, ^N' POWER OUTLET POWER OUTLET, QUADRUPLEX QUADRUPLEX Q JUNCTION BOX J JUNCTION BOX CEILING MOUNTED CEILING MOUNTED JUNCTION BOX JUNCTION BOX ® BOX, BLANK COVER PLATE ® BOX, BLANK COVER PLATE BOX, OPEN QO BOX, OPEN P PROVIDE JUNCTION BOX P POWER AND DATA POLE D ABOVE CEILING FOR O POWER POLE CONNECTION. POWER POLE BY OTHERS. FLOOR BOX WITH POWER FLOOR BOX WITH POWER 5I41 AND DATA, FLUSH AND DATA, FLUSH MOUNTED MOUNTED FLOOR BOX WITH FLOOR BOX WITH FQ K JUNCTION BOX AND J b JUNCTION BOX AND DATA, FLUSH MOUNTED DATA, FLUSH MOUNTED DATA/COMMUNICATION DATA/COMMUNICATION 10 OUTLET (PROVIDE BOX 4 OUTLET AND PULL STRING ONLY) DIED DEDICATED CIRCUIT GFCI GROUND FAULT CIRCUIT INTERRUPT OUTLET +42' HEIGHT OF ELECTRICAL OR DATA DEVICE ELECTRICAL PLAN NOTES E01 PROVIDE FLUSH MOUNT FLOOR CORE WITH POKE THIRD DEVICE FOR ELECTRICAL AND DATA. COORDINATE WITH TENANTS FURNITURE VENDOR ON EXACT LOCATION. PROVIDE POKE THIRD DEVICE SUBMITTAL TO TENANT FOR APPROVAL PRIOR TO ORDERING. E02 COORDINATE COPIER RECEPTACLE WITH TENANT. PROVIDE DEDICATED RECEPTACLE AS REQUIRED. E03 CONFIRM POWER REQUIREMENTS FOR SERVER I I I WITH TENANT. E04 PROVIDE DEDICATED POWER OUTLET IN RECESSED BOX INSET INTO B CABINET/ WALL FOR TENANT'S MICROWAVE, CENTERED AT 24' A.F.F. E05 PROVIDE POWER AND DATA FOR TENANT'S WALL MOUNTED TELEVISION AT HEIGHT NOTED ON PLAN, COORDINATE EXACT LOCATION WITH TENANT, E08 PROVIDE POWER AT THIS LOCATION FOR TENANT'S GARBAGE DISPOSAL. E07 PROVIDE POWER AT THIS LOCATION FOR TENANT PROVIDED SIGNAGE.IF ALTERNATE FOR CLERESTORY WINDOW IS ACCEPTED, CONFIRM HEIGHT OF POWER WITH TENANT, B a ORAGE EXEC. El OFFICE Y� o r— OFFICE los I " b OFFICE .. E01 CD 1 U6 s�J}'�T� Lou OFFICE EXEC. V _ OFFICE OFFICE 17711 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �VM1��VtIa�DAAK DATE: 10/16/19 GENERAL ELEC. NOTES I. TENANTS FURNITUREVENDOR IS RESPONSIBLE FOR INSTALLATION OF FURNITURE AND FIELD VERIFICATION OF ALL CRITICAL DIMENSIONS. 2. ALL OUTLETS ARE TO BE INSTALLED 18' MIN. A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. ALL NEW DEVICES AND FACE PLATES TO MATCH EXISTING. 3. REFER TO DOORSCHEDULEAND COORDINATE WITH TENANT/OWNER REGARDING POWER LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES, CARD READERS AND/OR MAG-LOCKS. CARD READERS ARE TYPICALLY INSTALLED BY THE TENANT'S SECURITY CONTRACTOR AND NOT SPECIFIED BY SDI. 4. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PUNS CAN BE FILED AN D MUST COMPLY WITH ALL APPLICABLE CODES, ENTRY 1771 OPEN OFFICE n 777 ELECTRICAL PLAN 0 2' 4' 8' 16' RCP LEGEND NEW OR RELOCATED EXISTING TO REMAIN r--� LIGHT FIXTURE,2'x4 PARABOLIC LIGHT FIXTURE, Tx2' III PARABOLIC 0 PARABOLIC LIGHT FIXTURE, I'x4', o FLUORESCENT, INDIRECT LIGHT FIXTURE, T TRACK RECESSED UGHT FIXTURE, FROM DECONSTRUCTION �..,..,., LIGHT FIXTURE WALL SCONCE UGHT FIXTURE ® UGHT FIXTURE, PENDANT, TENANT PROVIDED NL NIGHT LIGHT LIGHT FIXTURE, 2'x4', PARABOLIC LIGHT FIXTURE, Tx2' PARABOLIC 0 LIGHT FIXTURE, 1'X4', PARABOLIC LIGHT FIXTURE, 1'x4', o FLUORESCENT, INDIRECT LIGHT FIXTURE, TRACK X( RECESSED UGHT FIXTURE 0A WALL SCONCE UGHT FIXTURE ® UGHT FIXTURE, PENDANT ® EXIT LIGHT FIXTURE ® EXIT LIGHT FIXTURE EMERGENCY LIGHT FIXTURE &1� EMERGENCY UGHT RXTURE $N LIGHT SWITCH $ UGHTSWITCH $N3 LIGHT SWITCH, SWAY $3 LIGHT SWITCH, SWAY $ND LIGHT SWITCH, DIMMER $D ITCH, (DIMMER LIGHTS $NP SWITCH, PROJECTOR $P SWITCH, PROJECTOR SCREEN SCREEN $NG SWITCH, GARBAGE $G SWITCH, GARBAGE DISPOSAL (ABOVE DISPOSAL COUNTERTOP) $NE SWITCH, EXHAUST FAN $E SWITCH, EXHAUST FAN LIGHTCIRCUF UGHTCIRCUIT CEILING GRID, Ji i� CEILING GRID, SUSPENDED, 2'X4' -�_____��- SUSPENDED, 2'X4' CEILING GRI CEILING 2 SUSPENDED, 'x2' -r--r--r- 2 SUSPENDED, 'x2' CEILING GRID, SUSPENDED,4k4' TEES TO CEILING GRID, COMPLETE GRID SUSPENDED, 4'X4' GYPSUM BOARD CEILING ❑ GYPSUM BOARD CEIUNC ❑ EXPOSED TO DECK RELOCATED DIFFUSER, DIFFUSER, LAY -IN, 2'x2 ® DAY IN, 2'x2' RELOCATED DIFFUSER, DIFFUSER, C..:.:.:- LAY -IN, 1'X4' ® LAY -IN, 1'x4' RELOCATED DIFFUSER, DIFFUSER, ® LAY IN, 4"x4' m DAY -IN, 4'54' EXHAUST FAN, 2'X2' � EXHAUST FAN, 2'x2' NOTE: IF IN GOOD CONDITION, EXISTING H.V.A.C. DEVICES AND CEILINGTILES SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW. NO NEW HVAC DUCTWORK IS TO BE INSTALLED PER THIS SHEET, GENERAL NOTES I. REUSE EXISTING CEILING GRID AND TILE UNLESS OTHERWISE NOTED. EXISTING GRID IS 2x2 AT 9'-0" A.F.F. TILES ARE 2x2 ACOUSTICAL LAY IN TILES. REPAIR ANY DAMAGED GRID AND REPLACE ANY DAMAGED TILES WITH NEW TO MATCH EXISTING. 2. PROVIDE LIKE CEILING TILES IN INDIVIDUAL ROOMS WHERE POSSIBLE TO CREATE UNIFORM LOOK. 3. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY, IN RECEPTION AREAS, CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE, ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE. 4. UNLESS NOTED OTHERWISE. THE LIGHTS SHOWN AS 'NEW OR RELOCATED" ARE TO BE RELOCATED FROM A PREVIOUS LOCATION AS SHOWN ON THE DEMOLITION PLAN. THE DESIGN INTENi1S LESS THAN 50%OF THE LIGHTS ARE ACTUALLY BEING REPLACED WITH NEW AND OVERALL WATTAGE IS STAYING THE SAME OR DECREASING. LAYOUT SHOWN IS INTENDED TO MEET ASHRAE 90.1 STANDARDS. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR COMPLIANT NSTALLATION. IF ADJUSTMENT IS REQUIRED TO MEET ASHRAE 90.1, CONTRACTOR MUST NOTIFY SDI. 5. NEW DEVICES AND FACE PLATES TO MATCH EXISTING. WHERE POSSIBLE, GANG MULTIPLE SWITCHES TO ACCOMMODATE MULTISWITCHPLATE WHEN SWITCHES ARE SHOWN ADJACENT ON PLAN, 6. ELECTRICAL WORK IS LIMITED TO A DESIGN -BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS. ALL ELECTRICAL WORK IS LIMITED TO ADDITIONS OR RELOCATIONS OF ELECTRICAL OUTLET DEVICES AND LIGHTING THAT DO NOT EXCEED THE CAPACITY OF THE EXISTING ELECTRICAL SERVICE IN THE BUILDING. ELECTRICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH ALL APPLICABLE CODES. 7. PROVIDE AND INSTALL 2X4 LITERONICS VOLUMETRIC LED RETROFIT KITS IN ALL LIGHT FIXTURES THROUGHOUT. MECHANICAL NOTES I. MECHANICAL WORK IS LIMITED TO A DESIGN- BUILD SCOPE AND IS OUTLINED IN THESE DRAWINGS, NO NEW MAIN MECHANICAL APPLIANCES OR MAIN EQUIPMENT ARE BEING PROVIDED. ALL MECHANICAL WORK IS LIMITED TO RELOCATION OF DIFFUSERS AND FLEX DUCT PER NEW WALL LAYOUT. IF IN GOOD CONDITION, EXISTING H,V,A,C, DIFFUSERS SALVAGED FROM DECONSTRUCTION MAY BE SUBSTITUTED FOR NEW. NO NEW HARD DUCTWORK OR EQUIPMENT IS BEING ADDED; MECHANICAL CONTRACTOR IS TO NOTIFY APPLICABLE PARTIES IF ADDITIONAL WORK IS REQUIRED SO THAT ADDITIONAL PLANS CAN BE FILED AND MUST COMPLY WITH THE RICPA P1 € AlIq $40TEISTHER APPLICABLE CODES. R01 CONTROL CORRIDOR, BREAK, COPY, AND OPEN OFFICE AREA LIGHTING WITH SWITCH AT THIS LOCATION. RELOCATE DIFFUSERS & FLEXDUCT IF REQUIRED VAV/ EXISTING VAV BOXES OR HEAT PUMP AND MAIN SUPPLY DUCTS TO REMAIN MECHANICAL DIFFUSER RELOCATION "REFER TO MECHANICAL NOTES FOR FURTHER INFORMATION REFLECTED CEILING PLAN 0 2' 4' 8' 16' AA W' THIS DRAWING, AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN, ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF SCHOTT DESIGN, INC., AND ARE NOT TO BE USED OR REPRODUCED IN WHOLE, OR IN PART, WITHOLR THE WRITTEN CONSENT OF SCH07 DESIGN. SSUE DATE I DESCRIPTION 08.07.19 REVIEW SET 08.12.1E PERMIT SET 08.29.19 CONSTRUCTION SET REVISIONS MARK DATE I DB IDESCRIPTION PROJECT NUMBER 2019.127 PROJ.MGR DRAWN BY I MS/SDH MS/AMM 3RD FLOOR ELECTRICAL PLAN/ REFLECTED CEILING PLAN A121