HomeMy WebLinkAboutEnergy Code As DesignedIECC 2009 Performance Compliance
P ro pe rty
1180 WESTVALE ❑R
CARMEL, IN 46032
Model: CUSTOM
Community: JACKSONS GRANT 29.
JG298 (AS DESIGNED)
JACKSONS GRANT 298
Organization
TSI Energy Solutions
Devin Sielschott
Builder
EXECUTIVE HOMES
CONSTRUCTION, INC.
Design
Heating
Coaling
Water Heating
SubTotal - Used to determine compliance
Lights & Appliances
Onsite generation
Total
Inspection Status
Results are projected
Annual Energy Cost
IECC 2009 Performance
$2,671
$388
$232
$3,291
$1,383
$0
$4,675
Requirements
405.3
Performance -based compliance passes by 6.5%
®
R402.4.1.2
Air Leakage Testing
402.5
Area -weighted average fenestration SHGC
402.5
Area -weighted average fenestration LI-Factor
®
4032.2
Duct Testing
Mandatory Checklist
Mandatory code requirements that are not
checked by Ekotrope must be met.
R4052
Duct Insulation
C",Erergy Solutions
As Designed
$2,549
$296
$232
$3,077
$1,365
$0
$4,442
Air sealing is 5.00 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa.
Design exceeds requirements for IECC 2009 Performance compliance by 6.5%.
As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zane 5. If rating is Projected, I certify that the building design described herein is consistent with
the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been
inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party.
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 9117119 at 8:22 AM
Ekotrope RATER - Version 3.1.1.2253
IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
1180 WESTVALE DR
CARMEL, IN 46032
Builder: EXECUTIVE HOMES CONSTRUCTION, INC.
Ceiling Attic, R-38
Above Grade Walls R-15
Foundation Walls R-10
Framed Floor R-38
Slab R-0.0 Perimeter, R-0.0 Under
Infiltration 5 ACH50
Window U-Value: 0.29, SHGC: 0.23
Building Features
Duct Supply R-6.0, Return R-6.0
Duct Leakage to Outside 184 CFM25 (3.99 / 100 s.f.)
Total Duct Leakage 368 CFM25 (Post -Construction)
Heating Furnace • Natural Gas • 92.1 AFUE
Cooling Air Conditioner • Electric • 13 SEER
Water Heating Water Heater • Natural Gas • 0.96 Energy Factor
As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of
Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the
building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and
that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_
Name: Devin Sielschott
Organization: TSI Energy Solutions
Signature:
Date: 9/17/19 at 8:22 AM
Ekotrope RATER - Version 3.1.1.2253
2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm.
Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users.
Ekotrope disclaims all liability for the information shown on this report.
Energy Code Inspection Checklist
Property
Organization
1180 WESTVALE DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSDNS GRANT 29
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKSDNS GRANT 298
General Building Information
Conditioned Area (sq ft) 7,678
Conditioned Volume (cubic ft) 78,935
Insulated Shell Area (sq ft) 13,411
Inspection Status
Results are projected
C",
Energy Solutions
The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy
features will change in the field from what has been modeled. The inspection process should identify any changes and ensure
that the home continues to meet the applicable energy code.
Slab
] Name: BSMT(2,714 s.f., 249 ft. exterior perimeter)
R-0 perimeter insulation, R-0 under slab insulation.
Framed Floor
] Name: GARAGE (74 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
] Name: AMBIENT (72 s.f.)
R-0 continuous insulation, R-38 cavity insulation
Insulation Grade: I
Foundation Wall
] Name: COND/AMB (Exterior Perimeter [ft]: 157, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 9)
R: 9.696
Fully insulated (top to bottom)
] Name: CDNDIAMB UNFIN (Exterior Perimeter [ft]: 68, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 9)
R: 0.00
Fully insulated (top to bottom)
1l Name: CGNDIGARAGE (Exterior Perimeter [ft]: 16, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 9)
J--1 R:9.696
Fully insulated (top to bottom)
Energy Code Inspection Checklist
TSI Energy Solutions
Property Organization Inspection Status
1180 WESTVALE DR TSI Energy Solutions Results are projected
CARMEL, IN 46032 Devin Sielschott
Model: CUSTOM
Community: JACKSDNS GRANT 29 Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED) CONSTRUCTION, INC.
JACKSDNS GRANT 298
] Name: CON DIGARAGE UNFIN (Exterior Perimeter [ft]: 8, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 9)
R: 0.00
Fully insulated (top to bottom)
Above Grade Wall
1� Name: CON DIAMB (2,753 s.f.)
1--1 R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
1� Name: CGNDIAMB 2X6 (969 s.f.)
1--1 R-0 continuous insulation, R-19 cavity insulation
Insulation Grade: I
1� Name: CGNDIGAR (240 s.f.)
1--1 R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
] Name: CON DIATTIC (778 s.f.)
R-0 continuous insulation, R-15 cavity insulation
Insulation Grade: I
Rim Joist
] Name: CON DIAM B (326 s.f.)
R: 15.414
]l Name: CONDIGARAGE (24 s.f.)
R: 15.414
] Name: CON DIATTIC (111 s.f.)
R: 15.414
Roof
El Name: MAIN (2,860 s.f.)
R-27.55 continuous insulation, R-10.15 cavity insulation
Insulation Grade: I
2
Energy Code Inspection Checklist
P ro pe rty
1180 WESTVALE ❑R
CARMEL, IN 46032
Model: CUSTOM
Community: JACKSONS GRANT 29.
JG298 (AS DESIGNED)
JACKSONS GRANT 298
Opaque Door
Name: FRONT (48 s.f.)
U: 0.476
Name: FRONT (24 s.f.)
U: 0.476
El Name: GARAGE (24 s.f.)
U: 0.182
Glazing
Organization
TSI Energy Solutions
Devin Sielschott
Builder
EXECUTIVE HOMES
CONSTRUCTION, INC.
Inspection Status
Results are projected
Name: FRONT (213 s.f.), U: 0.290, SHGC: 0.23, Orientation: SOUTH
1� Name: FRONT 2X6 (88 s.f.), U: 0.290, SHGC: 0.23, Orientation: SOUTH
El Name: BACK (274 s.f.), U: 0.290, SHGC: 0.23, Orientation: NORTH
1] Name: GO (24 s.f.), U: 0.290, SHGC: 0.23, Orientation: NORTH
El Name: SLIDER (96 s.f.), U: 0.290, SHGC: 0.23, Orientation: NORTH
El Name: LEFT (25 s.f.), U: 0.290, SHGC: 0.23, Orientation: WEST
L] Name: LEFT 2X6 (88 s.f.), U: 0.290, SHGC: 0.23, Orientation: WEST
L] Name: RIGHT (72 s.f.), U: 0.290, SHGC: 0.23, Orientation: EAST
Name: BACK BSMT (15 s.f.), U: 0.290, SHGC: 0.23, Orientation: NORTH
E] Name: LEFT BSMT (30 s.f.), U: 0.290, SHGC: 0.23, Orientation: WEST
Skylight
None Present
CTMEnergy Solutions
3
Energy Code Inspection Checklist
Property
Organization
1180 WESTVALE DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSONS GRANT 29
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKSONS GRANT 298
Mechanical Ventilation
Inspection Status
Results are projected
Mechanical ventilation system rated for, and capable of, providing continuous ventilation.
System shall include automatic timing controls.
System type: ERV, 8 hrslday, 100 Watts.
Mechanical Equipment
FURNACE 1 • Natural Gas • 60% Heating Load @ 92.1 AFUE
FURNACE 2 • Natural Gas • 40% Heating Load @ 92.1 AFUE
El AC 1 • Electric • 60% Cooling Load @ 13 SEER
AC 2 • Electric • 40% Cooling Load @ 13 SEER
11 Water Heating • Natural Gas • 100% Hot Water Load @ 0.96 Energy Factor
Air Leakage Control
Test Status: Blower -door tested
House is air -sealed as to achieve 6,578 CFM50 (5.00 ACH50) or less at final blower -door test.
Infiltration Requirements for IECC in Climate Zone 5
2009 IECC Infiltration limit for the design home is 7 ACH50.
2012 IECC Infiltration limit for the design home is 3 ACH50.
2015 IECC Infiltration limit for the design home is 3 ACH50.
C",
Energy Solutions
4
Energy Code Inspection Checklist
Property
Organization
1180 WESTVALE DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSONS GRANT 29
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKSONS GRANT 298
Duct Leakage
Duct System 1
Inspection Status
Results are projected
All ducts and equipment within conditioned space
Leakage to Outside specified as: 184 CFM25 (3.99 / 100 s.f.)
Total Leakage specified as: 368 CFM25 (Post -Construction)
Duct System 2
NOT entirely within conditioned space, testing required
Leakage to Outside specified as: 150 CFM25 (4.88 / 100 s.f.)
Total Leakage specified as: 368 CFM25 (Post -Construction)
Duct Leakage Code Requirements for IECC
2009 IECC:
Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
2012 IECC and 2015 IECC Prescriptive Path:
Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA.
Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA.
Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA.
2015 Performance Path (Cost Compliance):
C",
Energy Solutions
Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope.
There is no pass/fail threshold for duct leakage on the performance path.
Project Notes
5
Building Summary
Property
Organization
Inspection Status
*Sl
Energy Solutions
118o WESTVALE DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSONS GRANT 298
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKSONS GRANT 298
General Building Information
Number Of Bedrooms
5
Number Of Floors
2
Conditioned Floor Area [sq. ft.]
7,678
Unconditioned; attached garage?
Yes
Conditioned Volume [cu. ft.]
78,935
Total Units in Building
1
Residence Type
Single family detached
Floor Number
Model
CUSTOM
Community
JACKSONS GRANT 298
Climate Zone
5A
Foundation Wall
Name Library type
Height Above Grade Depth Below Grade Perimeter Location
Enclosing
CONDIAMB R-11 Finished, G1
1
9
157 Exposed Exterior
Conditioned Space
CONDIAMB UNFIN Uninsulated
1
9
68 Exposed Exterior
Conditioned Space
CONDIGARAGE R-11 Finished, G1
1
9
16 Exposed Exterior
Conditioned Space
CONDIGARAGE Uninsulated
1
9
8 Exposed Exterior
Conditioned Space
UNFIN
Foundation Wall Library List
Name Feet From Wall Top To
Feet From Wall Top To Is Fully
Insulated Continuous R-value Cavity R-value
Effective Insulation R-
Continuous Insulation
Continuous Insulation
value
Top
Bottom
R-11 Finished, G1 NIA
NIA
Yes
N:.A N/A
9.696
Uninsulated NIA
NIA
Yes
N:.A N/A
0.00
Slab
Name Library Type
Perimeter Floor Grade
Carpet R Exposed
Surface Area Location Enclosing
Masonry Area
BSMT Uninsulated
249 Below Grade
0 0
2,714.0 ft' Exposed Exterior Conditioned
Space
1
Building Summary
Property
Organization
Inspection Status
118❑ WESTVALE DR
TSI Energy Solutions
Results are projected
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSONS GRANT 298
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKS0NS GRANT 298
Slab Library List
Name Wall Construction Slab Completel�r Underslab
Perimeter Perimeter
Type
Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value
Uninsulated Woad Frame
1 Other
No ❑
0 ❑
Framed Floor
JL—
M
Name
Library Type
Carpet R
Floor Grade !
AMBIENT
R-38. GR1
1
Above Grade
GARAGE
R-38. GR1
1
Above Grade
Framed Floor Library List
C"IEnergy Solutions
No ❑.00
ce Area t.ocatron
72.0 ft' Exposed Exterior
74.0 fI' Unconditioned. attached
garage
Name
Effective R-value
R-38, GR1
33.825
Rim Joist
Name
Library Type
Surface Area
Location
CONDIAMB
G1 R-19. OSB
326.0 fI1
Exposed Exterior
CONDIATTIC
G1 R-19. OSB
111.0 fI1
Attic
CONDIGARAGE
G1 R-19. OSB
24.0 fl'
Unconditioned, attached garage
Rim Joist Library List
Name Effective Insulation R-value
G1 R-19. OSB 15.414
Building Summary
Property
Organization
1180 WESTVALE DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSONS GRANT 298
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKSONS GRANT 298
Inspection Status
Results are projected
C"IEnergy Solutions
Name Library Type
CONDIAMB G1 R-15 BATT, OSB
Surface Color
Medium
Surface Area
2,753.0 ft'
Location
Exposed Exterior
CONDIAMB 2X6 G1 R-19, OSB 2x6
Medium
969.0 ft2
Exposed Exterior
CONDIATTIC G1 R-15 BATT, OSB
Medium
778.0 ft2
Attic
CONDIGAR G1 R-15 Gar Walls
Medium
240.0 ft'
Unconditioned, attached garage
Wall Library List
Name Effective R-value
G1 R-15 BATT. OSB 13.423
G1 R-15 Gar Walls 11.972
G1 R-19, OSB 2x6 17.591
Glazing
Name Library Type Wall Assignment Foundation Wall
Assignment
BACK U-.29. SHGC-.23 CONDIAMB
Overhang Depth Overhang
0
Ft Tb
Tap
0
Overhan_g Ft To
lJottom
0
Orientation
North
Surface Area
274.0 ft2
BACK BSMT U-.29. SHGC-23
CONDIAMB
0
0
0
North
15.0 ft2
FRONT U-.29. SHGC-23 CONDIAMB
0
0
0
South
213.0 ft2
FRONT 2X6 U-.29. SHGC-23 CONDIAMB 2X6
0
0
0
South
88.0 ft2
GD U-.29. SHGC-23 CONDIAMB
0
0
0
North
24.0 ft2
LEFT U-.29, SHGC-23 CONDIAMB
0
0
0
West
25.0 ft2
LEFT 2X6 U-.29, SHGC-23 CONDIAMB
0
0
0
West
88.0 ft,
LEFT BSMT U-.29, SHGC-23
CONDIAMB
0
0
0
West
30.0 fie
RIGHT U-.29. SHGC-23 CONDIAMB
0
0
0
East
72.0 ft2
SLIDER U-.29, SHGC-23 CONDIAMB
0
0
0
North
96.0 ft2
3
Building Summary
Property
Organization Inspection Status
118o WESTVALE DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSONS GRANT 298
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKSONS GRANT 298
Glazing Library List
i
Name Shgc U-factor
U-29, SHGC-.23 0.23 0.290
Skylight
Skylight Library List
None Present
None Present
Opaque Door
Name
Library Type Wall Assignment Foundation Wall
Assignment
FRONT
Wood Door CONDiAMB
FRONT
Wood Door CONDIAMB
GARAGE
FiberglasslSteel CONDIGAR
Door
Opaque Door Library List
Name
FiberglasslSteel Door
Wood Door
U-factor
0.182
0.476
C"IEnergy Solutions
Emittance Solar Surface Color Surface Area Location
Absorptance
0.9 0.75 Medium 48.0 fll Exposed Exterior
0.9
0.75
Medium
24.0 ft2
Exposed Exterior
0.9
0.75
Medium
24.0 fI1
Exposed Exterior
4
Building Summary
Property
1180 WESTVALE DR
CARMEL, IN 46032
Model: CUSTOM
Community: JACKSONS GRANT 298
JG298(AS DESIGNED)
JACKS0NS GRANT 298
Roof Insulation am
Name Library type
MAIN R-38 Blown, GRt
Roof Insulation Library List
Name Has
R-38 Blown, GRt
Whole House Infiltration
InfiRration Me;
5ACH at 50 Pa Blower -door tested
Organization
TSI Energy Solutions
Devin Sielschott
Builder
EXECUTIVE HOMES
CONSTRUCTION, INC.
No
2,860
Inspection Status
Results are projected
or concrete Roof surface Colol
Tiles
No Medium
Mechanical Ventilation IF
Ventilation Type Ventilation Rate [ft' 1 Operational hours perday
Minute]
E RV 200 8
Lightir
°4 Interior F
0
Gnsite Generation
80
0
38.268
4
C"IEnergy Solutions
2.860.0 fI' Attic
Fan Watts Runs once every three Energy Recovery Percent
hours
100 Yes E6
80
cent % Garage LED Lighting
sting
C 8C
5
Building Summary
Property
Organization
1180 WESTVALE DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSONS GRANT 298
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKSONS GRANT 298
Onsite Generation Library
List IM
None Present
Solar Generation
Solar Generation Library List
None Present
Inspection Status
Results are projected
C"IEnergy Solutions
Conditioning Equipment
Name Library type Heating Percent Load Cooling Percent Load
Hot Water Percent Load
Location
Ac " CA13NA042-A 0% 60%
0%
Conditioned Space
AC 2 CA13NA042-A 0% 40%
0%
Conditioned Space
FURNACE 1 912SA48100S17 60% 0%
0%
Conditioned Space
FURNACE 2 912SA48104S17 40% 0%
0%
Conditioned Space
Water Heating NPE-240A 0% 0%
100%
Conditioned Space
ment Type: 912SA4810OS1Le
Natural Gas
onType Forced Air
pe PSG (Single Speed)
fficiency 92.1 AFUE
F
apacity [kBtulh] 93ult
EAE N❑
h] 756
6
Building Summary
Property
Organization Inspection Status
118o WESTVALE DR
TSI Energy Solutions Results are projected
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSONS GRANT 298
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKSONS GRANT 298
uipment Type: CA13NA042-A
Fuel Type Electric
Distribution Type Forced Air
Motor Type PSG (Single Speed)
Cooling Efficiency 13 SEER
Cooling Capacity [kBtulh] 40
Equipment Type: NPE-240A
Fuel Type Natural Gas
Distribution Type Hydronic Delivery
Hot Water Efficiency 0.96 Energy Factor
Tankless? Yes
Hot Water Capacity [kBtulh] 1999.
Recovery Efficiency 0.99
C"IEnergy Solutions
Building Summary
Property
Organization
1180 WESTVALE DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSONS GRANT 298
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKS0NS GRANT 298
Distribution System
Distribution Type
Forced Air
Heating Equipment
FURNACE 1
Cooling Equipment
AC 1
Sq. Feet Served
4606
# Return Grilles
4
Supply Duct R Value
6
Return Dud R Value
6
Supply Duct Area [ftl
1243.62
Return Dud Area [ftq
921.2
Leakage to Outdoors
184 CFM25 (3.99 1100 s.f.)
Total Leakage
368 CFM25
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
100
Percent Return Area
100
Duct 2
Duct Location
Attic (well vented, under insulation)
Percent Supply Area
❑
Percent Return Area
❑
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Inspection Status
Results are projected
C"IEnergy Solutions
Building Summary
Property
Organization
1180 WESTVALE DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSONS GRANT 298
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKS0NS GRANT 298
Distribution System
Distribution Type
Forced Air
Heating Equipment
FURNACE 2
Cooling Equipment
AC 2
Sq. Feet Served
3072
# Return Grilles
4
Supply Duct R Value
20
Return Dud R Value
20
Supply Duct Area [ftl
829.44
Return Dud Area [ftq
614.4
Leakage to Outdoors
150 CFM25 (4.88 1100 s.f.)
Total Leakage
240 CFM25
Total Leakage Duct Test Conditions
Post -Construction
Use Default Flow Rate
Yes
Duct 1
Duct Location
Conditioned Space
Percent Supply Area
10
Percent Return Area
10
Duct 2
Duct Location
Attic (well vented, under insulation)
Percent Supply Area
90
Percent Return Area
90
Duct 3
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 4
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Duct 5
Duct Location
Conditioned Space
Percent Supply Area
0
Percent Return Area
❑
Duct 6
Duct Location
Conditioned Space
Percent Supply Area
❑
Percent Return Area
0
Ceiling Fan
Has Ceiling Fan
Cfm Per Watt
No
100
Inspection Status
Results are projected
C"IEnergy Solutions
Building Summary
Property
Organization
1180 WESTVALE DR
TSI Energy Solutions
CARMEL, IN 46032
Devin Sielschott
Model: CUSTOM
Community: JACKSONS GRANT 298
Builder
EXECUTIVE HOMES
JG298 (AS DESIGNED)
CONSTRUCTION, INC.
JACKS0NS GRANT 298
Water Distribution
Water Fixture Type
Standard
Use Default Hot Water Pipe Length
No
Hot Water Pipe Length [ft]
75
At Least R3 Pipe Insulation?
No
Hot Water Recirculation System?
No
Recirculation System Pipe Loop Length [ft]
20
Drain Water Heat Recovery?
No
Clothes Dryer
Fuel Type Electric
Cef 2.617
Field Utilization Timer Controls
INA
Label Energy Rating
704 kWh1Year
Electric Rate
$0.081kWh
Annual Gas Cost
$23.00
Gas Rate
$0.581Therm
Capacity
2.874
Imet
❑.331
ppliances and Controls
rogrammable thermostat?
Yes
ishwasher Size
Standard
ishwasher Efficiency
ID
270 kWhangefOven
Fuel
Electric
onvection Oven?
N❑
duction Range?
N❑
efrigerator Consumption
709 kVVhfYear
Inspection Status
Results are projected
C"IEnergy Solutions
10