GENERAL DEMOLITION NOTES
1. THESE DRAWINGS ARE DIAGRAMMATIC ONLY AND ARE TO BE USED AS A GUIDELINE ONLY
FOR THE SCOPE OF DEMOUTION WORK. THE CONTRACTOR SHALL VISIT THE PROJECT
SITE DURING THE BID PHASE TO VERIFY THE EXACT CONDITIONS AND SCOPE OF WORK
REQUIRED FOR A COMPLETE AND INCLUSIVE DEMOLITION PACKAGE.
2. THE CONTRACTOR SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS
TO COMPARE THEM WITH THE CONTRACT DOCUMENTS AND TO HAVE SATISFIED HIMSELF
AS TO THE CONDITIONS OF THE PREMISES, THE SITE, ANY OBSTRUCTIONS, THE ACTUAL
LEVELS, ACCESS PANELS, AND ALL OTHER EXISTING CONDITIONS. THE CONTRACTOR
SHALL VERIFY ALL DIMENSIONS IN THE FIELD, SHALL CHECK LOCATION OF AND
CONNECTION TO EXISTING FACIUTES, AND SHALL ASSUME All RESPONSIBIUTY FOR SAME.
3. THE CONTRACTOR SHALL COORDINATE WITH THE TERI AND/OR BUILDING MANAGEMENT
ALL INTERRUPTION OF ELECTRICAL SERVICES WITHIN THE TENANT SPACE AND/OR
BUILDING.
4. ALL EXISTING LUMINAIRES AND ASSOCIATED CONTROLS, ELECTRICAL EQUIPMENT, WIRING
DEVICES, FIRE ALARM DEVICES, ETC. NOT INDICATED ON THIS PUN SHALL BE EXISTING
TO REMAIN, UNLESS SPECIFICALLY NOTED OTHERWISE,
5. FOR ALL RENOVATION/REMOLDING WORK, INCLUDING ALL AREAS OF NO OR MINIMAL
WORK, EXISTING ELECTRICAL SERVICES SHALL BE MAINTAINED TO LUMINAIRES, EQUIPMENT,
WIRING DEVICES, ETC. (POWER, LIGHTING, ETC.), THAT ARE REQUIRED TO BE MAINTAINED.
THE CONTRACTOR SHA1 BE RESPONSIBLE TO MAINTAIN THESE SERVICES, EQUIPMENT,
WIRING DEVICES THAT ARE EXISTING TO REMAIN, WHETHER OR NOT INDICATED ON THE
PLANS.
6. DISCONNECT AND REMOVE ALL EXISTING ELECTRICAL EQUIPMENT, WIRING DEVICES,
TELECOM DEVICES, BUNK COVER PLATES, ETC. LOCATED IN WALLS/PARTMONS LABELED
AS i0 BE REMOVED °. REMOVE ALL EXISTING BRANCH CIRCUITING (CONDUCTORS AND
CONDUIT) BACK TO UST ACTIVE DEVICE (OR SOURCE IF NO ACTIVE DEVICES REMAIN).
7. ALL ELECTRICAL LUMINAIRES, EQUIPMENT, WIRING DEVICES, TELECOMMUNICATIONS
VOICE/DATA CABUNG, ETC. SHALL BE REMOVED COMPLETE, BACK TO SOURCE,
PANELBOARD, TERMINAL BOARDS, ETC.), INCLUDING ALL BRANCH CIRCUITING,
CONDUCTORS AND CONDUIT), FEEDERS, SUPPORTS, JUNCTION BOXES, PULL BOXES, ETC.
B. MAINTAIN OR PROVIDE TEMPORARY ELECTRICAL SERVICES, SUCH AS UGHTING AND POWER
IN ALL AREAS OF DEMOLITION AND SURROUNDING AREAS NOT IN DEMOLITION.
9. THE CONTRACTOR SHALL COORDINATE WITH THE ARCHITECTURAL, MECHANICAL HVAC, AND
PLUMBING DEMOLITION DRAWINGS FOR ALL EQUIPMENT BEING DEMOLISHED, AND SHALL
DISCONNECT AND REMOVE COMPLETE THE ELECTRICAL SERVICES TO ALL EQUIPMENT AND
WIRING DEVICES.
10. EQUIPMENT AND WIRING DEVICES INDICATED AS "XR", (EXISTING TO BE RELOCATED),
SHALL BE STORED FOR RE —USE AS INDICATED "XN% (NEW LOCATION OF EXISTING
RELOCATED DEVICE), ON NEW PLAN DRAWINGS. DEVICES SHALL BE CLEANED,
LUMINAIRES RE—LAMPED PER SPECIFICATIONS, AND BALLAST REPLACED WHERE FOUND TO
BE INOPERABLE.
11. EXISTING FIRE ALARM DEVICES THAT ARE XM", (EXISTING TO REMAIN), SHALL BE
PROTECTED FROM CONSTRUCTION DAMAGE AND DIRT. THE FIRE ALARM SYSTEM SHALL
BE KEPT OPERABLE DURING CONSTRUCTION.
12. ANY CIRCUITS FEEDING THROUGH EQUIPMENT OR DEVICES THAT ARE BEING DEMOLISHED,
REWORKED, OR RELOCATED, AND FEEDING OTHER EQUIPMENT/DEVICES THAT REMAIN ARE
TO BE MAINTAINED.
13. ALL CUEING AND PATCHING OF WALLS, COUNGS, OR FLOORS THAT ARE DISTURBED BY
DEMOLITION SHALL BE RETURNED TO THEIR ORIGINAL OONDMON. REFER TO THE
ARCHITECTURAL DOCUMENTS FOR EXACT SPECIFICATION REQUIREMENTS. PATCH FLOOR
TO ORIGINAL CONSTRUCTION SPECIFICATIONS AND U.L. FIRE RATING LISTINGS FOR ALL
FLOOR MOUNTED DEVICES SUCH AS FLOOR BOXES, (FIRE RATED) POKE—THROUGHS, ETC.
WHICH HAVE BEEN REMOVED.
14. ALL EQUIPMENT AND/OR DEVICES THAT ARE REMOVED AND NOT RE —USED SHALL BE
TURNED OVER TO THE TENANT AND/OR BUILDING MANAGEMENT OR DISPOSED OF PER
THEIR DIRECTION.
15. ALL MATERIAL TO BE DISPOSED SHALE BE DONE UNDER STRICT ACCORDANCE WITH ALL
FEDERAL, STATE, AND LOCAL CODE REQUIREMENTS.
0
CxM
L xl YxM
,OTYPICAL
CD
%M
Integrated
Engineering
Consultants, Inc.
9700 ROCKSIDE RD. SUITE #290
CLEVELAND, OH 44125
fl: 216.901.6711
fl: 216.901.6712
wVaVvJ in0.00
PE11800575
•'.
<•, STATE OF
Electrical Demolition Power Plan SCALE 0. 1
DEMOLITION PLAN CODED NOTES:
01 REMOVE EXISTING 4" CONDUIT SLEEVES AND FIRE RATED POKE —THROUGH DEVICES(`�CD)
AND PATCH FLOOR TO ORIGINAL SPECIFICATIONS AND FIRE RATING. SEE SRCHITECTURAL
SPECIFICATIONS.
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes