Loading...
HomeMy WebLinkAboutP302 - FIRST FLOOR PLUMBING PLAN6 5 4 3 2 1 E 10 C A I RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Cam ed 11"Iaa DATE: 10/30/19 GENERAL NOTES: ® PLAN NOTES: FIRST FLOOR PLUMBING PLAN 1. SEE DRAWING P001 FOR PLUMBING 1. WC: 4"W,2"V,1-12"CW, FLOOR MOUNTED, ELONGATED RIM, ADA 161/2"AFF TO 19 SCALE: 118"=V-0" SYMBOLS B ABBREVIATIONS. RIM. 2. SEE DRAWING P501 FOR PLUMBING 2. UR: 2" W, 1-1/2" V, 3/4" CW, WALL MOUNTED ADA 17" AFF TO RIM. DETAILS. 3. LAV:2"W,1-1/2"V,1/2"CW,1/2"HW, WALL MOUNTED, ADA 34"TO RIM. 3. SEE DRAWING P601 FOR PLUMBING 4. S:2" W, 1-1/2" V, 3/4" CW, 3/4" HW. F 1 EC H 20 I SCHEDULES. 5. GD: GARBAGE DISPOSER, 1-1/2" W, BADGER 5, 1/2 HP, 120/1/60. 4. SEE DRAWING P701 FOR PLUMBING WASTE 6. DW: HOOK UP DISHWASHER,3/4"HW, CONNECT DISCHARGE TO GD CONNECTION. ET -1 16 F_2 & VENT ISOMETRICS 7. VB: VALVE BOX FOR WATER TO REFRIGERATOR ICE MAKER, EXTEND 1/2" CW WITH _ _ _ I _Y5. 2" W SHALL BE SLOPED AT 1/4" PER FOOT. BALL VALVE TO HOOK-UP. 4'FD _ _ 3"&4" SHALL BE SLOPED AT 1/8"PER 8. WH: WALL HYDRANT, FREEZE PROOF WITH VACUUM BREAKER,3/4"CW WITH RV py HWRP 13 FOOT. SHUT-OFFVALVE, 3/4" HOSE THREAD,+18"AFG. 6. REINVERTREFERENCING ONLY SHOWN ARE FOR /; REFERENCING ONLY. INVERT ELEVATIONS 9. HB:HOSE BIBB, INTERIOR WITH VACUUM BREAKER, 3/4"CWWITH SHUT-OFF VALVE, USED FOR INSTALLATION PURPOSES B 3/4"HOSE THREAD,+12"AFF. pW I I ARE THE RESPONSIBILITY OF THE 10. WF: WASH FOUNTAIN, 2" W, 1-1/2"V. 3/4" CW, 3/4" HW, FLOOR MOUNTED, ROUGH -IN 11 7 INSTALLING CONTRACTOR, & DETERMINED PER MANUFACTURER'S INSTRUCTIONS. 1 0"F HW 4"FD O I %3/4 HWR BYTHE INSTALLING CONTRACTOR. 11. DWH: DOMESTIC WATER HEATER, 10 GALLON CAPACITY, SHELF MOUNTED, t I PROVIDE ET-1 EXPANSION TANK. PROVIDE T8P RELIEF VALVE. DISCHARGE FULL 3 I SIZE OVER FLOOR DRAIN THRU AIR GAP. ,I} 1-1/4" HW 12. MB: MOP BASIN, 3" W, 1-1/2"V, 3/4" CW, 3/4" HW, 36'k36" FLOOR MOUNTED. 1114"HW 13. HWRP: HOT WATER RECIRCULATING PUMP, ALL BRONZE CONSTRUCTION, 1/6HP, 2" CW 120/1/60 WITH 120V AOUASTAT. 2 2"G 14. WHA-B: WATER HAMMER ARRESTOR. BFP-1 & 2 15. AD: ACCESS DOOR, 12N12" MILCOR FOR ACCESS TO WHA. 16. ET: EXPANSION TANK, 2 GALLONS. 17. TMV-1: THERMOSTATIC MIXING VALVE SETAT 12WF, PROVIDE ISOLATION VALVES, r 27" HEAT TRAP, AND THERMOMETER ON DISCHARGE. 18. EWC-1:2"W,1-1/2"V,1/2"CW. MOUNT TO ADA HEIGHT, 36"AFF. FIRE PROTECTION u `II FOR REFERENCE ONLY 19. F-1: GAS FIRED FURNACE. 60 MBH S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS. 20. F-2: GAS FIRED FURNACE. 80 MBH S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS. 21. F-3: GAS FIRED FURNACE. 80 MBH S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS. 2" CW SERVICE 22. F4 GAS FIRED FURNACE. 80 MBH S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS. 23. F-5: GAS FIRED FURNACE. 80 MBH S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS. 24. F-6: GAS FIRED FURNACE. 60 MBH. S.L. INPUT. 7" W.C. SEE M-SERIES DRAWINGS. 5 0 3 2 1 E im C 191 f SCHMIDT ASSOCIATES 415 Massachusetts Avenue Indianapolis, IN 46204 www.schmidt-arch.com Project No. 2018-106.CTC Project Date 03.22.2019 Produced Designer Author 3/22/19 Applied Engineering Services wnod:r 4141- srWZWm•iwsmiwaw Td LI8N1111 • r¢y18N11q •Hup{Y+amo These Drawings and Specifications, and all copies thereof are and shall remain the property and copyright of the Architect. They shall be used only with respect to this Project and are not to be used on any other Project or Work without prior written permission from the Architect. 9919 Towne Road Carmel, IN 46032 N KEY PLAN Children's Theraplay Renovation and New Construction FIRST FLOOR PLUMBING PLAN P302