HomeMy WebLinkAbout9. POWER AND DATA A300BREAK SEE CO 05REA \ STORAGE 108101 CLOSING O a 103lip / OPEN OFFICE I OFFICE 106 1 z 4 009 %III 17047 CLOSING CLOSING RECEPTION 000 POWER AND DATA PLAN 1/8" =1,_D, RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel DATE: \ 10/30/19 GENERAL NOTES 1. ALL OUTLETSAND COVERSAND SWITCHESAND SWITCHPLATE COVERS TO BE WHITE. 2. AT EACH PHONE/DATAJACK, PROVIDE PULL STRING FROM ABOVE CEILING TO BOX. TENANTS DATA CONTRACTOR IS RESPONSIBLE FOR PULLING CONDUCTORS AND PROVIDING APPROPRIATE TEMINALAT FACE PLATE. 3. ALL ELECTRICAL OUTLETSWITHIN 6'-0" OFWATER ARE TO BE GFI. 4. OWNER TO SUPPLY, INSTALL AND PAY FOR SECUTIRV SYSTEMS (I.E. MAIN SECURITY CONTROL PANEL & MOTION DETECTORS.) MAIN SECURITY CONTROL PANEL TO BE LOCATED IN THE ELECTRICAL ROOM. 5. ALL O UTLETS ARE TO BE INSTALLED 18" MIN. AFF TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTE OTHERSW ISE. 6. REFER TO DOOR SCHEDULE AND COORDINATE WITH TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO ACCOMMODATE ELECTRIC STRIKESAND CARD READERS. ELECTRIC STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE TENANTS SECURITY CONTRACTOR AND ARE TYPICALLY NOT SPECIFIED BY PARALLEL DESIGN GROUP. T. ALL OUTLETSARE TO INSTALLED 18" MIN.A.F.F. TO THE CENTER OF THE DEVICE PER ADA GUIDELINES UNLESS NOTED OTHERWISE. 8. REFERTO DOOR SCHEDULEAND COORDINATEWITH TENANT/OWNER REGARDING JUNCTION BOX LOCATIONS TO ACCOMMODATE ELECTRIC STRIKES AND CARD READERS. ELECTRIC STRIKES AND CARD READERS ARE TYPICALLY INSTALLED BY THE TENANTS SECURITY CONTRACTOR AND ARE TYPICALLY NOT SPECIFIED BY PARALLEL DESIGN GROUP. ■ AREA NOT IN CONTRACT ❑ AREAOFWORK LEGEND 9- POWER OUTLET, DUPLEX POWER OUTLET, QUADRUPLEX JUNCTION BOX CEILING MOUNTED JUNCTION BOX O BOX, BLANK COVER PLATE QO BOX, OPEN P ❑ POWERAND DATA POLE �p FLOO R BOX W ITH J U NCTIO N BOX AND DATA, FLUSH MOUNTED b FLOOR BOX WITH POWERAND DATA, FLUSH MOUNTED DATA/COMMUNICATION OUTLET (PROVIDE BOX AND PULL STRING ONLY) E EXISTING TO REMAIN DIED DEDICATED CIRCUIT GFI GROUND FAULTCIRCUIT INTERRUPT OUTLET +44" HEIGHTOF ELECTRICAL OR DATA DEVICE L' Sl DATA HD HDMI KEY NOTES 1 COPIER RECEPTACLETO BE 208-220V/60HZ/20A. COORDINATE REQUIRED SPEC WITH TENANT. 2 CONFIRM REQUIREMENTS FOR I.T. CLOSET WITH TENANT. 3 PROVIDEJUNCTION BOX AND DATA FORTENANT'S FURNITURE SYSTEM. COORDINATE EXACT LOCATION WITH TENANT'S FURNITURE VENDOR. 4 PROVIDE POWER AND DATA IN THE FLOOR FOR CONFERENCE TABLE THRU CONNECT-TRAC SYSTEM, COORDINATE OUTLET LOCATION WITH TENANT. 5 APPROXIMATE LOCATION OF WALL MOUNTED TELEVISION SUPPLIED BY TENANT. COORDINATE EXACT LOCATION WITH TENANT. 0 0 4� q 9 O w � Z m l7 n ti me3 J O ,p q W O 01 Do J 0 A N. UU 0 > m 6 �09^ m _ z O_ ~ 0 N K � o a � o o � w An 00 011 CA am ?: 0 r� U p O a LI U m O O p O EL N U W 4leiiiiiiiii, O _O N N ��{{ LJ In 7 �V 0 N O C jMID S Z N E �; � V _ ro W U ^, W � O ,� LL `aN`COLEy 0\STE/?F�'YS2� No. 11900087 Go OF STATE OF ZS SEE 11 PS AN �gRCHIA 0` V' POWERAND DATA A300