HomeMy WebLinkAboutM001 - MECHANICAL SYMBOLS6 5 4 3 2 1
NOTE: ALL SYMBOL DESCRIPTIONS ARE SUBJECT TO MODIFICATION ON THE DRAWINGS. ALL SYMBOLS NOT NECESSARILY USED ON THIS PROJECT.
E
11
C
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
\ City of Carmel
` (}
`a 111XNG\IatrM'a1pAAL
DATE: 10/30/19
VALVES & FITTINGS:
GENERAL SYMBOLS:
GATE VALVE POINT OF CONNECTION
BALLVALVE
POINT OF REMOVAL
BUTTERFLY VALVE
CHECK VALVE O PLAN NOTE
GLOBE VALVE El DEMOLITION NOTE
BALANCING VALVE
1 REVISION
PLUG VALVE
A DETAIL BUBBLE
M 501
CONTROL VALVE
1
SOLENOID VALVE SECTION BUBBLE
M501
NEEDLE VALVE
THERMAL EXPANSION VALVE
AUTOMATIC FLOW CONTROL PIPING DESIGNATIONS:
VALVE
S S NEW PIPING
BACK FLOW PREVENTER
s s EXISTING PIPING TO REMAIN
PRESSURE REDUCING, 5----------4 EXISTING PIPING TO BE REMOVED
SELF CONTAINED VALVE
S fi SANITARY
PRESSURE REDUCING,
PILOT OPERATED VALVE f-----i SANITARY VENT
iPOTABLE COLD WATER
RELIEF, PILOT OPERATED
VALVE iPOTABLE HOT WATER(TEMPERATURE AS NOTED)
ANGLE GLOBE VALVE 5---- HOT WATER RETURN
PIPE SLOPES IN DIRECTION OF ARROW
PRESSURE RELIEF,
ANGLE TYPE VALVE
THREE WAY BALL VALVE DIFFUSERS & REGISTERS
THREE WAY GLOBE VALVE
THREE WAY PLUG VALVE
THREE WAY CONTROL VALVE
PIPE TURN 900
LINE BREAK
PIPE ELBOW UP (RISER)
PIPE ELBOW DOWN
PIPE TEE DOWN
CAP OR PLUG
REDUCER, CONCENTRIC
REDUCER, ECCENTRIC
Y-STRAINER
FLEXIBLE CONNECTION
FLANGES
UNION
PIPE GUIDE
PIPE ANCHOR
FILTER (INLINE)
GAUGE
THERMOMETER
STEAM TRAP
PRESSURE SENSOR
INLINE PUMP
SUPPLY DIFFUSER:
SHADING INDICATES BLANKED -OFF
QUADRANT OF DIFFUSION PATTERN
SEE SCHEDULE FOR
RUNOUT SIZE
DIFFUSER TYPE
DIFFUSER SIZE
SD4
750 DIFFUSER CFM
RETURN/EXHAUST GRILLE:
SEE SCHEDULE FOR
RUNOUT SIZE
GRILLE TYPE
Z/ � GRILLE SIZE
RG
750 � � GRILLE CFM
LINEAR BAR & SLOT DIFFUSER:
ARROW INDICATES
DIRECTION OF AIR FLOW
SEE SCHEDULE FOR
RUNOUT SIZE
DIFFUSER TYPE
DIFFUSER SIZE
LDE
220 _DIFFUSER CFM
TERMINAL BOXES
SINGLE -DUCT TERMINAL BOX
(WITH REHEAT COIL)
SEE SCHEDULE SEE SCHEDULE
FOR OUT
SIZE FOR RUNOUT SI
TYPE OF TERMINAL BOX
VAV-1
i
CONTROL PANEL
` MAINTAIN CODE REQUIRED
CLEARANCE IN FRONT OF
CONTROLPANEL
SUPPLY DIFFUSER:
SHADING INDICATES BLANKED -OFF
QUADRANT OF DIFFUSION PATTERN
SEE SCHEDULE FOR
74 RUNOUT SIZE
DIFFUSER TYPE
DIFFUSER SIZE
SD4
750 � DIFFUSERCFM
RETURN/EXHAUST GRILLE:
SEE SCHEDULE FOR
RUNOUT SIZE
I�I GRILLE TYPE
III /LJ• rGRILLE SIZE
RG-B GRILLE CFM
RG f�
LINEAR BAR & SLOT DIFFUSER:
ARROW INDICATES
DIRECTION OF AIR FLOW
SEE SCHEDULE FOR
RUNOUT SIZE
DIFFUSER TYPE
!� DIFFUSER SIZE
LD-6
220 �DIFFUSER CFM
DUAL DUCT TERMINAL BOX:
1 ' 0�/- TYPE OF TERMINAL BOX
`CONTROL PANEL(S)
`MAINTAIN CODE REQUIRED
CLEARANCE IN FRONT OF
CONTROLPANEL
DUCTWORK:
SUPPLYARROW
w� RETURN/EXHAUST ARROW
Q THERMOSTAT
0 HUMIDISTAT
0 SENSOR
I� SUPPLY UP
tI —LLJ7 SUPPLY DOWN
RETURN/EXHAUST UP
�O: RETURN/EXHAUST DOWN
ROUND UP
ROUND DOWN
FLAT OVAL SUPPLY UP
FLAT OVAL SUPPLY DOWN
16X12 RECTANGULAR DUCT
WIDTH x HEIGHT
i6"0 ROUNDDUCT
DIAMETER
i6x120 FLAT OVAL DUCT
WIDTH x HEIGHT
EXISTING DUCT
900 MITERED ELBOW WITH
TURNINGVANES
V=w)
I�r ELBOW
J DUCT END CAP
5° MF+� '
DUCT TRANSITION -
SLOPED BOTH SIDES
5°M
DUCT TRANSITION -
FLAT ON ONE SIDE
FLEXIBLE DUCT
I4AI—I4AI-14JIJI VOLUME DAMPER
t
ED
FIRE DAMPER
itMOTORIZED DAMPER
BDD
BACKDRAFTDAMPER
[]AD ACCESSDOOR
DUCTWORK:
SINGLE REPRESENTATION :
ILIN IE
—IN
I�ZI
SUPPLY UP
!— E]
SUPPLY DOWN
RETURN/EXHAUST UP
ICE]
RETURN/EXHAUST DOWN
ROUND UP
�.. 1
ROUND DOWN
OVAL SUPPLY UP
I 3
OVAL SUPPLY DOWN
f�16X12�
RECTANGULAR DUCT
WIDTH HEIGHT
a 16"0�
ROUND DUCT
DIAMETER
f 16x120�
FLAT OVAL DUCT
WIDTH HEIGHT
s
EXISTING DUCT
f�
1
DUCT TURN 90°
*====,3
DUCTENDCAP
y
DUCT TRANSITION -
SLOPED ON BOTH SIDES
DUCT TRANSITION -
FLAT ON ON E SIDE
ammjlYy
FLEXIBLE DUCT
*...f�
VOLUME BALANCE DAMPER
ED
FIRE DAMPER
MOTORIZED DAMPER
I BDD.
BACKDRAFTDAMPER
2
MECHANICAL ABBREVIATIONS:
ADA
AMERICANS WITH DISABILITIES ACT
AFF
ABOVE FINISHED FLOOR
AEG
ABOVE FINISHED GRADE
AHU
AIR HANDLING UNIT
AD
ACCESS DOOR
BDD
BACK DRAFT DAMPER
BHP
BRAKE HORSEPOWER
BLDG
BUILDING
Boo
BOTTOM OF DUCT
BOB
BOTTOM OF STEEL
BTU
BRITISH THERMAL UNIT
CA
COMPRESSED AIR
CD
CONDENSATE DRAIN
CHWR
CHILLED WATER RETURN
CHWS
CHILLED WATER SUPPLY
CO
CLEANOUT
CR
CONDENSATE RETURN
CS
CASTSINK
CBS
CLINIC SERVICE SINK
CW
DOMESTIC COLD WATER
DB
DRYBULB
DCV
DOUBLE CHECK VALVE
DIA
DIAMETER
DN
DOWN
DWH
DOMESTIC WATER HEATER
EES
EMERGENCY EYE AND SHOWER WASH
EEW
EMERGENCY EYE WASH
EF
EXHAUSTFAN
EG
EXHAUST GRILLE
EL
ELEVATION
ES
EMERGENCYSHOWER
EXIST
EXISTING
GL
GLYCOL
FCU
FAN COIL UNIT
ED
FIRE DAMPER OR FLOOR DRAIN
FDC
FIRE DEPARTMENT CONNECTION
FLA
FULL LOAD AMPS
FOB
FLAT ON BOTTOM
FOT
FLAT ON TOP
AB
HOSE BIBB
HKSP
HOUSEKEEPING
HER
HIGH PRESSURE STEAM RETURN
HPS
HIGH PRESSURE STEAM SUPPLY
HW
DOMESTIC HOT WATER
HWR
DOMESTIC HOT WATER RETURN
HWRP
HOT WATER RECIRCULATION PUMP
HHWR
HEATING HOT WATER RETURN
HEWS
HEATING HOT WATER SUPPLY
IE
INVERT ELEVATION
JS
JANITOR SINK
JT
JOINT
LAV
LAVATORY
LPR
LOW PRESSURE STEAM RETURN
LPS
LOW PRESSURE STEAM SUPPLY
MB
MOP BASIN
ME
MIXING FAUCET
MPR
MEDIUM PRESSURE STEAM RETURN
MPS
MEDIUM PRESSURE STEAM SUPPLY
NC
NORMALLY CLOSED
NO
NORMALLY OPEN
PIV
POST INDICATING VALVE
PRV
PRESSURE RELIEF VALVE
PSIA
POUNDS PER SQUARE INCH ABSOLUTE
PSIG
POUNDS PER SQUARE INCH GAUGE
RE
RETURN FAN
RG
RETURN GRILLE
RO
REVERSE OSMOSIS
RPBP
REDUCED PRESSURE BACKFLOW PREVENTER
SAN
SANITARY
SO
SUPPLY DIFFUSER
SF
SUPPLY FAN
SG
SUPPLY GRILLE
SH
SHOWER
SI
SEDIMENT INTERCEPTOR
SK
SINK
STM
STEAM
TD
TRENCH DRAIN
TMV
THERMOSTATIC MIXING VALVE
TSP
TOTAL STATIC PRESSURE
V
SANITARY VENT
VD
VOLUME DAMPER
VFD
VARIABLE FREQUENCY DRIVE
VTR
VENT THROUGH ROOF
WB
WET BULB
WC
WATER CLOSET
WE
WALL HYDRANT
E
to
C
191
10
SCHMIDT
ASSOCIATES
415 Massachusetts Avenue
Indianapolis, IN 46204
www.schmidt-arch.com
Project No. 2018-101
Project Date 03.22.2019
Produced Designer Author
3/22/19
Applied
Engineering Services
wRGWe[alhiMyXdA{SukID• 1tl4y1'e,w"*ni
TdWM4111•r WV41V-Hq*&amo
These Drawings and Specifications, and all copies
thereof are and shall remain the property and copyright
of the Arch mot. They shall be used only with respect to
this Project and are not to be used on any other Project
or Work without prior written permission from the
Architect.
9919 Towne Road
Carmel, IN 46032
N
KEY PLAN To
Children's Theraplay
Renovation and New
Construction
MECHANICAL SYMBOLS
AND ABBREVIATIONS
M001