HomeMy WebLinkAboutCLAY CORNER 38 - CC038 (AS DESIGNED)IECC 2909 Performance Compliance Property 1563 JENSEN ❑R CARMEL, IN 46032 Model: PENNINGTON (C) Community: CLAY CORNER 38 CC038 (AS DESIGNED) CLAY CORNER 38 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Design Heating Cooling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $1,288 $206 $385 $1,879 $670 $0 $2,549 Requirements C4405.3 Performance -based compliance passes by 9.8% R402.4.12 Air Leakage Testing C4402.5 Area -weighted average fenestration SHGG 402.5 Area -weighted average fenestration U-Factor 40322 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4D52 Duct Insulation C-M, Energy Solutions As Designed $1,138 $171 $385 $1,694 $670 $0 $2,364 Air sealing is 5.00 ACH at 54 Pa. It must not exceed 7.00 AGH at 5D Pa. design exceeds requirements for IECC 2009 Performance compliance by 9.8%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 9/19/19 at 8:43 AM Ekotrope RATER - Version 3.1.0.2256 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 1563 JENSEN DR CARMEL, IN 46032 Builder: LENNAR HOMES IT, [•TM Ceiling Attic, R-38 Above Grade Walls R-16 Foundation Walls NIA Framed Floor NIA Slab R-10.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.33, SHGC: 0.28 Building Features Duct Supply R-10.0, Return R-10.0 Duct Leakage to Outside 150 CFM25 (4.88 / 100 s.f.) Total Duct Leakage 240 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 95.5AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Electric • 0.93 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Matthew Timmons Organization: TSI Energy Solutions Signature: Date: 9i 19119 at 8:43 AM Ekotrope RATER - Version 3.1.0.225E 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property Organization 1563 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON (C) Community: CLAY CORNER 38 Builder LENNAR HOMES CC038 (AS DESIGNED) CLAY CORNER 38 General Building Information Conditioned Area (sq ft) 3,074 Conditioned Volume (cubic ft) 26,731 Insulated Shell Area (sq ft) 7,410 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab Name: SLAB(2,139 s.f., 217 ft. exterior perimeter) R-10 perimeter insulation, R-0 under slab insulation. Framed Floor None Present Foundation Wall None Present Above Grade Wall El Name: CON DIAM B 2X4 (2,413 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I El Name: CON DIGAR (180 s.f.) R-0 continuous insulation, R-13 cavity insulation Insulation Grade: I Name: CONDIATTIC (408 s.f.) R-3 continuous insulation, R-13 cavity insulation Insulation Grade: I Rim Joist Energy Code Inspection Checklist Property Organization 1563 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON (C) Community: CLAY CORNER 38 Builder LENNAR HOMES CC038 (AS DESIGNED) CLAY CORNER 38 El Name: BAND CONDJAMB (67 s.f.) R: 13.575 Roof Name: CON DfATTIC (64 s.f.) R: 13.575 Name: SECOND (2,139 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I Opaque Door Name: FRONT (24 s.f.) U: 0.182 Name: GARAGE (18 s.f.) U: 0.182 Glazing Inspection Status Results are projected 11 Name: FRONT (120 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH—WEST El Name: BACK (90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH—EAST Name: LEFT SIDE (93 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTHWEST El Name: LEFT SIDE GD (20 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH—WEST E] Name: RIGHT SIDE (73 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH—EAST Skylight None Present Mechanical Ventilation None Present C", Energy Solutions 2 Energy Code Inspection Checklist Property 1563 JENSEN DR CARM EL, IN 46032 Model: PENNINGTON (C) Community: CLAY CORNER 38 CC038 (AS DESIGNED) CLAY CORNER 38 Mechanical Equipment Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected 0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5AFUE M Air conditioner - Electric • 100% Cooling Load @ 13 SEER E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor Air Leakage Control ElTest Status: Blower -door tested House is air -sealed as to achieve 2,228 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. Duct Leakage Duct System 1 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 150 CFM25 (4.881 100 s.f.) Total Leakage specified as: 240 CFM25 (Post -Construction) C", Energy Solutions 3 Energy Code Inspection Checklist Property 1563 JENSEN DR CARM EL, IN 46032 Model: PENNINGTON (C) Community: CLAY CORNER 38 CC038 (AS DESIGNED) CLAY CORNER 38 Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Duct Leakage Code Requirements for IECC 2009 IECC: inspection Status Results are projected Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 5N5 4 Building Summary Property 1563JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [C] Community: CLAY CORNER 38 CCD38 (AS DESIGNED) CLAY CORNER 38 eneral Building Information Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES Inspection Status Results are projected Number Of Bedrooms 4 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 3,074 Unconditioned; attached garage? Yes Conditioned Volume [cu. ft.] 26,731 Total Units in Building 1 Residence Type Single family detached Floor Number Model PENNINGTON (C) Community CLAY CORNER 38 Climate Zone 5A Foundation Wall None Present Foundation Wall Library List None Slab Masonry Area C-M, Energy Solutions n SLAB R-10, 2'down 217 On Grade 0 0 2,139.0 ft' Exposed Exterior Conditioned Space Slab Library List Name Wall Construction Slab Completely Underslab Perimeter Perimeter Thermal Break Effective R-value Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value R-10, 2'down Wood Frame 1 Other No 0 2 10 No 0.00 Framed Floor None Present 1 Building Summary Property 1563JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [C] Community: CLAY CORNER 38 CCD38 (AS DESIGNED) CLAY CORNER 38 Fol Floor Library Rim Joist Name BAND CONDIAMB CONDIATTIC Rim Joist Library List Name G1 R-13, R-3.0 C-M Energy Solutions Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES G1 R-13, R3.0 67.0 ft' Exposed Exterior G1 R-13, R3.0 64.0 ft' Attic suiation R-value 13.575 Name Library Type Surface Color Surface Area Location CONDIAMB 2X4 G 1 R-13 BATT, R3.0 Medium 2,413.0 ft' Exposed Exterior CONDIATTIC G1 R-13 BATT, R3.0 Medium 408.0 ft' Attic CONDIGAR G1 R-13 Gar Walls Medium 180.0 ft, Unconditioned, attached garage Wall Library List jff"� Name Effective R-value G1 R-13 BATT, R-3-0 15.12 IG1 R-13 GarWalls 11.141 2 Building Summary Property Organization Inspection Status Energy C-M Solutions 1563 JENSEN DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON [C] Community: CLAY CORNER 38 Builder LENNAR HOMES CC❑38 (AS DESIGNED) CLAY CORNER 38 PG'lazin Name Library type Wall Assignment Foundation Wall Overhang Depth Overhang Ft To Overhang Ft To Orientation Surface Area Assignment Top Bottom BACK U-.33, SHGC-28 CONDIAMB 2X4 0 ❑ 0 Northeast 90.0 R2 FRONT U-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ Southwest 1200.f[2 LEFT SI DE U-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ Northwest 93.0 f[2 LEFT SIDE GD U-.33, SHGG28 CONDIAMB 2X4 0 0 ❑ Northwest 20.0 ft' RIGHT SI DE U-.33, SHGG28 CONDIAMB 2X4 0 0 0 Southeast 73.0 ft2 Glazing Library List E Name Shgc U-factor U-.33. SHGC-.28 0.28 0.330 Skylight -1W None Present Skylight Library List None Present Opaque Door Name Library Type Wall Assignment Foundation Wall Emittance Solar Surface Color Surface Area Location Assignment Ab sorpta n ce FRONT 24.0 fl2 Exposed Exterior Fiberglass Door CONDIAMB 2X4 0.9 0.75 Medium GARAGE 18.0 fl2 Exposed Exterior Fiberglass Door CONDIGAR 0.9 075 Medium Building Summary Property 1563JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [C] Community: CLAY CORNER 38 CC❑38 (AS DESIGNED) CLAY CORNER 38 FOpaque Door Library List Name Fiberglass Door Organization TSI Energy Solutions Matthew Timmons Builder LENNAR HOMES 0.182 Inspection status Results are projected C-M, Energy Solutions Roof Insulation Name Library type Attic Exterior Area [s.f.] Clay or Concrete Roof Surface Color Surface Area Location Tiles SECOND R-38 Blown, GR7 2,139 No Medium 2,139.0 ft' Attic Roof Insulation Library List _ Name Has Radiant Barrier R-38 Blown, GR1 No Whole House Infiltration Infiltration Measurement Type 5ACH at 50 Pa Blower -door tested Mechanical Ventilation _ None Present Lighting % interior Fluorescent % Interior LED Lighting % Exter Lighting ❑ 100 38.268 Shelter Class 4 a Fiuorescent i. extenor Leo ugntmg -A Garage Fluorescent Lighting Lighting 0 1❑0 ❑ 100 4 Building Summary Property Organization 1563 JENSEN DR TSI Energy Solutions CARMEL, IN 46032 Matthew Timmons Model: PENNINGTON [C] Community: CLAY CORNER 38 Builder LENNAR HOMES CC038 (AS DESIGNED) CLAY CORNER 38 nsite Generation None Present Onsite Generation Library Llst None Present Solar Generation None Present Solar Generation Library List None Present Conditioning Equipment Inspection Status Results are projected C-M, Energy Solutions Name Library lype Heating Percent Load Cooling Percent Load Hot Water Percent Load Location Airconditioner 4AC'42P 0% 100% 0% Conditioned Space Fuel -fired air 915SA4206OS17 100% 0% 0% Conditioned Space distribution Water Heating RE350' 0% 0% 100% Conditioned Space Equipment Type: 4AC*42P Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 46 A Building Summary Property 1563JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [C] Community: CLAY CORNER 38 CCD38 (AS DESIGNED) CLAY CORNER 38 Organization Inspection Status TSI Energy SClutions Results are projected Matthew Timmons Builder LENNAR HOMES quipment Type: 915SA4�U60S17 Fuel Type Natural Gas Distribution Type Forced Air Motor Type PSG (Single Speed) Heating Efficiency 95.5AFUE Heating Capacity [kBtulh] 58 Use default EAE No EAE [kWh] 636 rEuipment Type: RE350* Type bution Type Water Efficiency Capacity (gal.) Water Capacity [kBtulh] very Efficiency Electric Hydronic Delivery 0.93 Energy Factor 56 15.4 ❑.98 C-M, Energy Solutions Building Summary Property 1563JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [C] Community: CLAY CORNER 38 CCD38 (AS DESIGNED) CLAY CORNER 38 butivn System on Type -quipment -quipment Served Grilles luct R Value luct R Value Iuct Area [ftl ud Area 1ft9 to Outdoors Ikage Ikage Duct Test Conditions cult Flow Rate :ation Supply Area Return Area :ation Supply Area Return Area :ation Supply Area Return Area :ation Supply Area Return Area :ation Supply Area Return Area :ation Supply Area Return Area Ceiling Fan Has Ceiling Fan Cfm Per Watt Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Forced Air Fuel -fired air distribution Air conditioner 3074 3 10 10 829.98 461.1 150 CFM25 (4.88 1100 s.f.) 240 CFM25 Post -Construction Yes Conditioned Space 50 50 Attic (well vented; under insulation) 50 50 Conditioned Space 0 0 Conditioned Space Conditioned Space Conditioned Space No C-M, Energy Solutions 7 Building Summary Property 1563JENSEN DR CARMEL, IN 46032 Model: PENNINGTON [C] Community: CLAY CORNER 38 CCD38 (AS DESIGNED) CLAY CORNER 38 Organization Inspection Status TSI Energy Solutions Results are projected Matthew Timmons Builder LENNAR HOMES Water DlstrlbutlonMW� Water Fixture Type Use Default Hot Water Pipe Length Hot Water Pipe Length [ft] At Least R3 Pipe Insulation? Hot Water Recirculation System? Recirculation System Pipe Loop Length [ft] Drain Water Heat Recovery? Clothes Dryer Fuel Type Cef Field Utilization Clothes Washer Label Energy Rating Electric Rate Annual Gas Cost Gas Rate Capacity I mef ppliances and Controls Programmabie thermostat? Dishwasher Size Dishwasher Efficiency RangefOven Fuel Convection Oven? Induction Range? Refrigerator Consumption 5N5 Standard No 65 No No 30 No Electric Timer Controls 704 kWh[Year $0.081kWh $23.00 $0.581Therm 2.874 ❑.33053 Yes Standard 270 kWh Natural Gas No No 709 kWh[Year C-M, Energy Solutions ,3