Loading...
HomeMy WebLinkAboutE4.0I it ii i COUIFEVq aFFIce u le COIIN9m x%e OFFICE O ..' it oOee m aFITOE e le I I I I HT I I I I /✓ /r r// /rr/rr///r //rr ////rr/� it///�,��/%%//j �.��r/� j%// j/ wuIELIN OFFICE 9 OFFICE 14 Has 1 x •/ j/ j jr/ r/ j// j j ;1 j/rjr, / _ r ... .. OFFICEOOFFICE it a RECEPTION s O Ia MAIL. p( rrax COUISIMIl ! OFFICE f �( ..... ..... m OFFICE a COINaEI„I © e u �xa wart xxe D III,T Oa-acl s 0 p� fnsErl �1717 L_i 177i� x1 �0 WAffM xmA-e OOLtABELM w�l LT. COIMaNO COUYFlIp s TILT. ORFCE a OFFCE 6 OFFICE a HALL 013111 I 17 COIMEuq NIFBELlAO COI NS9 aFFICE a OFFICE 2 OFFICE I oFnCE. ® ® ICU IT I I I ANNOTATION LEGEND "XN" DENOTES NEW WGTION OF EXISTING RELOCATED ("XR' DEVICE/EQUIPMENT. REWORK ALL BRANCH CIRCUIT WIRING, CONDUIT, ETC. TO NEW LOCATION AS REQUIRED. "XM" DENOTES EXISTING TO REMAIN ®KEYED NOTE SCHEDULE 1. CARD READER TO BE EITHER MOUNTED ON DOOR FRAME OR WALL ADJACENT TO FRAME FOR DOOR ACCESS CONTROL SYSTEM PROVIDED BY TENANT. IF MOUNTED ON WALL ADJACENT TO DOOR FRAME, PROVIDE A 3/4" CONDUIT WITH PULLWIRE AND INSULATING BUSHINGS FROM ABOVE ACCESSIBLE CEILING CONCEALED IN WALL DOWN TO 42" AFF FOR TENANTS SECURITY VENDOR USE. INSTALLER WELL PROVIDE REWIRED BOX/TRIM RING FOR READER. 2. PROVIDE 4'X8' PLYWOOD BACKBGARD PAINTED ON ALL SIDES WITH FIRE RETARDANT PAINT MOUNTED VERTICALLY ON WALL 3. COORDINATE EXACT LOCATION OF ALL DATA BACKBOX LOCATIONS WITH FURNITURE PUNS AND CRBE PROJECT MANGER PRIOR TO ROUGH —IN. (TYPICAL) 4. INTERCEPT EXISTING CIRCUIT ABOVE CEILING SERVING DEVICES TO REMAIN AND REWORK AS SHOWN. CONTRACTOR MAY RE —USE EXISTING BRANCH CIRCUIT TO SERVE NEW DEVICES. CIRCUIT NUMBERS ARE DIAGRAMMATIC. 5. PROVIDE NEW FIRE ALARM DEVICE SHOWN AND CONNECT TO FIRE ALARM LOOP SERVING SPACE. COORDINATE ALL WORK WITH BUILDING FIRE ALARM MAINTENANCE CONTRACTOR, 6. PROVIDE A NEW 25A/1P BREAKER IN AVAILABLE SPACE IN PANEL NOTED IN MAIN ELECTRIC ROOM. TYPE AND AIC RATING TO MATCH EXISTING. 7. CONNECT TO LIGHTING CIRCUIT AND CONTROL SERVING ROOM. GENERAL NOTES: N1NpN,E 10CaW Ci sE IC ROOK 'NID x J aaxo Follow salt mmauw rxT ucwm x nw rm. POWER PLAN III m T-0• 1. All DEVICES, EQUIPMENT, FIXTURES, EfC. MUST BE GROUNDED BY USE OF A PROPERLY SIZED GROUNDING CONDUCTOR. MECHANICAL/ELECTRICAL BONDS OF THE METAWC RACEWAY SYSTEM SHALL ALSO BE MAINTAINED. 2. BRANCH CIRCUIT WERE SIZES (AND CONDORS) SHALL BE INCREASED FROM THOSE INDICATED ON THE PUNS TO PREVENT EXCESSIVE VOLTAGE DROP. BRANCH CIRCUITS SHALL BE INSTALLED WITH WIRES OF SUFFICIENT SIZE SO THAT VOLTAGE DROP BETWEEN THE PANEL AND THE LOADS DOES NOT EXCEED A LIMIT OF 3%. 3. CIRCUITS MAY BE COMBINED IN CONCUR PROVIDED WIRE IS PROPERLY DERATED AND CONDUIT SIZED PER CODE. UNDER NO CIRCUMSTANCES SHALL MORE THAN NINE (9) CURRENT CARRYING CONDUCTORS BE RUN IN A SINGLE CONCUR. 4. ALL CONCURS SHALL CONTAIN A GROUND WIRE SIZED PER NEC TABLE #250-122. WHERE CIRCUIT CONDUCTORS ARE INCREASED IN SIZE FOR VOLTAGE DROP, THE GROUND WERE SIZE SHALL BE INCREASED PROPORTIONATELY (ACCORDING TO CIRCULAR MIL AREA) FROM THE SIZE REQUIRED BY NEC TABLE J250-122. 5. EXPOSED CONDUITS, WHERE PERMITTED, SHALL BE RUN PARALLEL TO OR AT RIGHT ANGLES TO BUILDING STRUCTURAL MEMBERS. 6. ALL WORK SHOWN UGHF IS EXISTING TO REMAIN. 7. ALL NEW DEVICES AND COVER PLATES SHALL BE WHITE UNLESS NOTED OTHERWISE. 8. ALL EXISTING DEVICES SHOWN TO REMAIN SHALL BE DISCONNECTED, REMOVED AND REPLACED WITH NEW WHITE DEVICES AND MATCHING COVERPLATES AND RECONNECTED TO EXISTING CIRCUIT. 0 U 0 a LLI m — 5«m — o a'O o< �Op 00 `m o y w o `? 6L Q m n omm mm ro aUw u Y W Z mmppgm / gi Coll =O 0 M aa u malwnutmn wawlen a I1Nm m of .erre we whInen Mmae M.atl rm.in the .,REDLY of m. as a nm ip wiN tlowo sa= at dmYP br mm0uoxn &,iiiiiiiinflivi la Cam aua xa e. awl. w.Mal lane w.xav raxlma xuuwl .raasedaaa wnn.n ..exam .1 want. e OYCnak, Art.11.0i. a V N W f- N a O ~ Q Liam Z till $ E = o w W > U_ < % 2 2 Z a % J lL J Z Z Wog CO F R N ABM 1711114 Cream ft ATD Oft re CBWO.2= ®aPERMIT RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Cannel (} ' N"Io l•111CA� DATE: 10/16/19 E4m0