HomeMy WebLinkAboutX-0.01LIFE SAFETY LEGEND
BUILDING COMMON
AREA
®
STAIR TOWER
BUSINESS - I PERSON/100 SF
---�
COMMON PATH OF
TRAVEL
------
EGRESS ROUTE
— —
EXIT DISTANCE
®
FIRE EXTINGUISHER
0 CABINET
CEILING MOUNTED
ILLUMINATED EXIT SIGN
CR CARD ACCESS PROXIMITY READER FOR TENANT'S SECURITY SYSTEM
MD MOTION DETECTOR DEVICE FOR TENANT'S SECURITY SYSTEM. MOTION
DETECTOR DEVICE IS NOT TIED INTO THE DOOR HARDWARE.
CODE DATA
1. USE GROUP: B
2. CONSTRUCTION CLASSIFICATION: 118 (100% SPRINKLERED)
3. AREA LIMITATIONS
A. AREA PER FLOOR: EXISTING
B. PROPOSED TENANT AREA THIRD FLOOR: 22.817 USF
4. OCCUPANCY LOAD:
ALLOWABLE PER CODE
TENANT AREA: 22,817 USF / 100 GROSS = 226 PEOPLE
(BUSINESS)
5. EGRESS WIDTH PER OCCUPANT:
DOORS; 32' MIN. REQUIRED BETWEEN THE FACE OF THE DOOR
AND THE STOP WITH THE DOOR OPEN 90 DEGREES,
33'CLEAR AT ALL PROPOSED DOORS (MIN.)
RAMPS: 44' MIN.
CORRIDORS: 44' MIN. PROVIDED
STAIRWAYS 0 .2'/OCC
STAIRS 40' MIN. REQUIRED; 44' PROVIDED
6. MAXIMUM LENGTH OF EGRESS TRAVEL: 30OFT
7. MAXIMUM COMMON PATH OF TRAVEL: IODFT
8. MAXIMUM DEAD END CORRIDOR: SOFT
9. INTERIOR WALL AND CEILING FINISH REQUIREMENTS (SPRINKLERED B
OCCUPANCY):
A. EXIT ENCLOSURE AND EXIT PASSAGEWAYS - B
B. CORRIDORS - C
C. ROOMS & ENCLOSED SPACES - C
APPLICABLE BUILDING CODES
A. BUILDING CODE: INDIANA BUILDING CODE, 2014 EDITION (INTERNATIONAL
BUILDING CODE, 2012 EDITION, IST PRINTING); ANSI A117.1-2009
B. MECHANICAL CODE: INDIANA MECHANICAL CODE, 2014 EDITION (INTERNATIONAL
MECHANICAL CODE, 2012 EDITION, IST PRINTING)
C. PLUMBING CODE: INDIANA PLUMBING CODE 2012 EDITION (UNIFORM PLUMBING
CODE 2006 EDITION)
D. FIRE CODE: INDIANA FIRE CODE, 2014 EDITION (INTERNATIONAL FIRE CODE,
2012 EDITION, IST PRINTING)
E. ELECTRICAL CODE: INDIANA ELECTRICAL CODE 2009 EDITION (NFPA 70-2008)
F. ENERGY CONSERVATION
CODE: INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE 90.1.
2007 EDITION, AS AMENDED)
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Calmed
DATE: 10/23/19
LN
0
\
i
M11
i
a°
■■i
11
Iv
41
MD
ABC
340
oa
DF
303
NFE�
D ROOMNCE
339 ®nn
I
\ \ ®®QQ
OPEN
+I�rI I
I
I
I'
\ I
I
I
I
I
I
COLLAR
336
I
I
I
e I
I
I
I
I
\ I
EPI,
m
TR
OOM
332
0 4
00c
m \ COLLAB
335
UU �\\ Liu
\
\
\
POI00
306
U
X\
p E
yam, OFF „{ ,
lel
I
M 20TM S
316
I u I
'BEAEIANI
314E
HIVE
314A
MAX DIAGONAL: 231'-5'
DISTANCE BETWEEN EXITS:107'-2'
107'-2' > A MAX DIAGONAL
ROOM
313
SCALE:
HELLYER
LEWIS=
ARCHITECTURE
INTERIOR
DESIGN
211 South 1 2th St.
Ph ila., PA 19107
215.922. 7066
EGENERAL TRACTOR IS RESPONSIBLE
VERIFY ALL I TODIMENSIONS ON SITE AND
CONFIRM SUCH DIMENSIONS AGAINST ACTUAI
SITE CONDITIONS. THE GENERAL CONTRACT-
OR SHALL COORDINATE ALL WORK AND
RELATED TRADES, AND SHALL NOTIFY THE
ARCHITECT OF ANY INTERFERENCE OF
MECHANICAL, ELECTRICAL, OR PLUMRINC
WORK WITH THE ARCHITECTURAL WORK AND
F ANY CONFLICTS OR DISCREPANCIES IN
DIMENSIONS AGAINST ON SITE CONDITIONS
PRIOR TO PROCEEDING WITH THE WORK OR
PROCUREMENT OF MATERIALS.
C'
1rLtiberty
,�►.INSURANCE
450 East 96th St
3rd Floor
Indianapolis IN 46240
Drawing:
Life Safety
Plan
No. X—".O4
LIFE SAFETY FLAN