Loading...
HomeMy WebLinkAboutC1 - EXISTING TOPO & DEMO - CIVILEXISTING SANITARY MANHOLI T.O.C. — 867.22' 8' PVC N—S INV. — 852.82' 160' GAS PIPELINE EASEMENT PER M.B. 31, PG. 121 AND M.B. 31, PG 278-280 PRECISE LOCATION AND IWIDTH OF EASEMENT IS CURRENTLY rNDEFINED. J LL CONTRACTORS TO COORDINATE s WITH VECTREN FOR ANY CONSTRUCTION IN PIPELINE EASEMENT L——————— — — — — Jw EXISTING SANITARY MANHOLI T.O.C. — 864.76' 8' PVC N—S INV. — 851.46' RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �VT�tD,M�NDJUa� DATE: \ 10/30/19 SOIL MAP N.T.S. LEGEND - - - - - - - EXISTING V CONTOUR LINE — - EXISTING 5' CONTOUR LINE F5 UNDERGROUND FIBER OPTIC — E — UNDERGROUND ELECTRIC WOOD PRIVACY FENCE —0 EXISTING GAS LINE — PROPERTY LINE ------- ADJOINER/SECTION LINE ----� RIGHT-OF-WAY LINE CENTERLINE SETBACK LINE EASEMENT —PAT— EXISTING OVERHEAD UTILITY LINES EXISTING UNDERGROUND PHONE �— EXISTING TELECOMMUNICATIONS — w — EXISTING WATER LINE — SANITARY SEWER LINE STORM SEWER —�— FLOW LINE r SIGNS . MAILBOX ;®O STORM INLETS .2 STORM MANHOLE ® SOIL BORING UTILITY POLE WATER VALVE (D PHONE MANHOLE UTILITY PEDESTAL f A.D.A. SPACE WATER VALVE P.I.V. WATER METER pQ GAS VALVE 4 GAS METER OS ygITARY MANHOLE CLEAN OUT PIPE BOLLARD ® ELECTRIC TRANSFORMER ® CONDITIONING UNIT FIRE HYDRANT j�[ LIGHT POLE BASE FIRE DEPART. CONNECTION HOLEY MOLEY SAYS "DIG SAFELY" s a s a 3 "IT'S THE LAW" e GILL 2 WORKING 04YHS BEFORE YOU OlG a CALL TOLL FREE PER INDIANA STATE LAW ICB-1-26. IT IS AGAINST THE LAW TO EXCAVATE WITHOUT NOTIFYING THE UNDERGROUND B LOCATION SERVICE TWO (2) WORKING DAYS BEFORE COMMENCING WORK. C EXISTING TOPOGRAPHIC & DEMO PLAN s o � GRAPHIC SCALE e 0 so 45 W TO 150 g "a ( IN FEET) a 1 inch = 30 EL