Loading...
HomeMy WebLinkAbout5. FLOOR PLAN A100W2 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City N Camel DATE: 10/30/19 OPEN OFFICE 109 COPY AREA 'IiiIIlIlIIl d 3/A500 ` 4/A500 2/A500 BREAK 108 7I.T. LL 107 107 �pp, 3 3/A500 106 OFFICE CLOSING 106 104 DIMENSION PLAN 1 /1= 1'-0" CLOG II STORAGE E 103 101 RECEPTION 100 CLOSING p 102 0'� Q FLOOR PLAN 1/81- 11-Nn LEGEND NEW CONSTRUCTION EXISTING TO REMAIN WALL DOORAND FRAME (SEE DOOR 707 SCHEDULE) O WALL DOOR AND dl FRAME NOTE: IF IN GOOD CONDITION, EXISTING DOORS SALVAGED FROM DEMOLITION CAN BE SUBSTITUTED FOR NEW DOORS. ■ AREA NOT IN CONTRACT AREAOFWORK WALL TYPES GENERAL NOTES 1. UNLESS OTHERWISE NOTED OR KEYED ON FLOOR PLAN, ALL NEW WALLS TO BE TYPE WI. 2. PROVIDE BU ILDING STANDARD WINDOW SHADES THROUGHOUT. 3. PROVIDE BRACING AND FIRE -TREATED BLOCKING AS REQUIRED IN WALLS SUPPORTING CASEWORK, TACKBOARDS/MARKERBOARDS, RESTROOM ACCESSORIES, EQU IPMENT, OR ANY OTHER MISC. ITEM REQUIRING ADDITIONAL SUPPORT. 4. FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEWAND EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO NFPA 10. COORDINATE WITH OWNERILANDLORD ON EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER. 5. PROVIDE BLOCKING AS NEEDED FOR WHITE BOARDS. ALL WHITE BOARDS TO BE INSTALLED AT 60" AFF TO CENTER UNLESS NOTED OTHERWISE. CONFIRM LOCATIONS/ INSTALL HEIGHT WITH TENANT PRIOR TO INSTALLATION. 6. DO NOT SCALE THE DRAWINGS. REFER DISCREPANCIES TO PARALLEL DESIGN GROUP, INC FOR FINAL DECISIONS. 7. ALL DIMENSIONSSHOWN ARE TO FINISHED FACE OF WALL UNLESS NOTED OTHERWISE. DIMENSIONS TO EXISTING WALL ARE SHOWN TO FACE OF EXISTING FINISH. DIMENSIONS DESIGNATED AS "CURB OR "CLEAR" INDICATE A CLEAR DIMENSION FROM FACE OF FINISH TO FACE OF FINISH. NOTE: ALL PLAN DIMENSIONS ARE FROM FACE TO FACE OF FINISHED WALL ALL WALLS ARE TO BE [WI] UNLESS OTHERWISE NOTED. NOT ALL WALL TYPES LISTED BELOW ARE NECESSARILY USED ON THIS PROJECT. REFER TO KEYED NOTES REFLECTED CEILING PLAN FOR CEILING HEIGHTS. STANDARD INSULATED W1 WALL 3-5/8" METAL STUDS AT 16" O.C.; ONE LAYER OF 5/8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO UNDERSIDE OF CEILING. PROVIDE BATT SOUND INSULATION INSIDE WALL AND 2'-0" SOUND INSULATION EACH SIDE OF WALL ABOVE CEILING. WALL TO DECK W2 3-5/8" METAL STUDS AT 16" O.C.; ONE LAYER OF 5/8" TYPE "X" GYPSUM BOARD EACH SIDE; EXTEND WALL TO DECKABOVE. PROVIDE BATT SOUND INSULATION INSIDE WALL. PLUMBING RISER DIA TYPICAL ALL SINGLE LOCATIONS SINK C.O. 9�q�N gSTF B/QC TQ �9sTF GRAM NOT TO SCALE 1 CENTER WALL ON EXISTING EXTERIORWINDOW MULLION. CONTACT PARALLEL DESIGN GROUP W ITH DIMENSION DISCREPANCIES. 2 ALIGN FINISHED WALL SURFACES. PROVIDE SAMETHICKNESS STUDS AS EXISTING WALL AT DOOR INFILLS OR WHERE NEW WALLSARE IN LINE WITH EXISTING WALLS. 3 PROVIDE NEW SEMI -RECESSED FIRE EXTINGUISHER CABINETS.WHERE FIRE EXTINGUISHERS ARE SHOWN ON EXISTING WALLS, PROVIDE WALL HUNG UNITS. PLACEMENT IS FOR GENERAL REFERENCE. ALL EXTINGUISHERS SHALL BE PLACED IN ACCORDANCE WITH NFPA 10. 4 PROVIDE SINGLE BOWL STAINLESS STEEL UNDERMOUNT SINK AND FAUCET. PROVIDE GARBAGE DISPOSAL, LIGHT COMMERCIAL MODEL. SINK- ELKAY, CROSSTOWN OECTRU24179R (STAINLESS STEEL) FAUCET- DELTA, MATEO SINGLE -HANDLE PULL DOWN 09183-AR-DST(ARCTIC STAINLESS FINISH) 5 PROVIDE WATER LINE FOR COFFEE AND REFRIGERATOR. CONFIRM LOCATION WITH TENANT. a 0 9 v Z v IS a OrnEM � �m W u, O OR J O V u 0 n0 a ' A Rd O 9 ^ uED z O a in u i ut a ¢ a � o 0 0 w 00 CA m m Urn o0 �°° 0 cD0 w � u0 l/) m O O D y o N W O L� r O N art 7 C to N 7 O ;_� L _ro Z E � U _ ro LU U A`I W 0 O LL `aN`COLEy "' 0\STE/�F�'YS2� No. 11900087 STATE OF A 'o�gRCHIPS " UFLOOR PLAN A100 IN MATED OR REMMENTED By THEM DMAMNGMARE UMD By OR DISCLOSED TO ANY PERSON, CAN OR FOUR FOR ANY REASON WHAMEWERWIMUT THEW ENTER OONMNT OF NURATEL FRED CRAFT INC CONTRACTORMIALLVEMN AND BE RESPONSIBLE MR ALL MUST BE NOTIFIED OF My DKRE�UNCIESORWAREATIONS FROM THE DIM ENRMR�MFWN AN THE MIAMI