HomeMy WebLinkAboutFP002 Fire Standpipe Stair 2i
(Z) PLAN VIEW OF STAIR 2
•0 SCALE: Vol'-O' FIRST FLOOR
i
I �I
- - - - - - Ip�==== ___
---- ---
---- --- ____
= oN = DI
--- ----------- y
UP s #2
\ 381 /
IVGANG,DRAIN i
I!
(�P:) PLAN VIEW OF STAIR 2
P4.0 SCALE: Y1=1'-0' THIRD FLOOR
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City d Camel (�
yVm�tanli(WA2+L
DATE: \ 10/16/19
C
P
PLAN VIEW OF STAIR 2
P3.0 SCALE: Val'-O' SECOND FLOOR
-STANDPIPE LEGEND~
I (I0)2kA' x df NIPPLE
2 (10) gyp' HOSE VALVE (NATIONAL STANDARD THREAD) wV CAP t CHAIN
3 (4) 4' =ED CAP
4 (2) 4' GR�/ED TEE - SHORT RADIUS
5 (2) 4' GROOVED 9d ELBOW - SNORT RADIUS
6 (12) 4' R15ER CLAMP
7 (I) 2kp' GROOVED 9d ELBOW
8 (I) 2y1: GROOVED CHECK VALVE
9 (1) 2 ' POTTER Mo. 'V5R' FLOW SWITCH
10 (3) 2' THREADED 0'-60 NIPPLE
II (1) 2yp' NIBCO Mo. 10-4761 GROOVED BUTTERFLY VALVE
WITH 511 TAMPER SWITCH (WIRED BY OTHERS)
11 (3) 2' GROOVED 90' ELBOW (SHORT T.O.)
(3) 2' TYCO Mo.'BFG-300' GROOVED BUTTERFLY VALVE
WITH BUILT-IN TAMPER SWITCH (WIRED BY OTHERS)
4 (3) 2' NIBCO Ms. 'KT403WFP' THREADED BRASS CHECK VALVE
(1) IV AGF Mo. '25W' TEST AND DRAIN
I6 (3) 2' POTTER Mo. 'VSR-5' FLOW SWITCH (WIRED BY OTHERS)
(1) IYp W THREADED 90 ELBOW
I8 (2) 4' NIBOO Mo. 'GD-4765-8N' GROOVED BUTTERFLY VALVE
WITH BUILT-IN TAMPER SWITCH (WIRED BY OTHERS)
I (6) I' THREADED 9d ELBOW
(3) I' AGF Mo. '2500' TEST AND DRAIN
(2) I$'xh'xl' THREADED TEE
(2) I$' THREADED 9d ELBOW
(I) It' THREADED 45' ELBOW - GALVANIZED
(5) IV R15ER CLAMP
(6) NEW GAUGE SETTING
(1) 04 THREADED BUSHING
(I) '0-3' NIPPLE
(I) Y1' 3-WAY VALVE
(1) V PLUG
(I) PRESSURE GUAGE - 300 psi
ss COUPLINGS t MISC, ss
(27) 4' GROOVED COUPLING
(5) 2V GROOVED COUPLING
(5) IYp' GROOVED COUPLING
(3) I' GROOVED COUPLING
-STANDPIPE GENERAL NOTES-
- All PIPE, FITTINGS, VALVE, HANGER MATERIAL AND SPRINKLER DEVICES
SHALL BE INSTALLED PER NFPA 14(2010) t I.B.C. REQUIREMENTS.
- ALL PIPE 4' AND LARGER SMALL BE SCHEDULE 10 wV GROOVED FITTINGS
AND COUPLINGS.
- BUILDING NOT CLASSIFIED AS HIGH RISE PER NFPA 14(20I6) SECTION 3.3.7
(UNDER 75 FT. IN HEIGHT).
- STANDPIPE SHALL BE A CLASS I MANUAL -WET DEFINED PER NFPA 14(2010)
SECTION 3.3.17.5, ALLOWED PER SECTION 5.4.1.1.
- STANDPIPES HAVE BEEN CALCULATED PER NFPA 14(ZOW) SECTION
7.10.1.2.
- MINIMUM PRESSURE AT TOP OF STANDPIPE SHALL BE 100 PSI DETERMINED
PER NFPA 14(2016) SECTION 7.8.1.
- 2yp' HOSE VALVE THREADS SHALL BE APPROVED BY LOCAL FIRE DEPARTMENT.
- THE WATER SUPPLY SHALL BE PROVIDED BY LOCAL FIRE DEPARTMENT PUMPER TRUCK
WHEN THE STANDPIPE SYSTEM IS PROVIDED WITH A FIRE DEPARTMENT CONNECTION
PER NFPA 14(2016) SECTION 7.7.4
- ALARMS SHALL RE WIRED PER OR
%� PLAN VIEW OF STAIR 2 t/J� PLAN VIEW OF STAIR 2
P6.0 SCALE: Ya =1'-0' FOURTH FLOOR 6.0 SCALE: Y4'=1'-O' FIFTH FLOOR
ELEVATION VIEW OF STAIR 2
SCALE: 4 1'=1'-0"
PARAPET LVL 3 n
65' - 10 3/4" Ll
PARAPET LVL 2 n
611 1 114"
PARAPET LVL 1 Q
60' - 1 1/8"
ROOF LVL
55'-11112" U
STAIR#2
5TH FLOOR n
44'-6Z
STAIR#2
4TH FLOOR O
33' - 10"
STAIR#2
3RD FLOOR O
23' - 2"
STAIR#2
2ND FLOOR Q
12'-6"
STAIR#2
1 ST FLOOR O
0"
ELEVATION VIEW OF STAIR 2
SCALE: Y4'=1'-0'
THE OWNER SHALL BE RESFM
TO MAINTAIN A TEMPERATURE
407 OR NIWER IN ALL AREAS
WHERE WET SPRINKLER PIPE 15
NSTAL D
DONE
l Y� J oon+EE
g9hhII/000
p dl1YONE
ODIN
nm..0
lei
Z
Q
O
U
w
O
(r
D_
w
W
iE
2
3
4
5
6
7
SHE- TITLE.
J
W
M2
fr
Q
U
9
7
m
VJ
W
O
2
a
z
Q
W
C]
Z
LLI
N
Z
z
�
�
O
<
o
z
v
z
O
LLI
w
Q
Q
O
U
Z
23 AUGUST 2019
UEL<EE 3Y
K. L, P.
LCA 2AG-02.
MEYER NALEM
FIRE PROTECTION
STANDPIPE DETAILS (STAIR 2)
SHEET NUMBER FASTEVEOASTEVEAI-5634.DWG
�P7.0