Loading...
HomeMy WebLinkAboutFP000 Fire Protection Risers(T)L ELEVATION VIEW OF RISER PLAN VIEW OF RISER FPI O SCALE: V"=16 FPLO �I_:_ SCALE: V I 0 -INDEX OF SHEETS~ SWEET DRAWING TITLE FPI.O FIRE PROTECTION R15ER AND DETAILS FP2.0 FIRE PROTECTION Tat FLOOR PLAN FP3.0 FIRE PROTECTION 2nd FLOOR PLAN FP4.0 FIRE PROTECTION 3rd FLOOR PLAN FP5.0 FIRE PROTECTION 4th FLOOR PLAN Isi FIRE PROTECTION 5th FLOOR PLAN FP1.0 FIRE PROTECTION STAIR PLAN FP8.0 FIRE PROTECTION STAIRWELL AND STANDPIPE DETAILS IN 1 • I:'I NO SCALE c. RELEASED FOR CONSTRUCTION Subject to compliance with all regulalions of State and meal Codes City d Camel (� yVm�tanrk4DA2+L DATE: \ 10/16/19 STANDPIPE FEED t RISER LEGEND OI (I) 4' AMES Mo. 'COLT-300' uV Ol GATE VALVES uJ BY PASS METER 0 (2) POTTER 094YSU TAMPER SWITCHES 0 (I) 4' GROOVED x FLANGED ADAPTER 0 (1) 6' RELIABLE Me. 'G' GROOVED CHECK VALVE 0 (2) 4' GIM. 90 ELBOW SHORT T.O. © (1) 4' POTTER Mo. 'VSR-6' FLOW SWITCH (WIRED BY OTHERS) O (I) 6'1 FLANGED REDUCING 99' ELBOW D.I. Qe (I) 6' GRVD. TEE SHORT T.O. Oq (I) 2' THIRD. 90 ELBOW IO (2) 6' GRVD. 90' ELBOW SHORT T.O. II (2) 6' POTTER MO. 'PBA-I206' ELECTRIC BELL (WIRED BY OTHERS) 12 (I) POTTER Mo. 'BBIC-I' WEATHERPROOF BACK30X (WIRED BY OTHERS) 13 (1) 12 HEAD, SPARE HEAD CABINET I4 (I) 2' BRASS GLOBE VALVE 15 (2) 4' PIPE STAND (1'-8' TO CENTERLINE) 16 (1) PRESSURE GAUGE SETTING (I) ks'xY THREADED BUSHING (1) VxO'-3' NIPPLE (1) V 3-WAY VALVE (1) V PLUG (1) PRESSURE GAUGE - 300 psi N COUPLINGS 4 MISS. ss 6 6' GROOVED COUPLING I 6'1 REDUCING GROOVED COUPLING (5) 4' GROOVED COUPLING (1) 2' GROOVED COUPLING (3) 6' FLANGE KITS (1) 4' FLANGE KITS AREA I DEMAND AREA II DEMAND @ BASE OF RISER @ BASE OF RISER 211 @ 64.9psi 179.11 IN 45.7psi AREA III DEMAND [ARFA1V DEMAND @ BASE OF RISER @ BASE OF RISER 193Gpm @ Si75.5gTan @ 63.2Poi AREA V DEMAND AREA VI DEMAND @ BASE OF RISER @ BASE OF RISER 99.11 @ Si 751@ 147.7psi -GENERAL NOTES- - ALL PIPE, FITTINGS, VALVES, HANGER MATERIAL, SPRINKLER DEVICES AND ALARMS SHALL BE INSTALLED AND TESTED PER NFPA B (2010) It I.B.C. REST. - ALL PIPE 2" AND SMALLER SHALL BE CPVC PIPE W/ CPVC FITTINGS (U.N.O. OR DRY SYSTEM). - ALL STEEL PIPE 2' AND SMALLER SHALL BE THREADABLE LIGW WALL WITH CAST IRON FITTINGS (U.N.O.). - ALL STEEL PIPE 21i' AND LARGER SHALL BE SCHEDULE 10 STEEL PIPE W/ SHORT T.O. GROOVED FITTINGS AND COUPLINGS U.N.O.). - ALL PIPE DIMENSIONS ARE SHOWN FROM CENTER TO CENTER EXCEPT NUMBERS SHOWN IN PARENTHESIS WHICH ARE CUT LENGTHS. - BUILDING CONSTRUCTED OF CONCRETE, WOOD STUDS, OPEN -WEB WOOD TRUSSES, WOOD FLOORING, GYPSUM BOARD WALLS AND CEILINGS OR ACOUSTICAL CEILING TILE. - SPRINKLER DESIGN OF SYSTEMS WILL BE AS FOLLOWED: - THE DESIGN FOR AREA #1 HAS BEEN DETERMINED BY NFPA 13 (2010) LIGHT HAZARD (POOL) PER NFPA B (2010) SEC. A.5.2 - AREA fH POOL- WET SPRINKLER SYSTEM - EXT. GOV. SPRINKLER HEADS FIRST FLOOR DESIGN DENSITY: .IOWn per S.F. PER NFPA 13 (2010) FIGURE 112.3.1.1 DESIGN AREA: 1500 S.F. (AREA REDUCED TO 954 S.F.) HOSE ALLOWANCE: 1003pn PER NFPA 13 (2010) TABLE 11.2.5.1.2 MAX HEAD SPACING: 20'1 MAX. PER NFPA 13 (2010) TABLE 8.6.2.2.1(0) - THE DESIGN FOR AREA #2 HAS BEEN DETERMINED BY NFPA 3 (2010) LIGHT HAZARD (BREAKFAST) PER Ndi 13 (2010) SEC. A.5.3.1 - AREA #2 BREAKFAST- NET SPRINKLER SYSTEM - EXT. COV. SPRINKLER HEADS FIRST FLOOR DESIGN DENSITY: .IOgpm per S.F. PER NFPA 3 (2010) FIGURE 112.3.1.1 DESIGN AREA: ODD S.P. AREA REDUCED 40% PER NFPA I3(2010) SEC.II.2.32.3.1 THOSE HEAAUD SP CNG l8rx18' MAXPER . PER 13FRA (2010) 3)(201100) TABLE 8.6.22.1(o) - THE DESIGN FOR AREA #3 14AS BEEN DETERMINED BY NFPA 3 (2010) ORDINARY HAZARD (LAUNDRY) PER Nli 3 (2010) SEC. A.5.2 - AREA #3 LAUNDRY- WET SPRINKLER SYSTEM - Q.R. S.C. SPRINKLER HEADS - FIRST FLOOR DESIGN DENSITY: ill per S.F. PER NFPA 3 (2010) FIGURE 112.3.1.1 DESIGN AREA: 900 S.F. AREA REDUCED 40% PER NFPA 113(2010) SEC.11.2.32.3.1 HOSE ALLOWANCE: 10i PER NFPA 13 (2010) TABLE 11.2.3.1.2 MAX HEAD SPACING: 130 S.F. PER NFPA 3 (2010) TABLE 8.62.Z.I(b) - THE DESIGN FOR AREA #4 HAS BEEN DETERMINED BY NFPA 3 (2010) LIGHT HAZARD (ROOM) PER NFPA 13 (2010) SEC. A.5.2 - AREA #4 ROOM- WET SPRINKLER SYSTEM - RESIDENTIAL SPRINKLER HEADS DESIGN FLOW: I9 gpm Mnimun IN 18.1 psi Minimum FOR AREA FOR Fl RES 44 PENDENT PER MANUFACTURERS CUT SHEET UNDER FLAT CEILING - THE DESIGN FOR AREA #5 HAS BEEN DETERMINED BY NFPA 13 (2010) ORDINARY HAZARD (CORRIDOR) PER NFPA 3 (2010) SEC. A.5.2 - AREA #5 CORRIDOR- NET SPRINKLER SYSTEM - O.R. LISTED COV. SPRINKLER HEADS - FIFTH FLOOR DESIGN DENSITY: IOWpm per S.F. PER NFPA 3 (2010) FIGURE 112.3.1.1 DESIGN AREA: 75 LINEAR FEET MAX I ALLOWANCE: I00gpm PER NFPA 13 (2010) TABLE 11.2.3.1.2 DESIGN FLOW: 13 Ill Minmmum @ 7 psi Minimum FOR 75' MAX AREA FOR Fl RES 44 PENDENT PER MANUFACTURERS CUT SHEET UNDER FLAT CEILING - THE DE51GN FOR AREA #6 HAS BEEN DETERMINED BY NFPA 13 (2010) - AREA #6 STANDPIPE- NET SYSTEM DESIGN PRE55URE: IOOpsi AT TOP OF RISER DESIGN AREA: 2 STANDPIPES NOSE ALLOWANCE: 750gpn PER 111 3 (2010) TABLE 11.2.3.1.2 DESIGN FLOW: SOO gpn FOR FIRST + 250 PER ADDITIONAL S.P. - ALARMS SHALL MEET IBC REQUIREMENTS WIRED BY OTHERS) - U\G SHALL BE FLUSHED 4 TESTED BEFORif RISER 4 SYSTEM ARE CONNECTED TO FLANGED SPIGOT. (BY OTHERS) -FLOW TEST DATA - DATE: 3 DECEMBER 2018 STATIC: 77 psi RESIDUAL: 73 psi FLOW: ISO() gpn PITO: 60 psi (1-2k4" OUTLET) A COEFFECIENT SIZE OF MAIN: 18" WATER MAIN SOURCE OF INFO: CITY OF CARMEL -WATER DIVISION - LOCATION: OLD MERIDIAN STREET HYDRANT GAUGED: let HYDRANT SOUTH WEST OF SITE ON OLD MERIDIAN HYDRANT FLOWED: let HYDRANT NORTH EAST OF SITE ON OLD MERIDIAN Q cQ Q SAN rxG -QI MECH. a) M?I i4P R-4 Ott. 16 P 5 . 2-0 VI' 3 7 2 21_21 ' s o- 6 9 S GALV. 2 ELEVATION VIEW OF RISER FPI.O SCALE:'=I'-0' -SPRINKLER LEGEND~ DENOTES GROOVED COUPLING � DBY/TE5 HANGER AND HANGER DETAIL i0 REFERENCE DENOTES RISE ON THE RUN YDENOTED DOWN ON THE RUN '1— DENOTES RISER NIPPLE OR DROP NIPPLE DENOTES FLOOR FEED LOCATICN Ill DENOTES NET RISER LOCATION DENOTES NEW 207 O.R. S.0 OVATE SEMI -RECESSED PENDENT DENOTES NEW Q.R. S.0 WHITE SEMI -RECESSED PENDENT I� DENOTES NEW Q.R. LISTED COV. WHITE SEMI -RECESSED PENDENT 0— DENOTES NEW Q.R. S.C. BRASS UPRIGHT IN— DENOTES NEW Q.R. LISTED COV. WHITE SEMI -RECESSED SIDEWALL D'— DENOTES NEW Q.R. S.C. BRASS SIDEWALL 0— DENOTES NEW Q.R. S.0 WHITE PENDENT COKEALOR 0— DENOTES NEW Q.R. LISTED COV. WHITE SEMI -RECESSED PENDENT ® DENOTES HYDRAULIC NODE -2561 DENOTES CENTERLINE OF PIPE TO BOTTOM OF DECK H - DENOTES CENTERLINE OF PIPE TO FINISH F.R. DENOTES ROOM NAME (PRICE DENOTES ROOM NUMBER e&�DENOTES CEILING HEIGHT FROM FINISH FLOOR DENOTES TYPE OF CEILING -TOTAL- -SPRINKLER HEAD LEGEND- RELIABF hIODEL 'FI-56' WHITE PENDENT W/ SEMI-RECESED ESCUTCHEON 0 k ORF �' NPT 200E K'5.6 Q.R S.C. SIN: RA1414 VELl h10DEL 'FI-56' WHITE PENDENT W/ SEMI -RECESSED ESCUTCHEON C ORE ' NPT 155T Ka5.6 Q.R. S.C. SIN: RA1414 RELIABF MODEL 'FIFR-OREC' WHITE SEMI -RECESSED PENDENT 17/32' ORE ' NPT 155'F K'8.0 Q.R. EXT. COV. SIN: MENTZ RELIABF MODEL 'FI-FR' BRASS UPRIGHT C ' ORE ' NPT MET K,5.6 Q.R. STD. COV. SIN: RA1425 pq RELIABLE MODEL 'FI-RES 44' WHITE SEMI-RECE#D SIDEWALL 7/16' OFF k4' NPT I55'F K=4.4 Q.R. LISTED COV. SIN: R3531 RELIABLE MODEL 'Fl-56' WHITE SIDEWALL Fs� '�' ORF k' NPT 155'F 76T Q.R. STD. COV. SIN: R1435 y y RELIABLE MODEL "G5-56' WHITE PENDENT CONCEALOR y�F�W ku' ORF !z' NPT 155'F K=5.6 O.R. STD. COV. SIN: RA3415 RELIABLE MODEL "FI-RES 49' WHITE SEMI-RECE55ED PENDENT 7/I6' ORF ku' NPT 155'F K•4.9 Q.R. LISTED COV. SIN: R3516 TOTAL HEADS FOR PROJECT = 491 THE OWNER SHALL BE RESPOL TO MAINTAIN A TEMPERATURE 407 M HIGHER IN ALL AREAS WHERE WET SPRINKLER PIPE 15 NSTALLm. 131 oDaau Z Q CL U w (L W Cz n S. A. 0. -_ TTLE J W 2 U 1 9 7 VJ N 2 0 2 fo a Z Q az W Z w N Z Z � � < o Z v Z W 0 U Z 23 AUGUST 20M UEC<EJ 3Y'. K. L, P. LCA 2AC-02. MEYER NAJEM FIRE PROTECTION RISER PLAN SHEET NUMBER FASTEVEOSTEVEO\I-5634.D145 FP1w0o