HomeMy WebLinkAboutCLAY CORNER 38 - CC038 (AS DESIGNED)IECC 2909 Performance Compliance
Property
1563 JENSEN ❑R
CARMEL, IN 46032
Model: PENNINGTON (C)
Community: CLAY CORNER 38
CC038 (AS DESIGNED)
CLAY CORNER 38
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Design
Heating
Cooling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$1,288
$206
$385
$1,879
$670
$0
$2,549
Requirements
C4405.3 Performance -based compliance passes by 9.8%
R402.4.12 Air Leakage Testing
C4402.5 Area -weighted average fenestration SHGG
402.5 Area -weighted average fenestration U-Factor
40322 Duct Testing
Mandatory Checklist Mandatory code requirements that are not
checked by Ekotrope must be met.
R4D52 Duct Insulation
C-M,
Energy Solutions
As Designed
$1,138
$171
$385
$1,694
$670
$0
$2,364
Air sealing is 5.00 ACH at 54 Pa. It must not exceed 7.00 AGH at 5D Pa.
design exceeds requirements for IECC 2009 Performance compliance by 9.8%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date: 9/19/19 at 8:43 AM
Ekotrope RATER - Version 3.1.0.2256
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNETAccredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
1563 JENSEN DR
CARMEL, IN 46032
Builder: LENNAR HOMES
IT, [•TM
Ceiling Attic, R-38
Above Grade Walls R-16
Foundation Walls NIA
Framed Floor NIA
Slab R-10.0 Perimeter, R-0.0
Under
Infiltration 5 ACH50
Window U-Value: 0.33, SHGC: 0.28
Building Features
Duct Supply R-10.0, Return R-10.0
Duct Leakage to Outside 150 CFM25 (4.88 / 100 s.f.)
Total Duct Leakage 240 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 95.5AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Electric • 0.93 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspectedltested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Matthew Timmons
Organization: TSI Energy Solutions
Signature:
Date:
9i 19119 at 8:43 AM
Ekotrope RATER - Version 3.1.0.225E
2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
Energy Code Inspection Checklist
Property Organization
1563 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON (C)
Community: CLAY CORNER 38 Builder
LENNAR HOMES
CC038 (AS DESIGNED)
CLAY CORNER 38
General Building Information
Conditioned Area (sq ft) 3,074
Conditioned Volume (cubic ft) 26,731
Insulated Shell Area (sq ft) 7,410
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
Name: SLAB(2,139 s.f., 217 ft. exterior perimeter)
R-10 perimeter insulation, R-0 under slab insulation.
Framed Floor
None Present
Foundation Wall
None Present
Above Grade Wall
El Name: CON DIAM B 2X4 (2,413 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
El Name: CON DIGAR (180 s.f.)
R-0 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Name: CONDIATTIC (408 s.f.)
R-3 continuous insulation, R-13 cavity insulation
Insulation Grade: I
Rim Joist
Energy Code Inspection Checklist
Property Organization
1563 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON (C)
Community: CLAY CORNER 38 Builder
LENNAR HOMES
CC038 (AS DESIGNED)
CLAY CORNER 38
El Name: BAND CONDJAMB (67 s.f.)
R: 13.575
Roof
Name: CON DfATTIC (64 s.f.)
R: 13.575
Name: SECOND (2,139 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
Opaque Door
Name: FRONT (24 s.f.)
U: 0.182
Name: GARAGE (18 s.f.)
U: 0.182
Glazing
Inspection Status
Results are projected
11 Name: FRONT (120 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH—WEST
El Name: BACK (90 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH—EAST
Name: LEFT SIDE (93 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTHWEST
El Name: LEFT SIDE GD (20 s.f.), U: 0.330, SHGC: 0.28, Orientation: NORTH—WEST
E] Name: RIGHT SIDE (73 s.f.), U: 0.330, SHGC: 0.28, Orientation: SOUTH—EAST
Skylight
None Present
Mechanical Ventilation
None Present
C",
Energy Solutions
2
Energy Code Inspection Checklist
Property
1563 JENSEN DR
CARM EL, IN 46032
Model: PENNINGTON (C)
Community: CLAY CORNER 38
CC038 (AS DESIGNED)
CLAY CORNER 38
Mechanical Equipment
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
0 Fuel -fired air distribution • Natural Gas • 100% Heating Load @ 95.5AFUE
M Air conditioner - Electric • 100% Cooling Load @ 13 SEER
E] Water Heating • Electric • 100% Hot Water Load @ 0.93 Energy Factor
Air Leakage Control
ElTest Status: Blower -door tested
House is air -sealed as to achieve 2,228 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
Duct Leakage
Duct System 1
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 150 CFM25 (4.881 100 s.f.)
Total Leakage specified as: 240 CFM25 (Post -Construction)
C",
Energy Solutions
3
Energy Code Inspection Checklist
Property
1563 JENSEN DR
CARM EL, IN 46032
Model: PENNINGTON (C)
Community: CLAY CORNER 38
CC038 (AS DESIGNED)
CLAY CORNER 38
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Duct Leakage Code Requirements for IECC
2009 IECC:
inspection Status
Results are projected
Postconstruction Leakage Test: Duct Leakage to Outdoors t= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
5N5
4
Building Summary
Property
1563JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [C]
Community: CLAY CORNER 38
CCD38 (AS DESIGNED)
CLAY CORNER 38
eneral Building Information
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
Inspection Status
Results are projected
Number Of Bedrooms
4
Number Of Floors
2
Conditioned Floor Area [sq. ft.]
3,074
Unconditioned; attached garage?
Yes
Conditioned Volume [cu. ft.]
26,731
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
PENNINGTON (C)
Community
CLAY CORNER 38
Climate Zone
5A
Foundation Wall
None Present
Foundation Wall Library List
None
Slab
Masonry Area
C-M,
Energy Solutions
n
SLAB R-10, 2'down 217 On Grade 0 0 2,139.0 ft' Exposed Exterior Conditioned
Space
Slab Library List
Name Wall Construction Slab Completely Underslab Perimeter Perimeter Thermal Break Effective R-value
Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value
R-10, 2'down Wood Frame 1 Other No 0 2 10 No 0.00
Framed Floor
None Present
1
Building Summary
Property
1563JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [C]
Community: CLAY CORNER 38
CCD38 (AS DESIGNED)
CLAY CORNER 38
Fol Floor Library
Rim Joist
Name
BAND CONDIAMB
CONDIATTIC
Rim Joist Library List
Name
G1 R-13, R-3.0
C-M
Energy Solutions
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
G1 R-13, R3.0 67.0 ft' Exposed Exterior
G1 R-13, R3.0 64.0 ft' Attic
suiation R-value
13.575
Name
Library Type
Surface Color
Surface Area
Location
CONDIAMB 2X4
G 1 R-13 BATT, R3.0
Medium
2,413.0 ft'
Exposed Exterior
CONDIATTIC
G1 R-13 BATT, R3.0
Medium
408.0 ft'
Attic
CONDIGAR
G1 R-13 Gar Walls
Medium
180.0 ft,
Unconditioned, attached garage
Wall Library List
jff"�
Name
Effective R-value
G1 R-13 BATT, R-3-0
15.12
IG1 R-13 GarWalls
11.141
2
Building Summary
Property Organization
Inspection
Status
Energy
C-M
Solutions
1563 JENSEN DR TSI Energy Solutions
Results are projected
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON [C]
Community: CLAY CORNER 38 Builder
LENNAR HOMES
CC❑38 (AS DESIGNED)
CLAY CORNER 38
PG'lazin
Name Library type Wall Assignment Foundation Wall Overhang Depth
Overhang Ft To
Overhang Ft To
Orientation
Surface Area
Assignment
Top
Bottom
BACK U-.33, SHGC-28 CONDIAMB 2X4
0
❑
0
Northeast
90.0 R2
FRONT U-.33, SHGG28 CONDIAMB 2X4
0
0
❑
Southwest
1200.f[2
LEFT SI DE U-.33, SHGG28 CONDIAMB 2X4
0
0
❑
Northwest
93.0 f[2
LEFT SIDE GD U-.33, SHGG28 CONDIAMB 2X4
0
0
❑
Northwest
20.0 ft'
RIGHT SI DE U-.33, SHGG28 CONDIAMB 2X4
0
0
0
Southeast
73.0 ft2
Glazing Library List
E
Name Shgc
U-factor
U-.33. SHGC-.28 0.28
0.330
Skylight -1W
None Present
Skylight Library List
None Present
Opaque Door
Name
Library Type Wall Assignment Foundation Wall
Emittance Solar Surface Color
Surface Area Location
Assignment
Ab sorpta n ce
FRONT
24.0 fl2 Exposed Exterior
Fiberglass Door CONDIAMB 2X4
0.9 0.75 Medium
GARAGE
18.0 fl2 Exposed Exterior
Fiberglass Door CONDIGAR
0.9 075 Medium
Building Summary
Property
1563JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [C]
Community: CLAY CORNER 38
CC❑38 (AS DESIGNED)
CLAY CORNER 38
FOpaque Door Library List
Name
Fiberglass Door
Organization
TSI Energy Solutions
Matthew Timmons
Builder
LENNAR HOMES
0.182
Inspection status
Results are projected
C-M,
Energy Solutions
Roof Insulation
Name Library type Attic Exterior Area [s.f.] Clay or Concrete Roof Surface Color Surface Area Location
Tiles
SECOND R-38 Blown, GR7 2,139 No Medium 2,139.0 ft' Attic
Roof Insulation Library List _
Name
Has Radiant Barrier
R-38 Blown, GR1
No
Whole House Infiltration
Infiltration
Measurement Type
5ACH at 50 Pa
Blower -door tested
Mechanical Ventilation
_
None Present
Lighting
% interior Fluorescent % Interior LED Lighting % Exter
Lighting
❑
100
38.268
Shelter Class
4
a Fiuorescent i. extenor Leo ugntmg -A Garage Fluorescent
Lighting Lighting
0 1❑0 ❑ 100
4
Building Summary
Property Organization
1563 JENSEN DR TSI Energy Solutions
CARMEL, IN 46032 Matthew Timmons
Model: PENNINGTON [C]
Community: CLAY CORNER 38 Builder
LENNAR HOMES
CC038 (AS DESIGNED)
CLAY CORNER 38
nsite Generation
None Present
Onsite Generation Library Llst
None Present
Solar Generation
None Present
Solar Generation Library List
None Present
Conditioning Equipment
Inspection Status
Results are projected
C-M,
Energy Solutions
Name
Library lype
Heating Percent Load
Cooling Percent Load
Hot Water Percent Load
Location
Airconditioner
4AC'42P
0%
100%
0%
Conditioned Space
Fuel -fired air 915SA4206OS17 100% 0% 0% Conditioned Space
distribution
Water Heating RE350' 0% 0% 100% Conditioned Space
Equipment Type: 4AC*42P
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 46
A
Building Summary
Property
1563JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [C]
Community: CLAY CORNER 38
CCD38 (AS DESIGNED)
CLAY CORNER 38
Organization Inspection Status
TSI Energy SClutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
quipment Type: 915SA4�U60S17
Fuel Type
Natural Gas
Distribution Type
Forced Air
Motor Type
PSG (Single Speed)
Heating Efficiency
95.5AFUE
Heating Capacity [kBtulh]
58
Use default EAE
No
EAE [kWh]
636
rEuipment Type: RE350*
Type
bution Type
Water Efficiency
Capacity (gal.)
Water Capacity [kBtulh]
very Efficiency
Electric
Hydronic Delivery
0.93 Energy Factor
56
15.4
❑.98
C-M,
Energy Solutions
Building Summary
Property
1563JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [C]
Community: CLAY CORNER 38
CCD38 (AS DESIGNED)
CLAY CORNER 38
butivn System
on Type
-quipment
-quipment
Served
Grilles
luct R Value
luct R Value
Iuct Area [ftl
ud Area 1ft9
to Outdoors
Ikage
Ikage Duct Test Conditions
cult Flow Rate
:ation
Supply Area
Return Area
:ation
Supply Area
Return Area
:ation
Supply Area
Return Area
:ation
Supply Area
Return Area
:ation
Supply Area
Return Area
:ation
Supply Area
Return Area
Ceiling Fan
Has Ceiling Fan
Cfm Per Watt
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Forced Air
Fuel -fired air distribution
Air conditioner
3074
3
10
10
829.98
461.1
150 CFM25 (4.88 1100 s.f.)
240 CFM25
Post -Construction
Yes
Conditioned Space
50
50
Attic (well vented; under insulation)
50
50
Conditioned Space
0
0
Conditioned Space
Conditioned Space
Conditioned Space
No
C-M,
Energy Solutions
7
Building Summary
Property
1563JENSEN DR
CARMEL, IN 46032
Model: PENNINGTON [C]
Community: CLAY CORNER 38
CCD38 (AS DESIGNED)
CLAY CORNER 38
Organization Inspection Status
TSI Energy Solutions Results are projected
Matthew Timmons
Builder
LENNAR HOMES
Water DlstrlbutlonMW�
Water Fixture Type
Use Default Hot Water Pipe Length
Hot Water Pipe Length [ft]
At Least R3 Pipe Insulation?
Hot Water Recirculation System?
Recirculation System Pipe Loop Length [ft]
Drain Water Heat Recovery?
Clothes Dryer
Fuel Type
Cef
Field Utilization
Clothes Washer
Label Energy Rating
Electric Rate
Annual Gas Cost
Gas Rate
Capacity
I mef
ppliances and Controls
Programmabie thermostat?
Dishwasher Size
Dishwasher Efficiency
RangefOven Fuel
Convection Oven?
Induction Range?
Refrigerator Consumption
5N5
Standard
No
65
No
No
30
No
Electric
Timer Controls
704 kWh[Year
$0.081kWh
$23.00
$0.581Therm
2.874
❑.33053
Yes
Standard
270 kWh
Natural Gas
No
No
709 kWh[Year
C-M,
Energy Solutions
,3