HomeMy WebLinkAboutA500-DOOR-SCHEDULE-AND-DETAILS-Rev.0TWO (2) LAYER 518' GYPSUM
BOARD EACH SIDE, TYPICAL
SOUND BATT INSULATION
REFERENCE FLOOR PLAN
SEALANT CONTINUOUS @
PERIMETER, EACH SIDE
HOLLOW METAL DOOR FRAME
PAINTED. REFERENCE DOOR
SCHEDULE
SC WOOD DOOR SHOWN.
REFERENCE DOOR
SCHEDULE FOR DOOR
MATERIAL
STUD ANCHORS (2) SCREWS
MINIMUM, EACH ANCHOR
DOUBLE METAL STUD @
EACH HEAD 8 JAMB
J2 Jamb @ Rated Hollow Metal Frame
200 Scale: 3" = 1'-0"
ONE (1) LAYER 5'8" GYPSUM
BOARD EACH SIDE, TYPICAL
SOUND BATT INSULATION
REFERENCE FLOOR PLAN
SEALANT CONTINUOUS @
PERIMETER. EACH SIDE
ALUMINUM DOOR FRAME.
REFERENCE DOOR
SCHEDULE
Be WOOD DOOR SHOWN.
—
REFERENCE DOOR
SCHEDULE FOR DOOR
MATERIAL
STUD ANCHORS (2) SCREWS
MINIMUM, EACH ANCHOR
DOUBLE METAL STUD @
EACH HEAD 8 JAMB
MTailimpical Jamb C Interior Door
AS00 Scale: 3" = 1'-0'
RESILIENT WALL
BASE -RB1
05 Interior Elevation - C ARM 130
4
600 Scale: 1 /4" = 1'-0"
PI-1 VALANCE
PROVIDE FILLER PANEL
AS REQUIRED
KEYLESSI COMBINATION
LOCK; TYPICAL
Interior Elevation - Chang
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�NtYl�tDwYdND� -
DATE: \ 10/16/19
SOUND BATT INSULATION —
REFERENCE FLOOR PI -AN
TWO (2) LAYERS Win GYPSUM
BOARD EACH SIDE, TYPICAL
20 GAUGE BOX BEAM
2x TREATED WOOD HEADER @
EACH HEAD
SEALANT CONTINUOUS AT
PERIMETER, EACH SIDE
HOLLOW METAL DOOR FRAME
PAINTED. REFERENCE
SCHEDULES
Be WOOD DOOR SHOWN
REFERENCE DOOR SCHEDULE
FOR DOOR MATERIAL
H2 Head @ Rated Hollow Metal Frame
A500 Scale: 3" = V-0"
SOUND BATT INSULATION —
REFERENCE FLOOR PLAN
ONE (1) LAYER 5/8" GYPSUM —
BOARD EACH SIDE, TYPICAL
20 GAUGE BOX BEAM
2x TREATED WOOD HEADER @
EACH HEAD
SEALANT CONTINUOUS Q
PERIMETER, EACH SIDE
STUD ANCHORS (2) SCREWS -
MINIMUM, EACH ANCHOR
ALUMINUM DOOR FRAME. —
REFERENCE DOOR SCHEDULE
SC WOOD DOOR SHOM.
REFERENCE DOOR SCHEDULE
FOR DOOR MATERIAL
nTypical Head C Interior Door
A500 Scale: 3" = V-0"
Room 128
Nowt
RESILIENT WALL
BASE - RBI
DOOR AND HARDWARE SCHEDULE
NO.
ROOM NAME
SIZE
OPENING
FRAME
DETAIL
UL
RATING
HARDWARE
TYPE
REMARKS
MAT'L
ELEV.
GLASS
LOUV.
MAT'L
ELEV.
HEAD
JAMB
SILL
125
CONTROL
Tix8'1
WD
D1
-
-
AL
F1
H1
Ji
-
-
2
NO CLOSER
126
MRI
4'-6'x8'1
WD
D1
-
-
AL
F1
H1
Ji
-
-
2
RF SHIELDED DOOR I FRAME I HARDWARE
127
EQUIPMENT ROOM
4'-On x6'-0"
WD
D1
-
-
AL
F1
H1
Ji
-
-
4
128
CHANGING ROOM
3'-0"z8'-0"
WD
D1
-
-
AL
F1
H1
Ji
-
-
3
PROVIDE OCCUPIED I VACANT INDICATOR
129
PATIENT UNISEX
Tix 8'-0"
WD
D1
-
-
AL
F1
H1
11
-
-
3
PROVIDE OCCUPIED I VACANT INDICATOR
129
CARM
T6'z8'-W
WD
D1
-
-
AL
F1
H1
11
-
-
2
132
CORRIDOR
3'-0'z8'-0'
WD
Di
-
-
AL
Fi
Hi
Ji
-
-
2
133
STORAGE ROOM
6'-0'z8'-0'
WD
D1
-
-
AL
F2
Hi
J1
-
-
4
134
READING ROOM
3'-0'z 8'-0'
WD
D1
-
-
AL
F1
Hi
J1
-
-
5
135
STORAGE ROOM
3'-0'z 8'-0'
WD
D1
-
-
AL
F1
H1
J1
-
-
4
-
DOOR SCHEDULE NOTES:
1.
GENERAL PLAN NOTES
A. HARDWARE SUPPLIER TO VERIFY HARDWARE SCHEDULE
WITH OWNER
B. ALL DIMENSIONS ARE NOMINAL. GLAZING CONTRACTOR TO
SUBMIT SHOP DRAWINGS FOR REVIEW BY ARCHITECT.
C. ALL WOOD DOORS SHALL MATCH BUILDING STANDARD:
MARSHFIELD, WHITE BIRCH, ROTARY SLICED, MATCH
EXISTING STAIN.
D. FIELD VERIFY SIZE OF ALL WOOD DOORS TO BE INSTALLED IN
EXISTING DOOR FRAMES.
E. ALL HOLLOW METAL DOORS AND FRAMES ARE TO BE
HARDWARE LEGEND
AL - ALUMINUM T - TEMPERED
FR - FIRE RATED WD- WOOD
HIM - HOLLOW METAL GL - GLASS
PL - PLASTIC LAMINATE S - STEEL
IHARDWARE SCHEDULE I
1. PROVIDE BEST LOCKING SYSTEMS OR APPROVED EQUAL.
ALL HARDWARE FINISH TO BE US26D. PROVIDE CORES AND
SILENCERS AT ALL DOORS.
2. PROVIDE HARDWARE IN SETS ACCORDING TO THE
FOLLOWING SCHEDULE:
HARDWARE SET 1
EACH TO HAVE:
3 HINGES
1 LEVER LOCKSET(ENTRY)
1 WALLSTOP
HARDWARE SET
EACH TO HAVE:
3 HINGES
i LEVER LATCHSET(PASSAGE)
1 DOORCLOSER
1 WALLSTOP
HARDWARE SET
EACH TO HAVE:
3 HINGES
1 LEVER LOCKSET(PRIVACY)
1 OCCUPIED / VACANT INDICATOR
1 DOOR CLOSER
1 WALL STOP
HARDWARE SET
EACH TO HAVE:
3 HINGES
1 LEVER LOCKSET(STOREROOM)
1 DOOR CLOSER
1 WALL STOP
HARDWARE SET
EACH TO HAVE:
3 HINGES
1 LEVER LOCKSET (OFFICE)
1 WALL STOP
I DOOR TYPES I FRAME TYPES I STANDARD DOOR LOCATION I STANDARD FRAME I
DOORWIDTH
�I Ik
W
w
x
O
0
D1
03 Interior Elevation - MRI 126
A600 Scale: 1/4" 1'0"
DOOH
kPini
D2 oFaincii
i.
RESILIENT WALL J
BASE -RB1
ROUGH OPENING
N^ DOOR
wunT
O
z�
O M
0 0
F1
ROUGH OPENING
2' DOOR 2"
WIDTH
z r 18" MINIMUM C r
z CLEARANCE L
TO DOOR 4" MINIMUM w
p i CLEARANCE ¢
x ¢ TO DOOR <�
p0 CLEARANCE
2" SIB n
rc O TO DOOR
L —
F2
01 01
roo of
PL1
PLI VALANCE mi
W15 W30 W30
W30-
L1
L1
-
-Z
402room 03 LaJV —Lai In
no ]co
02 Interior Elevation - MRI 126
A600 Scale: 114" = V-0"
WOOD TRIM - STAIN TO �
MATCH WINDOWS
SHIELDED GLASS
WINDOW
RESILIENT WALL
BASE - RBI
PI-1
m oa
01 ]00 PROVIDE FILLER
PANEL AS REQUIRED
01 Interior Elevation - Control 125
ik A600 Scale: 1 /4" = 1'-0'
BRACKET (WHITE)
0
O N
0 Q
N
N C
a a
m a^
� • oD
` N W
N 0 N
O�
rao
Or
O o
� O
O N�
¢ CO
O g' CO
LL z N
N vai �
O cs
w OM
F OC
QL
2 p
U
¢ K
Q u
3 z
� 3 �
CERTIFIED BY.
m,L.o..o,mr,�u.mm.
wr L
am not to N mami in aT fom w m ,mr �.a
mosi.m,.rmne�inwnum•�n.,,eu cermno,ana
m0I\ 11GE I grygG'mi
* AR19600180
STATE OF —
1 i
WOIPNH,i
t�
V N
O
Q N CV
ca CO
Q -0 cc
O '-
Hno
V) t _
W LLB i
i> Z o a>
= Z E
cc
M i
O
la U
0 G
z
0
N_
ainnam
> O
LV m z
m o F
J zw"
U w
w
� 2 C
Li
6
Li
=a�
ULain Lu
af
m
QO
00
OZw
oao
SHEET No.
A500