HomeMy WebLinkAboutM1.0HANGER 14 MIN. STEEL ELBOW (j SECURE W/ DRAWBAND 4ROUND STEEL NOMINAL FEE)( DUCT,UCT W/SPIN-IN 24'x24' LAY -IN PANEL LENGTH 5'-TTING ANDOLUME DAMPER NECK/DUCT SECURE W/ SIZE DRAWBAND ROUND STEDIFFUSER EXTENSION NECK/D SIZEUCT f NOMINAL 24'x24' LAY -IN PANEL * DIMENSION SHOWN ON MECH PUN IS DUCT/NECK SIZE 1 LAY -IN DIFFUSER DETAIL N.T.S. INSULATION - BANKER WRAPPED AIR ROW w-D x 1.5� 14' MIN. L `III DURO-DYNE 'OPAX' VOLUME DAMPER NIL 1 TAKEOFF DETAIL 2RECTANGULAR DUCT BRANCH N.T.S. INSULATION - BLANKET WRAPPED AIR FLOW IN COLLAR FITTING WITH MASTIC AND TAPE YNE RB-25T APID VOLUME STEEL DUCT TAKEOFF DETAIL 3 ROUND DUCT BRANCH N.T.S. NOTE THREADED HANGER R SHEET ME SCREWS UNISTRUT ANGLE IRE NOTES: 1. ON DUCTS OVER 48' WIDE, BOTTOM SHALL BE BRACED BY ANGLEFOR CROSS SECTION AREA MORE THAN 8 SQ FT, DUCT SHALL BE BRACED BY ANGLES ON ALL FOUR SIDES. 2. CUTTING AND PATCHING SHALL BE UMIED TO A MINIMUM AS REQUIRED FOR PROPER INSTALLATION. 3. SUPPORTS SHALL BE SPACED AND SIZED AS PER SMACNA. 4 DUCT HANGER SUPPORT N:.5. EM TAPERED 45' ANGLE CONNECTION THIS DETAIL HAS TO BE USED WHEN DISTANCE L = 0.25 x W. BUT 4' MIN. BETWEEN BOX AND TAKE -OFF EXCEEDS 10 FEET. FOR SHORTER DISTANCES USE BELLAIOUTH TYPE FILLING WITH DIAMETER TO MATCH BOX INLET. UTILIZE ROUND TO OVAL TRANSITION WHEN BOX INLET IS OVAL MAIN RECTANGULM DUCT I I L SEE TERMINAL OR FAN BOX DETAIL TYPICAL 6) 5-0 CORRESPONDING RECTANGULAR SIZES Bx6 6"0 ROUND DUCT (VAV OR EQUIVALENT 10x8 8no BOX NECK SIZE) UNLESS SHOWN 12x10 10°0 DIFFERENTLY ON 14xl2 12"0 PUNS 16x14 14nO 18xl6 16"o 5 TAKE -OFF TO TERMINAL BOX N.T.B. PARALLEL FAN POWERED VAV BOX SCHEDULE (ELECTRIC REHEAT) MARK MANUFACTIWRER MODEL CFM RANGE MINIMUM CFM SETTING INLET DUCT SIZE QN.) FAN CFM ESP FAN HP HEATING CAPACITY (KW) HEATING EAT/LAT (7) NO. OF STEPS ELECTRICAL DATA POWER VOLT/PH MCA HOOP VAV 2-01(E) NALOR D35NE 150-750 280 8 400 0.25 1/10 4.0 - 2 277/1 15.6 20.0 5 VAV 2-11(E) NNLOR D35NE 150-750 280 8 400 0.25 1/10 4.0 - 2 277/1 15.6 20.0 5 VAV 2-12(E) NNLOR 035NE 250-1100 350 10 500 0.25 1/10 5.0 - 2 277/1 19.3 25.0 5 VAV 2-13(E) NNLOR D35NE 200-650 280 8 450 0.25 1/10 4.0 - 2 277/1 15.5 20.0 5 VAV 2-18(E) NNLOR D35NE 250-1000 350 10 500 0.25 1/10 5.0 - 2 277/1 19.3 25.0 5 VAV 2-19(E) NNLOR D35NE 250-900 350 10 550 0.25 1/4 5.0 - 2 277/1 19.8 25.0 5 VAV 2-24 NNLOR D35NE 250-1250 350 10 750 0.25 1/4 5.0 63.1/81.0 2 277/1 19.8 25.0 1,2.3,4 NOTES: 1. BALANCE TO AIRFLOWS INDICATED ON PUN. MINIMUM AIRFLOW SHALL BE USED DURING UNOCCUPIED HOURS. 2. PROVIDE UNIT WITH DISCONNECT. 3. FURNISH WITH DEC CONTROLLER TO COMPATIBLE WITH EXISTING BUILDING CONTROLS. 4. FAN TO ONLY OPERATE DURING NON -OPERATIONAL EQUIPMENT HOURS TO MAINTAIN UNOCCUPIED AIR TEMPERATURE 5. EXISTING FAN -POWERED VAV BOX TO REMAIN. SHOWN FOR REFERENCE ONLY. EXHAUST FAN SCHEDULE MARK !MANUFACTURER MODEL TOTAL CPM EAP. 'HAG RPM FWWATT POWER VOLT/PH BONES NOTES EF-1 GREENHECK SP-B150 100 0.5 1050 128W 277/1 2.0 1,2 NOTES: 1. PROVIDE WITH ARCHITECTURAL GRILLE, FAN SPEED CONTROLLER, VIBRATION ISOURON KIT, BACKDRAFT DAMPER AND DISCONNECT. 2. FAN TO BE INTERLOCKED TO OPERATE WITH ROOM LIGHTS. DIFFUSERS AND GRILLES MARK MANUFACTURER MODEL MATERIAL FRAME MAX NC NOTES CD-1 71TU5 OMNI STEEL 24'x24' LAY -IN 25 1 RG-1 TAUS 50F ALUMINUM 24'x24' LAY -IN 25 - NOTES: 1. OPPOSED BLADE DAMPER COMMON NOTES: 1. OPPOSED BLADE DAMPER 2. PROVIDE SQUARE TO ROUND NECK TRANSITIONS WHERE ROUND DUCTS SERVE SQUARE NECK DIFFUSERS OR GRILLES. 3. PROVIDE VOLUME DAMPER IN BRANCH DUCT RUNOUT WHERE CEILING IS ACCESSIBLE O.B. DAMPER BEHIND GRILLE OR DIFFUSER IS REQUIRED WHERE DUCT BRANCH IS INACCESSIBLE. . 4. PAINT INTERIOR OF DUCTWORK BEHIND GRILLES AND DIFFUSERS FLAT BUCK IF VISIBLE THROUGH DEVICE. 5. CONTRACTOR SHA L CONFIRM EXACT LOCATION OF DIFFUSERS AND GRILLES WITH GENERAL CONTRACTOR TENANT k ARCHITECT PRIOR TO ANY WORK. PAINT GRILLES WITH WHITE. MECHANICAL SYMBOL/ABBREVIATION LEGEND SYMBOL DESCRIPTION ABBREVIAT10N DESCRIPTION ® TEMPERATURE SENSOR AD ACCESS DOOR THERMOSTAT AL ACOUSTICAL UNING ® REMOTE TEST SWITCH CD CEILING DIFFUSER DUCT SMOKE DETECTOR CTE CONNECT TO EXISTING DDC DIRECT DIGITAL CONTROL END OF CONTRACT, CONNECT TO EXISTING EG EXHAUST GRILLE F FIRE DAMPER EAT ENTERING AIR TEMPERATURE M MOTORIZED DAMPER EF EXHAUST FAN VOLUME DAMPER ETR EXISTING TO REMAIN CEILING DIFFUSER FD FIRE DAMPER ZRG RETURN GRILLE FPC FIRE PROTECTION CONTRACTOR EG EXHAUST GRILLE GC GENERAL CONTRACTOR LAT LEAVING AIR TEMPERATURE -­Ar> AIRFLOW DIRECTION MCA MINIMUM CIRCUIT AMPICNY --L--> I LOUVERED DOOR MOD MOTOR OPERATED DAMPER Z� UNDERCUF DOOR MOCP MAXIMUM OVERLOAD PROTECTION CA OUTSIDE AIR SUPPLY RETURN/OA EXHAUST U� U� U� TURNING VANES UT \ SPIN -IN ANUALCBRANCH W/MAP ,DAMPE ` N; RA RETURN AIR RG RETURN GRILLE REX EXLOADNAMPS RU RUNNING RN ROOF TOP UNIT S4 SUPPLY AIR SR SUPPLY REGISTER MID MANIAC VOLUME DAMPER VOLUM VAV VARIBLE AIR VOLUME - GOND - A/C CONDENSATE DRAIN PIPING 0 0 a W m - 'n « m o a'O 1 ¢ ° ° p ow`m y w = ESL Q m n omN �bm wUw z W 04 c„i C m iM w~es ei mervice we give i, .MOAwIN.a remCti Ian eemwlY of Nlrlexls xmlml mnmems brlp N tlr we beaten 8,onsOe r wesew wm a., w s.+a norm i.n.s n.en w.meW rerAlma when expressed wnnee consent CI Neese e e Y C a sk, A C al l e a t. V a CM W F gJ TIS U) ec O W ~ J Z a W FU W 02 C7 U_ n < T a z C . J J Z w Z o KN O F N Room 14 9L41 Gan SK AM O! rp OM906 EDi P966T RELEASED FOR CONSTRUCTION Subject to compliance with all regulations at State and Local Codes City of Cannel �NrtV�\o'nQ1DA� DATE: 10/16/19 M1w0 MECHANICAL LEGEND, SCHEDULES, AND DETAILS