Loading...
HomeMy WebLinkAboutCover-Sheet-Cover-Sheet-Rev.0NORTHWEST RADIOLOGY NETWORK TENANT EXPANSION IMPROVEMENT 10603 NORTH MERIDIAN STREET CARMEL, INDIANA 46290 i EXISTING v i EXIT / �IsnNc .XISTIN UNISEX 1 PATIENT Fall SHADED AREA \ soa.wAnlrc ®� 1 NOT IN PROJECT 1a SCOPE CONTROL O 1 ��� / FE r----- - ------ ---- \ r ❑ �� ❑ o 1 F IENi ou cw w �I MRI IS D©� / CARM WAITING , y �/ 1 T 1 1 WiI Olrvu use 0 'U \ STORAGE1a4 0 laa ; o , EQUIPMENTw FROOM 1 RE CORRIDOR 1 I 1immimAINmINNi>ININIMEM.LORRIRo y 1 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes 3, City d Camel IVM1��33tDN�(1DAAK DATE: 10/16/19 \ SHADED AREA NOT IN PROJECT SCOPE \ o ..". � Ei \ \ .q. 1 L I 1 sue° �. I"® 1 1 1 1NaUbb v OVERALL LIFE SAFETY PLAN North SCALE: 1 /8" = V-0" USE GROUP: GROUP B CONSTRUCTION TYPE: II-B EXISTING, SPRINKLERED ;© OWNER: MEP ENGINEER : STRUCTURAL ENGINEER HIM EYE CNOIN9aRATI Na'8ws'wMB.aoIo914`Iwv�k--LAHOHAi1Ve NORTHWEST RADIOLOGY NETWORK THE ENGINEERING CCLIAEORATIVE RANGASWAMY& ASSOCIATES, INC. 59M Technology Center Drive, 2410 Executive Drive, Suite 100 539 West Market Street. Suite 200 Indianapolis, Indiana 46278 Indianapolis, Indiana 46241 I-DuMAIIe, KY 40202 [P] 317.328.5050 [PI 317.636.M41 [PI 502.589.2212 ARCHITECT: EQUIPMENT VENDOR: CONTRACTOR: PHILIPS C�TAI.T �mI< MMMOmRMSUI,.a,MAa,,=INDANAa,.,e., ARCHITECTS FORUM PHILIPS HEALTHCARE NORTH AMERICA CATALYST CONSTRUCTION MANAGEMENT 8555 North River Road, Suite 220 2 Canal Petit 5158 E 65th SVeeL Indianapolis, Indiana 46240 Cambridge, Massachusetts 02141 Indianapolis, Indiana46220 [P] 317.842.8500 [P] 540.292.4196 [P] 317.579.1555 [F] 317.842ABg CODE INFORMATION SHEETINDEX APPLICABLE CODES: COVER SHEET/ CODE INFORMATION ALL WORK UNDER THIS CONTRACT SHALL COMPLY WITH THE STRUCTURAL PROVISIONS OF THE SPECIFICATIONS& DRAWINGS AND SHALL S100 SLABPLAN SATISFY ALL APPLICABLE CODES, ORDINANCES, A.D.A., AND REGULATIONS OF ALL GOVERNING BODIES INVOLVED. ARCHITECTURAL A001 OVERALL FLOOR PLAN ALL PERMITS AND LICENSES NECESSARY FOR THE PROPER A100 DEMOLITION PLAN EXECUTION OF THE WORK SHALL BE SECURED AND PAID FOR BY A200 FLOOR PLAN THE CONTRACTOR INVOLVED. A201 REFLECTED CEILING PLAN A202 FINISH PLAN THE FOLLOWING CODES AND REGULATIONS ARE CURRENTLY A203 FURNITURE AND EQUIPMENT PLAN ADOPTED BY THE STATE OF INDIANA AT THE TIME A BUILDING A220 ENLARGED RESTROOM PLAN AND ELEVATIONS PERMIT IS APPLIED FOR: A500 DOOR SCHEDULE AND DETAILS A700 CASEWORK SECTIONS AND DETAILS BUILDING CODE: INDIANA BUILDING CODE 2014 A701 CASEWORK SECTIONS AND DETAILS (INTERNATIONAL BUILDING CODE 2012 WITH INDIAINAAMENDMENTS) ELECTRICAL E201 ELECTRICAL LIGHTING PLAN MECHANICAL CODE: INDIANA MECHANICAL CODE 2014 E301 ELECTRICAL POWER PLAN (INTERNATIONAL MECHANICAL CODE 2012 E601 ELECTRICAL RISER DIAGRAM AND SCHEDULES WITH INDIANA AMENDMENTS) E602 ELECTRICAL SCHEDULES E701 ELECTRICAL SYMBOLS AND DETAILS ELECTRICAL CODE: INDIANA ELECTRICAL CODE W09 E901 ELECTRICAL SPECIFICATIONS (NATIONAL ELECTRICAL CODE 2008 - NFPA 70 WITH INDIANA AMENDMENTS) MECHANICAL M001 MECHANICAL SYMBOLS, ABBREVIATIONS, AND PLUMBING CODE: INDIANA PLUMBING CODE 2012 GENERAL NOTES (UNIFORM PLUMBING CODE 2") M201 Ell PLAN MD201 HVAC DEMOLITION PLAN FIRECODE: INDIANA FIRE CODE 2014 M601 HVAC SCHEDULES (INTERNATIONAL FIRE CODE 2012 M701 HVAC DETAILS WITH INDIANA AMENDMENTS) M901 HVAC SPECIFICATIONS ENERGY CODE: INDIANA ENERGY CONSERVATION CODE PLUMBING M10(ASHRAE 90.1- 2007 WITH INDIANA P201 PLUMBING PLAN AMENDMENTS) P601 PLUMBING SCHEDULES, DETAILS, AND SPECIFICATIONS FUEL GAS CODE: INDIANA FUEL GAS CODE 2014 (INTERNATIONAL FUEL GAS CODE 2012 MRI EQUIPMENT VENDOR WITH INDIANA AMENDMENTS) ENTIRE DRAWING SET ACCESSIBILITY CODE: INDIANA BUILDING CODE 2014, CHAPTER 11 (ICC/ANSI Al 17.1-2009 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES) PROJECT LOCATION CODESUMMARY BUILDING GROSS SQUARE FOOTAGE: EXISTING BUILDING (UNCHANGED) ±14.958 SF RENOVATION SQUARE FOOTAGE: TOTAL RENOVATION SF ±2,877 SF CONSTRUCTION TYPE: EXISTING.II-B, FULLY SPRINKLED (UNCHANGED) OCCUPANCY: OCCUPANCY CLASSIFICATION: GROUP B, EXISTING (BUSINESS) OCCUPANT CALCULATION (FIXED TABLE 1004.121: MAP RENOVATED SIP -2,955 SF/ 100 SF PER PERSON 30PERSONS IN EGRESS: LIFE SAFETY LEGEND 11105.3.2-.15" PER PERSON CAPACITY, SPRINKLERED EP ELECTRICAL PANEL LOCATION REQUIRED PROVIDED FIRST LEVEL- 30 OCCUPANTS X.15" 4.5" 116" EX EXIT- BUILDING STAIR LOCATION FIRST FLOOR MAXIMUM TRAVEL DISTANCE (TABLE 1016.2) = 300' FE FIRE EXTINGUISHER LOCATION IS OCCUPANCY WITH SPRINKLER) EXIT SIGNAGE LOCATION EMERGENCY LIGHTING wwwwwwaI PATH OF EGRESS, MAXIMUM TRAVEL DISTANCE Z Cw L UJ >1110 r Z O Z ri^Q^ W Q W a a O W Z