HomeMy WebLinkAboutP300_Water Planr I�------------------------- 11 I, ,I I I � NUMBERED NOTES O1 Connect new domestic cold water in to existing cold piping 9 water piping. Demo existing Verify stub and isolation valve and install new as shown. Verify size and location of existing piping prior to construction. Report any problems to engineer. O2 Provide and install new water sub meter and remote reader. Coordinate remote reader location with landlord. Verify point of connection to existing water main in field. . O3 Install new electric water heater above mop sink. Coordinate support structure with GC. Maintain a minimum 24" working clearance around valves and 36" working clearance in front of control panel. See detail and schedule on Sheet P100 for more information. O4 Provide and install circulation pump and balancing valve on hot water recirc line. See Pump Schedule on Sheet PI for more information. 9 New 2 PSI gas meter and service line. Coordinate all requirements with gas company. 6 Run gas piping on roof. See detail this sheet. ] Route new condensate piping from RTU towards existing to remain storm gutters on rear of building. See detail this sheet for more information. RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes e City of Camel ((�� `1VTl�tlandNaAaL DATE: \\ 10/30/19 1 WATER & GAS PLAN P300 1/4" = 1'0" GAS PIPING TO ROOFTOP UNITS AND CONDENSATE DRAINAGE FROM THE ROOFTOP UNITS SHALL BE INSTALLED BY LANDLORDS CONTRACTOR CONTRACTOR SHALL PROVIDE THE A.H.J. WITH TEST RESULTS FOR THE DOMESTIC WATER SERVICE BACK FLOW PREVENTION DEVICE. (E)2• CW CW "i —i N" HW- t'-CW—I--_— jl jl II I iT II II jl j j------E------- seat eS V w t;J w V S0� sii S0� II II II I P-3 I P-3 I P-2 I P-1 I I I I J L.J L.J L"J LJ WATER RISER P300 NOT TO SCALE Miro Industries 4—RAH-7 pillowblock pipestand. Adjust roller block height to accommodate variations in roof elevation.. 18"x 18"x 1/2" thick roof walkway material for base sheet, "Carey—Tred"or per architectural specifications. — _.—. (E)2" CW —.—. 1" METER T �© -- O ©F Ye HW-- f~I GW1��1►_��Jf'-Cw -t�� II II II I� II II I III Ij Ij Ij I� Ij Ij I Ij �� 1 �a t a a -- - -a� III� II t it it it iI it it i it at ac ae ac n ac Be ac at at ac At n V 2 V S V S V 2 V S V 2 V V •x"X' •x"aR' scjltX' k0: •y.""X.' t4i •y." sii WH I I I I I I I I II II II II II II I II P-3 I P-3 P-3 I P-4 I I P-3 I P-3 I P-1 I P-2 LP LIIIIIII SIP L"J L.J L.J L.J L.J L"J LJ L"J h" 1 )�" RTU-1 ' RTU-2 150 MBH ro_e 80 MBH 3 GAS RISER P300 I:: SCALE Gas pipe Plumber's tape, do not clamp pipe tight. MW GAS PIPE SIZING NOTE MEDIUM PRESSURE GAS PIPE SIZING IS BASED ON 2012 IFGC, TABLE 402.4(5), 2 PSI AND PRESSURE DROP OF 1 PSI AT MAXIMUM EQUIVALENT LENGTH OF 250 FEET. LOW PRESSURE GAS PIPE SIZING IS BASED ON 2012 IFGC, TABLE 402.4(1), 0.25 PSI AND PRESSURE DROP OF 0.3 INCH WATER COLUMN AT MAXIMUM EQUIVALENT LENGTHS AS INDICATED IN GAS REGULATOR SCHEDULE ON SHEET P1. GAS REGULATOR NOTE SECONDARY 2 PSI GAS REGULATORS (MAXITROL 325) SHALL BE APPROVED, AND SHALL BE SUITABLE FOR THE INLET AND OUTLET GAS PRESSURES, WITH CAPACITY FOR LOADS SHOWN, AND PROVIDED WITH ACCESS. REGULATORS INTERIOR TO THE BUILDING SHALL BE EQUIPPED WITH MANUFACTURER'S VENT —LIMITING DEVICE. REGULATORS EXTERIOR TO THE BUILDING SHALL BE PROVIDED WITH MANUFACTURER'S WEATHERPROOF VENT CAP. THERE SHALL BE 2 TEST TEES PER THE INDIANA FUEL GAS CODE: 1) A TEE FITTING SHALL BE INSTALLED WITH ONE OPENING CAPPED OR PLUGGED BETWEEN THE REGULATOR AND ITS UPSTREAM SHUTOFF VALVE. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW CONNECTION OF A PRESSURE MEASURING INSTRUMENT AND TO SERVE AS A SEDIMENT TRAP. 2) A TEE FITTING SHALL BE INSTALLED, WITH ONE OPENING CAPPED OR PLUGGED, NOT LESS THAN 10 PIPE DIAMETERS DOWN STREAM OF THE MP REGULATOR OUTLET. SUCH TEE FITTING SHALL BE POSITIONED TO ALLOW CONNECTION OF A PRESSURE MEASURING INSTRUMENT. ROOF —TOP PACKAGE A/C UNIT UNION UNIT CONDENSATE THREADED PLUG (HAND CONNECTION TIGHT) IN TEE.— 1 3" TO ROOFTOP GUTTER MINIMUM PITCH 1.5" MIN. ROOF INSULATION 1" (25MM) PER 10' (2M) OF LINE. ROOF DECK Support spacing for pipe size: 4"=10' 3"=10' 2-1/2"=to' 2"=10' 1-1/2"=9' 1-1/4"=8' 1"=7' 3/4"=6'. Place base sheets on roofing before gravel, if any. Set blocks free on base sheets. Install gas pipe to allow for expansion and contraction 4 GAS PIPE SUPPORT DETAIL P300 NO SCALE Trap shown for draw —through units ONLY and based on total fan static pressure of 2" W.C., contact engineer if total fan static pressure is over 2" or blow —through units are installed. 4-L C HA CRAIG BENNETT ASSOCIATES ARCHITECTS TENANT MY EYE DR 1950 OLD GALLOWS RD SUITE 520 VIENNA, VIRGINIA 20182 703-847-8899 FAX 866-414-6476 Contact: Suzanne Berardi —Gould 571-455-8191 ARCHITECT: CBA ARCHITECTS, PC 1239 PINE HILL ROAD McLEAN, VIRGINIA 22101 703-847-6900 FAX 847-6955 www.cba—urchiiecis.com Contact: Craig Bennett cbenneit@cba—architecis.com 703-975-2400 MEP ENGINEER: DWYER ENGINEERING 552 FORT EVANS ROAD NE, #200 LEESBURG, VIRGINIA 20176 703-777-5988 FAX 703-439-2588 www.dwyer.com Contact: Brian Davis BDavis@dwyer.com 703-777-5988 EXT. 110 MY EYE DR SHOPPES ON MAIN SOUTHWEST CORNER OF MAIN ST & GRAND AVE CARMEL, INDIANA Permit Comment 10/21/19 f12 Owner Revision 10/07/19 For Permit 07/18/19 For Review 07/03/19 ",p u u urolo ' 4sTEq. No 11 y' STA 0 F iwntl``JR�• lonv19 ode WATER PLAN SHEET P300