HomeMy WebLinkAbout05 ElevationsDESIGNED BY:Designed For:Mickey & Janie MaurerDate: 03-11-19 Plan number #1804041300 West 106th StreetPARTIAL FRONT ELEVATION
SCALE:1
4"=1'-0"
TOP OF MAIN
LEVEL7'-10"BOT. OF
WIN. HDR.VERIFY @ SITE ASPER EXISTING WINDOWSEXISTING
STRUCTURE
NEW
STRUCTURE
REMOVE EXISTING
MATERIAL & REPLACE
w/ STONE TO MATCH
12
8PITCH
STONE TO
MATCH
TOP OF MAIN
LEVEL
PARTIAL LEFT SIDE ELEVATION
SCALE:1
4"=1'-0"
REMOVE EXISTING
STONE SILL 7'-10"BOT. OF
WIN. HDR.VERIFY @ SITE ASPER EXISTING WINDOWSEXISTING
STRUCTURE
NEW
STRUCTURE
EXISTING
STRUCTURE
NEW
STRUCTURE
TOP OF MAIN
LEVEL
PARTIAL REAR ELEVATION
SCALE:1
4"=1'-0"
12
8PITCH
EXISTING
STRUCTURE
1 FRAMING SECTION
12
8PITCH 4'-0" 112" 1'-434" 10'-118" PHANTOM LINES
INDICATES REMOVE
EXISTING CEILING
FRAMING
NEW CEILING JST. VERIFY @ SITE 1'-618"20'-31
2" 2'-01
4"
12" INSUL.
BATTS R-38
10'-258"BOT. OF
LOOKOUTS
EXISTING RAFTERS
VERIFY @ SITE
PHANTOM LINES
INDICATES REMOVE
EXISTING EAVE
& VENEER
2x6 STUDS
16" O.C. w/
1
2" DRYWALL
FULL THK FRICTION
FIT FIBERGL INSUL.
BATTS R-19
30# ASPHALT SAT. FELT
OR EQUAL
1/2" O.S.B. SHEATHING
AIR SPACE
4" STONE VENEER
EXISTING BASEMENT
FOUNDATION WALL
CRAWLSPACE
3
4" PLYWOOD
SUB FLOOR
EXISTING 16" OPEN
WEB FLOOR JST.
MASTER
BATHROOM
HIS MASTER
CLOSET
INSUL.
BATTS
2 " RIGID INSUL.
20"x10" THK. CONC. FTG
W/(3)#4 BARS CONT.
W8x13#
STL. BEAM
VERIFY @ SITE MAT'L FOR
BEARING ATOP EXISTING
MASONRY LEDGE TO
SUPPORT NEW STEEL BEAM
12
8PITCH
4"
SEAT
CUT
9'-118"1'-0"EXISTING CEILING HGT.VERIFY @ SITEADD TO
FRAME WALL
10'-118"2
X
8
RAFTERS 24
"
o.c.3'-1012" 1'-43 4" 10'-11 8" 1'-61 8"13'-9" 2'-01
4"2'-1"
16" I JST @ 16" O.C.
10" CONC. WALL
w/#4 REBARS
16" o.c. BOTH WAYS
30# ASPHALT SAT. FELT
OR EQUAL
1/2" O.S.B. SHEATHING
AIR SPACE
4" STONE VENEER
3
4" PLYWOOD
SUB FLOOR
2x6 STUDS
16" O.C. w/
1
2" DRYWALL
12" INSUL.
BATTS R-38
FULL THK FRICTION
FIT FIBERGL INSUL.
BATTS R-19
10'-258"BOT. OF
LOOKOUTS
4" (MIN.) GRAVEL FILL
3" MIN. SLOPED
WEAR SLAB
CRAWLSPACE
ASPHALT SHINGLES
30# ASPHALT SAT. FELT
5/8" DECKING
INSUL.
BATTS
2 FRAMING SECTION
20"x10" THK. CONC. FTG
W/(2)#4 BARS CONT.
4" DIA. PERF
PIPE w/SOCK
WATERPROOFING AS
SPECIFIED BY GENERAL
CONTRACTOR
9'-10316"TOP OF
RIDGE BEAM
13'-9"
W8x13#
STL. BEAM
12
8PITCH
2X8 RAFTERS 24" o.c.HER MASTER
CLOSET
HIS MASTER
CLOSET
2X4
BRACING
24"o.c.
2X10 CEILING JST. 16" o.c.
4"
SEAT
CUT
4"
SEAT
CUT
3 2146GLENVIEWDR.
EVANSVILLE,IN47720
Telephone812-428-0174
Email designers@hgmccull ough.com
www.hgmccull ough.com
H. G. McCULLOUGH DESIGNERS, Inc . SHEET NUMBER"C 2002 H. G. McCullough Designers, Inc. All rights reserved There shall be NO reproduction
of this work, its technical aspects or creative content without the express written consent
of H. G. McCullough Designers, Inc. This work is fully protected by copyright under
U.S. copyright law and is strictly enforced by H. G. McCullough Designer, Inc."