HomeMy WebLinkAboutP1.01-1/2
SANITARY ISOMETRIC DIAGRAM
NTS
]I11111u1-71\Den »_1\
W4" . T-W
SPRINKLER SYSTEM SHALL BE RE —DESIGNED FOR NEW
ROOM LAYOUT AND IS THE RESPONSIBILITY OF THE
SPRINKLER COMRACTOR.
PLUMBING FIXTURE CONNECTION SCHEDULE
CONNECTIONS
I
RIC
ITEM
MAKE
TIME
MODEL
TRIM
TRAP
STOPS
REMARKS
WASTE
VENT
HW
CW
WATER
AMERICAN
CADET PRO
FLOOR MOUNTED, FLUSH TANK, WITH SLOW CLOSING HINGES OPEN FRONT SEAT.
—1
CLOSET
STANDARD
1.5 GPF
215AB.004
—
INTEGRAL
ANGLE
4`
2`
—
1/2"
COMPLETE WITH CADET FLUSHING SYSTEM AND EVERCLEAN SURFACE. FLUSH
HANDLE SHALL BE MOUNTED ON TANK OPEN TO WIDE SIDE OF TOILET AREA
AMERICAN
HERITAGE
WITH FLOOR MOUNTED CONCEALED ARM WALL CARRIER, FAUCET TO BE
UV-1
LAVATORY
STANDARD
(0.5 GPM)
NOTE /3
NOTE #4
1-1/2"
1-1/2"
1/2"
1/2"
5402.172V.002 WITH WRIST HANDLES PROVIDE WITH ASSE 1070 TEMPERING
4• CENTERS
VALVE. SET AT 11CF.
KRCHEN
AMERICAN
DRAIN — JUST NO. J-35, CRUMB CUP. FAUCET TO BE /7401.172H.002, GOOSE
S-1
SINK
ELKAY
CELEBRITY
GECR2521
STANDARD
NOTE 13
NOTE /4
1-11Z
1-1/2"
1/2"
1/2"
NECK WITH WRIST BLADE HANDLES. MOUNT AT AGA HEIGHT. PROVIDE WITH WATTS
HERITAGE
USG—B TEMPERING VALVE. SET AT 1117F.
NOTES:
1. INSTALL SERVICE, SHUTOFF k CHECK VALVES, COCKS, STOPS, AIR CUSHIONS, VACUUM BREAKERS, AND SAFETY DEVICES WHERE REQUIRED BY CODE, SPECIFICATIONS, OR DRAWINGS.
2. ALL CATALOG NOS. REFER TO AMERICAN STANDARD UNLESS NOTED AND ALL FIXTURES IN WHITE UNLESS NOTED.
3. EXPOSED P—TRAPS TO BE 17 GA CHROME PLATE WITH CLEANOUT AND ESCUTCHEON PLATE.
4. STOPS TO BE CHROME PLATED 1/2" ANGLE VALVE WITH CHROME PLATED 12" LONG, 1/2" O.D. FLEXIBLE RISER AND ESCUTCHEON PLATE
5. ALL DRAINS AND WATER SUPPLY PIPING TO LAVATORIES TO BE INSULATED WITH 'HANDI LAV—GUARD' INSULATION KR BY TRUEBRO.
PLUMBING SYMBOLS/ABBREVIATION LEGEND
SYMBOL
DESORPTION
ABBREVIATION
DESCRIPTION
DOMESTIC HOT WATER
A.F.F.
ABOVE FINISH FLOOR
DOMESTIC COLD WATER
Gil
COLD WATER
SANITARY VENT
GC
GENERAL CONTRACTOR
SANITARY SEWER
HW
HOT WATER
C
PIPE DROP
PC
PLUMBING CONTRACTOR
0—
PIPE RISE
SAM
SANITARY
PIPE BREAK
V
VENT
SHUT—OFF VALVE
ALL SYMBOLS AND ABBREVIATIONS ON THIS UST ARE NOT NECESSARILY USED ON THIS PROJECT.
TEMPERED HW SUPPLY
THERMOSTATIC TEMPERING I I CW SUPPLY
VALVE, POWERS U
HYDROGUARD SERIES
LM495, ASSE 1070. SET
AT 11CF
HW SUPPLY
STOP VALVES
NC
A. INSULATE ALL EXPOSED WASTE AND SUPPLY PIPING UNDER LAVATORIES WITH
THE HANO—UV GUARD INSULATION KIT BY TRUEBRO OR EQUAL.
1 TEMPERING VALVE DETAIL
NOT TO SCALE
PLUMBING GENERAL NOTES:
1. PLUMBING CONTRACTOR SHALL FIELD VERIFY THE EXACT LOCATIONS
AND SIZES OF ALL UTILITIES, PRIOR TO START OF WORK. THIS
DRAWING IS NOT INTENDED TO INDICATE ALL EXISTING UTILITIES.
2. CONTRACTOR SHALL VISIT SITE PRIOR TO SUBMITTING BID AND FIELD
VERIFY EXISTING CONDITIONS TO ENSURE THAT THE WORK
REPRESENTED ON THE DRAWINGS AND IN THESE SPECIFICATIONS CAN
BE INSTALLED AS INDICATED. CONTRACTOR SHALL TAKE ALL
INTERFERENCES INTO CONSIDERATION. IDENTIFY POTENTIAL
INTERFERENCES WITH NEW WORK AND REPORT TO ARCHITECT
IMMEDIATELY. PROVIDE ALL NECESSARY OFFSETS TO SUIT FIELD
CONDITIONS AS REQUIRED.
3. THE COMPLETED INSTALLATION SHALL BE IN ACCORDANCE WITH ALL
APPLICABLE INDUSTRY STANDARDS OF GOOD PRACTICE AND SAFETY,
AND THE MANUFACTURER'S STRICTEST RECOMMENDATIONS FOR
EQUIPMENT AND PRODUCT APPLICATION AND INSTALLATION.
4. THE CONTRACTOR SHALL OBTAIN AND PAY FOR ALL PERMITS AND
INSPECTIONS RELATED TO THE INSTALLATION OF THE WORK.
5. ALL WORK SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND
LOCAL CODES, LAWS, ACTS AND ALL AUTHORITIES RAVING
JURISDICTION AND LANDLORD'S CRITERIA,
S. MAINTAIN ALL MANUFACTURER'S RECOMMENDED SERVICE CLEARANCES
FOR ALL FIXTURES AND EQUIPMENT. REFER TO ARCHITECTURAL
PUNS FOR EXACT LOCATIONS OF PLUMBING FIXTURES.
7. ALL HORIZONTAL FIRE PROTECTION SPRINKLER PIPING AND ALL
ABOVE GRADE EXPOSED HORIZONTAL PIPING IS TO BE INSTALLED AS
HIGH AS POSSIBLE SPRINKLER CONTRACTOR SHALL COORDINATE
SPRINKLER SYSTEM WITH DUCTWORK AND TIGHTS, ALL COSTS
ASSOCIATED WITH RAISING SPRINKLER PIPING WHERE THE
ARCHITECTURAL DESIGN CAN NOT BE ACCOMPLISHED SHALL BE THE
RESPONSIBILITY OF THE SPRINKLER CONTRACTOR.
B. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND SHALL NOTIFY
THE ENGINEER OF ANY DISCREPANCIES WITH THE CONTRACT
DOCUMENTS BEFORE COMMENCING ANY WORK.
9. SLEEVE AND SEAL ALL PIPE PENETRATIONS OF WALLS AND FLOORS.
APPLY INTUMESCENT FIRE SAFING COMPOUND AT PENETRATIONS OF
FIRE —RATED WALLS, FLOORS AND CEILINGS, MAINTAINING INTEGRITY
AND RATING OF FIRE SEPARATION. SLEEVES THROUGH FLOORS
SHALL EXTEND 2" ABOVE FLOOR, BE GROUTED INTO PLACE AND
WATERPROOFED.
10. ALL DOMESTIC COLD, HOT AND TEMPERED WATER PIPING TO BE
INSULATED WITH RIGID FIBERGLASS INSULATION WITH TYPE ASJ'
JACKET. COLD WATER PIPES AND TO HAVE 1/2" THICK INSULATION.
DOMESIIC HOT AND TEMPERED WATER PIPES TO HAVE 1" THICK
INSULATION.
11. PVC PIPING IS NOT ALLOWED EXCEPT FOR UNDERGROUND SANITARY
UNES.
12. SPRINKLER HEADS WHICH OCCUR IN DRYWALL, MEAL AND ACOUSTIC
CEILINGS ARE TO BE CONCEALED AND CUSTOM COLORED TO MATCH
CEILING COLOR.
Q CODED NOTES
1. INSTALL GUY GRAY PLASTIC ICE MAKER OUTLET BOX, IM-1. BEIIND
REFRIGERATOR FOR ICE MAKER. IF WALL IS FIRE RATED, PROVIDE
APPROPRIATE FIRE RATED OUTLET BOX. 1/2" CW DOWN.
2. EXTEND AND CONNECT CW TO NEAREST EXISTING CW PIPE 3/4" OR
URGER. EXTEND AND CONNECT HW TO NEAREST EXISTING HW PIPE 1/2"
OR URGER. FIELD VERIFY LOCATION AND SIZE OF EXISTING LINES PRIOR
TO BID, PROVIDE NEW SHUT—OFF VALVES AT POINT OF CONNECTION IF
NOT EXISTING.
3. EXTEND AND CONNECT SANITARY TO NEAREST EXISTING SANITARY STACK
3" OR LARGER. EXTEND AND CONNECT VENT TO NEAREST EXISTING VENT
2" OR LARGER. FIELD VERIFY LOCATION AND SIZE OF EXISTING UNES
PRIOR TO BID.
4. 1/2" CW AND HW DOWN TO LAVATORY
5. 3/4" CW AND 1/2" DOWN TO WATER CLOSER AND SINK.
0 0
U
a
E11
m
—
co « m
—
o a'O
o<
�Op
r00
`m o
Wool
Q
mof
Dom
mom
wUw
UJ
z
W
04
g
V
D
�®
C
m
IW�We of service we given in
MR did! ,node few is Me y of
4dApfbmt Aimsmot me,rmdr,
design N tlr mmMM 8,onei
WMYmsC~I bAnemAa PCM
i Mow we Pauua.uwl
"pressed donor mreem of weaen
e o Y C r so. A C rl l a a f.
U
a
(
W
®
f-
N
4
a
0
S
S
Z
Q
_ df{nt
w
(7
n
n
s®
ILL
U
<
2
0
2
Z
a
=
J
d7
CC
J
Z
Z
1111(
RN
w
as
0
F-
R
N
N@M14 9MI
Oft rgn
BWO.2= BD B PTBIBT
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Carmel
'1;A TI
DATE: 10/16/19
P1w0