Loading...
HomeMy WebLinkAboutElectrical PlanR R Recessed light R R R R R R R R R R R R R Microwave +74" Stove (gas) Duplex Receptacle Single Pole Switch S Threeway Switch S Combination light/fan Wall mounted light fixture GFCI Receptacle R R R RR S S S S SS S S Exterior Lights S Garage Lights S Relocate dining room switch S S S S S S Exterior flood lights S S S S S Relocate stair light S Replace existing Relocate Notes: 1) Re-route existing dryer wire to upstairs laundry room 2) Add GFCI receptacles to circuits in kitchen & bathrooms 3) Replace all switches, receptacles and cover plates R Sunroom Family Room Living Room Kitchen Dining Room Garage Bedroom Bathroom Laundry Room Foyer 4) Install all new smoke detectors to Indiana Code. All alarms to be hard wired and sound simultaneously. Electrical Plan 10/28/19 Mike Sheeks