HomeMy WebLinkAboutM301 - FIRST FLOOR HVAC PLAN6 5 4 3 2 1 E w C 0 I TERMINATE INTAKE AND F6T � FIRST FLOOR THRU ROOF WITH MANUFACTURER SCALE: 1/8"= 1'-0" RETURNAIRDUCT� APPROVED TERMINATION KITS UNIT SWITCH BY SUPPLY / / AR DUCT PVC INTAKE AND FLUE MANUFACTURER IY / CORD ALUMINUM atCAP HOUSING RNAL INUM FULLY CASED POST COOLING COIL BYIT FACTURER CONDENSATE TRAP FLASH AND D CURB COUNTERFLASH FURNACE CLEAN OUT TION BOX PRE-FAB CURB CONDUITURE DO NOT OBSTRUCT �^ FILTERPANEL----,,,[,. ® ,r LR�I ��REFRIGERANT PIPING CONSTRUCTION ON PROVIDED HOLE JUNCTION BOX UNION THROUGH ROOF T T T T T AND CONDUIT rL sL sL sL sL � GAS PIPING, REFER TO SEE PLANS PLUMBING DRAWINGS FOR DUCT SIZE RELEASED FOR CONSTRUCTION .XHAUST FAN DETAIL ALE: NONE Subject to compliance with all regulations of State and Local Codes City of Cam ed DATE: 10/30/19 FLEXIBLE CONNECTION (TYPICAL) BACKDRAFT DAMPER MOUNT FURNACE ON I8"HIGH SHEET METAL RETURN AIR PLENUM GAS SHUT-OFF VALVE TERMINATE CONDENSATE PIPE OVER FLOOR DRAIN FULLY INSULATE RETURN AIR PLENUM WITH RIGID INSULATION FURNACE INSTALLATION DETAIL SCALE: NONE 5 GENERAL NOTES: 1. REFER TO PLUMBING DRAWINGS FOR NATURAL GAS PIPING 2 ® PLAN NOTES: 1. EXTEND EXHAUST DUCT UP TO ROOF. TERMINATE EXHAUST DUCT INTO 6" ROOF MOUNTED EXHAUST CAP. FULLY INSULATE DUCT. 2. MOUNT EF-11N CEILING ABOVE CEILING ABOVE TOILET. TIE INTO LIGHT SWITCH FOR OPERATION. 3. EXTEND A 4"0 DUCT UP TO A ROOF MOUNTED INTAKE CAP WITH BIRDSCREEN FOR FRESH AIR INTAKE. BALANCE TO AIR QUANTITY INDICATED. 4. PROGRAMMABLE THERMOSTAT. 5. MOUNT OUTDOOR UNITS ON 6" HIGH CONCRETE PAD. 6. RACK VERTICAL REFRIGERANT PIPING TIGHT TO EXTERIOR WALL. SLEEVE AND SEAL PIPING THRU THE WALL WEATHER TIGHT. EXTEND REFRIGERANT PIPING OVER CEILING OF ADJACENT ROOM TO THE RESPECTIVE INDOOR DX COILS. FULLY INSULATE REFRIGERANT SUCTION PIPES AND PROVIDE AN ALUMINUM JACKET OVER ALL INSULATION EXPOSED OUTDOORS. T. SPLIT SYSTEM CONTROLLER. PROVIDE ALL INTERCONNECTING WIRING BETWEEN COMPONENTS. B. 1/2" COPPER INSULATED CONDENSATE DRAIN THRU EXTERIOR WALL. SEAL WEATHER TIGHT WITH ELBOW TURNED DOWN. 9. 10x10 UP TO EF-1 ON ROOF. E im C 191 10 SCHMIDT ASSOCIATES 415 Massachusetts Avenue Indianapolis, IN 46204 www.schmidt-arch.com Project No. 2018-106.CTC Project Date 03.22.2019 Produced Designer Author 3/22/19 Applied Engineering Services %n TO WMh,pny sr WZWkm • elaq*,I lnn rtl LI8N1111 • rs ylBNllp •Hup{Yiamo These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written pmmission from the Architect. 9919 Towne Road Carmel, IN 46032 N KEY PLAN Children's Theraplay Renovation and New Construction FIRST FLOOR HVAC PLAN M301