HomeMy WebLinkAboutEnergy Code As DesignedIECC 2009 Performance Compliance P ro pe rty 1180 WESTVALE ❑R CARMEL, IN 46032 Model: CUSTOM Community: JACKSONS GRANT 29. JG298 (AS DESIGNED) JACKSONS GRANT 298 Organization TSI Energy Solutions Devin Sielschott Builder EXECUTIVE HOMES CONSTRUCTION, INC. Design Heating Coaling Water Heating SubTotal - Used to determine compliance Lights & Appliances Onsite generation Total Inspection Status Results are projected Annual Energy Cost IECC 2009 Performance $2,671 $388 $232 $3,291 $1,383 $0 $4,675 Requirements 405.3 Performance -based compliance passes by 6.5% ® R402.4.1.2 Air Leakage Testing 402.5 Area -weighted average fenestration SHGC 402.5 Area -weighted average fenestration LI-Factor ® 4032.2 Duct Testing Mandatory Checklist Mandatory code requirements that are not checked by Ekotrope must be met. R4052 Duct Insulation C",Erergy Solutions As Designed $2,549 $296 $232 $3,077 $1,365 $0 $4,442 Air sealing is 5.00 ACH at 50 Pa. It must not exceed 7.00 ACH at 50 Pa. Design exceeds requirements for IECC 2009 Performance compliance by 6.5%. As a 3rd party extension of the code jurisdiction utilizing these reports, I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zane 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party. Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 9117119 at 8:22 AM Ekotrope RATER - Version 3.1.1.2253 IECC 2009 Performance compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. 1180 WESTVALE DR CARMEL, IN 46032 Builder: EXECUTIVE HOMES CONSTRUCTION, INC. Ceiling Attic, R-38 Above Grade Walls R-15 Foundation Walls R-10 Framed Floor R-38 Slab R-0.0 Perimeter, R-0.0 Under Infiltration 5 ACH50 Window U-Value: 0.29, SHGC: 0.23 Building Features Duct Supply R-6.0, Return R-6.0 Duct Leakage to Outside 184 CFM25 (3.99 / 100 s.f.) Total Duct Leakage 368 CFM25 (Post -Construction) Heating Furnace • Natural Gas • 92.1 AFUE Cooling Air Conditioner • Electric • 13 SEER Water Heating Water Heater • Natural Gas • 0.96 Energy Factor As a 3rd party extension of the code jurisdiction utilizing these reports; I certify that this energy code compliance document has been created in accordance with the requirements of Chapter 4 of the adopted International Energy Conservation Code based on Climate Zone 5. If rating is Projected, I certify that the building design described herein is consistent with the building plans, specifications, and other calculations submitted with the permit application. If rating is Confirmed, I certify that the address referenced above has been inspected/tested and that the mandatory provisions of the IECC have been installed to meet or exceed the intent of the IECC or will be verified as such by another party_ Name: Devin Sielschott Organization: TSI Energy Solutions Signature: Date: 9/17/19 at 8:22 AM Ekotrope RATER - Version 3.1.1.2253 2009 IECC compliance results calculated using Ekotrope RATER's energy and code compliance algorithm. Ekotrope RATER is a RESNET Accredited HERS Rating Tool. All results are based on data entered by Ekotrope users. Ekotrope disclaims all liability for the information shown on this report. Energy Code Inspection Checklist Property Organization 1180 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSDNS GRANT 29 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKSDNS GRANT 298 General Building Information Conditioned Area (sq ft) 7,678 Conditioned Volume (cubic ft) 78,935 Insulated Shell Area (sq ft) 13,411 Inspection Status Results are projected C", Energy Solutions The building energy model in Ekotrope reflects the building assemblies and energy features listed below. Sometimes energy features will change in the field from what has been modeled. The inspection process should identify any changes and ensure that the home continues to meet the applicable energy code. Slab ] Name: BSMT(2,714 s.f., 249 ft. exterior perimeter) R-0 perimeter insulation, R-0 under slab insulation. Framed Floor ] Name: GARAGE (74 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I ] Name: AMBIENT (72 s.f.) R-0 continuous insulation, R-38 cavity insulation Insulation Grade: I Foundation Wall ] Name: COND/AMB (Exterior Perimeter [ft]: 157, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 9) R: 9.696 Fully insulated (top to bottom) ] Name: CDNDIAMB UNFIN (Exterior Perimeter [ft]: 68, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 9) R: 0.00 Fully insulated (top to bottom) 1l Name: CGNDIGARAGE (Exterior Perimeter [ft]: 16, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 9) J--1 R:9.696 Fully insulated (top to bottom) Energy Code Inspection Checklist TSI Energy Solutions Property Organization Inspection Status 1180 WESTVALE DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSDNS GRANT 29 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKSDNS GRANT 298 ] Name: CON DIGARAGE UNFIN (Exterior Perimeter [ft]: 8, Height Above Grade [ft]: 1, Depth Below Grade [ft]: 9) R: 0.00 Fully insulated (top to bottom) Above Grade Wall 1� Name: CON DIAMB (2,753 s.f.) 1--1 R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I 1� Name: CGNDIAMB 2X6 (969 s.f.) 1--1 R-0 continuous insulation, R-19 cavity insulation Insulation Grade: I 1� Name: CGNDIGAR (240 s.f.) 1--1 R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I ] Name: CON DIATTIC (778 s.f.) R-0 continuous insulation, R-15 cavity insulation Insulation Grade: I Rim Joist ] Name: CON DIAM B (326 s.f.) R: 15.414 ]l Name: CONDIGARAGE (24 s.f.) R: 15.414 ] Name: CON DIATTIC (111 s.f.) R: 15.414 Roof El Name: MAIN (2,860 s.f.) R-27.55 continuous insulation, R-10.15 cavity insulation Insulation Grade: I 2 Energy Code Inspection Checklist P ro pe rty 1180 WESTVALE ❑R CARMEL, IN 46032 Model: CUSTOM Community: JACKSONS GRANT 29. JG298 (AS DESIGNED) JACKSONS GRANT 298 Opaque Door Name: FRONT (48 s.f.) U: 0.476 Name: FRONT (24 s.f.) U: 0.476 El Name: GARAGE (24 s.f.) U: 0.182 Glazing Organization TSI Energy Solutions Devin Sielschott Builder EXECUTIVE HOMES CONSTRUCTION, INC. Inspection Status Results are projected Name: FRONT (213 s.f.), U: 0.290, SHGC: 0.23, Orientation: SOUTH 1� Name: FRONT 2X6 (88 s.f.), U: 0.290, SHGC: 0.23, Orientation: SOUTH El Name: BACK (274 s.f.), U: 0.290, SHGC: 0.23, Orientation: NORTH 1] Name: GO (24 s.f.), U: 0.290, SHGC: 0.23, Orientation: NORTH El Name: SLIDER (96 s.f.), U: 0.290, SHGC: 0.23, Orientation: NORTH El Name: LEFT (25 s.f.), U: 0.290, SHGC: 0.23, Orientation: WEST L] Name: LEFT 2X6 (88 s.f.), U: 0.290, SHGC: 0.23, Orientation: WEST L] Name: RIGHT (72 s.f.), U: 0.290, SHGC: 0.23, Orientation: EAST Name: BACK BSMT (15 s.f.), U: 0.290, SHGC: 0.23, Orientation: NORTH E] Name: LEFT BSMT (30 s.f.), U: 0.290, SHGC: 0.23, Orientation: WEST Skylight None Present CTMEnergy Solutions 3 Energy Code Inspection Checklist Property Organization 1180 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 29 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 298 Mechanical Ventilation Inspection Status Results are projected Mechanical ventilation system rated for, and capable of, providing continuous ventilation. System shall include automatic timing controls. System type: ERV, 8 hrslday, 100 Watts. Mechanical Equipment FURNACE 1 • Natural Gas • 60% Heating Load @ 92.1 AFUE FURNACE 2 • Natural Gas • 40% Heating Load @ 92.1 AFUE El AC 1 • Electric • 60% Cooling Load @ 13 SEER AC 2 • Electric • 40% Cooling Load @ 13 SEER 11 Water Heating • Natural Gas • 100% Hot Water Load @ 0.96 Energy Factor Air Leakage Control Test Status: Blower -door tested House is air -sealed as to achieve 6,578 CFM50 (5.00 ACH50) or less at final blower -door test. Infiltration Requirements for IECC in Climate Zone 5 2009 IECC Infiltration limit for the design home is 7 ACH50. 2012 IECC Infiltration limit for the design home is 3 ACH50. 2015 IECC Infiltration limit for the design home is 3 ACH50. C", Energy Solutions 4 Energy Code Inspection Checklist Property Organization 1180 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 29 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 298 Duct Leakage Duct System 1 Inspection Status Results are projected All ducts and equipment within conditioned space Leakage to Outside specified as: 184 CFM25 (3.99 / 100 s.f.) Total Leakage specified as: 368 CFM25 (Post -Construction) Duct System 2 NOT entirely within conditioned space, testing required Leakage to Outside specified as: 150 CFM25 (4.88 / 100 s.f.) Total Leakage specified as: 368 CFM25 (Post -Construction) Duct Leakage Code Requirements for IECC 2009 IECC: Postconstruction Leakage Test: Duct Leakage to Outdoors <= 8 CFM25 / 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 6 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. 2012 IECC and 2015 IECC Prescriptive Path: Postconstruction Leakage Test: Total Duct Leakage <= 4 CFM251 100 sq ft CFA. Rough in Test with AHU: Total Duct Leakage <= 4 CFM25 / 100 sq ft CFA. Rough in Test without AHU: Total Duct Leakage <= 3 CFM25 / 100 sq ft CFA. 2015 Performance Path (Cost Compliance): C", Energy Solutions Leakage testing is required UNLESS all ducts and air handlers are located entirely within the thermal envelope. There is no pass/fail threshold for duct leakage on the performance path. Project Notes 5 Building Summary Property Organization Inspection Status *Sl Energy Solutions 118o WESTVALE DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 298 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 298 General Building Information Number Of Bedrooms 5 Number Of Floors 2 Conditioned Floor Area [sq. ft.] 7,678 Unconditioned; attached garage? Yes Conditioned Volume [cu. ft.] 78,935 Total Units in Building 1 Residence Type Single family detached Floor Number Model CUSTOM Community JACKSONS GRANT 298 Climate Zone 5A Foundation Wall Name Library type Height Above Grade Depth Below Grade Perimeter Location Enclosing CONDIAMB R-11 Finished, G1 1 9 157 Exposed Exterior Conditioned Space CONDIAMB UNFIN Uninsulated 1 9 68 Exposed Exterior Conditioned Space CONDIGARAGE R-11 Finished, G1 1 9 16 Exposed Exterior Conditioned Space CONDIGARAGE Uninsulated 1 9 8 Exposed Exterior Conditioned Space UNFIN Foundation Wall Library List Name Feet From Wall Top To Feet From Wall Top To Is Fully Insulated Continuous R-value Cavity R-value Effective Insulation R- Continuous Insulation Continuous Insulation value Top Bottom R-11 Finished, G1 NIA NIA Yes N:.A N/A 9.696 Uninsulated NIA NIA Yes N:.A N/A 0.00 Slab Name Library Type Perimeter Floor Grade Carpet R Exposed Surface Area Location Enclosing Masonry Area BSMT Uninsulated 249 Below Grade 0 0 2,714.0 ft' Exposed Exterior Conditioned Space 1 Building Summary Property Organization Inspection Status 118❑ WESTVALE DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 298 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKS0NS GRANT 298 Slab Library List Name Wall Construction Slab Completel�r Underslab Perimeter Perimeter Type Insulated. Insulation Width [ft] Insulation Depth [ft] Insulation R Value Uninsulated Woad Frame 1 Other No ❑ 0 ❑ Framed Floor JL— M Name Library Type Carpet R Floor Grade ! AMBIENT R-38. GR1 1 Above Grade GARAGE R-38. GR1 1 Above Grade Framed Floor Library List C"IEnergy Solutions No ❑.00 ce Area t.ocatron 72.0 ft' Exposed Exterior 74.0 fI' Unconditioned. attached garage Name Effective R-value R-38, GR1 33.825 Rim Joist Name Library Type Surface Area Location CONDIAMB G1 R-19. OSB 326.0 fI1 Exposed Exterior CONDIATTIC G1 R-19. OSB 111.0 fI1 Attic CONDIGARAGE G1 R-19. OSB 24.0 fl' Unconditioned, attached garage Rim Joist Library List Name Effective Insulation R-value G1 R-19. OSB 15.414 Building Summary Property Organization 1180 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 298 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 298 Inspection Status Results are projected C"IEnergy Solutions Name Library Type CONDIAMB G1 R-15 BATT, OSB Surface Color Medium Surface Area 2,753.0 ft' Location Exposed Exterior CONDIAMB 2X6 G1 R-19, OSB 2x6 Medium 969.0 ft2 Exposed Exterior CONDIATTIC G1 R-15 BATT, OSB Medium 778.0 ft2 Attic CONDIGAR G1 R-15 Gar Walls Medium 240.0 ft' Unconditioned, attached garage Wall Library List Name Effective R-value G1 R-15 BATT. OSB 13.423 G1 R-15 Gar Walls 11.972 G1 R-19, OSB 2x6 17.591 Glazing Name Library Type Wall Assignment Foundation Wall Assignment BACK U-.29. SHGC-.23 CONDIAMB Overhang Depth Overhang 0 Ft Tb Tap 0 Overhan_g Ft To lJottom 0 Orientation North Surface Area 274.0 ft2 BACK BSMT U-.29. SHGC-23 CONDIAMB 0 0 0 North 15.0 ft2 FRONT U-.29. SHGC-23 CONDIAMB 0 0 0 South 213.0 ft2 FRONT 2X6 U-.29. SHGC-23 CONDIAMB 2X6 0 0 0 South 88.0 ft2 GD U-.29. SHGC-23 CONDIAMB 0 0 0 North 24.0 ft2 LEFT U-.29, SHGC-23 CONDIAMB 0 0 0 West 25.0 ft2 LEFT 2X6 U-.29, SHGC-23 CONDIAMB 0 0 0 West 88.0 ft, LEFT BSMT U-.29, SHGC-23 CONDIAMB 0 0 0 West 30.0 fie RIGHT U-.29. SHGC-23 CONDIAMB 0 0 0 East 72.0 ft2 SLIDER U-.29, SHGC-23 CONDIAMB 0 0 0 North 96.0 ft2 3 Building Summary Property Organization Inspection Status 118o WESTVALE DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 298 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 298 Glazing Library List i Name Shgc U-factor U-29, SHGC-.23 0.23 0.290 Skylight Skylight Library List None Present None Present Opaque Door Name Library Type Wall Assignment Foundation Wall Assignment FRONT Wood Door CONDiAMB FRONT Wood Door CONDIAMB GARAGE FiberglasslSteel CONDIGAR Door Opaque Door Library List Name FiberglasslSteel Door Wood Door U-factor 0.182 0.476 C"IEnergy Solutions Emittance Solar Surface Color Surface Area Location Absorptance 0.9 0.75 Medium 48.0 fll Exposed Exterior 0.9 0.75 Medium 24.0 ft2 Exposed Exterior 0.9 0.75 Medium 24.0 fI1 Exposed Exterior 4 Building Summary Property 1180 WESTVALE DR CARMEL, IN 46032 Model: CUSTOM Community: JACKSONS GRANT 298 JG298(AS DESIGNED) JACKS0NS GRANT 298 Roof Insulation am Name Library type MAIN R-38 Blown, GRt Roof Insulation Library List Name Has R-38 Blown, GRt Whole House Infiltration InfiRration Me; 5ACH at 50 Pa Blower -door tested Organization TSI Energy Solutions Devin Sielschott Builder EXECUTIVE HOMES CONSTRUCTION, INC. No 2,860 Inspection Status Results are projected or concrete Roof surface Colol Tiles No Medium Mechanical Ventilation IF Ventilation Type Ventilation Rate [ft' 1 Operational hours perday Minute] E RV 200 8 Lightir °4 Interior F 0 Gnsite Generation 80 0 38.268 4 C"IEnergy Solutions 2.860.0 fI' Attic Fan Watts Runs once every three Energy Recovery Percent hours 100 Yes E6 80 cent % Garage LED Lighting sting C 8C 5 Building Summary Property Organization 1180 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 298 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 298 Onsite Generation Library List IM None Present Solar Generation Solar Generation Library List None Present Inspection Status Results are projected C"IEnergy Solutions Conditioning Equipment Name Library type Heating Percent Load Cooling Percent Load Hot Water Percent Load Location Ac " CA13NA042-A 0% 60% 0% Conditioned Space AC 2 CA13NA042-A 0% 40% 0% Conditioned Space FURNACE 1 912SA48100S17 60% 0% 0% Conditioned Space FURNACE 2 912SA48104S17 40% 0% 0% Conditioned Space Water Heating NPE-240A 0% 0% 100% Conditioned Space ment Type: 912SA4810OS1Le Natural Gas onType Forced Air pe PSG (Single Speed) fficiency 92.1 AFUE F apacity [kBtulh] 93ult EAE N❑ h] 756 6 Building Summary Property Organization Inspection Status 118o WESTVALE DR TSI Energy Solutions Results are projected CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 298 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKSONS GRANT 298 uipment Type: CA13NA042-A Fuel Type Electric Distribution Type Forced Air Motor Type PSG (Single Speed) Cooling Efficiency 13 SEER Cooling Capacity [kBtulh] 40 Equipment Type: NPE-240A Fuel Type Natural Gas Distribution Type Hydronic Delivery Hot Water Efficiency 0.96 Energy Factor Tankless? Yes Hot Water Capacity [kBtulh] 1999. Recovery Efficiency 0.99 C"IEnergy Solutions Building Summary Property Organization 1180 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 298 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKS0NS GRANT 298 Distribution System Distribution Type Forced Air Heating Equipment FURNACE 1 Cooling Equipment AC 1 Sq. Feet Served 4606 # Return Grilles 4 Supply Duct R Value 6 Return Dud R Value 6 Supply Duct Area [ftl 1243.62 Return Dud Area [ftq 921.2 Leakage to Outdoors 184 CFM25 (3.99 1100 s.f.) Total Leakage 368 CFM25 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 100 Percent Return Area 100 Duct 2 Duct Location Attic (well vented, under insulation) Percent Supply Area ❑ Percent Return Area ❑ Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Inspection Status Results are projected C"IEnergy Solutions Building Summary Property Organization 1180 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 298 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKS0NS GRANT 298 Distribution System Distribution Type Forced Air Heating Equipment FURNACE 2 Cooling Equipment AC 2 Sq. Feet Served 3072 # Return Grilles 4 Supply Duct R Value 20 Return Dud R Value 20 Supply Duct Area [ftl 829.44 Return Dud Area [ftq 614.4 Leakage to Outdoors 150 CFM25 (4.88 1100 s.f.) Total Leakage 240 CFM25 Total Leakage Duct Test Conditions Post -Construction Use Default Flow Rate Yes Duct 1 Duct Location Conditioned Space Percent Supply Area 10 Percent Return Area 10 Duct 2 Duct Location Attic (well vented, under insulation) Percent Supply Area 90 Percent Return Area 90 Duct 3 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 4 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Duct 5 Duct Location Conditioned Space Percent Supply Area 0 Percent Return Area ❑ Duct 6 Duct Location Conditioned Space Percent Supply Area ❑ Percent Return Area 0 Ceiling Fan Has Ceiling Fan Cfm Per Watt No 100 Inspection Status Results are projected C"IEnergy Solutions Building Summary Property Organization 1180 WESTVALE DR TSI Energy Solutions CARMEL, IN 46032 Devin Sielschott Model: CUSTOM Community: JACKSONS GRANT 298 Builder EXECUTIVE HOMES JG298 (AS DESIGNED) CONSTRUCTION, INC. JACKS0NS GRANT 298 Water Distribution Water Fixture Type Standard Use Default Hot Water Pipe Length No Hot Water Pipe Length [ft] 75 At Least R3 Pipe Insulation? No Hot Water Recirculation System? No Recirculation System Pipe Loop Length [ft] 20 Drain Water Heat Recovery? No Clothes Dryer Fuel Type Electric Cef 2.617 Field Utilization Timer Controls INA Label Energy Rating 704 kWh1Year Electric Rate $0.081kWh Annual Gas Cost $23.00 Gas Rate $0.581Therm Capacity 2.874 Imet ❑.331 ppliances and Controls rogrammable thermostat? Yes ishwasher Size Standard ishwasher Efficiency ID 270 kWhangefOven Fuel Electric onvection Oven? N❑ duction Range? N❑ efrigerator Consumption 709 kVVhfYear Inspection Status Results are projected C"IEnergy Solutions 10