HomeMy WebLinkAboutM301 - FIRST FLOOR HVAC PLAN6 5 4 3 2 1
E
w
C
0
I
TERMINATE INTAKE AND
F6T � FIRST FLOOR
THRU ROOF WITH MANUFACTURER SCALE: 1/8"= 1'-0"
RETURNAIRDUCT� APPROVED TERMINATION KITS
UNIT
SWITCH BY SUPPLY / / AR DUCT PVC INTAKE AND FLUE
MANUFACTURER IY /
CORD
ALUMINUM atCAP
HOUSING RNAL
INUM FULLY CASED
POST COOLING COIL
BYIT
FACTURER CONDENSATE TRAP
FLASH AND D CURB
COUNTERFLASH FURNACE CLEAN OUT
TION BOX
PRE-FAB CURB CONDUITURE DO NOT OBSTRUCT �^
FILTERPANEL----,,,[,.
® ,r
LR�I ��REFRIGERANT PIPING
CONSTRUCTION
ON
PROVIDED HOLE JUNCTION BOX UNION
THROUGH ROOF T T T T T AND CONDUIT
rL sL sL sL sL � GAS PIPING, REFER TO
SEE PLANS PLUMBING DRAWINGS
FOR DUCT SIZE
RELEASED FOR CONSTRUCTION .XHAUST FAN DETAIL
ALE: NONE
Subject to compliance with all regulations
of State and Local Codes
City of Cam ed
DATE: 10/30/19
FLEXIBLE CONNECTION (TYPICAL)
BACKDRAFT
DAMPER MOUNT FURNACE ON I8"HIGH
SHEET METAL RETURN AIR PLENUM
GAS SHUT-OFF VALVE TERMINATE CONDENSATE
PIPE OVER FLOOR DRAIN
FULLY INSULATE RETURN AIR
PLENUM WITH RIGID INSULATION
FURNACE INSTALLATION DETAIL
SCALE: NONE
5
GENERAL NOTES:
1. REFER TO PLUMBING DRAWINGS FOR NATURAL GAS PIPING
2
® PLAN NOTES:
1. EXTEND EXHAUST DUCT UP TO ROOF. TERMINATE EXHAUST DUCT INTO 6" ROOF
MOUNTED EXHAUST CAP. FULLY INSULATE DUCT.
2. MOUNT EF-11N CEILING ABOVE CEILING ABOVE TOILET. TIE INTO LIGHT SWITCH
FOR OPERATION.
3. EXTEND A 4"0 DUCT UP TO A ROOF MOUNTED INTAKE CAP WITH BIRDSCREEN FOR
FRESH AIR INTAKE. BALANCE TO AIR QUANTITY INDICATED.
4. PROGRAMMABLE THERMOSTAT.
5. MOUNT OUTDOOR UNITS ON 6" HIGH CONCRETE PAD.
6. RACK VERTICAL REFRIGERANT PIPING TIGHT TO EXTERIOR WALL. SLEEVE AND
SEAL PIPING THRU THE WALL WEATHER TIGHT. EXTEND REFRIGERANT PIPING
OVER CEILING OF ADJACENT ROOM TO THE RESPECTIVE INDOOR DX COILS. FULLY
INSULATE REFRIGERANT SUCTION PIPES AND PROVIDE AN ALUMINUM JACKET
OVER ALL INSULATION EXPOSED OUTDOORS.
T. SPLIT SYSTEM CONTROLLER. PROVIDE ALL INTERCONNECTING WIRING BETWEEN
COMPONENTS.
B. 1/2" COPPER INSULATED CONDENSATE DRAIN THRU EXTERIOR WALL. SEAL
WEATHER TIGHT WITH ELBOW TURNED DOWN.
9. 10x10 UP TO EF-1 ON ROOF.
E
im
C
191
10
SCHMIDT
ASSOCIATES
415 Massachusetts Avenue
Indianapolis, IN 46204
www.schmidt-arch.com
Project No. 2018-106.CTC
Project Date 03.22.2019
Produced Designer Author
3/22/19
Applied
Engineering Services
%n TO WMh,pny sr WZWkm • elaq*,I lnn
rtl LI8N1111 • rs ylBNllp •Hup{Yiamo
These Drawings and Specifications, and all copies
thereof are and shall remain the property and copyright
of the Architect. They shall be used only with respect to
this Project and are not to be used on any other Project
or Work without prior written pmmission from the
Architect.
9919 Towne Road
Carmel, IN 46032
N
KEY PLAN
Children's Theraplay
Renovation and New
Construction
FIRST FLOOR HVAC PLAN
M301