HomeMy WebLinkAboutA-8.00GENERAL CONDITIONS
1. THE AMERICAN INSTITUTE OF ARCHITECTS 'GENERAL CONDITIONS OF CONTRACTS FOR
CONSTRUCTION* AND SUPPLEMENTAL CONDITION REQUIREMENTS (CURRENT EDITIONS)
SHALL RELATE TO THE WORK OF THE PROJECT AND IS HEREBY MADE APART OF
THESE CONTRACT DRAWINC35 AS THOUGH FULLY CONTAINED. THESE DOCUMENTS SHALL
APPLY TO THE FOLLOWING BUT NOT BE LIMITED TO:
A. COMPLIANCE WITH ALL NATIONAL. STATE AND LOCAL CODES.
B. SHOP DRAWINGS WHEN REQUIRED.
C. RUBBISH REMOVAL.
2. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL PERMITS,
INSPECTIONS AND LICENSES NECESSARY FOR THE PROPER EXECUTION AND
COMPLETION OF THE WORK, AND OCCUPANCY OF THE SPACE BY THE TENANT. ALL
PERMIT FEES ARE TO BE INCLUDED IN BID PRICING AND ARE TO BE PAID BY THE
GENERAL CONTRACTOR.
3. THE DRAWINGS AND THE NOTES ON THIS SHEET ARE INTENDED TO BE
COMPLEMENTARY. SPECIFIC INFORMATION MAY BE FOUND IN EITHER OR BOTH.
DISCREPANCIES OR CONFLICTING INFORMATION BETWEEN THE DRAWINGS AND THESE
NOTES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT IMMEDIATELY
DURING THE PRICING PHASE. ANY DISCREPANCIES OR CONFLICTS BROUGHT TO THE
ARCHITECT'S ATTENTION AFTER THE AWARD OF THE CONTRACT SHALL BE RESOLVED
BY THE ARCHITECT DETERMINING WHICH CONFLICTING ITEM SHALL GOVERN As THE
GENERAL CONTRACTOR'S INSTRUCTIONS REGARDING EXECUTION OF THE WORK AT NO
ADDITIONAL COST TO THE TENANT, ARCHITECT, OWNER OR ANY OF THEIR
REPRESENTATIVES OR CONSULTANTS.
4. THE GENERAL CONTRACTOR SHALL LAY OUT THE WORK IN CONFORMITY WITH THE
REQUIREMENTS OF CONTRACT DOCUMENTS, AND WILL BE HELD RESPONSIBLE FOR
PROPER ESTABLISHMENT AND MAINTENANCE OF ALL LINES AND DIMENSIONS. BEFORE
DOING MY WORK, THE GENERAL CONTRACTOR SHALL VERIFY ALL MEASUREMENTS AND
CONDITIONS AT SITE AND NOTIFY THE ARCHITECTS OF ANY DISCREPANCIES.
RESULTING ERRORS CAUSED BY THE FAILURE OF THE GENERAL CONTRACTOR TO
EXERCISE SUCH PRECAUTIONS SHALL NOT BE CONSIDERED SUBSEQUENTLY AS A BASIS
FOR ADDITIONAL COMPENSATION.
S. ALL WORK. MATERIALS AND INSTALLATION SHALL BE IN STRICT ACCORDANCE WITH ALL
OCCUPANCIES, STATE AIRD LOCAL BUILDING CODES (LATEST EDITIONS).
6. IT IS ANTICIPATED THAT THE TENANT MAY AWARD SEPARATE CONTRACTS FOR WORK
NOT INCLUDED IN THIS PROJECT. WHILE IT IS NOT THE CONTRACTORI
RESPONSIBILITY TO MANAGE AND SUPERVISE OTHER CONTRACTS NEGOTIATED DIRECTLY
WITH THE TENANT, IT 15 HIS RESPONSIBILITY TO INFORM THE TENANT AND ARCHITECT
IN A TIMELY FASHION OF CRITICAL DATES WHEN SUCH TRADES SHOULD COMMENCE
AND COMPLETE WORK IN ORDER NOT TO JEOPARDIZE THE CONSTRUCTION CONTRACT
COMPLETION SCHEDULE. SEPARATE CONTRACTS MAY INCLUDE, BUT ARE NOT LIMITED
TO THE FOLLOWING:
1. INSTALLATION OF FURNITURE AND INSTALLATION AND ASSEMBLY OF SYSTEM
FURNITURE.
2. INSTALLATION OF TELEPHONE EQUIPMENT.
3. INSTALLATION OF COMPUTER EQUIPMENT.
4. INSTALLATION OF TELEPHONE AND DATA CABLING.
5. INSTALLATION OF SECURITY SYSTEM.
6. INSTALLATION OF AUDIO/VISUAL EQUIPMENT.
7. GENERAL: DURING THE CONSTRUCTION PERIOD THE CONTRACTOR SHALL HAVE FULL USE
OF THE AREAS WITHIN THE CONTRACT LIMITS INDICATED ON THE DRAWINGS, LIMITED
ONLY BY THE BLDG. OWNEIR'S AND TENI RIGHT TO PERFORM CONSTRUCTION
OPERATIONS WITH ITS OWN FORCES OR TO EMPLOY SEPARATE CONTRACTORS ON
PORTIONS OF THE PROJECT.
8. MOUNTING HEIGHTS: WHERE MOUNTING HEIGHTS WE NOT INDICATED, INSTALL INDIVIDUAL
COMPONENTS AT STANDARD MOUNTING HEIGHTS RECOGNIZED WITHIN THE INDUSTRY
FOR THE PARTICULAR APPLICATION INDICATED. REFER QUESTIONABLE MOUNTING HEIGHT
DECISIONS TO THE ARCHITECT FOR FINAL DECISION.
9. TEMPORARY TRASH STORAGE AND REMOVAL. THE GENERAL CONTRACTOR SHALL MAKE
PROVISIONS AND COORDINATE WITH THE BUILDING OWNER TO PROVIDE ARRANGEMENTS
FOR THE STORAGE MD REMOVAL OF ALL CONSTRUCTION DEBRIS AND SHALL PAY FOR
ALL COSTS AS THEY ARISE FOR SUCH PROVISIONS.
10. THE CONTRACTORS SHALL USE DIMENSIONS ONLY, DO NOT SCALE PLANS. ALL
DIMENSIONS ARE TO FINISHED FACE UNLESS OTHERWISE NOTED.
11. PROTECTION OF WORK IN PLACE: WORK THAT IS SUBJECT TO INJURY BECAUSE OF
OPERATIONS BEING CARRIED ON IN ADJACENT AREAS THERETO SHALL BE COVERED,
BOARDED UP, OR SUBSTANTIALLY ENCLOSED WITH ADEQUATE PROTECTION. ALL FORMS
OF PROTECTION SHALL BE CONSTRUCTED IN A MANNER SUCH THAT, UPON
COMPLETION, THE ENTIRE WORK WILL BE DELIVERED TO THE TENANT IN PROPER,
WHOLE AND UNBLEMISHED CONDITION.
12. MATERIALS: ALL MANUFACTURED ARTICLES, MATERIALS AND EQUIPMENT SHALL BE APPLIED
AS RECOMMENDED BY MANUFACTURERS. ALL LIKE MATERIALS USED SHALL BE OF THE
SAME MANUFACTURER AND QUALITY UNLESS OTHERWISE SPECIFIED.
15. WORKMANSHIP: ALL WORK UNDER THIS CONTRACT SHALL BE PERFORMED BY
COMPETENT WORKMEN, AND EXECUTED IN A NEAT WORKMAN -LIKE MANNER. ALL
MATERIALS AND WORKMANSHIP SHALL BE GUARANTEED FOR ONE YEAR AFTER THE DATE
OF ACCEPTANCE BY THE TENANT.
14. SHOP DRAWINGS: SHOP DRAWINGS MID CATALOG DATA ON ALL MAJOR ITEMS OF
EQUIPMENT AND SYSTEMS, AND SUCH OTHER ILLUSTRATIVE MATERIALS AS MAY BE
CONSIDERED NECESSARY BY THE ARCHITECT I& AS CALLED FOR IN THESE NOTES) ME
TO BE SUBMITTED BY THE G.C. IN ADEQUATE TIME TO PREVENT DELAYS OR CHANGES
DURING CONSTRUCTION. ELECTRONIC DRAWINGS AND PRINTS ARE REQUIRED FOR EACH
SUBMITTAL. ALL SUBMITTALS ARE TO BE REVIEWED BY THE GENERAL CONTRACTOR
BEFORE BEING SENT TO THE ARCHITECT. SEND SUBMITTALS TO SCOTT PEARSON AT
HELLYER LEWIS INC., 211 S. 12TH STREET PHILADELPHIA PA 19107
15. ANY AND ALL WELDING TO THE BUILDINGS STRUCTURE MUST BE APPROVED IN WRITING
BY THE BUILDING OWNER'S REPRESENTATIVE. .
16. DESIGN LOADS: LOADS AND CODE RESTRICTIONS FOR ALL DESIGN CONSIDERATIONS
SHALL CONFORM TO ALL ORDINANCES AND STATE AND LOCAL BUILDING CODES (LATEST
EDITION).
17. GENERAL CONTRACTOR SHALL REMOVE, REPLACE, RESTORE OR SATISFACTORILY REPAIR
ANY PARTS OF THE WORK WHICH ARE BROKEN, MISSING, STRUCTURALLY UNSAFE OR
UNSOUND, BENT, TORN OR OTHERWISE DEFICIENT OR INJURED IN ANY MANNER, AS
DIRECTED BY THE ARCHITECT.
18. THROUGHOUT CONSTRUCTION PERIOD, KEEP PROJECT SITE CLEAN AND NEAT IN
APPEARANCE. DO NOT ALLOW HAZARDOUS DANGEROUS OR UNSANITARY CONDITIONS, OR
PUBLIC NUISANCES TO DEVELOP OR PERSIST ON THE SITE. EMPLOY EXPERIENCED
WORKERS OR PROFESSIONAL CLEANERS FOR FINAL CLEANING. CLEAN EACH SURFACE OR
UNIT TO THE CONDITION EXPECTED IN A NORMAL. COMMERCIAL BUILDING CLEANING AND
MAINTENANCE PROGRAM. COMPLY WITH MANUFACTURER'S INSTRUCTIONS.
19. GENERAL CONTRACTOR TO PROVIDE ALL TEMPORARY LIGHTING AS REQUIRED DURING
CONSTRUCTION.
r
LililloislItiollel*lx4C[W:
1. ANY CONTRACTORS REQUIRED TO TRENCH OR CHIP CONCRETE FLOOR SLABS FOR
THEIR PORTION OF THE WORK, SHALL BE RESPONSIBLE TO BACKFILL AND PATCH AS
REQUIRED TO RETURN THE SLAB TO ITS ORIGINAL CONDITION.
2. SEE THE DEMOLITION. ARCHITECTURAL AND FINISH PLANS FOR ADDITIONAL NOTES
REGARDING THE EXISTING CONCRETE FLOOR.
05 00 00 METALS
1. METAL STUDS: GALVANIZED STEEL STUDS SIZE AS INDICATED ON DRAWINGS OR AS
REQ'D AND ARE TO INCLUDE ALL ACCESSORIES, SUCH AS BRIDGING, TRACK, ETC.
PROVIDE ALL MISCELLANEOUS BOLTS, CLIPS, ANCHORS, ANGLES, BRACKETS, SLEEVES,
FASTENERS, AND OTHER METAL ITEMS AS REQUIRED.
2. INSTALL PUPPETRY FRAMING, BLOCKING AND BRACING IN METAL FRAMING SYSTEM
WHEREVER WALLS OR PARTITIONS ME INDICATED TO SUPPORT FIXTURES, EQUIPMENT,
SERVICES, CASEWORK, HEAVY TRIM, FURNISHINGS AND SIMILAR WORK REQUIRING
ATTACHMENT TO THE WALL TO PARTITION,
06 1 0 00 ROUGH CARPENTRY
1. THE GENERAL CONTRACTOR 15 RESPONSIBLE FOR DETERMINING AND COORDINATING
AMOUNTS AND LOCATION OF BLOCKING REQUIRED FOR WALL MOUNTED SHELVING,
CASINETRY, COUNTERS, ETC.
2. ALL WOOD FRAMING, BLOCKING, ETC. SHALL BE FIRE RETARDANT. "ERE
FIRE-RETARTDANT-TREATEO WOOD IS SPECIFIED OR REQUIRED, COMPLY WITH
APPLICABLE REQUIREMENTS OF AWPA C20(LUMBER) AND AWPA C27 (PLYWOOD). IDENTIFY
FIRE-RIETARTOANT-TREATED WOOD WITH APPROPRIATE CLASSIFICATION MARKING OF UL
OR TESTING k INSPECTING AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION.
3. NO WOOD OR COMBUST113LE MATERIAL OF ANY KIND SHALL BE USED ABOVE THE
CEILING.
4. PLYWOOD: ALL PLYWOOD TO BE PAINTED SHALL BE PAINT GRADE BIRCH. ALL ELECTRIC
BACKBOARDS REQUIRED BY CONSTRUCTION DRAWINGS TO BE FIRE RATED PLYWOOD,
PAINTED WHITE WITH FIRE RETARDANT PAINT.
06 40 00 ARCHITECTURAL WOODWORK
1. SUBMIT THE FOLLOWING: 1) PRODUCT DATA FOR EACH TYPE OF PRODUCT AND
PROCESS SPECIFIED IN THIS SECTION AND INCORPORATED INTO ITEMS OF
ARCHITECTURAL WOODWORK DURING FABRICATION, FINISHING, AND INSTALLATION, 2)
SHOP DRAWINGS SHOWING LOCATION OF EACH ITEM, DIMENSIONED PLANS AND
ELEVATIONS, LARGE-SCALE DETAILS, ATTACHMENT DEVICES. AND OTHOR COMPONENTS.
AND 3) SAMPLES FOR VERIFICATION PURPOSES OF THE FOLLOWING:
A. PLASTIC LAMINATE.
B. EXPOSED CABINET HARDWARE. ONE UNIT OF EACH TYPE AND FINISH.
C. LUMBER FOR TRANSPARENT FINISH. 50 60. INCHES FOR EACH SPECIES AND
CUT, FINISHED ON ONE SIDE AND ONE EDGE.
2. INSTALLER QUALIFICATIONS: ARRANGE FOR INSTALLATION OF ARCHITECTURAL
WOODWORK BY A FIRM THAT CAN DEMONSTRATE SUCCESSFUL EXPERIENCE IN
INSTALLING ARCHITECTURAL WOODWORK ITEMS SIMILAR IN TYPE AND QUALITY TO
THOSE REQUIRED FOR THIS PROJECT.
3. AWI QUALITY STANDARD: COMPLY WITH APPLICABLE REQUIREMENTS OF 'ARCHITECTURAL
WOODWORK STANDARDSO (AWS) PUBLISHED BY THE ARCHITECTURAL WOODWORK
INSTITUTE (AWI) EXCEPT AS OTHERWISE INDICATED.
4. HARDWARE COORDINATION: DISTRIBUTE COPIES OF APPROVED SCHEDULLE FOR CABINET
HARDWARE INDICATED ON THE ARCHITECTS DRAWINGS TO THE MANUFACTURER OF
ARCHITECTURAL WOODWORK; COORDINATE CABINET SHOP DRAWINGS AND FABRICATION
WITH HARDWARE REQUIREMENTS.
5. FIELD MEASUREMENTS: WHERE WOODWORK IS INDICATED TO BE FITTED TO OTHER
CONSTRUCTION, CHECK ACTUAL DIMENSIONS OF OTHER CONSTRUCTION BY ACCURATE
FIELD MEASUREMENTS BEFORE MANUFACTURING WOODWORK; SHOW RECORDED
MEASUREMENTS ON FINAL SHOP DRAWINGS. COORDINATE MANUFACTURING SCHEDULE
WITH CONSTRUCTION PROGRESS TO AVOID DELAY OF WORK. WHERE FIELD
MEASUREMENTS CANNOT BE MADE WITHOUT DELAYING THE WORK, GUARANTEE
DIMENSIONS AND PROCEED WITH MANUFACTURE OF WOODWORK WITHOUT FIELD
MEASUREMENTS. COORDINATE OTHER CONSTRUCTION TO ENSURE THAT ACTUAL
DIMENSIONS CORRESPOND TO GUARANTEED DIMENSIONS.
6. PROVIDE MATERIALS THAT COMPLY WITH REQUIREMENTS OF THE AWI WOODWORKING
STANDARD FOR EACH TYPE OF WOODWORK AND QUALITY GRADE INDICATED.
7. WOOD MOISTURE CONTENT COMPLY WITH REQUIREMENTS OF REFERENCED QUALITY
STANDARD FOR MOISTURE CONTENT OF LUMBER IN RELATION TO RELATIVE HUMIDITY
CONDITIONS EXISTING DURING TIME OF FABRICATION AND IN INSTALLATION AREAS.
S. COMPLETE FABRICATION. INCLUDING ASSEMBLY. FINISHING, AND HARDWARE APPLICATION,
BEFORE SHIPMENT TO PROJECT SITE TO MAXIMUM EXTENT POSSIBLE. DISASSEMBLE
COMPONENTS ONLY AS NECESSARY FOR SHIPMENT AND INSTALLATION. WHERE
NECESSARY FOR FITTING AT SITE, PROVIDE AMPLE ALLOWANCE FOR SCRIBING,
TRIMMING, AND FITTING.
9. STANDING AND RUNNING WOOD BASE W/ OPAQUE FINISH IS TO CONFORM TO AND
COMPLY W/ AW.S. SECTIONS 5 AND S FOR THE GRADE(S) SPECIFIED HEREIN. BACKOUT
OR GROOVE BACKS OF FLAT TRIM MEMBERS AND KERF BACKS OF OTHER WIDE FLAT
MEMBERS, EXCEPT FOR MEMBERS WITH ENDS EXPOSED IN FINISHED WORK. ASSEMBLE
CASINGS IN FACTORY EXCEPT WHERE LIMITATIONS OF ACCESS TO PLACE OF
INSTALLATION REQUIRE FIELD ASSEMBLY. FIELD VERIFY LIMITATIONS OF SITE ACCESS
PRIOR TO FABRICATION. FOR STANDING AND RUNNING TRIM AND RAILS WITH OPAQUE
FINISH COMPLY WITH THE REQUIREMENTS INDICATED BELOW:
A.W.S GRADE: CUSTOM
SPECIES: POPLAR
10. RUNNING WOOD BASE AND WOOD DOOR FRAIvES WITH TRANSPARENT FINISH ARE TO
RELEASED FOR CONSTRUCTION Y W/ A.W.8. SECTION 5 AND 6 FOR THE GRADE(6) SPECIFIED
OVE BACKS OF FLAT TRIM MEMBERS AND KERF BACKS OF
RE. EXCEPT FOR MEMBERS WITH ENDS EXP06EO IN FINISHED
SUbjeCt to CINTIpliance wIth all regulations 1 IN PLANT EXCEPT WHERE LIMITATIONS OF ACCESS TO
of State and Local Codes �EQUIRIE FIELD ASSEMBLY. FOR RUNNING WOOD BASE AND
TRAIRSPARENT FINISH COMPLY WITH THE REQUIREMENTS
City at Carnmel
USTOM
� G�ma�z R
06 40 00 ARCHITECTURAL WOODWORK (CONTINUED)
11. LAMINATE CLAD CABINETS (PLASTIC -COVERED CASEWORK) AND COUNTERTOPS ARE
TO COMPLY WITH AWS SECTION 4 AND 10. GRADE IS TO 13E CUSTOM AND CABINET
CONSTRUCTION IS TO BE FLUSH OVERLAY.
12. CLOSET AND UTILITY SHELVING IS TO CONFORM TO AND COMPLY WITH AW.S.
SECTION 6. COMPLY WITH THE REQUIREMENTS INDICATED BELOW.
AW.S. GRADE: CUSTOM
SPECIES: POPLAR OR BIRCH
13. WOOD SIDELIGHTS WITH TRANSPARENT FINISH ARE TO CONFORM TO AND COMPLY
W/ A.W.S. SECTION 6 FOR THE ORADE(S) SPECIFIED HEREIN. COMPLY WITH
REQUIREMENTS INDICATED BELOW.
AW.S. GRADE: PREMIUM.
SPECIES: MATCH EXISTING
14. WOOD SIDELIGHTS WITH OPAQUE FINISH ARE TO CONFORM TO AND COMPLY W/
AW.S. SECTION 6 FOR THE GRADE(S) SPECIFIED HEREIN. COMPLY WITH
REQUIREMENTS INDICATED BELOW.
AW.S. GRADE: CUSTOM
SPECIES: POPLAR
15. FOR ALL WOOD TO HAVE TRANSPARENT FINISH COMPLY WITH A.W.S. SECTION 5
AND WITH THE REQUIREMENTS INDICATED BELOW.
A,W.S. GRADE: PREMIUM.
AWS FINISH SYSTEM: SYSTEM 5, CONVERSION VARNISH
STAINING: MATCH APPROVED SAMPLE FOR COLOR.
EFFECT: CLOSED 3WAIN.
SHEEN: SATIN 30-50 DEG.
16. CABINET HARDWARE STANDARD COMPLY WITH ANSII A156.9 "AMERICAN
NATIONAL STANDARD FOR CABINET HARDWARE" FOR ITEMS INDICATED BY REFERENCE
TO SIENA NUMBERS OR REFERENCED TO THIS STANDARD.
17. FOR CONCEALED HARDWARE PROVIDE MANUFACTURERPS STANDARD FINISH THAT
COMPLIES WITH PRODUCT CLASS REQUIREMENTS OF ANSI/SHMA A156.9.
18. PREPARATIONS FOR FINISHING: COMPLY WITH REFERENCED QUI STANDARD FOR
SANDING. FILLING COUNTERSUNK FASTENERS. SEALING CONCEALED SURFACES AND
SIMILAR PREPARATIONS FOR FINISHING OF ARCHITECTURAL WOODWORK, AS
APPLICABLE TO EACH UNIT OF WORK.
19. INSTALL WOODWORK TO COMPLY WITH AWS EXECUTION SECTION FOR SAME GRADE
SPECIFIED IN THIS SECTION FOR TYPE OF WOODWORK INVOLVED.
20. INSTALL WOODWORK PLUMB, LEVEL, TRUE, AND STRAIGHT WITH NO DISTORTIONS.
SHIM AS REQUIRED WITH CONCEALED SHIMS. INSTALL TO A TOLERANCE OF I/e INCH
IN S'-O� FOR PLUMB AND LEVEL (INCLUDING TOPS) AND WITH NO VARIATIONS IN
FLUSHNESS OF ADJOINING SURFACES.
21. SCRIBE AND CUT WOODWORK TO FIT ADJOINING WORK AND REFINISH CUT
SURFACES OR REPAIR DAMAGED FINISH AT CUTS.
22. ANCHOR WOODWORK TO ANCHORS OR BLOCKING BUILT IN OR DIRECTLY ATTACHED
TO SUBSTRATES. SECURE TO GROUNDS, STRIPPING AND BLOCKING WITH
COUNTERSUNK, CONCEALED FASTENERS AND 13LIND NAILING AS REQUIRED FOR A
COMPLETE INSTALLATION. EXCEPT WHERE PREFINISHED MATCHING FASTENER HEADS
ARE REQUIRED, USE FINE FINISHING NAILS FOR EXPOSED NAILING, COUNTERSUNK AND
FILLED FLUSH WITH WOODWORK.
23. STANDING AND RUNNING TRIM AND RAILS: INSTALL WITH MINIMUM NUMBER OF
JOINTS POSSIBLE, USING FULL-LENGTH PIECES (FROM MAXIMUM LENGTH OF LUMBER
AVAILABLE) TO THE GREATEST EXTENT POSSIBLE. STAGGER JOINTS IN ADJACENT
AND RELATED MEMBERS. COPE AT RETURNS AND MITER AT CORNERS.
24. CABINETS: INSTALL WITHOUT DISTORTION SO THAT DOORS AND DRAWERS FIT
OPENINGS PROPERLY AND ARE ACCURATELY ALIGNED. ADJUST HARDWARE TO
CENTER DOORS AND DRAWERS IN OPENINGS AND TO PROVIDE UNENCUMBERED
OPERATION. COMPLETE THE INSTALLATION OF HARDWARE AND ACCESSORY ITEMS
AS INDICATED.
25. TOPS: AIRCHOR SECURELY TO BASE UNITS AND OTHER SUPPORT SYSTEMS AS
INDICATED.
M COMPLETE THE FINISHING WORK SPECIFIED IN THIS SECTION TO WHATEVER EXTENT
NOT COMPLETED AT SHOP OR BEFORE INSTALLATION OF WOODWORK.
2T REPAIR DAMAGED AND DEFECTIVE WOODWORK WHERE POSSIBLE TO ELIMINATE
DEFECTS FUNCTIONALLY AND VISUALLY; WHERE NOT POSSIBLE TO REPAIR. REPLACE
WOODWORK. ADJUST JOINERY FOR UNIFORM AFPEARANCE.
28. CLEM, LUBRICATE, AND ADJUST HARDWARE.
07 92 00 SEALANTS
1. PROVIDE SEALANTS WHERE SHOWN ON THE DRAWINGS AND AT ALL HORIZONTAL AND
VERTICAL JOINTS BETWEEN SIMILAR AND DISSIMILAR MATERIALS. INCLUDING, BUT NOT
LIMITED TO:
kPERIMETER OF DOORS AND FRAMES
B.CONTROL AND EXPANSION JOINTS IN FLOORS, WALLS, AND CEILINGS
C.BETWEEN EXISTING AND NEW CONSTRUCTION
D.PERIMETER OF ALL WALLS CONTAINING ACOUSTIC BLANKETS
E.WALL PERIMETERS AND PENETRATIONS
F.AT CONTINUOUS FLASHING / WEEPHOLE LOCATIONS
G.WHERE RECOMMENDED BY OTHER MATERIAL SUPPLIERS
2. SUBMITTALS. SUBMIT PRODUCT DATA FOR EACH JOINT -SEALANT PRODUCT INDICATED.
PROVIDE SAMPLES FOR EACH KIND AND COLOR OF JOINT SEALANT REQUIRED.
3. PROVIDE SEALANTS RECOMMENDED BY THE MANUFACTURER FOR THE INTENDED
PURPOSE.
4. COMPLY WITH ASTM C920.
5. COLORS SHALL BE CHOSEN BY THE ARCHITECT FROM THE FULL RANGE OF
AVAILABLE COLORS.
6. FOR GENERAL USE, EXCEPT AS NOTED BELOW: ONE PART, NON-ACID CURING
SILICONE SEALANT *864" OR "e95� BY PECORA
7. FOR SANITARY APPLICATIONS: ONE PART, MILDEW RESISTANT SILICONE *e63* BY
PECORA
8. FOR PAINTABLE APPLICATIONS: "TRADE MATE PAINTASLE' BY DOW CORNING
9. FOR HORIZONTAL TRAFFIC JOINTS: 'DYNATRED' TWO PART URETHANE 13Y PECORA
10. FOR ACOUSTIC& JOINTS: 'AC-20' BY PECORA
11. FOR JOINTS IN SUBSTRATES FURNISHED BY A SINGLE MANUFACTURER, PROVIDE
SE&MTS RECOMMENDED BY THE SYSTEM MANUFACTURER.
12. PROVIDE CLEANERS, PRIMERS, BACKERS, BOND BREAKERS, AND OTHER ACCESSORIES As
RECOMMENDED BY THE SEALANT MANUFACTURER.
13. INSTALL SEALANTS IN ACCORDANCE WITH MANUFACTURER'S WRITTEN INSTRUCTIONS
AND ASTM C1193.
14. DO NOT INSTALL SEALANTS ON SUBSTRATES THAT ARE DAMP OR CONTAIN
IMPURITIES THAT COULD REDUCE ADHESION.
15. INSTALL SEALANTS WHEN THE AMBIENT TEMPERATURE IS ABOVE 5OF AND BELOW
901F.
16. INSTALL SEALANT ACCESSORIES INCLUDING BOND BREAKER TAPE AND FOAM BACKER
ROD.
17. TOOL ALL JOINTS CONCAVE EXCEPT: EXPOSED JOINTS IN CLEM ROOMPS, USE FLUSH
TOOLED JOINTS WHERE FINISHED SURFACES ARE CO -PLANER.
nk nn DID nnnpq
1. THE GENERAL CONTRACTOR SHALL INSTALL ALL DOORS, FRAMES AND HARDWARE
AND RELATED PARTS AND MATERIALS AS INDICATED ON THE DRAWINGS, ON THE
DOOR SCHEDULE &AS SPECIFIED HEREIN. ALL DOORS, FRAMES &HARDWARE SHALL
BE FABRICATED AND ERECTED TRUE, PLUMB A SQUARE AS SPECIFIED, AS DETAILED
AND PER MANUFACTUREIR'S RECOMMENDATIONS.
2. SUBMIT DOOR MANUFACTURER'S TECHNICAL DATA FOR EACH TYPE OF DOOR,
INCLUDING DETAILS OF CORE AND EDGE CONSTRUCTION, TRIM FOR OPENINGS AND
LOUVERS, AND FACTORY -FINISHING SPECIFICATIONS. SUBMIT SHOP DRAWINGS
INDICATING LOCATION AND 61ZE OF EACH DOOR. ELEVATION OF EACH KIND OF
DOOR, DETAILS OF CONSTRUCTION, LOCATION AND EXTENT OF HARDWARE
BLOCKING, FIRE RATINGS. REQUIREMENTS FOR FACTORY FINISHING AND OTHER
PERTINENT DATA INCLUDING DIMENSIONS AND LOCATIONS OF CUTOUTS FOR
LOCK5ETS. ALSO, SUBMIT SAMPLES. I-O" SQUARE SAMPLE OF DOOR FOR
TRANSPARENT FINISH SHOWING DOOR FACES WITH SOLID WOOD EDGING
REPRESENTING TYPICAL RANGE OF COLOR AND GRAIN OF VENEER AND SOLID
LUMBER REQUIRED. DOOR SCHI USE SAME REFERENCED DESIGNATIONS
INDICATED ON DRAWINGS IN PREPARING SCHEDULE FOR DOORS k FRAMES.
3. ALL FLUSH WOOD DOORS TO COMPLY WITH THE FOLLOWING STANDARDS: NWWDA
QUI STANDARD I "INDUSTRY STANDARD FOR WOOD FLUSH DOORS', OF
NATIONAL WOOD WINDOW AND DOOR ASSOCIATION (NWWDA), AND AWI QUALITY
STANDARD: "ARCHITECTURAL WOODWORK STANDARDS' (AWS); INCLUDING SECTION 9
AND 9.1.2.16 OARCHITECTUR� FLUSH DOORSO OF THE ARCHITECTURAL WOODWORK
STANDARD (AWS) FOR GRADE OF DOOR, CORE CONSTRUCTION. FINISH AND OTHER
REQUIREMENTS EXCEEDING THOSE OF NWWDA QUI STANDARD. MARK EACH
WOOD DOOR WITH NWWDA WOOD FLUSH DOOR CERTIFICATION HALLMARK
CERTIFYING COMPLIANCE WITH APPLICABLE REQUIREMENTS OF NWWDA.
4. FLUSH WOOD DOORS FOR TRANSPARENT FINISH ARE TO COMPLY W/ THE
FOLLOWING REQUIREMENTS:
AWS GRADE: PREMIUM
FACES: MATCH EXISTING
MATCHING STWN. INDIVIDUAL PIECES OF VENEER: MI STANDARD ASSEMBLY OF
VENEER ON A FACE: MFR. STANDARD
CONSTRUCTION: PC-5 (PARTICLEBOARD CORE) W/ MATCHING VERTICAL
EDGES (FOR NON -RATED DOORS), NO FINGER JTS. ALLOWED. FD-5
(MINERAL CORE) WITH MATCHING VERTICAL EDGES (FOR FIRE -RATED DOORS).
NO FINGER JTS. ALLOWED.
HARDWOOD FACE VENEER GRADE: AWI/HPVA GRADE A
5. OBTAIN FLUSH WOOD DOORS FROM A SINGLE MFR. SUBJECT TO COMPLIANCE WITH
REQUIREMENTS. PROVIDE PRODUCTS OF ONE OF THE FOLLOWING OR AN APPROVED
EQUAL.
ALGOMA HARDWOODS, INC.
EGGERS INDUSTRIES, ARCHITECTURAL DOOR DIVISION.
WEYERHAMER COMPANY.
6. WOOD STILE AND RAIL DOORS ARE TO COMPLY WITH NWWDA SECTION I
OINDUSTRY STANDARD FOR WOOD STILE AND RAIL DOORSO OF NATIONAL WOOD
WINDOW AND DOOR ASSOCIATION (NWWDA) FOR DESIGN GROUP 'FRENCH OR
CASEMENT DOORS'. ALSO COMPLY WITH 'ARCHITECTURAL WOODWORK STANDARDSO
(AWS) INCLUDING SECTION 9.1.2.19 'STILE AND RAIL DOORS' OF ARCHITECTURAL
WOODWORK INSTITUTE (AWI).
7. WOOD STILE & RAIL DOORS FOR TRANSPARENT FINISH ARE TO COMPLY WITH THE
FOLLOWING REQUIREMENTS:
WOOD SPECIES: MATCH EXISTING
STILE, RAIL AND MULLION DIMENSION AND PROFILE ARE AS INDICATED ON
DRAWINGS
AW6 GRADE: PREMIUM.
MATCHING VERTICAL EDGES - NO FINGER JOINTS ALLOWED.
S. FOR FIRE -RATED WOOD DOORS PROVIDE WOOD DOORS WHICH ME IDENTICAL IN
MATERIALS AND CONSTRUCTION TO UNITS TESTED IN DOOR AND FRAME ASSEMBLIES
PER NI NFPA252 AND ASTIM E 152 AIRD WHICH ARE LABELED AIRD LISTED FOR
RATINGS INDICATED BY ULP WARNOCK HERSEY OR OTHER TESTING AND INSPECTION
AGENCY ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION. LABELS SHALL BE
PERMANENTLY AFFIXED TO THE DOOR OR FRAME
9. SAFETY GLAZING STANDARDS PROVIDE SAFETY GLASS OF TYPE INDICATED OR
REQUIRED BY AUTHORITIES HAVING JURISDICTION FOR DOORS AND SIDELIGHTS;
COMPLY WITH ANSI Z97A AND TESTING REQUIREMENTS OF 16 CFH PART 1201 FOR
CATEGORY 11 MATERIALS EXCEPT WHERE THOSE OF CATEGORY I ARE EXPRESSLY
INDICATED AND PERMITTED. TRIM GLAZED OPENINGS W/ SOLID WOOD MOLDINGS OF
PROFILE INDICATED, REMOVABLE ONE SIDE.
10. SUBMIT WRITTEN AGREEMENT IN DOOR MANUFACTURER'S STANDARD FORM SIGNED BY
MANUFACTURER, INSTALLER AND CONTRACTOR, AGREEING TO REPAIR OR REPLACE
DEFECTIVE DOORS THAT HAVE WARPED (BOW. CUP OR TWIST) OR THAT SHOW
TELEGRAPHING OF CORE CONSTRUCTION IN FACE VENEERS, OR DO NOT CONFORM
TO TOLERANCE LIMITATIONS OF REFERENCED QUALITY STANDARDS. DOOR
WARRANTIES SHALL BE FOR THE LIFE OF EACH DOOR AND SHALL BE IN ADDITION
TO, AND NOT A LIMITATION OF, OTHER RIGHTS THE OWNER MAY HAVE UNDER THE
CONTRACT DOCUMENTS.
08 00 00 DOORS (CONTINUED)
11. FABRICATE FLUSH WOOD DOORS TO PRODUCE DOORS COMPLYING WITH SIZES
INDICATED FOR JOB -SITE FITTING. FACTORY-PREFIT AND PREMACHINE DOORS TO
FIT FRAME OPENING SIZES INDICATED. COMPLY WITH TOLERANCE REQUIREMENTS OF
AWI FOR PREFITTING. COMPLY WITH FINAL HARDWARE SCHEDULES AND DOOR FRAME
SHOP DRAWINGS AND WITH HARDWARE TEMPLATES. COORDINATE MEASUREMENTS OF
HARDWARE MORTISES IN METAL FRAMES TO VERIFY DIMENSIONS AND ALIGNMENT
BEFORE PROCEEDING WITH FACTORY PREMACHINING.
12. COMPLY WITH REFERENCED AWI QUALITY STANDARDS -INCLUDING AWS SECTION 5
'FINISHII AND 5.1.12.1. PREFINISH WOOD DOORS AT THE FACTORY. DOOR FINISHING
TO COMPLY W/ THE FOLLOWING REQUIREMENTS:
AVIS FINISH SYSTEM: SYSTEM 5-CONVERSION VARNISH OR DOOR
MANUFACTURER'S EQUIVALENT.
STAINING: MATCH APPROVED SAMPLE FOR COLOR.
EFFECT: CLOSED GRAIN.
SHEEN; SATIN 30-50 DEG,
13. INSTALL WOOD DOORS TO COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND OF
REFERENCED AWI STANDARD. INSTALL FIRE -RATED DOORS IN CORRESPONDING
FIRE -RATED FRAMES IN ACCORDANCE WITH REQUIREMENTS OF SERA NO. 80.
14. SOUND -RATED (ACOUSTICAL)ASSEMBLIES: WHERE SHOWN OR SCHEDULED, PROVIDE
DOOR AND FRAME ASSEMBLIES FABRICATED AS SOUND -REDUCING TYPE, TESTED
ACCORDING TO ASTM E 1408 AND CLASSIFIED ACCORDING TO ASTM E 413.
UNLE65 OTHERWISE NOTED PROVIDE ACOUSTICAL ASSEMBLIES WITH STC SOUND
RATINGS OF 33 OR BETTER.
15. THERMAL -RATED (INSULATING) ASSEMBLIES: AT EXTERIOR LOCATIONS AND ELSEWHERE
AS SHOWN OR SCHEDULED PROVIDE DOORS FABRICATED AS THERMAL-INKSULATING
DOOR AND FRAME ASSEMBLY AND TESTED ACCORDING TO ASTM C 23 OR ASTM C
976 ON FULLY OPERABLE DOOR ASSEMBLIES.
16. ALLOW DOORS TO BECOME ACCLIMATED TO FINISHED BUILDING HEAT AND HUMIDITY
BEFORE FITTING AND HANGING.
08 12 00 DOOR FRAMES
1. PROVIDE DOOR FRAMES W/ MITRED AND WELDED CORNERS AND SEAMLESS FACE
JOINTS COMPLYING WITH STEEL DOOR INSTITUTE wRECOMMENDED SPECIFICATIONS
STANDARD STEEL DOORS AND FRAMES- ANSI/SDIHOO, ANSI A250S AND AS SPECIFIED
HEREIN.
2. PROVIDE STEEL FRAMES FOR DOORS, TRANSOMS, SIDELIGHTS, BORROWED LIGHTS,
AND OTHER OPENINGS THAT COMPLY WITH ANSI A250.8 AND WITH DETAILS
INDICATED FOR TYPE AND PROFILE.
DOOR SILENCERS: FABRICATE STOPS TO RECEIVE THREE SILENCERS ON STRIKE
JAMBS OF SINGLE -DOOR FRAMES AND TWO SILENCERS ON HEADS OF DOUBLE -DOOR
FRAMES.
3. DOOR FRAME SUPPORTS AND ANCHORS TO BE FABRICATED FROM NOT LESS THAN
18 GAUGE SHEET STEEL GALVANIZED WHERE USED WITH GALVANIZED FRAMES.
4. ASSEMBLE DOOR FRAMES TO BE RIGID, NEAT IN APPEARANCE AND FREE FROM
DEFECTS, WARP OR BUCKLE.
5. TOLERANCES: COMPLY W/ SDI 117 OMANUFACTURING TOLIERAIRCES STANDARD STEEL
DOORS AND FRAMES.0
6. WHEN PLACING FRAMES COMPLY W/ PROVISIONS OF SDI-105 'RECOMMENDED
ERECTION INSTRUCTIONS FOR STEEL FRAMES" UNLESS OTHERWISE NOTED.
7. IN METAL STUD PARTITIONS INSTALL AT LEAST 5 WALL AIRCHORS PER JAMS AT
HINGE AND STRIKE LEVELS.
08 71 00 HARDWARE
1. ALL HARDWARE IS TO BE AS SPECIFIED ON THE ARCHITECTS DRAWINGS. SEE OWGS.
FOR STYLE AND FINISH. SET FUNCTION SHALL BE AS SCHEDULED AND AS SHOWN
ON THE DRAWINGS. ALL DOOR AND DRAWER HARDWARE (HINGES, STOPS, PULLS,
LATCHES, ETC.) MUST BE HEAVY-DUTY COMPONENTS (100 I LOAD MINIMUM).
2. MANUFACTURER: OBTAIN EACH TYPE OF HARDWARE (LATCH AND LOCK SETS, HINGES,
CLOSERS. ETC.) FROM A SINGLE MANUFACTURER, &THOUGH SEVERAL MAY BE
INDICATED AS OFFERING PRODUCTS COMPLYING WITH REQUIREMENTS.
3. FIRE -RATED OPENINGS: PROVIDE HARDWARE FOR FIRE -RATED OPENINGS IN
COMPLIANCE WITH NFPA STANDARD NO. 80 AND LOCAL BUILDING CODE
REQUIREMENTS. PROVIDE ONLY HARDWARE WHICH HAS BEEN TESTED ACCORDING TO
NFPA252 AND LISTED By UL OR FM FOR TYPES AND SIZES OF DOORS REQUIRED
AND COMPLIES WITH REQUIREMENTS OF DOOR AND DOOR FRAME LABELS.
4. PRODUCT DATA: SUBMIT MANUFACTURERS TECHNICAL PRODUCT DATA FOR EACH ITEM
OF HARDWARE. INCLUDE WHATEVER INFORMATION MAY BE NECESSARY TO SHOW
COMPLIANCE WITH REQUIREMENTS, AND INCLUDE INSTRUCTIONS FOR INSTALLATION
AND FOR MAINTENANCE OF OPERATING PARTS AND FINISHES.
COMPLY WITH ADA STATE AND LOCAL JURISDICTION REQUIREMENTS.
5. HARDWARE SCHEDULE: SUBMIT FINAL HARDWARE SCHEDULE IN MANNER INDICATED
BELOW. COORDINATE HARDWARE WITH DOORS. FRAMES AND RELATED WORK TO
ENSURE PROPER SIZE. THICKNESS, HMO, FUNCTION AND FINISH OF HARDWARE. FINAL
HARDWARE SCHEDULE CONTENT TO INCLUDE THE FOLLOWING INFORMATION:
A. TYPE, STYLE. FUNCTION, SIZE AND FINISH OF EACH HARDWARE ITEM.
B. NAME AND MANUFACTURER OF EACH ITEM.
C. FASTENINGS AND OTHER PERTINENT INFORMATION.
CIE ON OF HARDWARE SET CROSS-REFERENCED TO INDICATIONS ON DRAWINGS
BOTH ON FLOOR PLANS AND IN DOOR AND FRAME SCHEDULE.
E. EXPLANATION OF ALL ABBREVIATIONS, SYMBOLS, CODES, ETC. CONTAINED IN
SCHEDULE.
F. MOUNTINO LOCATIONS FOR HARDWARE.
G. DOOR AND FRAME SIZES AND MATERIALS.
H. KEYING INFORMATION.
6. TEMPLATES: FURNISH HARDWARE TEMPLATES TO EACH FABRICATOR OF DOORS,
FRAMES AIRD OTHER WORK TO BE FACTORY -PREPARED FOR THE INSTALLATION OF
HARDWARE. UPON REQUEST, CHECK SHOP DRAWINGS OF SUCH OTHER WORK, TO
CONFIRM THAT ADEQUATE PROVISIONS ARE MADE FOR PROPER LOCATION AND
INSTALLATION OF HARDWARE.
7. MOUNT HARDWARE UNITS AT HEIGHTS INDICATED IN "RECOMMENDED LOCATIONS FOR
BUILDERS HARDWARE FOR STANDARD STEEL DOORS AND FRAMES" BY THE DOOR AND
HARDWARE INSTITUTE, EXCEPT AS SPECIFICALLY INDICATED OR REQUIRED TO
COMPLY WITH GOVERNING REGULATIONS, AIRD EXCEPT AS OTHERWISE INDICATED ON
THE DRAWINGS.
8� INSTALL EACH HARDWARE ITEM IN COMPLIANCE WITH THE MANUFACTURER'S
INSTRUCTIONS AND RECOMMENDATIONS. WHEREVER CUTTING AND FITTING IS
REQUIRED TO INSTALL HARDWARE ONTO OR INTO SURFACES WHICH ARE LATER TO
BE PAINTED OR FINISHED IN MOTHER WAY. COORDINATE REMOVAL, STORAGE AND
REINSTALLATION OR APPLICATION OF SURFACE PROTECTIONS WITH FINISHING WORK.
00 NOT INSTALL SURFACE -MOUNTED ITEMS UNTIL FINISHES HAVE 13EEN COMPLETED
ON THE SUBSTRATE.
9. SET UNITS LEVEL, PLUMB AND TRUE TO LINE AND LOCATION. ADJUST AND
REINFORCE THE ATTACHMENT SUBSTRATE AS NECESSARY FOR PROPER
INSTALLATION AND OPERATION.
10. ADJUST AND CHECK EACH OPERATING ITEM OF HARDWARE AND EACH DOOR, TO
ENSURE PROPER OPERATION OR FUNCTION OF EVERY UNIT. REPLACE UNITS WHICH
CANNOT BE ADJUSTED TO OPERATE FREELY AND SMOOTHLY AS INTENDED FOR THE
APPLICATION MADE.
11, INSTRUCT OWNER'S PERSONNEL IN PROPER ADJUSTMENT AND MAINTENANCE OF
HARDWARE AND HARDWARE FINISHES, DURING THE FINAL ADJUSTMENT OF HARDWARE.
08 80 00 GLASS & GLAZING
1. THE GENERAL CONTRACTOR IS TO PROVIDE GLASS AND GLAZING THAT HAS BEEN
FABRICATED AND INSTALLED TO WITHSTAND NORMAL THERMAL MOVEMENT AND
IMPACT LOADING WITHOUT FAILURE INCLUDING LOSS OR BREAKAGE OF GLASS OR
FAILURE OF GASKETS AND SEALANTS. GASKETS AND SEALANTS TO REMAIN
AIR -TIGHT AND WATERTIGHT.
2. COMPLY WITH RECOMMENDATIONS AND DEFINITIONS OF OGLASS ASSOCIATION OF
NORTH AMERICA' GLAZING MANUAL AND SEALANT MANUAL EXCEPT WHERE MORE
STRINGENT REQUIREMENTS ARE INDICATED OR REQUIRED.
3. WHERE SAFETY OR TEMPERED GLASS IS INDICATED PROVIDE TYPE OF PRODUCTS
WHICH COMPLY W/ ANSI Z97.1 AND TESTING REQUIREMENTS OF 16 OFF PART 1201
FOR CATEGORY 11 MATERIAL, OR WHICH COMPLY WITH GOVERNING REGULATIONS AND
CODES. WHICHEVER IS K40RE STRINGENT.
4. TO ENSURE CONSISTENT QUALITY OF APPEARANCE AND PERFORMANCE, PROVIDE
MATERIALS PRODUCED BY A SINGLE MANUFACTURER FOR EACH KIND AND CONDITION
OF GLASS INDICATED.
5. INSTALL ALL GLAZING, FRAMES, GASKETS AND SEALANTS PER MANUFACTURER'S
SPECIFICATIONS.
6. SAMPLES: SUBMIT, FOR VERIFICATION PURPOSES. 12" SQUARE SAMPLES OF EACH
TYPE OF GLASS INDICATED.
7. REQUIRE GLAZIER TO INSPECT WORK OF FRAMING ERECTOR FOR COMPLIANCE WITH
MANUFACTURING AND INSTALLATION TOLERANCES, INCLUDING THOSE FOR SIZE.
SQUARENESS. OFFSETS AT CORNERS; FOR PRESENCE AND FUNCTIONING OF WEEP
SYSTEM; FOR EXISTENCE OF MINIMUM REQUIRED FACE OR EDGE CLEARANCES; AND
FOR EFFECTIVE SEALING OF JOINERY. OBTAIN GLAZIER'S WRITTEN REPORT LISTING
CONDITIONS DETRIMENTAL TO PERFORMANCE OF GLAZING WORK. DO NOT ALLOW
GLAZING WORK TO PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN
CORRECTED.
09 29 00 GYPSUM BOARD
1. FASTENERS: FASTENERS SHALL BE DRYWALL SCREWS OF PROPER SIZE AND TYPE
PER MANUFACTURERS RECOMMENDATIONS.
2. ALL GYPSUM BOARD AT OUTSIDE CORNERS SHALL RECEIVE mUSG* DUR-A-BEAD 001.
USE mUSGm 20B METAL TRIM WHERE HEADS ARE EXPOSED. ALL JOINTS SHALL
HAVE *USG' PERF-A-TAPE JOINT SYSTEM. ALL SURFACES TO BE TAPED, SPACKLED
AND SANDED TO A CONDITION TO ACCEPT ALL NEW FINISFES.
3. THE GENERAL CONTRACTOR SHALL FURNISH AND INSTALL ALL GYPSUM BOARD AND
SYSTEMS COMPLETE WITH PARTITION FRAMING, CEIL. SUSPENSION SYSTEMS AND
RELATED ACCESSORIES, PARTS, MATERIALS, ETC. AS SHOWN ON DRAWINGS AND AS
SPECIFIED. INSTALL ALL MATERIALS PER MANUFACTURERS SPECIFICATIONS AND
RECOMMENDATIONS.
4. AT CURVED GYPSUM WALL BOARD SURFACES, FINISHED FACE OF CURVE IS TO BE
ACHIEVED BY FASTENING TO 2 LAYERS OF 1/4' GYPSUM WALL BOARD TO STUDS
SPECIFIED ON THE DRAWINGS WHICH ME TO BE SPACED AT 6* ON CENTER FOR
ENTIRE LENGTH OF THE CURVE.
5. PROVIDE FIRE-RES16TANCE-RATED ASSEMBLIES IDENTICAL TO THE DESIGN
DESIGNATIONS IN U.L. 'FIRE RE516TMCE DIRECTORY' OR IN LISTING OF OTHER
TESTING AND AGENCIES ACCEPTABLE TO AUTHORITIES HAVING JURISDICTION.
6� SINGLE SOURCE RESPONSIBILITY: OBTAIN EACH TYPE OF GYPSUM BOARD AND
RELATED JOINT TREATMENT MATERIALS FROM A SINGLE MANUFACTURER
T GENERAL: PROVIDE COMPONENTS WHICH COMPLY WITH ASTM C 754 FOR MATERIALS
AND SIZES, UNLESS OTHERWISE INDICATED.
8. GENERAL: PROVIDE GYPSUM BOARD OF TYPES INDICATED IN MAXIMUM LENGTHS
AVAILABLE TO MINIMIZE END -TO -ENO JOINTS.
9. GYPSUM WALLBOARD TO COMPLY WITH ASTM C 36. GYPSUM BACKING BOARD FOR
MULTI -LAYER APPLICATIONS TO COMPLY WITH ASTM C 442. WATER-RESISTANT
GYPSUM BACKING BOARD IS TO COMPLY WITH ASTM C 630.
10. GENERAL PROVIDE AUXILIARY MATERIALS FOR GYPSUM DRYWALL CONSTRUCTION
WHICH EOMPLY WITH REFERENCED STANDARDS AND THE RECOMMENDATIONS OF THE
MANUFACTURER OF THE GYPSUM BOARD.
1.
2.
3.
4.
5.
0
7.
S.
09 51 00 ACOUSTICAL CEILINGS
THE GENERAL CONTRACTOR SHALL MODIFY THE EXIST. SUSPENDED ACOUSTICAL
PANEL CEILING INCLUDING THE SUSPENSION SYSTEM AND RELATED ACCESSORIES AS
INDICATED ON THE DRAWINGS AND AS SPECIFIED HEREIN.
SUSPENSION SYSTEMS SHALL HE ADEQUATE TO SUPPORT LIGHTING FIXTURES.
CEILING GRILLES AND DIFFUSERS AND OTHER NORMAL ACCESSORIES.
FINISHED CEILING SHALL BE WATER LEVEL WITH ALL JOINTS SNUG AND SQUARE.
GENERAL CONTRACTOR TO REPLACE ANY ACOUSTICAL CEILING TILES DAMAGED AS A
DIRECT OR INDIRECT RESULT OF HIS WORK.
SUSPEND CEILING HANGERS FROM PERMISSIBLE BUILDING STRUCTURAL MEMBERS AND
AS FOLLOWS:
A. INSTALL HANGERS PLUMB AND FREE FROM CONTACT WITH INSULATION OR
OTHER OBJECTS ABOVE CEILING THAT ARE NOT PART OF THE SUPPORTING
STRUCTURE OR CEILING SUSPENSION SYSTEM. SPLAY HANGERS ONLY WHERE
REQUIRED TO MISS OBSTRUCTIONS AND OFFSET RESULTING HORIZONTAL
FORCES BY BRACING, COUNTERSPILAYING, OR OTHER EQUALLY EFFECTIVE MEANS.
B. WHERE WIDTH OF DUCTS AND OTHER CONSTRUCTION ABOVE THE CEILING
PRODUCES HANGER SPACING THAT INTERFERE WITH THE LOCATION OF
HANGERS AT SPACINGS REQUIRED TO SUPPORT STANDARD SUSPENSION SYSTEM
MEMBERS, INSTALL SUPPLEMENTAL SUSPENSION MEMBERS AIRD HANGERS IN FORM
OF TRAPEZES OR EQUIVALENT DEVICES. SIZE SUPPLEMENTAL 6USPEN61ON
MEMBERS MO HANGERS TO SUPPORT CEILING LOADS WITHIN PERFORMANCE
LIMITS ESTABLISHED By "STANDARD FOR INSTALLATION OF CEILING SUSPENSION
SYSTEMS: COMPLY WITH ASTM C 636*, C.I.S.C.A. 'CEILING SYSTEMS HI
AND PER MANUFACTURER'$ INSTRUCTIONS.
C. SECURE WIRE HANGERS By LOOPING AND WIRE -TYING, EITHER DIRECTLY TO
STRUCTURES OR TO INSERT, EYESCREWS, OR OTHER DEVICES THAT ARE
SECURE AND APPROPRIATE FOR SUBSTRATE, AND IN A MANNER THAT WILL NOT
CAUSE THEM TO DETERIORATE OR OTHERWISE FAIL DUE TO AGE, CORROSION.
OR ELEVATED TEMPERATURES.
D. SECURE FLAT, ANGLE, CHANNEL, AND ROD HANGERS TO STRUCTURE, INCLUDING
INTERMEDIATE FRAMING MEMBERS, BY ATTACHING TO INSERTS, EYE -SCREWS, OR
OTHER DEVICES THAT ARE SECURE AND APPROPRIATE FOR STRUCTURE TO
WHICH HANGERS ARE ATTACHED AS WELL AS FOR TYPE OF HANGER INVOLVED,
AND IN A MANNER THAT WILL NOT CAUSE THEM TO DETERIORATE OR FAIL DUE
TO AGE, CORROSION, OR ELEVATED TEMPERATURES.
E. SPACE HANGERS NOT MORE THAN 4�0* D.C. &ONG EACH MEMBER SUPPORTED
DIRECTLY FROM HANGERS, UNLESS OTHERWISE SHOWN, AND PROVIDE HANGERS
NOT MORE THAN 8 INCHES FROM ENDS OF EACH MEMBER.
INSTALL ACOUSTICAL PANELS IN COORDINATION WITH SUSPENSION SYSTEM, WITH
EDGES CONCEALED BY SUPPORT OF SUSPENSION MEMBERS. SCRIBE AND CUT
PANELS TO FIT ACCURATELY AT BORDER$ AND AT PENETRATIONS.
CLEAN EXPOSED SURFACES OF ACOUSTICAL CEILING, INCLUDING TRIM AIRD
SUSPENSION MEMBERS. COMPLY WITH MANUFACTURER'S INSTRUCTIONS FOR CLEANING
AND TOUCH-UP OF MINOR FINISH DAMAGE. REMOVE AND REPLACE WORK THAT
CANNOT BE SUCCESSFULLY CLEANED AND REPAIRED TO PERMANENTLY ELIMINATE
EVIDENCE OF DAMAGE.
INSTALL HOLD-DOWN CLIPS FOR ACOUSTICAL CEILING PANELS IN THE IDFS. PER
CEILING MANUFACTURER'S SPECIFICATIONS.
09 60 00 FLOORCOVERING
1. THE GENERAL CONTRACTOR SHALL INSTALL ALL FLOOR COVERINI AS INDICATED
ON THE FINISH SCHEDULE AND AS NOTED ON THE DRAWINGS FOR LOCATION AND
EXTENT.
2. SHOP DRAWINGS: SUBMIT SHOP DRAWINGS SHOWING CARPET LAYOUT AND SEAMING
DIAGRAMS, CLEARLY INDICATING CARPET DIRECTION, AND TYPES OF EDGE STRIPS.
INDICATE COLUMNS, DOORWAYS, ENCLOSING WALLS/ PARTITIONS, BUILT-IN CABINETS.
AND LOCATIONS WHERE CUTOUTS ARE REQUIRED IN CARPET. SHOW INSTALLATION
DETAILS AT ANY SPECIAL CONDITIONS.
3. SAMPLES FOR VERIFICATION PURPOSES: SUBMIT THE FOLLOWING: 180 SQUARE
SAMPLES OF EACH TYPE OF CARPET MATERIAL REQUIRED, 6w SQUARE SAMPLES OF
EACH TYPE OF CARPET CUSHION, AND 121 LONG SAMPLES OF EACH TYPE EXPOSED
EDGE STRIPPING AND ACCESSORY ITEM. SUBMIT 12a SQUARE SAMPLES OF OTHER
TYPES OF FLOORCOVERING (V.C.T., ETC.)
4. GENERAL CONTRACTOR TO INSPECT CARPET PRIOR TO INSTALLATION FOR ANY
DEFECTS.
5. COMPLY WITH INSTRUCTIONS AND RECOMMENDATIONS OF MANUFACTURER FOR
SPECIAL DELIVERY, STORAGE, AND HANDLING REQUIREMENTS FOR EACH TYPE OF
FLOORCOVERINGE
6. SEQUENCE CARPET INSTALLATION WITH OTHER WORK TO MINIMIZE POSSIBILITY OF
DAMAGE AND SOILING DURING REMAINDER OF CONSTRUCTION PERIOD.
7. COMPLY WITH MANUFACTURERS RECOMMENDATIONS FOR SEAM LOCATIONS AND
DIRECTION OF CARPET; MAINTAIN UNIFORMITY OF CARPET DIRECTION AND LAY OF
PILE. FOLLOW SEWING DIAGRAM AS SUBMITTED AND APPROVED. AT DOORS, CENTER
BEAMS UNDER DOORS; 00 NOT PLACE SEAMS IN TRAFFIC DIRECTION AT DOORWAY.
DURING INSTALLATION, ALL PATTERNED CARPET IS TO BE SEAMED SO THAT, WHERE
THE CARPET IS THE SAME ON BOTH SIDES OF THE SEAM, THE ALIGNMENT AND
REPEAT OF THE PATTERN ARE MAINTAINED THROUGH THE SEW.
B. ADHESIVES: PROVIDE MANUFACTURER'S RECOMMENDED ADHESIVES, PRODUCED
EXPRESSLY FOR USE W/ SELECTED FLOORCOVERING5 ON SUBSTRATE A$ SHOWN
ON DRAWINGS. PROVIDE MATERIALS WHICH ARE MILDEW RESISTANT.
9. EXAMINE SUBSTRATES FOR MOISTURE CONTENT. ELIMINATE ANY MOISTURE PRESENT.
CLEAR AWAY MY AND ALL DEBRIS AND SCRAPE UP CEMENTITIOUS DEPOSITS FROM
SURFACES TO RECEIVE CARPETING; VACUUM CLEAN IMMEDIATELY BEFORE
INSTALLATION. CHECK CONCRETE SURFACES TO ENSURE NO DUSTING THROUGH
INSTALLED CARPET; APPLY SEALER WHERE REQUIRED TO PREVENT DUSTING.
10. MAINTENANCE INSTRUCTIONS: SUBMIT MANUFACTURER'S PRINTED INSTRUCTIONS FOR
MAINTENANCE OF INSTALLED WORK, INCLUDING METHODS AND FREQUENCY
RECOMMENDED FOR MAINTAINING OPTIMUM CONDITION UNDER ANTICIPATED TRAFFIC
AND USE CONDITIONS. INCLUDE PRECAUTIONS AGAINST MATERIALS AND METHODS
WHICH MAY BE DETRIMENTAL TO FINISHES AND PERFORMANCE.
11. EXPANSION JOINTS: DO NOT BRIDGE BUILDING EXPANSION JOINTS WITH CONTINUOUS
CARPETING OR OTHER FLOORCOVERING; PROVIDE FOR MOVEMENT.
12. REMOVE AND DISPOSE OF DEBRIS AND UNUSABLE SCRAPS. VACUUM CARPET USING
COMMERCIAL MACHINE WITH FACE -BEATER ELEMENT.
15. PROVIDE PROTECTIVE METHODS AND MATERIALS NEEDED TO ENSURE THAT
FLOORCOVERINGS WILL BE WITHOUT DETERIORATION OR DAMAGE AT TIME OF THE
PROJECT'S COMPLETION.
09 68 15 CARPET - LIBERTY MUTUAL GUIDE SPECIFICATION
1.1 SCOPE
A. WORK INCLUDED: FURNISH AND INSTALL ALL MATERIALS, TOOLS AND LABOR REQUIRED
TO COMPLETE THE WORK OF THIS SECTION. SUCH WORK INCLUDES BUT IS NOT
LIMITED TO THE FOLLOWING:
1. RECEIVING, STORING AND DELIVERY TO THE JOB SITE OF OWNER SUPPLIED
CARPET.
2. SUPPLY ADHESIVE CEMENT, LABOR, CUTTING OF SELVAGES, GLUING OF CARPET
EDGES AND METAL STRIPS, THRESHOLDS, AND OTHER ACCESSORIES REQUIRED TO
PROPERLY INSTALL CARPET IN A WORKMAN LIKE MANNER.
5. PREPARATION OF SUBFLOOR. NEW AND EXISTING
1.2 RELATED WORK IN OTHER SECTIONS
A. THE FOLLOWING ITEMS OF ASSOCIATED WORK ARE INCLUDED IN OTHER
SECTIONS OF THESE SPECIFICATIONS:
I FURNISH AND INSTALL RESILIENT FLOORING AND BASE.
i. CARPET TO 13E INSTALLED BY AN INSTALLATION SERVICE ENTITY APPROVED BY
SHAW CONTRACT FLOORING.
3. INSTALLATION CREWS TO BE CERTIFIED BY THE MOHAWK GROUP, CHATSWORTH,
OAF.
4. ALL ADHESIVES USED SHALL BE GREEN LABEL.
2.0 INSTALLATION
A TEE CONTRACTOR SHALL BE RESPONSIBLE FOR PREPARING ALL NEW AND EXISTING
SUBFLOORS TO RECEIVE CARPETING, WHERE SPECIFIED. LEVELING MATERIALS,
SANDING/GRINDING, ETC. SHALL BE CONDUCTED TO SUBSTRATE AS REQUIRED FOR A
NEAT, SMOOTH FINISHED INSTALLATIOSL
B. ALL MATERIAL SHALL BE INSTALLED BY SKILLED WORKMEN UNDER PROPER
SUPERVISION. PRIOR TO INSTALLATION, ALL FLOOR IRREGULARITIES SHALL BE REPAIRED BY
THE CONTRACTOR AND THE FLOOR SHALL BE THOROUGHLY CLEANED OF ALL DIRT,
GRIME AND DUST REMOVED.
C. AFTER THE INSTALLATION 16 COMPLETE, CLEM UP ALL DIRT AND DEBRIS AND CLEM
CARPET OF ALL SPOTS WITH PROPER SPOT REMOVER. REMOVE ALL LOOSE THREADS
WITH SHARP SUCCORS. THEN CLEAN WITH BROOM OR VACUUM CLEANER. THE OWNER
SHALL VIEW ALL CARPET SCRAPS AND RETAIN ANY HE CHOOSM FOR FUTURE REPAIR
BEFORE THEY ME REMOVED FROM THE JOB SITE. THE ENTIRE INSTALLATION SHALL SE
LEFT CLEM AND IN A CONDITION APPROVED BY THE OWNER.
0. ALL CROSS SEAMS WILL BE HELD TO AN ABSOLUTE MINIMUM.
E. SEAMS AT DOORWAYS MUST BE PARALLEL TO THE DOOR AND LIE DIRECTLY
UNDERNEATH THE DOOR.
F. PERPENDICULAR SEAMS AT DOORWAYS WILL NOT BE PERMITTED.
4.0 GUARANTEES
A THE CARPET INSTALLER SHALL BE REQUIRED TO RE -LAY ANY CARPET THAT DOES
NOT PROVIDE AN ATTRACTIVE WRINKLE -FREE APPEARANCE, THE INSTALLER SHALL BE
REQUIRED TO RETURN TO RE -STRETCH OR CORRECT ANY CONDITION DUE TO FAULTY
INSTALLATION WITHIN ONE YEAR OF THE ORIGINAL INSTALLATION, WITHOUT ANY COST
TO THE OWNER.
09 30 00 FLOOR TILE
09 30 00 FLOOR TILE (CONTINUE)
PAINT - LIBERTY MUTUAL GUIDE SPECIFICATION (CONTINUED)
9.
GROUT MATERIALS: CHEMICAL -RESISTANT EPDXY GROUT: ANSI A118.3, COLOR AS
5. INTERIOR SURFACES - PAINTED
INDICATED. PROVIDE PRODUCT CAPABLE OF RESISTING CONTINUOUS AND
INTERMITTENT EXPOSURE TO TEMPERATURES OF UP TO 140 DEG F (60 DEG C) AND
NOTE COATINGS LISTED ARE NOT DESIGNED TO BE USED IN AREAS REGULARLY
212 DEG F (100 DEG C), RESPECTIVELY, AS CERTIFIED BY MORTAR MANUFACTURER
EXPOSED TO WATER OR HARSH CHEMICALS. THESE ENVIRONMENTS MAY REQUIRE
FOR INTENDED USE.
SPECIAL COATINGS. PLEASE CONTACT YOUR BENJAMIN MOORE REPRESENTATIVE FOR
RECOMMENDATIONS.
10,
MIX MORTARS AND GROUTS TO COMPLY WITH REQUIREMENTS OF REFERENCED
STANDARDS AND MANUFACTURERS INCLUDING THOSE FOR ACCURATE PROPORTIONING
ALL REGAL SELECT PRODUCTS MUST BE APPLIED AT 400-450 SQ. FT. PER GALLON TO
OF MATERIALS, WATER, OR ADDITIVE CONTENT; TYPE OF MIXING EQUIPMENT,
ACHIEVE A MINIMUM OF 5.0 MILS WET AND 1.7 MILS DRY. A WET MIL GAUGE SHOULD BE
SELECTION OF MIXER SPEEDS, MIXING CONTAINERS, MIXING TIME, AND OTHER
USED TO ENSURE PROPER APPLICATION.
PROCEDURES NEEDED TO PRODUCE MORTARS AND GROUTS OF UNIFORM QUALITY
JOBS SHOULD BE BID FOR TWO (2) COATS OF THE REGAL SELECT PRODUCT.
WITH OPTIMUM PERFORMANCE CHARACTERISTICS FOR APPLICATION INDICATED.
11.
EXAMINE SUBSTRATES AND AREAS WHERE TILE WILL BE INSTALLED. WITH INSTALLER
6. ORDERING BENJAMIN MOORE PAINT
PRESENT, FOR COMPLIANCE WITH REQUIREMENTS FOR INSTALLATION TOLERANCES
AND OTHER CONDITIONS AFFECTING PERFORMANCE OF INSTALLED TILE. VERIFY THAT
BIDDERS ARE INSTRUCTED TO BUDGET $36.99 PER GALLON PLUS TAX FOR BENJAMIN
SUBSTRATES FOR SETTING TILE ARE FIRM, DRY, CLEAN, AND FREE FROM OIL OR
MOORE REGAL SELECT PRODUCTS. IF AWARDED THE CONTRACT, THE PAINT
WAXY FILMS, CURING COMPOUNDS AND WITHIN FLATNESS TOLERANCES REQUIRED BY
CONTRACTOR NEEDS TO PURCHASE THE BEN MOORE REGAL SELECT PAINT THROUGH
REFERENCED ANSI A108 SERIES OF TILE INSTALLATION STANDARDS FOR
THE BENJAMIN MOORE NATIONAL ACCOUNTS PROGRAM BY USING THE FOLLOWING
INSTALLATIONS INDICATED. VERIFY THAT INSTALLATION OF GROUNDS, ANCHORS,
PROCEDURE:
RECESSED FRAMES, ELECTRICAL AND MECHANICAL UNITS OF WORK, AND SIMILAR
, ORDERS MUST BE PLACED THROUGH THE BENJAMIN MOORE DIRECT ORDER LINE AT
ITEMS LOCATED IN OR BEHIND TILE HAS BEEN COMPLETED BEFORE INSTALLING
1-877-623-8484. NATIONAL ACCOUNT I 182 (LIBERTY MUTUAL) NEEDS TO BE
TILENERIFY THAT JOINTS AND CRACKS IN TILE SUBSTRATES ARE COORDINATED
WITH TILE JOINT LOCATIONS; IF NOT COORDINATED, ADJUST LATTER IN
SPECIFIED.
CONSULTATION WITH ARCHITECT. DO NOT PROCEED WITH INSTALLATION UNTIL
, THE PAINT CONTRACTOR CAN SPECIFY A PREFERRED LOCAL PARTICIPATING
UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED.
BENJAMIN MOORE INDEPENDENT RETAILER, OR ONE CAN BE SUGGESTED BY BENJAMIN
MOORE.
12.
EXTEND TILE WORK INTO RECESSES AND UNDER OR BEHIND EQUIPMENT AND
, ALL BILLING WILL BE DONE THROUGH THE INDIVIDUAL LOCAL PARTICIPATING
FIXTURES TO FORM A COMPLETE COVERING WITHOUT INTERRUPTIONS EXCEPT AS
BENJAMIN MOORE INDEPENDENT RETAILER.
OTHERWISE SHOWN. TERMINATE WORK NEATLY AT OBSTRUCTIONS, EDGES, AND
, AT NO TIME SHOULD A PAINT CONTRACTOR PAY, OR INVOICE LIBERTY MUTUAL,
CORNERS WITHOUT DISRUPTING PATTERN OR JOINT ALIGNMENTS.
MORE THAN THE NATIONAL ACCOUNT PRICING OF SI A GALLON PLUS TAX.
- ANY QUESTIONS OR ISSUES WITH THE NATIONAL ACCOUNT ORDERING PROCESS
13.
ACCURATELY FORM INTERSECTIONS AND RETURNS. PERFORM CUTTING AND DRILLING
CAN BE ADDRESSED TO JIM GORMAN, BENJAMIN MOORE NATIONAL ACCOUNT
OF TILE WITHOUT MARRING VISIBLE SURFACES. CAREFULLY GRIND CUT EDGES OF
REPRESENTATIVE, 201-949-6354, JAMESS.GORMANOBENJAMINMOORE.COM
TILE ABUTTING TRIM, FINISH, OR BUILT-IN ITEMS FOR STRAIGHT ALIGNED JOINTS. FIT
TILE CLOSELY TO ELECTRICAL OUTLETS, PIPING, FIXTURES, AND OTHER
PENETRATIONS 60 THAT PLATES, COLLARS, OR COVERS OVERLAP TILE.
10 26 00 WALL & CORNER GUARDS
14.
JOINTING PATTERN: UNLESS OTHERWISE SHOWN, LAY TILE IN GRID PATTERN. ALIGN
JOINTS WHEN ADJOINING TILES ON FLOOR. BASE. WALLS, AND TRIM ARE SAME SIZE.
1. GENERAL: SUBMIT PRODUCT DATA AND DETAILED SPECIFICATIONS FOR EACH
LAY OUT TILE WORK AND CENTER TILE FIELDS IN BOTH DIRECTIONS IN EACH
SYSTEM COMPONENT AND INSTALLATION ACCESSORY REQUIRED. INCLUDING
SPACE OR ON EACH WALL AREA ADJUST TO MINIMIZE TILE CUTTING. PROVIDE
INSTALLATION METHODS FOR EACH TYPE OF SUBSTRATE, AND SUBMIT SHOP
UNIFORM JOINT WIDTHS UNLESS OTHERWISE SHOWN.
DRAWINGS SHOWING LOCATIONS, EXTENT AND INSTALLATION DETAILS OF BUMPER
GUARDS, CORNER GUARDS AND OTHER PROTECTION SYSTEMS. SHOW METHODS OF
15.
SUPPLY AND INSTALL A COLORED GROUT TO MATCH THE SPECIFIED TILE. GENERAL
ATTACHMENT TO ADJOINING CONSTRUCTION
CONTRACTOR IS TO PROVIDE THE ARCHITECT THE FULL RANGE OF MFRS STANDARD
2. SAMPLES FOR VERIFICATION PURPOSES: SUBMIT 12 INCH LONG SAMPLE OF EACH
COLORED GROUTS TO SELECT FROM.
MODEL SPECIFIED INCLUDING END CAP AND MOUNTING HARDWARE AS PROPOSED FOR
16.
INSTALLATION, GENERAL:
THIS WORK, FOR VERIFICATION OF COLOR, TEXTURE, PATTERN AND END CAP
ATTACHMENT/ALIGNMENT. SUBMIT PRODUCT TEST REPORTS FROM A QUI
A. ANSI TILE INSTALLATION STANDARDS: COMPLY WITH PARTS OF ANSI AIDS SERIES
INDEPENDENT TESTING LABORATORY SHOWING COMPLIANCE OF EACH COMPONENT
OF TILE INSTALLATION STANDARDS IN �SPECIFICATIONS FOR INSTALLATION OF
WITH REQUIREMENTS INDICATED.
CERAMIC TILEw THAT APPLY TO TYPES OF SETTING AND GROUTING MATERIALS
3. INSTALLER QUALIFICATIONS: ENGAGE AN INSTALLER WHO HAS NOT LESS THAN 3
AND TO METHODS INDICATED IN CERAMIC TILE INSTALLATION SCHEDULES.
YEARS EXPERIENCE IN INSTALLATION OF SYSTEMS SIMILAR IN COMPLEXITY TO
B. TCA INSTALLATION GUIDELINES: TCA'S "HANDBOOK FOR CERAMIC TILE
THOSE REQUIRED FOR THIS PROJECT. MANUFACTURER'S QUALIFICATIONS: NOT
LESS THAN 5 YEARS EXPERIENCE IN THE PRODUCTION OF SPECIFIED PRODUCTS
INSTALLATION.' COMPLY WITH TCA INSTALLATION METHODS INDICATED IN
AND A RECORD OF SUCCESSFUL IN-SERVICE PERFORMANCE.
CERAMIC TILE INSTALLATION SCHEDULES.
4. CODE COMPLIANCE: ASSEMBLIES SHOULD CONFORM TO ALL APPLICABLE CODES
C. GROUT TILE TO COMPLY WITH THE REQUIREMENTS OF THE FOLLOWING TILE
INCLUDING UBC, SBCC1, BOCA, OSHA, LIFE SAFETY. OSIPPD AND ADA.
INSTALLATION STANDARDS:
5. FIRE PERFORMANCE CHARACTERISTICS: PROVIDE WALL PROTECTION SYSTEM
CJ. FOR CERAMIC TILE GROUTS (SAISO-PORTLAND CEMENT, DRY-6ET, COMMERCIAL
COMPONENTS WITH A UL LABEL INDICATING THAT THEY ARE IDENTICAL TO THOSE
PORTLAND CEMENT, AND LATEX-PORTLAND CEMENT GROUTS), COMPLY WITH
TESTED IN ACCORDANCE WITH ASTMI FOR CLASS I CHARACTERISTICS
ANSI AIOBAO
LISTED BELOW:
1. FLAME SPREAD: 25 OR LESS
C.2. FOR CHEMICAL -RESISTANT EPDXY GROUTS, COMPLY WITH ANSI A108.6
2. SMOKE DEVELOPED: 450 OR LESS
C.3. FOR CHEMICAL -RESISTANT FURAN GROUTS. COMPLY WITH ANSI MOBS
6. IMPACT STRENGTH: PROVIDE ASSEMBLED WALL PROTECTION UNITS THAT HAVE
BEEN TESTED IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF ASTM
F476-76.
09 91 23 PAINTING
7. 7. COLOR MATCH: PROVIDE WALL PROTECTION COMPONENTS THAT ARE COLOR
1. THE GENERAL CONTRACTOR IS RESPONSIBLE TO VISIT AND INSPECT THE SPACE
PRIOR TO T14E APPLICATION OF ANY PAINT OR FINISHING MATERIAL. IF ANY NEW
OR EXISTING SURFACE TO BE FINISHED CANNOT BE PUT IN PROPER CONDITION BY
CUSTOMARY CLEANING, SANDING ME PUTTYING OPERATIONS. THE GENERAL
CONTRACTOR SHALL RECTIFY THE CONDITION BEFORE THE APPLICATION OF ANY
FINISH.
2. THE INTENT IS TO PROVIDE A FINISH TO ALL PARTS OF THE PROJECT IN A
MANNER DEEMED SATISFACTORY BY THE OWNER, WHETHER NOTED HEREIN OR NOT,
COVER ALL SURFACES THOROUGHLY. IF THE NUMBER OF COATS SPECIFIED DOES
NOT ACCOMPLISH THE INTENT, THEN APPLY ADDITIONAL COATS OF SPECIFIED
MATERIAL TO GIVE SATISFACTORY COVERAGE. SEE THE FINISH SCHEDULE.
3. STAINLESS STEEL. �UMINUIM, CHROME PLATED SURFACES, AND ALL OTHER BRIGHT
METAL FINISHES SHALL NOT BE PAINTED UNLESS NOTED OTHERWISE.
4. USE ONLY THE PAINT AND THE RELATED MATERIALS OF THE MANUFACTURER'S
SPECIFIED. SUBMIT SAMPLES FOR THE ARCIPITECT'S APPROVAL.
5. ALL PAINTED SURFACES SHALL BE PREPARED IN STRICT ACCORDANCE WITH
MANUFACTURER'S SPECIFICATIONS (ESPECIALLY IN REGARD TO THE PRIMING EXISTING
SURFACES).
6. PAINTED GYPSUM BOARD TO RECEIVE ONE COAT LATEX PRIMER AND TWO COATS
OF SPECIFIED PAINT. TINT PRIMER TO APPROXIMATE SHADE OF THE FINAL COAT.
TOUCH UP ALL SUCTION SPOTS OR HOT SPOTS AFTER APPLICATION OF FIRST
COAT AND BEFORE APPLYING SECOND COAT, TO PRODUCE AN EVEN RESULT IN
THE FINISH COAT, DRY ALL COATS THOROUGHLY BEFORE APPLYING SUCCESSIVE
COATS. FOLLOW MANUFACTURER'S RECOMMENDATIONS FOR RECOAT TIME.
7. WASH ALL METAL SURFACES WITH MINERAL SPIRITS TO REMOVE ALL DIRT AND
GREASE BEFORE APPLYING FINISH. WHERE RUST ANI SCALE IS PRESENT, WIRE
BRUSH OR SAND CLEM BEFORE APPLYING FINISH.
8. PUTTY ALL NAIL HOLES, COUNTERSUNK SCREWS, BOLTS, CRACKS, ETC. BEFORE
APPLYING FINISH.
9. SAND ALL WOOD SURFACES SMOOTH AND EVEN BEFORE APPLYING FINISH.
10. BEFORE STARTING THE FINISH WORK, REMOVE HARDWARE, ACCESSORIES, PLATES,
LIGHTING FIXTURES, AND SIMILAR ITEMS, OR PROVIDE AMPLE PROTECTION FOR SUCH
ITEMS.
11. PAINT ALL EXPOSED PIPING, ACCESS DOORS AND EQUIPMENT MOUNTING BOARDS
ETC. PAINT TO MATCH THE ADJACENT WORK UNLESS OTHERWISE NOTED.
12. SAND ENAMELED FINISHES APPLIED TO WOODS OR METAL BETWEEN COATS WITH
FINE SANDPAPER TO PRODUCE SMOOTH FINISH.
15. MAKE FINISH WORK UNIFORM AND SMOOTH, FREE OF RUNS, SAGS, DEFECTIVE
BRUSHING AND CLOGGING. MAKE EDGES OF PAINT ADJOINING OTHER MATERIALS OR
COLORS SHARP AND CLEAN WITHOUT OVERLAPPING.
14. FIELD PAINTING, EXCEPT TOUCH-UP. WILL NOT BE REQUIRED ON ITEMS SPECIFIED
TO BE COMPLETELY FINISHED AT FACTORY UNLESS SPECIFICALLY DESIGNATED.
GENERAL CONTRACTOR SHALL LEAVE SUFFICIENT MATERIAL FOR TOUCH UP OF
FINISHES.
15. THE GENERAL CONTRACTOR SHALL LEAVE WITH THE OWNER A MINIMUM OF ONE (3)
GALLONS OF EACH WALL PAINT USED ON THE PROJECT.
16. THE GENERAL CONTRACTOR SHALL REMOVE ALL PAINT RAGS, EMPTY CANS AND
WASTE FROM THE TENANT'S SPACE EACH DAY.
17. CLEANING AND TOUCHING -UP: IN ADDITION TO THE CLEANING REQUIRED IN THE *A.I.A.
GENERAL CONDITIONS' THE GENERAL CONTRACTOR SHALL UPON COMPLETION: (1)
REMOVE ALL PAINT AND/OR PASTE WHERE IT HAS SPILLED, SPLASHED OR
SPLATTERED (INCLUDING: FIXTURES, GLASS, HARDWARE, CARPETING, ETC.) (2)
TOUCH-UP AND RESTORE THE FINISH OF ANY ITEM MARRED OR DAMAGED DURING
FINISH OPERATIONS OR CLEAN-UP.
PAINT - LIBERTY MUTUAL GUIDE SPECIFICATION
THE PURPOSE OF THIS GUIDE SPECIFICATION IS TO PROVIDE A UNIFORM STANDARD
FOR SURFACE PREPARATION AND FINISHING OF INTERIOR SURFACES USING SPECIFIED
BENJAMIN MOORE PRODUCTS.
ANY QUESTIONS ABOUT THE CONTENT OR MEANING OF THIS SPECIFICATION SHALL BE
DIRECTED TO:
JIM GORMAN
NATIONAL ACCOUNT REPRESENTATIVE
BENJAMIN MOORE & COMPANY
1, SCOPE
THIS GUIDE SPECIFICATION COVERS TYPICALLY ENCOUNTERED SUBSTRATES ON LIBERTY
MUTUAL INTERIOR SURFACES. SURFACES OR CONDITIONS NOT COVERED HERE SHOULD
BE INSPECTED BY BENJAMIN MOORE PERSONNEL WHO WILL MAKE PROPER
RECOMMENDATIONS FOR PREPARATION AND COATING.
2. WORKMANSHIP
- SURFACES NOT TO BE COATED SHALL BE PROTECTED DURING APPLICATION OF
THE NEW COATINGS. PAINT MISPLACED ON THESE SURFACES SHALL BE CLEANED
AND REMOVED.
, WET PAINT SIGNS SHALL BE PLACED IN ORDER TO NOTIFY ALL PERSONS HAVING
BUSINESS IN OR ACCESS TO THE INTERIOR SPACES INVOLVED.
. APPLICATORS SHALL READ, UNDERSTAND, AND COMPLY WITH BENJAMIN MOORE A: CO.
PRODUCT LABELS AND PRODUCT DATA PAGES. IF QUESTIONS ARISE CONCERNING
THE USE OF THESE PRODUCTS CONTACT A BENJAMIN MOORE REPRESENTATIVE.
, IT IS VERY IMPORTANT THAT THE CONTRACTOR APPLYING THE PRODUCTS DO SO
AT THE MANUFACTURERS SUGGESTED SPREAD RATE FOR PROPER HIDE, FILM BUILD
AND PRODUCT PERFORMANCE. ANY SUBSTRATE CONCERNS THAT WILL AFFECT
OVERALL PRODUCT PERFORMANCE SHOULD BE BROUGHT FORWARD BEFORE
APPLICATION.
1. SUBMIT THE FOLLOWING:
A. PRODUCT DATA FOR EACH TYPE OF PRODUCT SPECIFIED
3. SURFACE PREPARATION
B. SHOP DRAWINGS INDICATING TILE PATTERNS. LOCATIONS AND WIDTHS OF
EXPANSION, CONTRACTION, CONTROL, AND ISOLATION JOINTS IN TILE
ALL SURFACES
SUBSTRATES AND FINISHED TILE SURFACES
C. LOCATE PRECISELY EACH JOINT AND CRACK IN TILE SUBSTRATES BY MEASURING,
, CLEM SURFACES TO BE COATED TO REMOVE ALL DIRT, CHALK. GREASE. OIL. OR
RECORD MEASUREMENTS ON SHOP DRAWINGS, AND COORDINATE THEM WITH TILE
OTHER CONTAMINATES, INCLUDING ANY EXISTING MILDEW AND MILDEW STAIN.
JOINT LOCATIONS, IN CONSULTATION WITH ARCHITECT
, ALL LOOSE OR PEELING PAINT SHALL BE REMOVED AND THE SURFACE AREA
D. TILE SAMPLES FOR VERIFICATION PURPOSES.
PROPERLY PREPARED PRIOR TO REFINISHING.
, GLOSSY SURFACES SHOULD BE DULLED FOR PROPER ADHESION OF ALL COATINGS.
2. SOURCE LIMITATIONS FOR TILE: OBTAIN EACH COLOR. GRADE, FINISH, TYPE,
, DAMAGED SURFACES (WOOD, METAL, MASONRY) SHALL BE REPAIRED OR REPLACED
COMPOSITION, AND VARIETY OF TILE FROM ONE SOURCE WITH RESOURCES TO
PROVIDE PRODUCTS FROM THE SAME PRODUCTION RUN FOR EACH CONTIGUOUS AREA
PRIOR TO THE APPLICATION OF MY COATING.
OF CONSISTENT QUALITY IN APPEARANCE AND PHYSICAL PROPERTIES WITHOUT
- LOOSE OR DAMAGED CAULKING MATERIAL SHALL BE REMOVED AND REPLACED.
DELAYING THE WORK.
, NEW MASONRY AND PLASTER SURFACES SHOULD BE ALLOWED TO CURE AND
COATED ACCORDING TO PRODUCT DATA SHEET$.
3. SOURCE LIMITATIONS FOR SETTING AND GROUTING MATERIALS: OBTAIN INGREDIENTS
- RUSTED SURFACES MUST BE PROPERLY TREATED AND COATED ACCORDING TO
OF A UNIFORM QUALITY FOR EACH MORTAR, ADHESIVE. AND GROUT COMPONENT
INDUSTRY STANDARD, PRIOR TO FINISH COATING.
FROM A SINGLE MANUFACTURER AND EACH AGGREGATE FROM ONE SOURCE OR
PRODUCER.
DIFFICULT SUBSTRATES
4. INSTALLER QUALIFICATIONS: ENGAGE AN EXPERIENCED INSTALLER WHO HAS
BENJAMIN MOORE OFFERS A NUMBER OF SPECIALTY PRIMERS FOR USE OVER
COMPLETED TILE INSTALLATIONS SIMILAR IN MATERIAL. DESIGN. AND EXTENT TO
DIFFICULT SUBSTRATES SUCH AS BLEEDING WOODS, GREASE, CRAYON MARKINGS,
THAT INDICATED FOR THIS PROJECT AND WITH A RECORD OF SUCCESSFUL
HARD GLOSSY SURFACES, GALVANIZED METAL, RUSTED AND OTHER SURFACES WHERE
IN-SERVICE PERFORMANCE.
PAINT ADHESION OR STAIN SUPPRESSION IS A PARTICULAR PROBLEM.
ANY SURFACE CONCERN SHOULD BE BROUGHT TO THE ATTENTION OF THE BENJAMIN
5. DELIVER AND STORE PACKAGED MATERIALS IN ORIGINAL CONTAINERS WITH SEALS
MOORE RETAILER SUPPLYING MATERIAL ON THE JOB.
UNBROKEN AND LABELS INTACT UNTIL TIME OF USE. COMPLY WITH REQUIREMENT OF
ANSI A137.1 FOR LABELING SEALED TILE PACKAGES. PREVENT DAMAGE OR
COATING SYSTEMS
CONTAMINATION TO MATERIALS BY WATER, FREEZING, FOREIGN MATTER, AND OTHER
CAUSES.
THIS LIBERTY MUTUAL AND BENJAMIN MOORE GUIDE SPECIFICATION IS BASED ON THE
USE OF BENJAMIN MOORE REGAL SELECT PRODUCTS. REGAL SELECT PRODUCTS ARE
6. MAINTAIN ENVIRONMENTAL CONDITIONS AND PROTECT WORK DURING AND AFTER
SELF- PRIMING. JOBS SHOULD BE BID FOR TWO (2) COATS OF THE SPECIFIED REGAL
INSTALLATION TO COMPLY WITH REFERENCED STANDARDS AND MANUFACTURERS
SELECT PRODUCT. ANY CONCERNS THAT WILL AFFECT THE PRODUCT PERFORMANCE
PRINTED RECOMMENDATIONS, MAINTAIN TEMPERATURES AT 50 DEG F (10 DEG C) OR
IN A NEGATIVE WAY MUST BE BROUGHT TO A PROJECT REPRESENTATIVE'S
MORE IN TILED AREAS DURING INSTALLATION AND FOR 7 DAYS AFTER COMPLETION,
ATTENTION PRIOR TO APPLYING ANY COATING.
UNLESS HIGHER TEMPERATURES ARE REQUIRED BY REFERENCED INSTALLATION
STANDARD OR MANUFACTURER'S INSTRUCTIONS.
4. COLOR & HIDE-
7. DELIVER EXTRA MATERIALS TO OWNER. FURNISH QUANTITY OF FULL-SIZE UNITS
COLORI TO BE USED SHALL BE CHOSEN FROM A BENJAMIN MOORE COLOR
EQUAL TO 3 PERCENT OF AMOUNT INSTALLED, FOR EACH TYPE, COMPOSITION,
SELECTOR. A LIBERTY MUTUAL REPRESENTATIVE SHALL APPROVE COLOR AND MATCH
COLOR, PATTERN, AND SIZE, PACKAGED WITH PROTECTIVE COVERING FOR STORAGE
BEFORE PAINTING BEGINS.
AND IDENTIFIED WITH LABELS CLEARLY DESCRIBING CONTENTS.
PLEASE NOTE THAT SOME COLORS MAY NOT COVER IN THE SPECIFIED NUMBER OF
COATS!
B. PRODUCTS - GENERAL: ANSI CERAMIC TILE STANDARD: PROVIDE TILE THAT COMPLIES
IT IS THE APPLICATOR'S RESPONSIBILITY TO APPLY ENOUGH COATS OF THE SPECIFIED
WITH ANSI A137.1, 'SPECIFICATIONS FOR CERAMIC TILE,* FOR TYPES, COMPOSITIONS,
MATERIAL TO ACHIEVE COMPLETE HIDE AND THE CORRECT COLOR.
AND OTHER CHARACTERISTICS INDICATED. ANSI STANDARDS FOR TILE INSTALLATION
REGAL SELECT PRODUCTS MUST BE APPLIED AT THE CORRECT SPREAD RATE TO
MATERIALS: PROVIDE MATERIALS COMPLYING WITH ANSI STANDARDS REFERENCED IN
INSURE PROPER PRODUCT PERFORMANCE, EXTREME COLOR CHANGES AND PROBLEM
wSETTING MATERIALS* AND "GROUTING MATERIALS" ARTICLES.
SURFACES MUST BE ADDRESSED PRIOR TO COATING TO INSURE PROPER HIDE.
MATCHED IN ACCORDANCE WITH THE FOLLOWING: DELTA E DIFFERENCE OF NO
GREATER THAN 1.0 USING THE HUNTER (LAB SCALE).
B. SINGLE SOURCE RESPONSIBILITY: PROVIDE ALL COMPONENTS OF THE WALL
PROTECTION SYSTEM MANUFACTURED BY THE SAME COMPANY TO ENSURE
COMPATIBILITY OF COLOR, TEXTURE AND PHYSICAL PROPERTIES.
9. MINI EXTRUDED MATERIAL SHOULD BE HIGH IMPACT ACROVYN BY
OCONSTRUCTION SPECIALITIES, INI OR APPROVED EQUAL. HIGH IMPACT ACROVYN TO
BE WITH PEBBLETTE GRAIN TEXTURE WITH THICKNESS AS INDICATED. CHEMICAL
AND STAIN RESISTANCE SHOULD BE PER ASTM D-1308 STANDARDS AS ESTABLISHED
BY THE MANUFACTURER. COLORS TO BE AS INDICATED IN THE FINISH SCHEDULE
FROM ONE OF MANUFACTURIER'S STANDARD COLOR RANGE.
10, ALUMINUM; EXTRUDED ALUMINUM RETAINERS SHOULD BE 6063-T6 ALLOY OF
THICKNESS INDICATED. MINIMUM STRENGTH AND DURA131LITY PROPERTIES AS
SPECIFIED IN ASTIM 8221.
11. FASTENERS; ALL FASTENERS TO BE NON -CORROSIVE AND COMPATIBLE WITH
ALUMINUM RETAINERS. ALL NECESSARY FASTENERS TO BE SUPPLIED BY THE
MANUFACTURER.
12, PREASSEMBLE COMPONENTS IN THE SHOP TO THE GREATEST EXTENT POSSIBLE
TO MINIMIZE FIELD ASSEMBLY. SURFACE PREPARATION: PRIOR TO INSTALLATION,
CLEM SUBSTRATE TO
13, REMOVE DIRT, DEBRIS AND LOOSE PARTICLES. PERFORM ADDITIONAL PREPARATION
PROCEDURES AS REQUIRED BY MANUFACTURER'S INSTRUCTIONS.
14, INSTALL THE WORK OF THIS SECTION IN STRICT ACCORDANCE WITH THE
MANUFACTURERS RECOMMENDATIONS. USING ONLY APPROVED MOUNTING HARDWARE,
AND LOCATING ALL COMPONENTS FIRMLY INTO POSITION, LEVEL AND PLUMB.
15. ADJUST INSTALLED END CAPS AS NECESSARY TO ENSURE TIGHT SEAMS.
16. WHERE SPLICES OCCUR IN HORIZONTAL RUNS OF OVER 20 FEET, SPLICE ALUMINUM
RETAINER AND VINYL COVER AT DIFFERENT LOCATIONS ALONG THE RUN.
09 72 00 WALLCOVERING
1. REFER TO FINISH SCHEDULE AND FINISHES AS NOTED ON DRAWINGS FOR LOCATION
AND EXTENT OF ALL WALLCOVERINGS TO BE FURNISHED AND INSTALLED BY THE
GENERAL CONTRACTOR.
2. EXAMINE THE SUBSTRATES SCHEDULED TO RECEIVE WAILLCOVERINGS FOR COMPLIANCE
WITH REQUIREMENTS AND CONDITIONS AFFECTING PERFORMANCE OF WALLCOVERING
WORK. MAKE CERTAIN THAT WALL SURFACE$ ARE FREE FROM DEFECTS AIRD
IMPERFECTIONS THAT COULD SHOW THROUGH THE FINISHED SURFACE.
3. ALL MATERIALS SHALL BE INSTALLED BY SKILLED WORKMEN, IN STRICT ACCORDANCE
WITH MANUFACTURIER'S INSTRUCTIONS.
4. SEAL GYPSUM BOARD WITH LATEX PRIMER BEFORE THE APPLICATION OF ANY
WALLCOVERING
5. ADHESIVES TO BE USED IN THE APPLICATION OF WALLCOVERING TO BE PRE -MIXED AS
RECOMMENDED BY THE WALLOOVERING MANUFACTURER FOR SURFACES INVOLVED.
6. WALLCOVERING INSTALLATION:
A. USE W&LCOVERING ROLLS IN CONSECUTIVE NUMERICAL SEQUENCE OF THE
MANUFACTURER.
B. PLACE W&LCOWRIN3 PANELS CONSECUTIVELY IN EXACT ORDER THEY ARE CUT FROM
THE ROLL, INCLUDING FILLING ALL SPACES ABOVE OR BELOW WINDOWS, DOOR OR
SIMILAR PENETRATIONS.
C. TRIM ADDITIONAL SALVAGE WHERE REQUIRED TO ACHIEVE A COLOR AND PATTERN
MATCH AT SEAMS.
D. APPLY ADHESIVE TO FABRIC BACK USING A ROLLER OR PASTE MUSIFI. ME CONTACT
CEMENT WHERE ADHERING TO METAL.
E. HMO NKINPMATCHED PATTERNS BY OVERLAPPING THE EDGES AND DOUBLE CUTTING
THROUGH BOTH THICKNESSES.
F. WRAP W�LCOVERING 6* BEYOND INSIDE AND OUTSIDE CORNERS, NO CUTTING AT
CORNERS PERMITTED.
0. NO HORIZONTAL SEAMS PERMITTED. EXCEPT AS SHOWN.
H. USE STIFF BRISTLED BRUSH OR FLEXIBLE BROAD KNIFE TO ELIMINATE AIR POCKETS
AND TO SECURE WALL COVERING TO SUBSTRATE SURFACE.
1. WITH A DAMP SPONGE REMOVE EXCESS ADHESIVE FROM EACH SEAM AS IT IS MADE
AND WIPE CLEAN AND DRY WITH A CLOTH TOWEL.
J. THE INSTALLED W&LCOVERING SHALL BE SECURE, SMOOTH. CLEAN, WITHOUT
WRINKLES, GAPS OR OVERLAPS.
7. IF CLEANING IS REQUIRED, USE ONLY MATERIALS AND METHOD RECOMMENDED BY
MANUFACTURER OF WALLCOVERING USED.
B. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR UNROLLING AND CHECKING THE
WALLCOVERING FOR DEFECTS IMMEDIATELY UPON DELIVERY AND VERIFYING
MATERIAL MATCHES MATERIAL SPECIFIED BY ARCHITECT. DO NOT HANG DEFECTIVE
WALLCOVERING.
I 1 45 20 COMMERCIAL GRADE APPLIANCES
1. PRODUCT DATA:- SUBMIT MANUFACTLJRER36 SPECIFICATIONS AND INSTALLATION
INSTRUCTIONS FOR EACH TYPE OF COMMERCIAL GRADE APPLIANCE. INCLUDING DATA
INDICATING COMPLIANCE WITH REQUIREMENTS. SUIDMIT OPERATING AND MAINTENAISCE
INSTRUCTIONS FOR EACH ITEM OF COMMERCIAL GRADE AEFLIANCE.
2. SUBMIT MANUFACTURERS STANDARD WRITTEN WARRANTY FOR EACH ITEM OF
COMMERCIAL GRADE APPLIANCE.
3. GENERAL: COMPLY WITH MFR'S INSTRUCTIONS & RECOMMENDATION.
4. BUILT-IN EQUIPMENT: SECURELY ANCHOR UNITS TO SUPPORTING CASINETRY OR
COLINTERTOPS AND CONCEALED FASTENERS. VERIFY THAT CLEARANCES ARE
ADEQUATE FOR PROPER FUNCTIONING AND ROUGH OPENINGS ARE COMPLETELY
CONCEALED.
5. TESTING: TEST EACH ITEM OF COMMERCIAL GRADE APPLIANCES TO VERIFY PROPER
OPERATION. MAKE NECESSARY ADJUSTMENTS.
6. ACCESSORIES: VERIFY THAT ACCESSORY ITEMS REQUIRED HAVE BEEN FURNISHED.
L
E
W
j
I S C
.
A R C H I T E C T U R E
I N T E R I 0 R D E S I G IN
211 South 12th St.
Phila., PA 1 9107
2 1 5 . 9 2 2 . 7 0 6 6
THE CENERAL CONTRACTOR IS RESPONSIBLE
TO VERIFY ALL DIMENSIONS ON SITE AND
CONFIRM SUCH DIMENSIONS AGAINST ACTUAi
SITE CONDERONS. THE GENERAL CONTRACT-
OR SHALL COORDINATE ALL WORK AND
RELATED TRADES, AND SHALL NOTIFY THE
ARCHITECT OF ANY INTERFERENCE OF
MECHANICAL, ELECTRICAL, OR PLUMIRIMC
WORK WITH THE ARCHITECTURAL WORK AND
OF ANY CONFLICTS OR DISCREPANCIES IN
DIMENSION$ ACAIN5T ON SITE CONDITIONS
PRIOR TO PROCEEDIPN� WITH THE WORK OR
PROCUREMENT OF MATERIALS.
0 III
j`m7
a �M!Z .
a 11
450 East 96th St
3rd Floor
Indianapolis IN 46240
Scale N/A
Drawing:
Construction
Notes
No. A. 8' Is 0 0
-
I I
DATE: 10/23/19