Loading...
HomeMy WebLinkAboutX-0.01LIFE SAFETY LEGEND BUILDING COMMON AREA ® STAIR TOWER BUSINESS - I PERSON/100 SF ---� COMMON PATH OF TRAVEL ------ EGRESS ROUTE — — EXIT DISTANCE ® FIRE EXTINGUISHER 0 CABINET CEILING MOUNTED ILLUMINATED EXIT SIGN CR CARD ACCESS PROXIMITY READER FOR TENANT'S SECURITY SYSTEM MD MOTION DETECTOR DEVICE FOR TENANT'S SECURITY SYSTEM. MOTION DETECTOR DEVICE IS NOT TIED INTO THE DOOR HARDWARE. CODE DATA 1. USE GROUP: B 2. CONSTRUCTION CLASSIFICATION: 118 (100% SPRINKLERED) 3. AREA LIMITATIONS A. AREA PER FLOOR: EXISTING B. PROPOSED TENANT AREA THIRD FLOOR: 22.817 USF 4. OCCUPANCY LOAD: ALLOWABLE PER CODE TENANT AREA: 22,817 USF / 100 GROSS = 226 PEOPLE (BUSINESS) 5. EGRESS WIDTH PER OCCUPANT: DOORS; 32' MIN. REQUIRED BETWEEN THE FACE OF THE DOOR AND THE STOP WITH THE DOOR OPEN 90 DEGREES, 33'CLEAR AT ALL PROPOSED DOORS (MIN.) RAMPS: 44' MIN. CORRIDORS: 44' MIN. PROVIDED STAIRWAYS 0 .2'/OCC STAIRS 40' MIN. REQUIRED; 44' PROVIDED 6. MAXIMUM LENGTH OF EGRESS TRAVEL: 30OFT 7. MAXIMUM COMMON PATH OF TRAVEL: IODFT 8. MAXIMUM DEAD END CORRIDOR: SOFT 9. INTERIOR WALL AND CEILING FINISH REQUIREMENTS (SPRINKLERED B OCCUPANCY): A. EXIT ENCLOSURE AND EXIT PASSAGEWAYS - B B. CORRIDORS - C C. ROOMS & ENCLOSED SPACES - C APPLICABLE BUILDING CODES A. BUILDING CODE: INDIANA BUILDING CODE, 2014 EDITION (INTERNATIONAL BUILDING CODE, 2012 EDITION, IST PRINTING); ANSI A117.1-2009 B. MECHANICAL CODE: INDIANA MECHANICAL CODE, 2014 EDITION (INTERNATIONAL MECHANICAL CODE, 2012 EDITION, IST PRINTING) C. PLUMBING CODE: INDIANA PLUMBING CODE 2012 EDITION (UNIFORM PLUMBING CODE 2006 EDITION) D. FIRE CODE: INDIANA FIRE CODE, 2014 EDITION (INTERNATIONAL FIRE CODE, 2012 EDITION, IST PRINTING) E. ELECTRICAL CODE: INDIANA ELECTRICAL CODE 2009 EDITION (NFPA 70-2008) F. ENERGY CONSERVATION CODE: INDIANA ENERGY CONSERVATION CODE 2010 (ASHRAE 90.1. 2007 EDITION, AS AMENDED) RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Calmed DATE: 10/23/19 LN 0 \ i M11 i a° ■■i 11 Iv 41 MD ABC 340 oa DF 303 NFE� D ROOMNCE 339 ®nn I \ \ ®®QQ OPEN +I�rI I I I I' \ I I I I I I COLLAR 336 I I I e I I I I I \ I EPI, m TR OOM 332 0 4 00c m \ COLLAB 335 UU �\\ Liu \ \ \ POI00 306 U X\ p E yam, OFF „{ , lel I M 20TM S 316 I u I 'BEAEIANI 314E HIVE 314A MAX DIAGONAL: 231'-5' DISTANCE BETWEEN EXITS:107'-2' 107'-2' > A MAX DIAGONAL ROOM 313 SCALE: HELLYER LEWIS= ARCHITECTURE INTERIOR DESIGN 211 South 1 2th St. Ph ila., PA 19107 215.922. 7066 EGENERAL TRACTOR IS RESPONSIBLE VERIFY ALL I TODIMENSIONS ON SITE AND CONFIRM SUCH DIMENSIONS AGAINST ACTUAI SITE CONDITIONS. THE GENERAL CONTRACT- OR SHALL COORDINATE ALL WORK AND RELATED TRADES, AND SHALL NOTIFY THE ARCHITECT OF ANY INTERFERENCE OF MECHANICAL, ELECTRICAL, OR PLUMRINC WORK WITH THE ARCHITECTURAL WORK AND F ANY CONFLICTS OR DISCREPANCIES IN DIMENSIONS AGAINST ON SITE CONDITIONS PRIOR TO PROCEEDING WITH THE WORK OR PROCUREMENT OF MATERIALS. C' 1rLtiberty ,�►.INSURANCE 450 East 96th St 3rd Floor Indianapolis IN 46240 Drawing: Life Safety Plan No. X—".O4 LIFE SAFETY FLAN