Loading...
HomeMy WebLinkAboutLighting Fixture Plan 3One Lithonia Way • Conyers, Georgia 30012 • Phone: 800.279.8041 • www.lithonia.com © 2011-2017 Acuity Brands Lighting, Inc. All rights reserved. DSX0-LED Rev. 10/25/17 Page 3 of 7 Performance Data Current (A) Performance Package LED Count Drive Current Wattage 120 208 240 277 347 480 Forward Optics (Non-Rotated) P1 20 530 38 0.32 0.18 0.15 0.15 0.10 0.08 P2 20 700 49 0.41 0.23 0.20 0.19 0.14 0.11 P3 20 1050 71 0.60 0.37 0.32 0.27 0.21 0.15 P4 20 1400 92 0.77 0.45 0.39 0.35 0.28 0.20 P5 40 700 89 0.74 0.43 0.38 0.34 0.26 0.20 P6 40 1050 134 1.13 0.65 0.55 0.48 0.39 0.29 P7 40 1300 166 1.38 0.80 0.69 0.60 0.50 0.37 Rotated Optics (Requires L90 or R90) P10 30 530 53 0.45 0.26 0.23 0.21 0.16 0.12 P11 30 700 72 0.60 0.35 0.30 0.27 0.20 0.16 P12 30 1050 104 0.88 0.50 0.44 0.39 0.31 0.23 P13 30 1300 128 1.08 0.62 0.54 0.48 0.37 0.27 Electrical Load Use these factors to determine relative lumen output for average ambient temperatures from 0-40°C (32-104°F). Lumen Ambient Temperature (LAT) Multipliers Ambient Lumen Multiplier 0°C 32°F 1.04 5°C 41°F 1.04 10°C 50°F 1.03 15°C 50°F 1.02 20°C 68°F 1.01 25°C 77°F 1.00 30°C 86°F 0.99 35°C 95°F 0.98 40°C 104°F 0.97 Projected LED Lumen Maintenance Data references the extrapolated performance projections for the platforms noted in a 25°C ambient, based on 10,000 hours of LED testing (tested per IESNA LM-80-08 and projected per IESNA TM-21-11). To calculate LLF, use the lumen maintenance factor that corresponds to the desired number of operating hours below. For other lumen maintenance values, contact factory. Operating Hours 25000 50000 100000 Lumen Maintenance Factor 0.96 0.92 0.85 Motion Sensor Default Settings Option Dimmed State High Level (when triggered) Phototcell Operation Dwell Time Ramp-up Time Ramp-down Time PIR or PIRH 3V (37%) Output 10V (100%) Output Enabled @ 5FC 5 min 3 sec 5 min *PIR1FC3V or PIRH1FC3V 3V (37%) Output 10V (100%) Output Enabled @ 1FC 5 min 3 sec 5 min *for use with Inline Dusk to Dawn or timer. PER Table Control PER (3 wire) PER5 (5 wire)PER7 (7 wire) Wire 4/Wire5 Wire 4/Wire5 Wire 6/Wire7 Photocontrol Only (On/Off)Wired to dimming leads on driver Wired to dimming leads on driver Wires Capped inside fixture ROAM Wired to dimming leads on driver Wired to dimming leads on driver Wires Capped inside fixture ROAM with Motion (ROAM on/off only)Wires Capped inside fixture Wires Capped inside fixture Wires Capped inside fixture Future-proof*Wired to dimming leads on driver Wired to dimming leads on driver Wires Capped inside fixture Future-proof* with Motion Wires Capped inside fixture Wires Capped inside fixture Wires Capped inside fixture  Recommended  Will not work  Alternate *Future-proof means: Ability to change controls in the future.