Loading...
HomeMy WebLinkAboutSTRUCT - BUILDING CROSS SECTIONS & DETAILSVALLEY FLASH 1 'xis" AT SHEATHING WITH III 7/fG"0 D SHIELD EACH SIDE OF VALLEY ac VALLEY DETAIL 602 SCALE: y" = 1'-0• STEEL ROOF PANELS (NO — THERMAX ON VALLEY ROOF) 2x4 UPRIGHT PURLINSJ @24"o.c. 2xG LEDGER BOARD FASTENED TO TRU55'T5" WITH (2) I Od NAILS @241-o.c. 3-PLY 2xG STUB UP FROM — CENPER OF LVL HEADER - TO SUPPORT TRU55'TS" 2xG 5YP BLOCKING AT TOP 4 BOTTOM OF LVL HEADER- FASTEN OR I Od NAILS @G"o.c. 2x8 T4G STACKED PURLIN5 TERMINATE ON TOP OF TH15 TRUSS TRU55'T5"FASTENED TO COLUMN EXTENSION MAX -RIB STEEL 51DING ON ENTIRE GABLE WALL HORIZONTAL 4k6" CEDAR MEMBERS TO TIE INTO MAIN BLDG T.B.D.) 110'-0' B/ TRU55 —(2) 1 G" LVL BOX HEADER - FASTEN TO COLUMNS W/ (45) I Od NAIL5 FIELD -CUT END Of 107'-2' ,` TRUSS AND FASTEN TO T/ DOOR FRAMEOUT CUSTOM STEEL MANGER THAT 15 MOUNTED TO LVL HEADER 2xG SPACER GIKT5 BELOW LVL BOARDS hLUM STOREFRONT DOOR �R ,ENTRY HEADER DETAIL 602 SCALE:" = 1'-0• RELEASED FOR CONSTRUCTION , ENTRY CANOPY SECTION Subject to compliance with all regulations 602 SCALE: V=1'-W of State and Local Codes City of Camel ((�� `�vmlULlBnrJnwAaL DATE: 10/30/19 TRIM 5ARGE BOARD WITH 5 FLASH 4G STACKED PURLIN5 ii FROM UNDERSIDE NNOPY) .EDAR TRU55 OR PAINTED C STEEL TRUSS PLATES 1 10'-0" :EDAR TRU55 108'-0" CEDAR BEAM ;EDAR DECORATIVE BEAM ;EDAR COLUMN 103'-0" T/ MASONRY FOR MASONRY BASE BRACKET SUPPLIED 4 ,LLED BY FBI 100'-01, dift T/ FOOTING Y 24" CONCRETE FOOTING R TO GC DRAWINGS) dA CANOPY COLUMN DETAIL Pq2 SCALE: Y2" = V-0" 7/`d' 05D APPLIED TO EXISTING END TRUSS TO SEAL ATTIC SPACE FROM ARENA 2xG HORIZONTAL NAILER5 @4'0.c.— FOR SEAMS OF HORIZONTAL 448' SHEETS OF 7XCII 0513 INTERIOR LINER AT VARIOUS TWILLED AREAS OF REMOVED WNDOW5 EXISTING 2x4 PURLIN5 (LAID FLAT) SHALL REMAIN A515 REMOVE EXISTING RAKE TRIM AND RUN NEW ROOF STEEL 4 THERMAX OVER TRANSITION NEW UPRIGHT 2x4 PURLIN5 FASTEN 2xG 5YP LEDGER BOARD INTO EXISTING END TRU55 W/ (2) I Od NAILS @ 1 21PO.L. EXI5TI NG ENDWALL TRU55 SHALL REMAIN CEILING JOISTS @24110.c. I I G'-0" D/ EXISTING TRU55 5' 4 13/�s' IN CEILING JOISTS �2x5 NAILER FOR CEILING JOISTS - FASTEN TO EXISTING COLUMNS W/ (3) 1 Od NAILS @24"o.c. GC TO DETERMINE IF TH15 EXISTING ENDWALL HAS INSULATION OR IF IT NEEDS TO BE PROVIDED/REPLACED �BROOF CONNECTION SECTION !2) 02 SCALE: Y = 1'-0" 602 SCALE: Y = V-0" ROOF PANELS TRIM MAX -RIB STEEL 51DING f ENDWALL TRU55'T " —2xG WIND BRACE (SEE SHEET 300 FOR LOCATIONS) 1 1 5-4'aXd' B/ TRUSS BEAR I NG 2xG 5PF PLATE 2x4 CEILING JOISTS @24"o.c. G"UNFACED BATT INSULATION 2EAST GABLE SECTION fi02 SCALE: )d" = 1'-0" C F a <� z E = W �zc LL a L r = e c i E _ W a _ _ W O �Y aa� a N N J s� O aCt.1 F0 w p Lq o w Y� T J C U Q � aa� s V r: ed DRAWN BY: BILL MTO BY: ENG.BY: ALANS PSC: MABNHEAEe SHEET: 602 Too PROJECT M: 116167