LEGEND
LIGHT FIXTURE, 2'X4',LED
MFG: COOPER LIGHTING
STYLE: 2X4 METALUX LED
MODEL: 24CZ245-UNV-
L835-CD1-U
®
LIGHT FIXTURE, 2'x2', LED
MFG: COOPER LIGHTING
STYLE: 2X2 METALUX LED
MODEL: 22CZ2-39-UNV-
L835-CDI-U
0
RECESSED LIGHT FIXTURE
C1
MFG: CONTECH
MODEL: R2ANC7 hill
UMOD30KF C2302-CLR
0
RECESSED LIGHTFIXTURE
C2
MFG:HALO
MODEL: HC420DO10-
HM412835-41MDCWF
0
RECESSED LIGHTFIXTURE
C3
MFG:HALO
MODEL: HC430DO10-
HM434835-41 WDW
RECESSED LIGHT FIXTURE
D1 MFG: FOCAL POINT
MODEL: FS142AL-FFL-875LF-
35K-1 C-UNV-LDI-G1- WH 6'
FRI o PENDANTFIXTURE
MFG: TECH LIGHTING
MODEL: 18047-G 1-Z HAN E
LINEARSUSPENDED
GENERAL NOTES
® EXITLIGHT
1.
PROVIDE NEW CEILING GRID AND TILE AT 9'-6"AFF THROUGHOUT
FIXTURE
UNLESS NOTED OTHERWISE.
41=1P. EMERGENCY LIGHT
2.
WHERE MULTIPLE SWITCHESARE SHOWN, PROVIDE (1) GANG BOX
FIXTURE
WITH A SINGLE COPPERPLATE.
NL INDICATES NIGHT
3.
PROVIDE EMERGENCY LIGHTING IN TENANTSPACE AS REQUIRED
LIGHTLOCATION
PER NEMA AND IBC. EMERGENCY BATTERY PACKS OR LIGHTS
CONNECTED TO AN EMERGENCY POWER SOURCE ARE REQUIRED
IF THE SPACE CONTAINS 50 PERSONS OR MORE. FIXTURES SHOWN
^ LIGHT Cl RC U IT
ON PLAN ARE FOR REFERENC E ON LY.
b LIGHTSWITCH
4.
LIG HTI RIG PLACEM ENT AND QUANTITI ES ARE FOR REFERENCE
ONLY AND ARE TO BE PROVIDED BY LIGHTING CONSU LTANT AND
53 LIGHTSWITCH,
ELECTRICIAN. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR
3-WAY
VERIFYING THAT LAY -OUT AND TOTAL WATTAGE MEETS ASHRAE
90.1 STANDARDS AND LIGHT LEVELS ARE APPROPRIATE FOR THE
USEOFEACHSPACE. OVER 50%OF THE LIGHTING WILL BE
LIGHTSWITCH,
REPLACED WITH NEW, SO ASHRAE WATTAGE REQUIREMENTS WILL
DIMMER
NEED TO BE MET.
5.
U NLESS NOTED OTHERWISE ALL NEW SWITCHES MUST BE AN
OCCUPANCY SENSOR COMBO UNIT WITH BOTH U LTRASONIC AND
INFRARED TECHNOLOGY WITH A ONE BUTTON OVERRIDE.
OCCUPANCY SENSORS ARE TO BE LOCATED SUCH THAT
OCCUPANCY WITHIN ANY PORTION OF INCLUDED AREA IS
DEFECTED. PROVIDE CEILING MOUNTED OCCUPANCY SENSORS
IN OPEN AREAS AS REQUIRED.
6.
CAN LIGHT FIXTURES TO BE SWITCHED SEPARATELY AND HAVE
DIMMERS.
7.
ALL DEVICES AND COVERS TO BE WHITE.
8.
ALL BULKHEADS TO BE CONSTRUCTED USING METAL STUDS, NOT
CEILING GRID AND WIRE SUPPORTS.
NEW CEILING GRID, NEW GYPSUM BOARD
SUSPENDED, 2'x2' CEILING
CEILING TYPE
CEILING HEIG„�..........
II
A 2'x TACOUSTICAL CEILING
MFG: ARMSTRONG
TYPE: DUNE
EDGE TYPE: REVEAL
GRID: 15/16"
NRC RATING: 0.55
FIRE RATING: CLASSA
■ AREA NOT IN CONTRACT
❑ AREAOFWORK
KEYED NOTES
1 CONTROL OPEN OFFICEAREA LIGHTING WITH 3-WAYSWITCH AT
THIS LOCATION. PROVIDE MULTIPLE SWITCHES AS REQUIRED.
MAXIMUM OF 2,500 SQUARE FEEF PER SWITCH PERASHRAE 90.1.
J"
a 0
>9
v
Z q
Yl
� m�3
J b m
u0 a BIT on
j 0
U �
0 n
a ' A
a
� 0 a
BID
Or
a
0
BE
u
FEE
E
�
O
z
d
�
o
O�
w
F
W
N
11)
5
m
G
m
0
3m
��
Go
g
C
In
m
m
o
O
❑
EL
N
W
will O
0
IIIIIA
+� M
(� O
tD
N At
j C
a- J ro
0PIC
Z
will v ro
LU U
� o
LL
`aN`COLEy
`;gip 0\STE/�F�'YS2�
No. EULSO SI
ZZ
STATE OF
RED CHIA PS"
0`
V'
REFLECTED
CEILING PLAN
A200