HomeMy WebLinkAboutP302 - FIRST FLOOR PLUMBING PLAN6 5 4 3 2 1
E
10
C
A
I
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and meal Codes
City of Cam ed
11"Iaa
DATE: 10/30/19
GENERAL NOTES: ® PLAN NOTES:
FIRST FLOOR PLUMBING PLAN 1. SEE DRAWING P001 FOR PLUMBING 1. WC: 4"W,2"V,1-12"CW, FLOOR MOUNTED, ELONGATED RIM, ADA 161/2"AFF TO
19 SCALE: 118"=V-0" SYMBOLS B ABBREVIATIONS. RIM.
2. SEE DRAWING P501 FOR PLUMBING 2. UR: 2" W, 1-1/2" V, 3/4" CW, WALL MOUNTED ADA 17" AFF TO RIM.
DETAILS. 3. LAV:2"W,1-1/2"V,1/2"CW,1/2"HW, WALL MOUNTED, ADA 34"TO RIM.
3. SEE DRAWING P601 FOR PLUMBING 4. S:2" W, 1-1/2" V, 3/4" CW, 3/4" HW.
F 1 EC H 20 I SCHEDULES. 5. GD: GARBAGE DISPOSER, 1-1/2" W, BADGER 5, 1/2 HP, 120/1/60.
4. SEE DRAWING P701 FOR PLUMBING WASTE 6. DW: HOOK UP DISHWASHER,3/4"HW, CONNECT DISCHARGE TO GD CONNECTION.
ET -1 16 F_2 & VENT ISOMETRICS
7. VB: VALVE BOX FOR WATER TO REFRIGERATOR ICE MAKER, EXTEND 1/2" CW WITH
_ _ _ I _Y5. 2" W SHALL BE SLOPED AT 1/4" PER FOOT. BALL VALVE TO HOOK-UP.
4'FD _ _ 3"&4" SHALL BE SLOPED AT 1/8"PER
8. WH: WALL HYDRANT, FREEZE PROOF WITH VACUUM BREAKER,3/4"CW WITH
RV py HWRP 13 FOOT. SHUT-OFFVALVE, 3/4" HOSE THREAD,+18"AFG.
6. REINVERTREFERENCING
ONLY SHOWN ARE FOR
/; REFERENCING ONLY. INVERT ELEVATIONS 9. HB:HOSE BIBB, INTERIOR WITH VACUUM BREAKER, 3/4"CWWITH SHUT-OFF VALVE,
USED FOR INSTALLATION PURPOSES B 3/4"HOSE THREAD,+12"AFF.
pW I I ARE THE RESPONSIBILITY OF THE 10. WF: WASH FOUNTAIN, 2" W, 1-1/2"V. 3/4" CW, 3/4" HW, FLOOR MOUNTED, ROUGH -IN
11 7 INSTALLING CONTRACTOR, & DETERMINED PER MANUFACTURER'S INSTRUCTIONS.
1 0"F HW 4"FD O I %3/4 HWR BYTHE INSTALLING CONTRACTOR.
11. DWH: DOMESTIC WATER HEATER, 10 GALLON CAPACITY, SHELF MOUNTED,
t I PROVIDE ET-1 EXPANSION TANK. PROVIDE T8P RELIEF VALVE. DISCHARGE FULL
3 I SIZE OVER FLOOR DRAIN THRU AIR GAP.
,I} 1-1/4" HW 12. MB: MOP BASIN, 3" W, 1-1/2"V, 3/4" CW, 3/4" HW, 36'k36" FLOOR MOUNTED.
1114"HW 13. HWRP: HOT WATER RECIRCULATING PUMP, ALL BRONZE CONSTRUCTION, 1/6HP,
2" CW 120/1/60 WITH 120V AOUASTAT.
2 2"G 14. WHA-B: WATER HAMMER ARRESTOR.
BFP-1 & 2 15. AD: ACCESS DOOR, 12N12" MILCOR FOR ACCESS TO WHA.
16. ET: EXPANSION TANK, 2 GALLONS.
17. TMV-1: THERMOSTATIC MIXING VALVE SETAT 12WF, PROVIDE ISOLATION VALVES,
r 27" HEAT TRAP, AND THERMOMETER ON DISCHARGE.
18. EWC-1:2"W,1-1/2"V,1/2"CW. MOUNT TO ADA HEIGHT, 36"AFF.
FIRE PROTECTION u `II
FOR REFERENCE ONLY 19. F-1: GAS FIRED FURNACE. 60 MBH S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS.
20. F-2: GAS FIRED FURNACE. 80 MBH S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS.
21. F-3: GAS FIRED FURNACE. 80 MBH S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS.
2" CW SERVICE 22. F4 GAS FIRED FURNACE. 80 MBH S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS.
23. F-5: GAS FIRED FURNACE. 80 MBH S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS.
24. F-6: GAS FIRED FURNACE. 60 MBH. S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS.
5
0
3
2
1
E
im
C
191
f
SCHMIDT
ASSOCIATES
415 Massachusetts Avenue
Indianapolis, IN 46204
www.schmidt-arch.com
Project No. 2018-106.CTC
Project Date 03.22.2019
Produced Designer Author
3/22/19
Applied
Engineering Services
wnod:r 4141- srWZWm•iwsmiwaw
Td LI8N1111 • r¢y18N11q •Hup{Y+amo
These Drawings and Specifications, and all copies
thereof are and shall remain the property and copyright
of the Architect. They shall be used only with respect to
this Project and are not to be used on any other Project
or Work without prior written permission from the
Architect.
9919 Towne Road
Carmel, IN 46032
N KEY PLAN
Children's Theraplay
Renovation and New
Construction
FIRST FLOOR PLUMBING
PLAN
P302