Loading...
HomeMy WebLinkAboutP1.01-1/2 SANITARY ISOMETRIC DIAGRAM NTS ]I11111u1-71\Den »_1\ W4" . T-W SPRINKLER SYSTEM SHALL BE RE —DESIGNED FOR NEW ROOM LAYOUT AND IS THE RESPONSIBILITY OF THE SPRINKLER COMRACTOR. PLUMBING FIXTURE CONNECTION SCHEDULE CONNECTIONS I RIC ITEM MAKE TIME MODEL TRIM TRAP STOPS REMARKS WASTE VENT HW CW WATER AMERICAN CADET PRO FLOOR MOUNTED, FLUSH TANK, WITH SLOW CLOSING HINGES OPEN FRONT SEAT. —1 CLOSET STANDARD 1.5 GPF 215AB.004 — INTEGRAL ANGLE 4` 2` — 1/2" COMPLETE WITH CADET FLUSHING SYSTEM AND EVERCLEAN SURFACE. FLUSH HANDLE SHALL BE MOUNTED ON TANK OPEN TO WIDE SIDE OF TOILET AREA AMERICAN HERITAGE WITH FLOOR MOUNTED CONCEALED ARM WALL CARRIER, FAUCET TO BE UV-1 LAVATORY STANDARD (0.5 GPM) NOTE /3 NOTE #4 1-1/2" 1-1/2" 1/2" 1/2" 5402.172V.002 WITH WRIST HANDLES PROVIDE WITH ASSE 1070 TEMPERING 4• CENTERS VALVE. SET AT 11CF. KRCHEN AMERICAN DRAIN — JUST NO. J-35, CRUMB CUP. FAUCET TO BE /7401.172H.002, GOOSE S-1 SINK ELKAY CELEBRITY GECR2521 STANDARD NOTE 13 NOTE /4 1-11Z 1-1/2" 1/2" 1/2" NECK WITH WRIST BLADE HANDLES. MOUNT AT AGA HEIGHT. PROVIDE WITH WATTS HERITAGE USG—B TEMPERING VALVE. SET AT 1117F. NOTES: 1. INSTALL SERVICE, SHUTOFF k CHECK VALVES, COCKS, STOPS, AIR CUSHIONS, VACUUM BREAKERS, AND SAFETY DEVICES WHERE REQUIRED BY CODE, SPECIFICATIONS, OR DRAWINGS. 2. ALL CATALOG NOS. REFER TO AMERICAN STANDARD UNLESS NOTED AND ALL FIXTURES IN WHITE UNLESS NOTED. 3. EXPOSED P—TRAPS TO BE 17 GA CHROME PLATE WITH CLEANOUT AND ESCUTCHEON PLATE. 4. STOPS TO BE CHROME PLATED 1/2" ANGLE VALVE WITH CHROME PLATED 12" LONG, 1/2" O.D. FLEXIBLE RISER AND ESCUTCHEON PLATE 5. ALL DRAINS AND WATER SUPPLY PIPING TO LAVATORIES TO BE INSULATED WITH 'HANDI LAV—GUARD' INSULATION KR BY TRUEBRO. PLUMBING SYMBOLS/ABBREVIATION LEGEND SYMBOL DESORPTION ABBREVIATION DESCRIPTION DOMESTIC HOT WATER A.F.F. ABOVE FINISH FLOOR DOMESTIC COLD WATER Gil COLD WATER SANITARY VENT GC GENERAL CONTRACTOR SANITARY SEWER HW HOT WATER C PIPE DROP PC PLUMBING CONTRACTOR 0— PIPE RISE SAM SANITARY PIPE BREAK V VENT SHUT—OFF VALVE ALL SYMBOLS AND ABBREVIATIONS ON THIS UST ARE NOT NECESSARILY USED ON THIS PROJECT. TEMPERED HW SUPPLY THERMOSTATIC TEMPERING I I CW SUPPLY VALVE, POWERS U HYDROGUARD SERIES LM495, ASSE 1070. SET AT 11CF HW SUPPLY STOP VALVES NC A. INSULATE ALL EXPOSED WASTE AND SUPPLY PIPING UNDER LAVATORIES WITH THE HANO—UV GUARD INSULATION KIT BY TRUEBRO OR EQUAL. 1 TEMPERING VALVE DETAIL NOT TO SCALE PLUMBING GENERAL NOTES: 1. PLUMBING CONTRACTOR SHALL FIELD VERIFY THE EXACT LOCATIONS AND SIZES OF ALL UTILITIES, PRIOR TO START OF WORK. THIS DRAWING IS NOT INTENDED TO INDICATE ALL EXISTING UTILITIES. 2. CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTING BID AND FIELD VERIFY EXISTING CONDITIONS TO ENSURE THAT THE WORK REPRESENTED ON THE DRAWINGS AND IN THESE SPECIFICATIONS CAN BE INSTALLED AS INDICATED. CONTRACTOR SHALL TAKE ALL INTERFERENCES INTO CONSIDERATION. IDENTIFY POTENTIAL INTERFERENCES WITH NEW WORK AND REPORT TO ARCHITECT IMMEDIATELY. PROVIDE ALL NECESSARY OFFSETS TO SUIT FIELD CONDITIONS AS REQUIRED. 3. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL APPLICABLE INDUSTRY STANDARDS OF GOOD PRACTICE AND SAFETY, AND THE MANUFACTURER'S STRICTEST RECOMMENDATIONS FOR EQUIPMENT AND PRODUCT APPLICATION AND INSTALLATION. 4. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND INSPECTIONS RELATED TO THE INSTALLATION OF THE WORK. 5. ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES, LAWS, ACTS AND ALL AUTHORITIES RAVING JURISDICTION AND LANDLORD'S CRITERIA, S. MAINTAIN ALL MANUFACTURER'S RECOMMENDED SERVICE CLEARANCES FOR ALL FIXTURES AND EQUIPMENT. REFER TO ARCHITECTURAL PUNS FOR EXACT LOCATIONS OF PLUMBING FIXTURES. 7. ALL HORIZONTAL FIRE PROTECTION SPRINKLER PIPING AND ALL ABOVE GRADE EXPOSED HORIZONTAL PIPING IS TO BE INSTALLED AS HIGH AS POSSIBLE SPRINKLER CONTRACTOR SHALL COORDINATE SPRINKLER SYSTEM WITH DUCTWORK AND TIGHTS, ALL COSTS ASSOCIATED WITH RAISING SPRINKLER PIPING WHERE THE ARCHITECTURAL DESIGN CAN NOT BE ACCOMPLISHED SHALL BE THE RESPONSIBILITY OF THE SPRINKLER CONTRACTOR. B. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCIES WITH THE CONTRACT DOCUMENTS BEFORE COMMENCING ANY WORK. 9. SLEEVE AND SEAL ALL PIPE PENETRATIONS OF WALLS AND FLOORS. APPLY INTUMESCENT FIRE SAFING COMPOUND AT PENETRATIONS OF FIRE —RATED WALLS, FLOORS AND CEILINGS, MAINTAINING INTEGRITY AND RATING OF FIRE SEPARATION. SLEEVES THROUGH FLOORS SHALL EXTEND 2" ABOVE FLOOR, BE GROUTED INTO PLACE AND WATERPROOFED. 10. ALL DOMESTIC COLD, HOT AND TEMPERED WATER PIPING TO BE INSULATED WITH RIGID FIBERGLASS INSULATION WITH TYPE ASJ' JACKET. COLD WATER PIPES AND TO HAVE 1/2" THICK INSULATION. DOMESIIC HOT AND TEMPERED WATER PIPES TO HAVE 1" THICK INSULATION. 11. PVC PIPING IS NOT ALLOWED EXCEPT FOR UNDERGROUND SANITARY UNES. 12. SPRINKLER HEADS WHICH OCCUR IN DRYWALL, MEAL AND ACOUSTIC CEILINGS ARE TO BE CONCEALED AND CUSTOM COLORED TO MATCH CEILING COLOR. Q CODED NOTES 1. INSTALL GUY GRAY PLASTIC ICE MAKER OUTLET BOX, IM-1. BEIIND REFRIGERATOR FOR ICE MAKER. IF WALL IS FIRE RATED, PROVIDE APPROPRIATE FIRE RATED OUTLET BOX. 1/2" CW DOWN. 2. EXTEND AND CONNECT CW TO NEAREST EXISTING CW PIPE 3/4" OR URGER. EXTEND AND CONNECT HW TO NEAREST EXISTING HW PIPE 1/2" OR URGER. FIELD VERIFY LOCATION AND SIZE OF EXISTING LINES PRIOR TO BID, PROVIDE NEW SHUT—OFF VALVES AT POINT OF CONNECTION IF NOT EXISTING. 3. EXTEND AND CONNECT SANITARY TO NEAREST EXISTING SANITARY STACK 3" OR LARGER. EXTEND AND CONNECT VENT TO NEAREST EXISTING VENT 2" OR LARGER. FIELD VERIFY LOCATION AND SIZE OF EXISTING UNES PRIOR TO BID. 4. 1/2" CW AND HW DOWN TO LAVATORY 5. 3/4" CW AND 1/2" DOWN TO WATER CLOSER AND SINK. 0 0 U a E11 m — co « m — o a'O o< �Op r00 `m o Wool Q mof Dom mom wUw UJ z W 04 g V D �® C m IW�We of service we given in MR did! ,node few is Me y of 4dApfbmt Aimsmot me,rmdr, design N tlr mmMM 8,onei WMYmsC~I bAnemAa PCM i Mow we Pauua.uwl "pressed donor mreem of weaen e o Y C r so. A C rl l a a f. U a ( W ® f- N 4 a 0 S S Z Q _ df{nt w (7 n n s® ILL U < 2 0 2 Z a = J d7 CC J Z Z 1111( RN w as 0 F- R N N@M14 9MI Oft rgn BWO.2= BD B PTBIBT RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Carmel '1;A TI DATE: 10/16/19 P1w0