HomeMy WebLinkAboutE701-ELECTRICAL-SYMBOLS-&-DETAILS-Rev.0RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel (� yVm�tanrk�pl�xL DATE: \ 10/16/19 Electrical Symbols Legend Lighting 4'x4'recessed LED luminaire 0 LED downright 0 EM LED downright with emergency battery backup(slwlched) O MR LED down) ight 4' LED multi -purpose strip luminaire m ® Decorative pendant luminaire ® Call mounted LED exit sign Switches $ Single pole swich $3 Three-way switch $D Dimmer switch Three-way dimmer switch Wall switch type dual technology occupancy, sensor (with integral manual override switch and dimming capabildy). Refer to Manufacturers instructions for exact installation requirements prior to rough in. $� Wall switch type dual technology occupancy, sensor (with integral manual override switch). Refer to Manufacturers instructions for exact installation requirements prior to rough in. (0) -- Ceiling Mounted, Omni -directional type dual technology occupancy sensor (standard range). Refer to Manufacturers Instructions for exact Installation requirements prior to rough in. Ceiling mounted, Omni -directional type dual technology occupancy sensor (extended range). Refer to Manufacturers Instructions for exact Installation requirements prior to rough in. Ell Disconnect switch Power Duplex receplade(20 Amp rated) Quad receptace (20 Amp rated per duplex) 8 Ground fault interrupt receptacle(20 Amp raled) P Weatherproof, ground fault interrupt receptacle (20 Amp rated) with Whiledn-Use' caveat m 120/208V. panel board ® 277/480V. panel board QMotor connection ODry type transformer Fire and Communication F� Fire alarm duct detector e Telephone/data culled location,l' coral with pullwirs to above accessible ceiling Circuiting le� Conduit system concealed above ceiling Surface mounted conduit systern — — — Conduit system under floor Homerun. ConWA system to panel as noted on drawings © Junction box 0— Conduit up Conduit down 0— Notes 1. Switches shall be a maximum +4W A.F.F. to the top of the device unless otherwise noted on plans. 2. Receptacles, telephone cutlets, and television cutlets shall be a minimum of+18' A.F.F. to the bottom of the device unless otherwise noted on plans. 3. Not all symbols listed above are shown on plans. The symbol legend is used for reference of symbols sham on plans. See speclications for information related to symbols. Not Wall Switch > U and e st w 3 Switch n LU c AC Ballast Structure above Iet box Flexible IIIA' °d bsupport conduit by E.C. Ceiling T-bar 7 Ceiling 1 lj� LaY-in type Notes: fixture by E.C. Ceiling T-bar Lay -in type 1. Lighting fixtures must be supported light fixture independently of ceiling system. Upon written requesttothe engineer, other means of awpport will be considered for approval. 2. Light fixture shown may not depict specific attributes of fixture being Support clips (4 per figure). Plan View utilized in his project. Referto Like Cratl}rulay-inandlroXer Light Figure schedule for fixture lightfixturesuppoddips information. TYPICAL LAY -IN FIXTURE SUPPORT DETAIL Panel designation Ground conductor(s) (n used) Phase conductors) Neutral condudor(s) Switch leg or Go-between s All conductors#12 AWG AL1-1,3,5 otherwise noted Emergency Backup All conduit unless otherwise noted Circuit No. designation (Primary circuit only. Lamp leads not shown.) LIGHT FIXTURE WITH BATTERY BACKUP WIRING SCHEMATIC Connection to structural steel of Wilding (3) 3/4' copperweld 10' long ground rods 3/0 CU 3Po CU 10'Min. (Typ. for 3 or rod grounding field) GROUNDING DETAIL To dry transformer(s) Notes: 1. #12 AWG is min. conductor size except as noted. 2. 3/4' conduit is min. Size except as capacity permitting 24 volt control conductors and switchlegs may be in 1 /2' size, others as noted. 3. 12' is min. Flexsterel, Greenfield and Sealite size. KEY TO ELECTRICAL CIRCUIT WIRING 311) call Connection to cold water system 3/0 CU To concrete encased electrode (in min. of 2' concrete within or near bottom of foundation/footing with min. of 20'-T of bare copper conductor not smaller than #4 AWG.) Neutral Ws )S Disc. Link J At Main Distribution Panel "MDP" �/ Equipment ground Ws J\ / Surge arrestor 1 er matter Watt connections. Cold water pipe Note: E.C. shall follow this detail for proper grounding connections. 3/0 CU to water meter L 3/0 CU shunt around water matter W Z > ; Cr H LU Q LUcc & ?o om Z Q W J - J W o H U Ir 1 i r I CERTIFIED BY. ronemxr r. cyaeevmnkv..mrc.o�a•.a,k ao�u.me#k.kom,p�wm#mm me.pun. mpsa,a.kme.ap�m,mme,rra. e,.,.a,.e, nm,oansNoam.�ekrcr,nomnnewe.P�=m aenN miame kEyxemq[ellkem�rc. Our" STL� y��'"xc 9��,pfC35TEa�RTa`o N0. _* PE10100876 SqTA�T,EO�qF ort Q10 G\2Q'o S3/ Ni 0&30119 Z W W 00 �'cv _Ott N� E = rC MIN Z I_6 O L-0 W Z �; Q a—+ �2 o ri 0 Lf LUZ M Z Z %0 —a Q Z LU m_ Q M Z Li J m 0 m o 0 z w z w_ C z C Ilion J o Q w V �N o J W� WD o SHEET NO. E701