HomeMy WebLinkAboutFP002 Fire Standpipe Stair 2i (Z) PLAN VIEW OF STAIR 2 •0 SCALE: Vol'-O' FIRST FLOOR i I �I - - - - - - Ip�==== ___ ---- --- ---- --- ____ = oN = DI --- ----------- y UP s #2 \ 381 / IVGANG,DRAIN i I! (�P:) PLAN VIEW OF STAIR 2 P4.0 SCALE: Y1=1'-0' THIRD FLOOR RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City d Camel (� yVm�tanli(WA2+L DATE: \ 10/16/19 C P PLAN VIEW OF STAIR 2 P3.0 SCALE: Val'-O' SECOND FLOOR -STANDPIPE LEGEND~ I (I0)2kA' x df NIPPLE 2 (10) gyp' HOSE VALVE (NATIONAL STANDARD THREAD) wV CAP t CHAIN 3 (4) 4' =ED CAP 4 (2) 4' GR�/ED TEE - SHORT RADIUS 5 (2) 4' GROOVED 9d ELBOW - SNORT RADIUS 6 (12) 4' R15ER CLAMP 7 (I) 2kp' GROOVED 9d ELBOW 8 (I) 2y1: GROOVED CHECK VALVE 9 (1) 2 ' POTTER Mo. 'V5R' FLOW SWITCH 10 (3) 2' THREADED 0'-60 NIPPLE II (1) 2yp' NIBCO Mo. 10-4761 GROOVED BUTTERFLY VALVE WITH 511 TAMPER SWITCH (WIRED BY OTHERS) 11 (3) 2' GROOVED 90' ELBOW (SHORT T.O.) (3) 2' TYCO Mo.'BFG-300' GROOVED BUTTERFLY VALVE WITH BUILT-IN TAMPER SWITCH (WIRED BY OTHERS) 4 (3) 2' NIBCO Ms. 'KT403WFP' THREADED BRASS CHECK VALVE (1) IV AGF Mo. '25W' TEST AND DRAIN I6 (3) 2' POTTER Mo. 'VSR-5' FLOW SWITCH (WIRED BY OTHERS) (1) IYp W THREADED 90 ELBOW I8 (2) 4' NIBOO Mo. 'GD-4765-8N' GROOVED BUTTERFLY VALVE WITH BUILT-IN TAMPER SWITCH (WIRED BY OTHERS) I (6) I' THREADED 9d ELBOW (3) I' AGF Mo. '2500' TEST AND DRAIN (2) I$'xh'xl' THREADED TEE (2) I$' THREADED 9d ELBOW (I) It' THREADED 45' ELBOW - GALVANIZED (5) IV R15ER CLAMP (6) NEW GAUGE SETTING (1) 04 THREADED BUSHING (I) '0-3' NIPPLE (I) Y1' 3-WAY VALVE (1) V PLUG (I) PRESSURE GUAGE - 300 psi ss COUPLINGS t MISC, ss (27) 4' GROOVED COUPLING (5) 2V GROOVED COUPLING (5) IYp' GROOVED COUPLING (3) I' GROOVED COUPLING -STANDPIPE GENERAL NOTES- - All PIPE, FITTINGS, VALVE, HANGER MATERIAL AND SPRINKLER DEVICES SHALL BE INSTALLED PER NFPA 14(2010) t I.B.C. REQUIREMENTS. - ALL PIPE 4' AND LARGER SMALL BE SCHEDULE 10 wV GROOVED FITTINGS AND COUPLINGS. - BUILDING NOT CLASSIFIED AS HIGH RISE PER NFPA 14(20I6) SECTION 3.3.7 (UNDER 75 FT. IN HEIGHT). - STANDPIPE SHALL BE A CLASS I MANUAL -WET DEFINED PER NFPA 14(2010) SECTION 3.3.17.5, ALLOWED PER SECTION 5.4.1.1. - STANDPIPES HAVE BEEN CALCULATED PER NFPA 14(ZOW) SECTION 7.10.1.2. - MINIMUM PRESSURE AT TOP OF STANDPIPE SHALL BE 100 PSI DETERMINED PER NFPA 14(2016) SECTION 7.8.1. - 2yp' HOSE VALVE THREADS SHALL BE APPROVED BY LOCAL FIRE DEPARTMENT. - THE WATER SUPPLY SHALL BE PROVIDED BY LOCAL FIRE DEPARTMENT PUMPER TRUCK WHEN THE STANDPIPE SYSTEM IS PROVIDED WITH A FIRE DEPARTMENT CONNECTION PER NFPA 14(2016) SECTION 7.7.4 - ALARMS SHALL RE WIRED PER OR %� PLAN VIEW OF STAIR 2 t/J� PLAN VIEW OF STAIR 2 P6.0 SCALE: Ya =1'-0' FOURTH FLOOR 6.0 SCALE: Y4'=1'-O' FIFTH FLOOR ELEVATION VIEW OF STAIR 2 SCALE: 4 1'=1'-0" PARAPET LVL 3 n 65' - 10 3/4" Ll PARAPET LVL 2 n 611 1 114" PARAPET LVL 1 Q 60' - 1 1/8" ROOF LVL 55'-11112" U STAIR#2 5TH FLOOR n 44'-6Z STAIR#2 4TH FLOOR O 33' - 10" STAIR#2 3RD FLOOR O 23' - 2" STAIR#2 2ND FLOOR Q 12'-6" STAIR#2 1 ST FLOOR O 0" ELEVATION VIEW OF STAIR 2 SCALE: Y4'=1'-0' THE OWNER SHALL BE RESFM TO MAINTAIN A TEMPERATURE 407 OR NIWER IN ALL AREAS WHERE WET SPRINKLER PIPE 15 NSTAL D DONE l Y� J oon+EE g9hhII/000 p dl1YONE ODIN nm..0 lei Z Q O U w O (r D_ w W iE 2 3 4 5 6 7 SHE- TITLE. J W M2 fr Q U 9 7 m VJ W O 2 a z Q W C] Z LLI N Z z � � O < o z v z O LLI w Q Q O U Z 23 AUGUST 2019 UEL<EE 3Y K. L, P. LCA 2AG-02. MEYER NALEM FIRE PROTECTION STANDPIPE DETAILS (STAIR 2) SHEET NUMBER FASTEVEOASTEVEAI-5634.DWG �P7.0