HomeMy WebLinkAboutA-5.00HARDWARE SCHEDULE
DOOR SCHEDULE
SET
/1 - CLOSET
PASSAGE LATCHSET (SINGLE DOOR)
SET #6 - ELECTRIC
STRIKE WITH CLOSER
2 PAIR HINGES
4 1/20 ANTI —FRICTION BEARING HINGES
BY GENERAL CONTRACTOR:
FINISH: MATCH EXISTING
2 PAIR HINGES
4 1/2° ANTI —FRICTION BEARING HINGES
I LATCHSET
BLDG. STD. PASSAGE LEVER LATCHSET
FINISH: MATCH EXISTING
FINISH: MATCH EXISTING
I CLOSER
"ADA COMPLIANT LCN CLOSERS" OR EQUAL: 4040XP
SERIES (PULL SIDE MOUNTED) WITH 72MC METAL
I OVERHEAD STOP
"RIXSOW 010 SERIES OVERHEAD STOP
COVER
FINISH: MATCH EXISTING
FINISH: MATCH EXISTING
4 RUBBER SILENCERS
I ELEC. STRIKE
HES, SERIES 1006CS , .25 AMPS ® 24VDC WITH HES
SMART PAC III ON FAIL SAFE HARDWARE
FINISH: MATCH EXISTING
SET /2 - PASSAGE LATCHSET
2 PAIR HINGES 4 1/2" ANTI —FRICTION BEARING HINGES
FINISH: MATCH EXISTING
I LATCHSET BLDG. STD. LEVER PASSAGE LATCHSET
FINISH: MATCH EXISTING
4 RUBBER SILENCERS
SET /3 - CLASSROOM LOCKSET (SINGLE)
2 PAIR HINGES 4 1/2' ANTI —FRICTION BEARING HINGES
FINISH: MATCH EXISTING
I LOCKSET BLDG. STD. LEVER CLASSROOM LOCKSET
FINISH: MATCH EXISTING
I FLOOR STOP 'RIXSON" §10 SERIES FLOOR STOP
FINISH: MATCH EXISTING
4 RUBBER SILENCERS
SET 04 - STOREROOM LOCKSET WITH CLOSER
2 PAIR HINGES 4 1/2' ANTI —FRICTION BEARING HINGES
FINISH- MATCH EXISTING
1 LOCKSET BLDG. STD. LEVER STOREROOM LOCKSET
FINISH: MATCH EXISTING
1 CLOSER W/HOLD ADA COMPLIANT "LCN CLOSERS" OR EQUAL: 4040XP
OPEN SERIES SMOOTHIE (PULL —SIDE OR PULL MOUNTED)
FINISH: POWDER COAT FINISH: MATCH EXISTING
I FLOOR STOP "IVES' p436
FINISH: MATCH EXISTING
4 RUBBER
SILENCERS
SET 15
- CLOSET
DUMMY TRIM (PAIR
OF DOORS)
4 PAIR HINGES 4 1/2" ANTI —FRICTION BEARING HINGES
FINISH: MATCH EXISTING
2 DUMMY TRIM BLDG. STD. LEVER DUMMY TRIM
FINISH: MATCH EXISTING
2 MAGNETIC CATCHES
2 OVERHEAD STOPS
4 RUBBER SILENCERS
DOOR TYPES
SCALE: 3/8" = 1'-01,
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Central
�VT�ID.MAWaAL.
DATE: 10/23/19
'RIXSOW 010 SERIES OVERHEAD STOP
FINISH: MATCH EXISTING
I LOCKSET BLDG. STD. STOREROOM LEVER LOCKSET
FINISH: MATCH EXISTING
I POWER SUPPLY GC TO PROVIDE ALL POWER TO STRIKE POWER
SUPPLY AS REQUIRED. COORDINATE WITH SECURITY
VENDOR
I FLOOR STOP "IVES" d436
FINISH: MATCH EXISTING
4 RUBBER SILENCERS
BY TENANT'S SECURITY VENDOR:
I CARD READER
I MOTION DETECTOR DEVICE
VSTALLATION TO BE COORDINATED WITH
DOWER. CORRIDOR TRIM IS ELECTRICALLY
JVERRIDE. INTERIOR TRIM IS ALWAYS FIRE
REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. ALL ACCE'
CONTROLLED DOORS WILL MEET THE REQUIREMENTS OF INDIANA STATE
G.C. TO COORDINATE 'J° BOX LOCATION FOR THE CARD READERS WITH
TENANT'S SECURITY VENDOR.
SET #7 - ELECTRIC STRIKE WITH CLOSER (MOTHER'S ROOM)
BY GENERAL CONTRACTOR:
2 HINGES 4 1/2" ANTI —FRICTION BEARING HINGES
FINISH: MATCH EXISTING
I CLOSER 'ADA COMPLIANT LCN CLOSERS" OR EQUAL: 4040XP
SERIES (PUSH SIDE MOUNTED) WITH 72MC
METAL COVER
FINISH: MATCH EXISTING
I ELEC. STRIKE HES, SERIES 1006CS , .25 AMPS ® 24VDC WITH HES
SMART PAC III ON FAIL SAFE HARDWARE
FINISH: MATCH EXISTING
I LOCKSET BLDG. STD. STOREROOM LEVER LOCKSET
FINISH: MATCH EXISTING
I DEADBOLT SCHLAGE L SERIES OR APPROVED EQUAL
VACANT/OCCUPIED THUMBTURN INDICATOR DEADBOLT
FINISH: MATCH EXISTING
I POWER SUPPLY GC TO PROVIDE ALL POWER TO STRIKE POWER
SUPPLY AS REQUIRED. COORDINATE WITH SECURITY
VENDOR
I FLOOR STOP "IVES" 8436
FINISH: MATCH EXISTING
4 RUBBER SILENCERS
BY TENANT'S SECURITY VENDOR:
I CARD READER
I MOTION DETECTOR DEVICE
INSTALLATION TO BE COORDINATED WITH THE LANDLORD. PROVIDE 24V DC
POWER. CORRIDOR TRIM IS ELECTRICALLY UNLOCKED BY CARD READER OR KEY
OVERRIDE. INTERIOR TRIM IS ALWAYS FREE FOR IMMEDIATE EGRESS. AS
REQUIRED, ACCESS CONTROLLED DOORS WILL BE TIED TO THE LIFE SAFETY
SYSTEM REFER TO ENGINEERS DRAWINGS FOR FURTHER INFORMATION. ALL
ACCESS CONTROLLED DOORS WILL MEET THE REQUIREMENTS OF INDIANA STATE
CODE. G.C. TO COORDINATE "J" BOX LOCATION FOR THE CARD READERS WITH
TENANT'S SECURITY VENDOR.
First Floor
Door
Frame
Hardware set
Remarks
Door No.
Room No.
Label
Type
Width
Height
ThL
Mat.
Finish
Type
Mat.
Finish
No.
301A
301
—
A
SINOLE
MATCH
1-3/4'
SC. WD.
ST1
2
H.M.
P2
6
3'-0'
EX.
3018
301
-
D
slle3Le
MATCH
1-3/4'
SC. WD./
STI
I
H.M.
P2
6
3'-0'
EX.
TEMP. GL
301C
301
—
D
SINGLE
MATCH
1-3/4'
SC. WD./
ST1
I
H.M.
P2
6
3'-0'
EX.
TEMP. GIL
302
302
—
A
SINGLE
MATCH
1-3/4'
SC. WD.
ST1
I
HM
P2
4
310'
EX.
303
303
—
A
SINGLE
MATCH
1-3/4'
SC. WD.
ST1
I
H.M.
P2
6
3'-0'
EX.
304
304
—
A
SINGLE
MATCH
1-3/4'
SC. WD.
ST1
I
H.M.
P2
I
3'—O'
EX.
305
305
—
A
SINGLE
MATCH
1-3/4'
SC. WD.
ST1
I
H.M.
P2
4
3'-0'
EX.
307
307
—
A
SINGLE
MATCH
1-3/4'
SC. WD.
ST1
I
H.M.
P2
2
3'O'
EX.
315
315
—
A
SINGLE
MATCH
1-3/4'
SC
ST1
2
H.M.
P2
2
3'-0'
EX.
.WD.
316
316
—
A
SINGLE
MATCH
1-3/4'
SC. WD.
ST1
I
H.M.
P2
7
3'-0'
EX.
324
324
_
C
DOUBLE
MATCH
1-3/4'
SC. WD.
ST1
4
H.M.
P2
5
(2)2'-6'
EX.
RE —KEY PER TENANT'S
328
328
—
A
EX.
EX.
EX.
EX.
EX.
EX.
EX.
P2
EX.
INSTRUCTIONS AND REMOVE
EXISTING CARD READER
332
332
—
A
SINGLE
MATCH
I-3/4'
SC .WD.
ST1
2
H.M.
P2
3
310'
EX.
336
336
—
B
SINGLE
MATCH
1-3/4'
SC. WD./
ST1
I
H.M.
P2
6
3'-0'
EX.
TEMP. GL
341
341
_
C
DOUBEE
MATCH
1-3/4'
SC
ST1
3
H.M.
P2
5
(2)3'—O'
EX.
.WD.
343
343
—
A
SINGLE
MATCH
1-3/4'
SC .WD.
ST1
2
H.M.
P2
2
310'
EX.
345
345
—
A
SINGLE
MATCH
1-3/4'
SC .WD.
ST1
2
H.M.
P2
2
310'
EX.
DOOR AND HARDWARE NOTES
I. G.C. TO PROVIDE CUT —SHEETS OF ALL HARDWARE PROPOSED, FOR ARCHITECT'S REVIEW, PRIOR TO ORDERING.
2. G.C. TO COORDINATE HARDWARE PURCHASE, SPECIFICATION AND INSTALLATION WITH BUILDING MANAGEMENT.
3. FURNISH 2 PAIR HINGES PER LEAF, UNLESS OTHERWISE NOTED. FURNISH HINGES WITH STAINLESS STEEL PINS AND CONCEALED BEARINGS. SIZE LISTED
IN HARDWARE SETS INDICATES HEIGHT.
4. FURNISH SILENCERS FOR ALL INTERIOR FRAMES; 3 FOR SINGLE DOORS, 4 FOR PAIR OF DOORS. OMIT WHERE SOUND OR LIGHT SEAL OCCURS.
5. ALL LEVER SETS TO BE 3'-3' FROM THE BOTTOM OF THE DOOR TO THE CENTER OF THE LEVER.
6. INSTALL EACH HARDWARE ITEM PER MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS. DO NOT INSTALL SURFACE MOUNTED ITEMS UNTIL
FINISHES HAVE BEEN COMPLETED ON THE SUBSTRATE. SET UNITS LEVEL, PLUM AND TRUE TO LINE AND LOCATION.
7. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR TO ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT. REPLACE
UNITS WHICH CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY.
S. KEYING OF CYLINDER LOCKS SHALL BE COORDINATED WITH THE OWNER, FOR ESTIMATE USE GRANDMASTER KEYING CHARGE. UNDER OWNER'S
DIRECTION, KEY TO NEW OR EXISTING SYSTEM TO BE APPROVED BY OWNER'S REPRESENTATIVE IN WRITING. FURNISH CONSTRUCTION KEY SYSTEM
WITH KEYS THAT CAN BE RENDERED INOPERATIVE BY THE TURN OF A CHANGE KEY. STAMP ALL KEYS 'DO NOT DUPLICATE*. FOR PROTECTION OF
THE OWNER, ALL LOCKS AND CYLINDERS SHALL BE KEYED AT THE FACTORY OF THE LOCK MANUFACTURER WHERE PERMANENT RECORDS ARE
MAINTAINED.
9. LIBERTY MUTUAL SHALL RECEIVE THREE KEYS FOR EACH LOCK AND SIX MASTER KEYS FOR EACH SET. REVIEW WITH LANDLORD OR BUILDING MANAGER IF
THEY REQUIRE A BUILDING APPROVED LOCKSMITH FOR ALL KEY AND LOCK WORK. ALL LOCKSETS MUST HAVE A BEST ACCESS 7 PIN I/C CORE,
10. ALL EXIT DOORS SCHEDULED WITH ELECTRONIC HARDWARE SHALL UNLOCK UPON THE ACTUATION OF A LIFE SAFETY DEVICE. ALL DOORS REQUIRED AS
EXITS WITH ELECTRONIC HARDWARE UNLOCK UPON THE LOSS OF POWER CONTROLLING THE LOCK OR LOCK MECHANISM. ALL DOORS REQUIRED AS
EXITS WITH ELECTRONIC HARDWARE SHALL HAVE THE CAPABILITY OF BEING UNLOCKED BY A SIGNAL FROM THE FIRE COMMAND CENTER IN HIGH RISE
BUILDING WHERE APPLICABLE.
It.
TELECOM ROOM DOORS TO BE FAIL SECURE, ALL OTHER SHALL BE FAIL SAFE. ALL CARD READERS WILL BE TIED TO THE LIFE SAFETY SYSTEM AND
WILL MEET THE REQUIREMENTS OF THE STATE CODE.
12.
O.C. WILL BE RESPONSIBLE TO TOUCH—UP THE STAIN AND FINISH
OF REUSED, SALVAGED DOORS TO A
'LIKE —NEW APPEARANCE. FINISH ON EXISTING
GLASS SUITE ENTRY DOORS TO BE POLISHED AND RETURNED TO
A 'LIKE —NEW FINISH.
13.
ALL CLOSERS TO BE ADA COMPLIANT.
14.
NEW HARDWARE TO MATCH EXISTING IN FINISH AND STYLE. THE
GRADE OF HARDWARE MUST BE EQUAL
OR BETTER THAN EXISTING.
15.
G.C. TO PAINT ALL EXISTING DOOR FRAMES TO REMAIN 'P2' AND
ALL EXISTING PAINT GRADE DOOR TO
REMAIN 'P20.
FRAME TYPES
SCALE: 3/8" = 1'-0"
2
2' 1•_6. 2' '_ 2'
2' 6'_0• 2' 2' 5•_0• 2'
O O O O
H
E
L
L Y E R
LEWIS=
ARCHITECTURE
INTERIOR DESIGN
Project:
C'
Liberty
i=?
4
sINSURANCE
450 East 96th St
3rd Floor
Indianapolis IN 46240
Drawing:
Door and
Hardware
Schedules
NO. A-5.00