Loading...
HomeMy WebLinkAboutC040.0_UTILITY_PLAN PROPOSED OFFICE 3,500 SF PROPOSED RESTAURANT 4,000 SF 24 9 1.70 ACRES X X X XX G G G G G G WEST LINE SW 1/4 SEC 6, T17N, R3E HAMILTON COUNTY 78.69' O H E O H E O H E O H E O H E O H E O H E O H E O H E O H E OHE O H E TEMPORARY SITE BENCHMARK 2 SANITARY SEWER FORCE MAIN SIGN E UGE UGE UGE UGE UGE UGE UGE TX WW COTYPE 2 COTYPE 2 COTYPE 2 COTYPE 2 G COTYPE 2 COTYPE 2 CO CO G G G G G G G G G G GGGGGGGG CO CO CO W W W W 1"= SITE UTILITY PLAN 30'030' TH I S D O C U M E N T H A S B E E N P R E P A R E D B Y P R O G R E S S I V E A E A S A N I N S T R U M E N T O F S E R V I C E , A N D P R O G R E S S I V E A E SH A L L R E T A I N A L L C O M M O N L A W , S T A T U T O R Y A N D O T H E R R E S E R V E D R I G H T S , I N C L U D I N G T H E C O P Y R I G H T T H E R E T O . ISSUANCES REVISIONS NO T F O R CO N S T R U C T I O N If this document is sealed and signed in a digital or electronic format and is received from someone other than the sealing professional identified in the document, you must contact the sealing professional in writing to validate authenticity of the document. The sealing professional disclaims the seal and signature and shall not be liable for any liability associated with it where the authenticity of any digital or electronic seal or signature has not been validated in this manner. NO.DATE DESCRIPTION 6/1 3 / 2 0 1 9 1 1 : 1 1 : 4 9 A M P:\ 7 0 0 5 0 0 1 2 \ W I P D R A W I N G S \ C 4 - S I T E U T I L I T Y . d w g sh o r t j 18 1 1 4 M i l e R d N E G r a n d R a p i d s , M I 4 9 5 2 5 6 1 6 . 3 6 1 . 2 6 6 4 w w w . p r o g r e s s i v e a e . c o m DRAWN BY PROFESSIONAL PROJECT MANAGER FILE NUMBER CHECKED BY CH R I S T I A N B R O T H E R S A U T O M O T I V E PR O P O S E D S E R V I C E CE N T E R MI C H I G A N R O A D , C A R M E L , I N 70050012 JPM REVISED PLANS FOR REVIEW 06/13/2019 R E D D R D . C4 SITE UTILITY PLAN JRS 70050012 CALL 811 NOTE: www.CALL811.com CONTRACTOR TO CONTACT 811 SERVICE AT LEAST 3 WORKING DAYS PRIOR TO CONSTRUCTION, TO CONFIRM LOCATION OF EXISTING UTILITIES. DIAL 811. PROPOSED CHRISTIAN BROTHERS AUT O M O T I V E FINISHED FLOOR ELEV = 901.75 M I C H I G A N R O A D ( U S - 4 2 1 ) 1.5" WATERMAIN TAP 1.5" VALVE AND BOX DIRCTIONALLY DRILL ELECTRICAL SERVICE GAS MAIN TAP 5'x5" TRANSFORMER PAD, ENSURE 10' CLEAR SURROUNDING TRANSFORMER ELECTRIC SERVICE SANITARY SEWER NOTES 1.CONTRACTOR SHALL OBTAIN PERMIT TO CONNECT TO SANITARY SYSTEM FROM THE CITY OF CARMEL AND TRI CO SEWER UTILITY. 2.SANITARY SEWER TO COMPLY WITH TRI CO SEWER UTILITY SANITARY SEWER SPECIFICATIONS. 3.CLEANOUTS TO BE PROVIDED WITHIN 5 FEET OF THE BUILDING EXTERIOR WALL ON ALL LATERALS EXITING THE BUILDING. 4.SANITARY SEWER LATERALS WITHIN SITE SHALL BE (ASTM D-3034) SDR 35. 5.ROOF DRAINS, FOUNDATION DRAINS, AND OTHER CLEAN WATER CONNECTIONS TO THE SANITARY SEWER ARE PROHIBITED. 6.OIL / WATER SEPARATOR TO BE 3 COMPARTMENT AND COMPLY WITH TRI CO SEWER UTILITY SPECIFICATIONS. WATER SERVICE NOTES 1.INSTALL WATER SERVICE WITH MINIMUM 5.0' OF COVER TO TOP OF PIPE. 2.PROVIDE A MINIMUM 18" OF VERTICAL SEPARATION AND 10' OF HORIZONTAL SEPARATION BETWEEN WATER SERVICE AND ALL SANITARY AND STORM SEWERS. 3.WATER SERVICE MATERIAL AND INSTALLATION SHALL BE PERFORMED IN ACCORDANCE WITH CITIZENS ENERGY GROUP WATER DEPARTMENT SPECIFICATIONS. 4.2" AND SMALLER DOMESTIC WATER SERVICE SHALL BE TYPE K COPPER PIPE. 5.COORDINATE WATER TAPS WITH CITY OF CARMEL AND CITIZENS ENERGY GROUP WATER DEPARTMENT. 6.1.5" WATER SERVICE TO SPLIT INSIDE THE BUILDING TO 1" DOMESTIC SERVICE AND 1" IRRIGATION SERVICE WITH SEPARATE 3 4" METERS. 20' PROPOSED WATERMAIN EASEMENT (BY OTHERS) WATERMAIN LOCATION (BY OTHERS) 1.5" WATER SERVICE PROPOSED HYDRANT ASSEMBLY 6" VALVE & BOX 8"x6" REDUCER 370 LF 8" WM TO HYDRANT 2 0 ' PROPOSED SANITARY SEWER EASEMENT (BY OTHERS) 6" SAN IE=897.50 6" SAN IE=897.50 6"x6" WYE IE =897.00 234 LF OF 6" SAN @ 1.9% 4' DIA SAN MH' (BY WOOLPERT) RIM = 898.50 N IE = 891.48 SW IE = 891.58 8" SAN (BY OTHERS) 67 LF OF 6" SAN @1.0% OIL/WATER SEPERATOR, 1000 GAL CLEANOUT 6" IE = 892.40 GENERAL NOTES 1.UTILITY RELOCATIONS REQUIRED BY THE PROJECT SHALL BE THE RESPONSIBILITY OF THE DEVELOPER. UTILITY LINE RELOCATIONS REQUIRED FOR ROAD PROJECTS THAT RESULT IN A CONFLICT WITH PROPOSED DEVELOPMENT SHALL BE THE DEVELOPER TO RESOLVE WITH THE UTILITY. EXISTING POLE LINES REQUIRED TO BE RELOCATED TO WITHIN ONE FOOT OF PROPOSED RIGHT-OF-WAY LINE. CONSTRUCTION LIMITS 24" SAMPLE STRUCTURE WYE 6" IE = ±891.45 GAS SERVICE LINE GAS MAIN EXTENSION (BY WOOLPERT) 10' PUBLIC UTILITY EASEMENT 10' GAS METER AC CONDENSER WATER METERELECTRIC METER