HomeMy WebLinkAboutA201-REFLECTED-CEILING-PLAN-Rev.0A.
O
O
O
O
CON
ROL
9' 412t,0"
®
2 8
O
O O O
MRI O
O
O I 1 1 0 1 1 1 0
O
O O O
O
EQUIPMENT ROOM
127
�90 O
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
DATE: 10/16/19
EXISTING WAITING
ID3
3 M
EJ
IV]
Reflected ClPlan
Scale: 1 /4" = V-0" mannian I
North
EXISTING
UNISEX
1 71
EXISTING VESTIBULE
iao
12 GAUGE
VERTICAL
HANGER
WIRE
PROVIDE
SEISMIC
BRACING
TEE
OF CEILING
MAIN
RUNNER
CEILING
CROSS TEE
03 Typical
Suspended Ceiling
Detail
A2D1 Not toScale
&S/8" METAL KICKERS AS
REQUIRED FOR BRACING.
3518" METAL STUD Q 16"
O.C. TO DECK ABOVE
518" GYPSUM WALLBOARD.
EXTEND 6" ABOVE FINISH
CEILING
FINISH CEILING - REFERENCE
REFLECTED CEILING PLAN
FINISH CEILING
REFERENCE R.C.P.
B.O. BULKHEAD
REFERENCE R.0P ..
REFERENCE•
R.C.P.
MTypical
Bulkhead Detail
201 Scale: 1" = l'0"
4
GENERAL CEILING NOTES
A. ALL WALLS EXTEND TO DECK UNLESS NOTED AS FOLLOWS:
6" WALLS TO 6" ABOVE CEILING HEIGHT
J_ WALLS TO JOISTS ABOVE
D_ WALLS TO DECK ABOVE
B. LIGHT FIXTURE AND DIFFUSERS ON DRAWINGS SHOWN FOR
LOCATION ONLY. COORDINATE WITH MECHANICAL AND
ELECTRICAL DRAWINGS FOR EXACT SPECIFICATIONS AND
VERIFICATION OF QUANTITY.
C. ALL CEILING ARE TO BE INSTALLED AT 9-0"UNLESS NOTED
OTHERWISE.
D. CENTER ACOUSTICAL CEILING PANELS IN EACH DIRECTION
WITH THE MAIN PORTION OF ANY ROOM OR SPACE, UNLESS
NOTED OTHERWISE.
CEILING LEGEND
"
GYPSUM BOARD
2X4 SUSPENDED ACOUSTICAL PANEL CEILING
J�
(REFERENCE FINISH SCHEDULE FOR TYPE)
2X2 SUSPENDED ACOUSTICAL PANEL CEILING
(REFERENCE FINISH SCHEDULE FOR TYPE)
2X2 HVAC DIFFUSER
❑
(REFERENCE MECHANICAL SCHEDULE)
2X2 HVAC RETURN AIR GRILLE
❑
(REFERENCE MECHANICAL SCHEDULE)
2X4 LED LAY -IN LIGHT FIXTURE
(REFERENCE ELECTRICAL SCHEDULE)
2X2 LED LAY -IN LIGHT FIXTURE
❑
(REFERENCE ELECTRICAL SCHEDULE)
STRIP LIGHT FIXTURE
®
RECESSED LED CAN LIGHT FIXTURE
0
LED PENDANT LIGHT FIXTURE
®
EXIT LIGHT FIXTURE
' ALL LIGHT FIXTURES ARE TO BE LED UNLESS NOTED
OTHERWISE.
CEILING PLAN NOTES
O1 NEW GYPSUM DRYWALL BULKHEAD LOCATION. ALIGN EDGE
OF BULKHEAD WITH ADJACENT WALLS.
O PROVIDE DIMMABLE FIXTURES AND CONTROLS.
O3 PROVIDE LOOSE LAID SOUND BATT INSULATION ALONG
PERIMETER OVER CEILING IN THIS AREA DO NOT PLACE
INSULATION OVER LIGHTS OR RETURN AIR DIFFUSERS.
® PROVIDE MEDICAL PRIVACY CURTAIN AND CEILING TRACK IN
THIS LOCATION. REFERENCE FINISH SCHEDULE FOR TEXTILE
SELECTION.
SO REPLACE EXISTING RECESSED CAN TRIM WITH LED
RETROFIT FIXTURE.
RESPONSIBILITY LEGEND
C.F.C.I.
CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
T.F.C.I.
TENANT FURNISHED, CONTRACTOR INSTALLED
V.F.C.I.
VENDOR FURNISHED, CONTRACTOR INSTALLED
LIGHT FIXTURE SCHEDULE
FIXTURE MANUFACTURER
STYLENUMBER
STYLE NAME
RESP.
F1 REFERENCE
ELECT.
GFC.I.
DRAWINGS
F2 REFERENCE
ELECT.
GF C.I.
DRAWINGS
F3 REFERENCE
ELECT.
GF C.I.
DRAWINGS
KEY PLAN North
T
7 :1
o
N P
w o
N C
a �
„ a^
W
h W
141
N ^ N
O�
Or
O 'o
all O
ac
ac N�
O Da at
LL +.. N
N vO
0
omi
w O M
F K L
CC
U C
Q u
3 z
3 coal
Co
CERTIFIED BY.
CalyRAmh
hwwrIOLmawmvns
am not �eto m aa++m mom a ,i nor
vion.�ofAr noma� a.aeme�o.�no,=na
33I,IGE , "psar
do
mi
* = AST9 W� 3 #
' t'• WOIPNP •.�
t�
V
manna
N
I
Q
N
CV
R
CO
Q
5
fa
-=
d
�
Li
_
Z
Z
E
M
i
cc
C.0
U
Oneanama
Z