HomeMy WebLinkAboutA-3.03RELEA Susie POWER, VOICE AND DATA SYMBOLS POWER, VOICE AND DATA NOTES ® AREA NOT IN CONTRACT I. UNLESS OTHERWISE NOTED, ALL CONVENIENCE OUTLETS TO BE WHITE IN COLOR. 2 NOTED, ALL DEDICATED OUTLETS TO BE GRAY IN COLOR, AND ppppM -ROOM NAME BELLA EOTDHERWISE ROOM - ROOM NAME 301 - ROOM NUMBER 3. UNLESS OTHERWISE NOTED, ALL COVER PLATES TO BE WHITE IN COLOR. ALL EQUIPMENT DESIGNATED BY THIS EQUIPMENT SYMBOL TO RECEIVE ALL V-6' VERTICALLY ® POWER AND RECEPTACLE TYPE AS REQUIRED. REFER TO EQUIPMENT 4. CENTER OF OUTLETS AND CONNECTORS TO BE A.F.F. AND SCHEDULE FOR MORE INFORMATION MOUNTED, UNLESS OTHERWISE NOTED. STANDARD DUPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT 18' 5. ALL DIMENSIONS SHOWN ARE TO THE CENTER OF THE RECEPTACLE, UNLESS A.F.F. UNLESS NOTED OTHERWISE. OTHERWISE NOTED. DEVICES SHOWN CLUSTERED TOGETHER ON THE POWER, DATA AND VOICE PLANS) SHALL BE MOUNTED AS CLOSELY TOGETHER AS POSSIBLE. Y DEDICATED DUPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT 18' A.F.F. UNLESS NOTED OTHERWISE. 6. ALL OUTLETS SHOWN WITH THE SIDE MARK 'GFI' ARE TO BE ON A GROUND FAULT INTERRUPTION CIRCUIT. «20A 20 AMP DEDICATED DUPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT 18' A.F.F. UNLESS NOTED OTHERWISE. 7. REFER TO THE DEMOLITION PLAN FOR ADDITIONAL INFORMATION RELATED TO POWER AND CABLING DEMOLITION. �GFI STANDARD GROUND FAULT INTERRUPTER DUPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT 42' A.F.F. UNLESS NOTED OTHERWISE. S. ALL EXISTING AND NEW FLOOR SLAB PENETRATIONS FOR CONDUIT SHALL BE FULLY PACKED AND SEALED IN ACCORDANCE WITH APPLICABLE BUILDING AND FIRE CODES. PRIOR TO ANY FLOOR TRENCHING OR CORING, THE FLOOR MUST BE X-RAYED FIRST. STANDARD QUADRAPLEX ELECTRICAL OUTLET VERTICALLY ORIENTED AT 18' A.F.F. UNLESS NOTED OTHERWISE. S. G.C.'S ELECTRICIAN IS RESPONSIBLE FOR THE HARDWIRED CONNECTION OF FURNITURE BASE FEEDS OF TENANT'S SYSTEMS FURNITURE. SYSTEMS FURNITURE ELECTRICAL (3) STUBBED CONDUIT FOR POWER, DATA AND AV. FIRE SAFE AS REQUIRED COMPONENTS TO BE CONNECTED TOGETHER BY THE TENANT'S FURNITURE �-I `=3D IN ACCORDANCE WITH THESE DRAWINGS. COORDINATE LOCATION WITH INSTALLER, AND VOICE/ DATA CABLING BY TENANT'S VOICE/ DATA CABLING VENDOR.. FCI ARCHITECT AND FURNITURE VENDOR PRIOR TO CORING FOR COORDINATION WITH THE TABLE LEG. SEE ENGINEER FOR FURTHER INFORMATION. 10. REFER TO DETAIL 3/A-3.03 FOR WIRING DIAGRAMS FOR THE HERMAN MILLER WORKSTATIONS. ALL RECEPTACLES INSTALLED IN MODULAR FURNITURE SHALL BE PER POWER: ONE 1/2' EC STUB. ONE SHIELDED ELECTRICAL CABLE. SYSTEMS FURNITURE WIRING DIAGRAMS. DATA: ONE 3/4' EC STUB FOR THREE Case NETWORK CABLES TO THE MDF. 11. ALL VOICE AND DATA CABLING TO BE BY THE TENANT'S CABLING VENDOR. G.C. TO AV: ONE 1-1/4' EC STUB FOR ONE HDMI AND TWO AUDIO TO THE COORDINATE CABLING VENDOR'S SCOPE OF WORK WITH HIS OWN. G.C. TO PROVIDE MONITOR ('AV-) CABLING VENDOR, IN ADVANCE, WITH SCHEDULE SHOWING TIME FRAME FOR CABLING VENDOR TO RUN CABLES WHEN WALLS AND CEILING ARE OPEN SO THAT CABLING AND INSTALLATION CAN BE ACCOMPLISHED WITHOUT HAVING TO DEMOLISH OR UNDO FLUSH, RECESSED FLOOR OUTLET POKE THRU: ANY WORK ALREADY COMPLETED. ® WIREMOLD EVOLUTION 6ATCBK RECESSED POKE THRU ASSEMBLY OR 4D APPROVED EQUAL, W/ (1) 20 AMP DUPLEX RECEPTACLE AND (4) DATA JACKS. 12. O.C. TO PROVIDE SAFETY GROMMETS, BACK BOXES, CONDUIT WITHIN THE WALLS AND FBI G.C. TO PROVIDE ALL DEVICE PLATES AND CONDUIT AS REQUIRED FOR PULL LINES FOR VOICE/DATA RECEPTACLES WHERE SHOWN ON O.W.B. PARTITIONS. POWER AND DATA WHICH WILL TERMINATE ABOVE THE CEILING AT THE ALL CABLING TO BE DONE BY THE TENANT'S CABLE VENDOR. PROVIDE J' CONDUIT NEAREST PARTITION BY G.C.'S ELECTRICAL CONTRACTOR. ALL DATA CABLING STUB UP AND TERMINATE 6' ABOVE CEILING, U.N.O., TO BE SUPPLIED BY TENANT'S SEPARATELY CONTRACTED CABLING VENDOR. 13. ALL POWER, VOICE, DATA AND AV CABLING RUN IN OTHER TENANTS PLENUM SPACE INDICATES WALL MOUNTED ELECTRICAL RACEWAY MOUNTED AT 18' A.F.F. OR CROSSING A COMMON CORRIDOR MUST BE RUN IN CONDUIT. COORDINATE REQUIRED UNLESS NOTED OTHERWISE. CONDUIT SIZES WITH THE TENANTS CABLING AND AV VENDORS. REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. VOICE/DATA RECEPTACLE (I VOICE PORT / I DATA PORT) AT IB' A.F.F. UNLESS NOTED OTHERWISE - BACK BOX, SAFETY GROMMET AND PULL 14. REFER TO DOOR AND HARDWARE SCHEDULES ON SHEET A-5.00 FOR DOORS WITH IT/ID STRING BY G.C.'S ELECTRICAL CONTRACTOR, CABLING AND TERMINATION CARD READERS, ELECTRICAL LOCK SETS, ETC. DEVICE BY OTHERS. 15. AT RECEPTION DOORS 301A AND 3018 THE SECURITY VENDOR IS TO PROVIDE AND CABLING CONNECTOR (1, 2, 3 OR 4 DATA PORT(S)) AT 18' A.F.F. UNLESS INSTALL WALL MOUNTED SWITCH THAT WILL OPERATE THE DURESS INDICATOR LIGHTS IN OPEN OFFICE f322 1329, 1333 AND /335. THE SWITCHES AND LIGHTS N NOTED OTHERWISE - BACK BOX, SAFETY GROMMET, PULL STRING, AND SHALL BE PROVIDED AND INSTALLED BY THE SECURITY VENDOR. G.C. TO PROVIDE ID/2D/3D/4D WHEN REQUIRED, CONDUITS, BY G.C.'S ELECTRICAL CONTRACTOR. CABLING J-BOXES AND PULL STRINGS AS REQUIRED. COORDINATE INSTALLATION WITH THE AND TERMINATION DEVICE BY TENANT'S DATA CABLING VENDOR. SECURITY VENDOR. WALL INFEED OF POWER ONLY INTO THE BASE OF THE SYSTEMS 16. G.C. IS TO PROVIDE DOOR BELL AT DOOR 1301B, WHICH IS TO SOUND AT Ed FURNITURE ELECTRIFIED BASE. INFEED TO BE MOUNTED IN WALL AT f-0' WORKSTATION IN OPEN AREA 1325. A.F.F. TO CENTERLINE OF INFEED BOX. ELECTRICIAN TO HARDWIRE 'POWER WHIP'. 17 D.C. IS TO SUPPLY AND CONNECT WATER LINES TO INTEGRAL ICE MAKERS AND IN -DOOR WATER WITHIN REFRIGERATORS, AND COFFEE MAKERS. SEE POWER, VOICE k WALL INFEED OF VOICE k DATA CABLING INTO THE BASE OF THE SYSTEMS DATA PLAN FOR LOCATIONS OF EQUIPMENT. FURNITURE. INFEED TO BE MOUNTED IN WALL AT I'-0' A.F.F. TO 18. G.C. TO PROVIDE AND INSTALL HARDWIRED TIMING CONTROL DEVICES WITH 'NO -HOLD' W CENTERLINE OF INFEED BOX. G.C. TO ALSO PROVIDE, A COVER PLATE WITH (2) 1-1/2' DIAMETER GROMMETS. ALL VOICE AND DATA CABLING TO POSITIONS ONTO ALL OUTLETS TO SERVICE COFFEE MAKERS. TIMING DEVICES MUST PROVIDE HOURS OF POWER, NOT MINUTES. BE SUPPLIED BY TENANT'S SEPARATELY CONTRACTED CABLING VENDOR, WHO WILL NEATLY BUNDLE/WRAP THE CABLES GOING THROUGH THE 19. IN IDF /303, FOR THE SECURITY SYSTEM ACCESS CONTROL PANEL: O.C. TO PROVIDE GROMMETS TO THE BASE OF THE SYSTEMS FURNITURE. (1) DEDICATED 110VAC 20 AMP CIRCUIT. THE TELE/DATA VENDOR IS TO PROVIDE (1) VOICE DROP AND (1) DATA DROP. LOCATION OF POWER VOICE AND DATA TO BE ELECTRICAL FLOOR INFEED OF POWER AND VOICE/DATA INTO THE BASE OF CONFIRMED WITH THE SECURITY VENDOR PRIOR TO INSTALLATION. THE SYSTEMS FURNITURE ELECTRIFIED BASE. POKE THRU TO BE WIREMOLD EVOLUTION MULTI -SERVICE POKE THRU DEVICE, 6ATCFF OR APPROVED 20. IN IDF 1303, FOR THE SECURITY ALARM PANEL: O.C. TO PROVIDE (1) DEDICATED 110VAC EE EQUAL. CONDUIT AS REQUIRED FOR POWER AND DATA IN PLENUM SPACE 20 AMP CIRCUIT AND THE TELE/DATA VENDOR IS TO PROVIDE (1) DEDICATED PHONE BELOW BY G.C.'S ELECTRICAL CONTRACTOR, CONFIRM CONDUIT SIZES WITH CABLING VENDOR. DIMENSIONS SHOWN ARE TO THE CENTERLINE OF INFEED LINE. BOX. INFEED TO BE FLUSH MOUNTED IN SLAB. ELECTRICIAN TO HARDWIRE POWER WHIP'. ELECTRICAL CONTRACTOR TO MAKE CONNECTION- SEE 21 IN IDF 1303, G.C. TO PROVIDE AT A MINIMUM, (1) 4" CONDUIT RUN FROM THE BUILDING POWER, VOICE It DATA NOTE 09. ALL VOICE AND DATA CABLING TO BE DEMARCATION POINT TO THE TELECOM ROOM FOR LIBERTY MUTUAL'S TI LINE. ALL SUPPLIED BY TENANT'S SEPARATELY CONTRACTED CABLING VENDOR, WHO HOUSE PAIRS, FIBER OPTIC CABLE, AND ANY OTHER CABLE RUNNING FROM THE WILL NEATLY BUNDLE/WRAP THE CABLES TO THE BASE OF THE SYSTEMS BUILDING DEMARCATION POINT TO THE TELECOM ROOM SHALL BE IN CONDUIT. FURNITURE. SEE ENGINEER'S DRAWINGS FOR FURTHER INFORMATION. CR CARD ACCESS PROXIMITY READER FOR TENANT'S SECURITY SYSTEM BY SECURITY VENDOR. BACK BOX, SAFETY GROMMET AND PULL STRING BY G.C.'S ELECTRICAL CONTRACTOR. MD MOTION DETECTOR DEVICE FOR TENANT'S SECURITY SYSTEM BY SECURITY VENDOR. USED TO SHUNT THE DOOR CONTACT IN ORDER FOR THE ACCESS CONTROL SYSTEM TO RECOGNIZE THE DOOR IS OPENING BY SOMEONE EXITING AND NOT FORCED OPEN FROM THE OUTSIDE. MOTION DETECTOR DEVICE IS NOT TIED INTO THE DOOR HARDWARE. DB DOOR BELL. SEE NOTE 116. SINGLE GANG MUD RING WITH TWO PULL STRINGS AT 18' AFF WITH 1-1/4' AV1 CONDUIT TO THE FLOOR STUB BY G.C.'S ELECTRICAL CONTRACTOR. AV TERMINATIONS BY THE TENANT'S AV VENDOR. AV VENDOR TO PROVIDE REQUIRED FACEPLATES. CHIEF MFG. PAC526 WITH TWO PULL STRINGS WITH 1-1/4' CONDUIT TO AV2 THE PLENUM. BOX BY G.C.'S ELECTRICAL CONTRACTOR. AV TERMINATIONS BY THE TENANT'S AV VENDOR. AV VENDOR TO PROVIDE REQUIRED FACEPLATES. MOUNTING HEIGHT AS INDICATED ON PLANS. SINGLE GANG ELECTRICAL BOX AT 4'-0' A.F.F. HORIZONTALLY MOUNTED FOR J1 4 TENANT'S CRESTRON TPMC-4SM ROOM VIEW UNIT. TELEDATA CABLER TO PROVIDE (I) MALE RJ45 CONNECTION FROM TELECOM ROOM TO JUNCTION BOX. DURESS INDICATOR LIGHT PROVIDED BY TENANT'S SEPARATELY CONTRACTED SECURITY VENDOR. (42) INDICATES DEVICE MOUNTED VERTICALLY AT 424 A.F.F. TO THE CENTER OF THE DEVICE. (VARIES) EX DENOTES ITEM IS EXISTING TO REMAIN ALTERNATES O PROVIDE ADD/ALTERNATE PRICING TO PROVIDE AND INSTALL DATA CABLING PER LIBERTY MUTUAL INFORMATION TRANSPORT SYSTEMS STANDARDS" DOCUMENT. PER STANDARD DOCUMENT AND ELECTRICAL PLANS, PROVIDE AND INSTALL THE SPECIFIED 4-POST EQUIPMENT RACK IN TELECOM ROOM. PLEASE CHECK ELECTRICAL PLANS TO DETERMINE IF THIS PROJECT IS VOIP. ® PROVIDE ADD/ALTERNATE PRICING TO SUPPLY AND INSTALL THE FOLLOWING APPLIANCES: (2) REFRIGERATOR(S), (2) MICROWAVE(S), (1) UNDER -COUNTER REFRIGERATOR AND (1) ICE MAKER. REFER TO THE APPLIANCE SCHEDULE FOR SPECIFICATIONS. GENERAL CONTRACTOR PROVIDED EQUIPMENT SHALL BE INVOICED TO LIBERTY MUTUAL SEPARATE FROM THE GENERAL CONTRACT. PMENTSCHED Code Item Manufacturer Model No. Comments El PERSONAL COMPUTER - - PROVIDED AND INSTALLED BY LIBERTY MUTUAL E2 WALL MOUNTED MONITOR - - PROVIDED AND INSTALLED BY LIBERTY MUTUAL E3 MULTI FUNCTION DEVICE _ PROVIDED AND INSTALLED BY LIBERTY MUTUAL APPLIANCE SCHEDULE Code Item Manufacturer Model No. Comments PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE 14. G.C. T-23-HC STAINLESS TO PROVIDE WATERTITE MODEL 9000 PVC ICE MAKER OUTLET BOX W/ AP1 REFRIGERATOR TRUE STEEL, 3.3 CU. CUT-OFF VALVE MOUNTED AT 180 A.F.F. WITH WATTS BRAIDED STAINLESS FT. STEEL CONNECTOR AND INTEGRAL SHUT OFF VALVE ON INLET SIDE. REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. AP2 AVENUE C (VENDING) - - PROVIDED AND INSTALLED BY LIBERTY MUTUAL PROVIDED AND INSTALLED BY LIBERTY MUTUAL. O.C. TO PROVIDE WATERTITE MODEL 9000 PVC ICE MAKER OUTLET BOX W/ CUT-OFF AP3 COFFEE MAKER - - VALVE MOUNTED ABOVE THE COUNTERTOP WITH WATTS BRAIDED STAINLESS STEEL CONNECTOR AND INTEGRAL SHUT OFF VALVE ON INLET SIDE. REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. IOOOW/R - 21LT AP4 MICROWAVE SHARP STAINLESS PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE /4. STEEL AP5 UNDER -COUNTER U-LINE 29RB, BLACK PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE f4 REFRIGERATOR HID525 OR PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE j4. O.C. HID540 W/ TO PROVIDE WATERTITE MODEL 9000 PVC ICE MAKER OUTLET BOX W/ AP6 ICE MACHINE SCOTSMAN OVERFLOW CUT-OFF VALVE MOUNTED AT IB' A.F.F. WITH WATTS BRAIDED STAINLESS PROTECTION STEEL CONNECTOR AND INTEGRAL SHUT OFF VALVE ON INLET SIDE. PAN REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. HST21-A AP7 ICE MACHINE STAND SCOTSMAN STAINLESS PROVIDED AND INSTALLED BY LIBERTY MUTUAL. SEE ALTERNATE f4. STEEL 3ED FOR CONSTRUCTION 1 to compliance with all regulations of State and Local Codes City of Conrad s n L" PON, I Bull COLLAB 5-M POWER, VOICE AND DATA PLAIN THREE (3) 4 POST DATA RACK AND WIRE MANAGERS: FLOOR MOUNTED AND POWERED THROUGHOUT DED. QUAD 20 AMP. 5-15R DED. L14-30R 2 POLE 60A INPUT BREAKER HARDWIRE TERMINAL BLOCK DED.QUAD 20 AMP. 5-15R I F; ENLARGED PLAN - TELECOM ROOM #303 L FIVE (5) DED. L6-20R OUTLETS PBX STATION WALL FEED _ VOICE STATION WALL FEED f6-AWG GROUND BAR. D On COLLAR 33B e SECURITY, ALARM AND ACCESS CONTROL PANELS (STACKED) TO BE HARDWIRED. SEE NOTE f19 k 120 /CC 3 C I��; - Ills I1111111��Q ��; 1 1 NOTE: DO NOT INSTALL RECEPTACLES, VOICE OR DATA DEVICES ON END PANELS UNLESS INDICATED ON ARCHITECTS I/e' SCALE PLANS. IF DEVICES ARE INDICATED ON 1/8- SCALE PLAN - CIRCUIT WILL BE DESIGNATED. wih III I��Ny I�II�I I I I�II�I M t 314BA ❑❑❑❑ \Y C/ V%-GCl HIVE 314A SEE NOTE #18. EE SYMBOLS C ROOM 313 N (B SCALE: j I /8" = F-W PQ� DUPLEX RECEPTACLE MOUNTED IN MODULAR FURNITURE BY FURNITURE INSTALLER. (RECEPTACLE DESIGNATION INDICATED BY LETTER INDICATES PHASE 'A', 'B' OR 'C'). (Computer) ADJACENT TO RECEPTACLE INDICATES DEVICE FOR COMPUTER TO BE CONNECTED TO. p COMBINATION VOICE/DATA OUTLET MOUNTED IN MODULAR FURNITURE. ONE VOICE AND ONE DATA UNLESS OTHERWISE NOTED. b VOICE OUTLET MOUNTED IN MODULAR FURNITURE. ONE VOICE UNLESS OTHERWISE NOTED. N DATA OUTLET MOUNTED IN MODULAR FURNITURE. ONE DATA UNLESS OTHERWISE NOTED. INDICATES THE EXTENT OF THE SYSTEMS FURNITURE ELECTRIFIED BASE FURNITURE SYSTEM WIRING WIRING PROVIDED IN FURNITURE AND IT'S USE. NI NEUTRAL SHARED WITH HI, H2 k H3 (110 AWG) N2 NEUTRAL SHARED WITH H4 (110 AWG) GI GROUND SHARED WITH HI, H2 k H3 (J12 AWG) 02 SHAREDGROUND WITH H4 ( (OR ISOLATED IF INDICATED ON DRAWINGS) H1 HOT - TO BE USED FOR PHASE A (j12 AWG) H2 HOT - TO BE USED FOR PHASE B #12 AWO H3 HOT - TO BE USED FOR PHASE C j12 AWG H4 HOT - TO BE USED FOR 'D' CIRCUIT (f12 AWG) 1 I. ROTATION OF CIRCUITS SHALL REMAIN THE SAME FOR ODD NUMBERED WORKGROUPS. SIMPLY DELETE THE WORKSTATION NOT SHOWN. 2. *HERMAN MILLER' MODULAR FURNITURE IS PROVIDED WITH AN 8 WIRE WHIP BY FURNITURE MANUFACTURER AND CONNECTED TO FURNITURE BY FURNITURE INSTALLER, 3. ELECTRICAL CONTRACTOR SHALL CONNECT WHIP FROM MODULAR FURNITURE TO FLOOR POKE-THRU OR JUNCTION BOX OR WALL JUNCTION BOX AS INDICATED ON THE ELECTRICAL DRAWINGS. ELECTRICAL CONTRACTOR SHALL CAP 'H4', 'N2' It 'G2' IN JUNCTION BOX FOR POSSIBLE FUTURE USE WHERE ONLY THREE HOMERUNS ARE INDICATED TO MODULAR FURNITURE. 4. WHERE A FOUR CIRCUIT HOMERUN IS INDICATED ON THE DRAWINGS ELECTRICAL CONTRACTOR SHALL CONNECT OGI' k '02' GROUNDS TOGETHER AT FEED LOCATION UNLESS ADDITIONAL GROUNDING CONDUCTOR IS INDICATED ON HOMERUN. 5. ELECTRICAL FEED TO MODULAR FURNITURE SHALL BE LOCATED PER ARCHITECTURAL DRAWINGS. 6. ALL VOICE AND DATA DEVICES AND WIRING ARE TO BE INSTALLED BY THE VOICE/DATA VENDOR. ELECTRICAL CONTRACTOR SHALL PROVIDE FLOOR JUNCTION BOX OR POKE-THRU OR WALL JUNCTION AS INDICATED ON THE DRAWINGS AND FLEXIBLE WATERTIGHT CONDUIT TO MODULAR FURNITURE FOR USE BY THE VOICE/DATA VENDOR. ALL JUNCTION BOXES AND CONDUIT SHALL BE SIZED PER THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE. SCALE. SCALE: 1/4..=I._o.. HERMAN MILLER MODULAR FURNITURE WIRING DIAGRAM N.T.S H E L L Y E R LEWIS- ARCHITECTURE INTERIOR DESIGN Project: Liberty Mutual, INSURANCE 450 East 96th St 3rd Floor Indianapolis IN 46240 Scale: 1 /8" = 1'-0" Drawing: Power, Voice and Data Plan No. A-3mO3 �G� DATE: 10/23/19