CODE SUMMARY
SCOPE OF WORK
OFFICE REMODEL OF PREVIOUSLY BUILT -OUT OFFICE SPACE
PREVIOUS USE OF SPACE
BUSINESS)
OCCUPANCY CLASSIFICATION
BUSINESS)
CHANGE OF OCCUPANCY CLASS?
NO
TOTAL BUILDING AREA
29.777 SF/FLOOR
X
1 370RIES
=
89.331 SF
TOTAL PROJECT AREA
2,935 SF
SPACE TYPE AREA SF PER OCCUPANT
OCCUPLOAD
OCCUPANCY CALCULATIONS
NUMBER OF EXITS
GEN. OFFICE
2,935 SF
100
30
TOTAL OCCUPANTS IN PROJECTAREA
REQUIRED:I PROVIDED:I
30
SPRINKLERSYSTEM(YES/NO)
YES- EXISTINGTO REMAIN
TOTAL AREA OF ACCESSORY USES
0 SF
TOTAL AREA ON THE FLOOR
89,332 SF
ACCESSORYAREA EXCEEDS 10%
NO
FIRE WALLS, AND/OR OCCUPANCY
SEPARATIONS (IF REQUIRED)
N/A
ASHRAE 90.1 SUMMARY
EXEMPT (SEE REFLECTED CEILING PLAN)
BUILT BEFORE 1978?
NO
BUILDING CONSTRUCTION TYPE
II-B
LEGEND
Ep EXISTING ELECTRICAL PANEL LOCATION
EX EXISTING EXR. BUILDING STAIR LOCATION
Fe
FIRE EXTINGUISHER
®
EXITSIGN
— — —
TRAVEL DISTANCE
O
NIGHT LIGHT/EMERGENCY LIGHTING
NIEL
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VLtYI�tDwV�1D�
DATE: \ 10/16/19
r
LIFE SAFETY NOTES
1. PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED PER
NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED IF
THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN ON
PLAN ARE FOR REFERENCE ONLY.
2. PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DETECTORS, FIRE PULLS, AND ANY
OTHER REQUIRED ALARM & DETECTION SYSTEMS AS NECESSARY TO
MEET ALL APPLICABLE CODES (INTERNATIONAL BUILDING CODE,
INTERNATIONAL FIRE CODE, NFPA). IN RECEPTION AREAS,
CONFERENCE ROOMS AND OTHER HIGH PROFILE AREAS WITHIN SUITE,
ALL LOCATIONS OF SUCH DEVICES MUST BE APPROVED BY SDI OR
TENANT PRIOR TO INSTALLATION. FAILURE TO DO SO MAY RESULT IN
CONTRACTOR RELOCATING THESE ITEMS AT THEIR EXPENSE,
3. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA
10. COORDINATE WITH OWNER/LANDLORD ON EXTINGUISHER TYPE
AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY
POINT TO A VISIBLE EXTINGUISHER.
THE FOLLOWING NOTES APPLY ONLY IN EXISTING SPRINKLERED FACILITIES.
4. FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE A COMPLETE.
GENERAL NOTES
LI. REFER TO ARCHITECTURAL PLAN FOR WALL TYPE AND CONSTRUCTION
DETAILS.
L2. EXISTING COMMON CORRIDOR TO REMAIN, EXISTING EXITSIGNS, FIRE
PULLS, FIRE EXTINGUISHERS, ALARM NOTIFICATION APPLIANCES TO
REMAIN. RELOCATE EXISTING EXIT SIGNS, FIRE PULLS, FIRE
EXTINGUISHERS AND ALARM NOTIFICATIONS AS REQUIRED TO MEET
ALL LOCAL AND STATE CODES.
AREA NOT IN CONTRACT LIFE SAFETY PLAN
AREA OF WORK
0 2' 8' 4' 8' 8' 16'
THIS DRAWING, AND THE IDEAS,
DESIGNS AND CONCEPTS CONTAINED
HEREIN. ARE THE EXCLUSIVE
INTELLECTUAL PROPERTY OF SCH07
DESIGN, INC.. AND ARE NOT TO BE
USED OR REPRODUCED IN WHOLE, OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF SCH07 DESIGN.
0
M 00
W N
H NO
Ow
VNz
IMEM RRaRiiim LU
2 CL
V) N O
�O%aoz
a Q
La
M0
DO
N
ISSUE
DATE
DESCRIPTION
08.07.19
REVIEW SET
08.12.19
PERMITSET
08.29.19
CONSTRUCTION SET
REVISIONS
MAR=RI"ON
PROJECT NUMBER
2019.127
OJ.MGR DRAWN BY
AS/SDH MS/AMM
3RD FLOOR
LIFE SAFETY
L100