Loading...
HomeMy WebLinkAboutM-3.03H E L L Y E R LEWIS= RELEASED FOR CONSTRUCTION Suhject to compliance with all regulations of State and Local Codes City of Camel (� gvm�laa�dlDA�L • Integrated /1� Engineering Consultants,Inc. 9700 ROCKSIDE RD. SUITE #290 CLEVELAND, OH 44125 rDI. 019 onI 9711 Mechanical HVAC Plan SCALE: /8M = I-o• MECHANICAL HVAC PLAN GENERAL NOTES: 1. MECHANICAL HVAC CONTRACTOR SHALL PERFORM A FIELD SURVEY PRIOR TO FABRICATING OR INSTALLING ANY NEW WORK OR MODIFYING EXISTING. NOTIFY ARCHITECT/ENGINEER OF ANY DISCREPANCIES FOUND FOR DIRECTION PRIOR TO PROCEEDING. 2. ANY EXISTING SYSTEMS NOTED AS EXISTING TO REMAIN SHALL BE FIELD VERIFIED FOR DEFICIENCIES. 3. MECHANICAL WAG CONTRACTOR SHALL COORDINATE ANY NECESSARY SHUTDOWNS WITH BUILDING/MANAGEMENT. 4. MECHANICAL HVAC CONTRACTOR SHALL CAP ALL UNUSED DUCT TAPS AND OPENINGS ON EXISTING SUPPLY AIR DUCT MAIN AND SEAL AIR TIGHT. 5. MECHANICAL HVAC CONTRACTOR SHALL PROVIDE ALL ACCESS PANELS REQUIRED FOR THEIR TRADE. SEE ARCHITECTURAL DRAWINGS FOR SPECIFICATIONS. 6. ROUTE DUCTWORK BETWEEN JOISTS AND HIGH AS POSSIBLE THROUGHOUT SPACE. TRANSITON DOWN TO ACOUSTICAL CEILING. 7. MECHANICAL HVAC CONTRACTOR SHALL REUSE EXISTING DUCTWORK AS PRACTICAL. 8. RELOCATE RETURN AIR GRILLES ACCORDING TO NEW CEILING GRID. 9. RELOCATE SUPPLY AIR GRILLES AS REQUIRED FOR NEW CEILING GRID. MAKE NECESSARY ADJUSTMENTS IN DUCTWORK WHERE REQUIRED. 10. ALL THERMOSTATS LOCATED WITHIN PRIVATE OFFICES ARE TO BE LOCATED WITHIN 18m OF THE DOOR OPENING. 11. MECHANICAL WAG CONTRACTOR SHALL COORDINATE WITH ALL OTHER TRADES AND PREPARE INTERFERENCE DRAWINGS FOR SUBMITTAL, PRIOR TO ANY FABRICATION OR INSTALLATION. MECHANICAL HVAC PLAN CODED NOTES: pp 01 PROVIDE NEW THERMOSTAT AND CONTROL WIRING FOR EXISTING HEAT PUMP TIE INTO BUILDING AUTOMATION SYSTEM AS REQUIRED BY LANDLORD. COORDINATE WITH LANDLORD FOR ADDITIONAL INFORMATION. tD PROPORTIONALLY BALANCE FLOOR OUTDOOR AIR EVENLY BETWEEN OUTLETS. aQ BALANCE BRANCH DUCTWORK TO DISCHARGE CFM INDICATED INTO PLENUM SPACE. •Q REBALANCE EXISTING WATER SOURCE HEAT PUMP TO CFM INDICATED ON SCHEDULE. 0 EXTEND BUILDING REUEF DUCTWORK INTO TENANT SPACE AS SHOWN. r 25e e 25e A 23e Q n 1 IN ARCHITECTURE INTERIOR DESIGN Project: 10 Liberty Mutual. INSURANCE 450 East 96th St 3rd Floor Indianapolis IN 46240 Project No: 047.S6 Drawn by: jH Checked by: Hf HH Approved by: HjHH Client Approval: Date: Issue For Bid: 11 /02/18 Issue For Permit: 11 /05/18 No. Date Revision Scale: 1 /8" = 1'-0'1 Drawing: Mechanical HVAC Plan No. M-103 DATE: 10/23/19