HomeMy WebLinkAboutM-3.03H
E
L
L Y E R
LEWIS=
RELEASED FOR CONSTRUCTION
Suhject to compliance with all regulations
of State and Local Codes
City of Camel (�
gvm�laa�dlDA�L
• Integrated
/1� Engineering
Consultants,Inc.
9700 ROCKSIDE RD. SUITE #290
CLEVELAND, OH 44125
rDI. 019 onI 9711
Mechanical HVAC Plan SCALE:
/8M = I-o•
MECHANICAL HVAC PLAN GENERAL NOTES:
1. MECHANICAL HVAC CONTRACTOR SHALL PERFORM A FIELD SURVEY PRIOR TO
FABRICATING OR INSTALLING ANY NEW WORK OR MODIFYING EXISTING. NOTIFY
ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOUND FOR DIRECTION PRIOR
TO PROCEEDING.
2. ANY EXISTING SYSTEMS NOTED AS EXISTING TO REMAIN SHALL BE FIELD
VERIFIED FOR DEFICIENCIES.
3. MECHANICAL WAG CONTRACTOR SHALL COORDINATE ANY NECESSARY
SHUTDOWNS WITH BUILDING/MANAGEMENT.
4. MECHANICAL HVAC CONTRACTOR SHALL CAP ALL UNUSED DUCT TAPS AND
OPENINGS ON EXISTING SUPPLY AIR DUCT MAIN AND SEAL AIR TIGHT.
5. MECHANICAL HVAC CONTRACTOR SHALL PROVIDE ALL ACCESS PANELS
REQUIRED FOR THEIR TRADE. SEE ARCHITECTURAL DRAWINGS FOR
SPECIFICATIONS.
6. ROUTE DUCTWORK BETWEEN JOISTS AND HIGH AS POSSIBLE THROUGHOUT
SPACE. TRANSITON DOWN TO ACOUSTICAL CEILING.
7. MECHANICAL HVAC CONTRACTOR SHALL REUSE EXISTING DUCTWORK AS
PRACTICAL.
8. RELOCATE RETURN AIR GRILLES ACCORDING TO NEW CEILING GRID.
9. RELOCATE SUPPLY AIR GRILLES AS REQUIRED FOR NEW CEILING GRID. MAKE
NECESSARY ADJUSTMENTS IN DUCTWORK WHERE REQUIRED.
10. ALL THERMOSTATS LOCATED WITHIN PRIVATE OFFICES ARE TO BE LOCATED
WITHIN 18m OF THE DOOR OPENING.
11. MECHANICAL WAG CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES
AND PREPARE INTERFERENCE DRAWINGS FOR SUBMITTAL, PRIOR TO ANY
FABRICATION OR INSTALLATION.
MECHANICAL HVAC PLAN CODED NOTES: pp
01 PROVIDE NEW THERMOSTAT AND CONTROL WIRING FOR EXISTING HEAT PUMP
TIE INTO BUILDING AUTOMATION SYSTEM AS REQUIRED BY LANDLORD.
COORDINATE WITH LANDLORD FOR ADDITIONAL INFORMATION.
tD PROPORTIONALLY BALANCE FLOOR OUTDOOR AIR EVENLY BETWEEN OUTLETS.
aQ BALANCE BRANCH DUCTWORK TO DISCHARGE CFM INDICATED INTO PLENUM
SPACE.
•Q REBALANCE EXISTING WATER SOURCE HEAT PUMP TO CFM INDICATED ON
SCHEDULE.
0 EXTEND BUILDING REUEF DUCTWORK INTO TENANT SPACE AS SHOWN.
r
25e
e
25e
A
23e
Q
n
1 IN
ARCHITECTURE
INTERIOR DESIGN
Project:
10
Liberty
Mutual.
INSURANCE
450 East 96th St
3rd Floor
Indianapolis IN 46240
Project No: 047.S6
Drawn by:
jH
Checked by:
Hf
HH
Approved by:
HjHH
Client Approval:
Date:
Issue For Bid:
11 /02/18
Issue For Permit:
11 /05/18
No.
Date
Revision
Scale: 1 /8" =
1'-0'1
Drawing:
Mechanical
HVAC Plan
No. M-103
DATE: 10/23/19