HomeMy WebLinkAbout2. LIFE SAFETY A001RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�V�I��V'�9*�41WML
DATE: 10/30/19
LEGEND
GENERAL NOTES
1.
PROVIDE EMERGENCY LIGHTING IN TENANT SPACE AS REQUIRED
PERNEMAANDIBC. EMERGENCY BATTERY PACKS OR LIGHTS
Ep
EXISTING ELECTRICAL PANEL LOCATION
CONNECTED TO AN EMERGENCY POWER SOURCEARE
REQUIRED IF THE SPACE CONTAINS 50 PERSONS OR MORE.
FIXTURES SHOWN ON PLAN ARE FOR REFERENCE ONLY.
EX
EXISTING EXIT -BUILDING EXIT LOCATION
2.
PROVIDE ALARM NOTIFICATION APPLIANCES(HORNS/STROBES),
EMERGENCY SPEAKERS, SMOKE DEFECTORS, FIRE PULLS, AND
FE
FIRE EXTINGUISHER
ANY OTHER REQUIRED ALARM& DETECTION SVSTEMSAS
NECESSARY TO MEET ALL APPLICABLE CODES (INTERNATIONAL
BUILDING CODE, INTERNATIONAL FIRE CODE, NFPA).
®
EXIT SIGNAGE
3.
FIRE PROTECTION WORK IS TO BE PROVIDED BY DESIGN/BUILD
,�,
EMERGENCY LIGHTING
SERVICES UNDER THE GENERAL CONTRACT. PROVIDE
EL
COMPLETE, WORKING SYSTEM. PARALLEL DESIGN GROUP, IS NOT
RESPONSIBLE FORTHE DESIGN, INSTALLATION, OR RENOVATION
AIL
NIGHT LIGHT/EMERGENCY LIGHTING,
OF THE FIRE SPRINKLER SYSTEM.
REFRENCE A200 FOR LOCATION.
4.
THE FIRE PROTECTION CONTRACTOR SHALL GENERATE ALL
■
AREA NOT IN CONTRACT
REQUIRED DRAWINGS, AND SHALL FILE THOSE DRAWINGS, AND
RELATED DOCUMENTS, WITH THE STATE AND LOCAL
AUTHORITIES HAVING JURISDICTION OVER THE PROJECT.
❑
AREA OF WORK
5.
FIRE EXTINGUISHERS: CONTRACTOR TO ENSURE ALL NEW AND
EXISTING FIRE EXTINGUISHERS ARE INSTALLED ACCORDING TO
NFPA 10. COORDINATE WITH OWNERILANDLORD ON
EXTINGUISHER TYPE AND HOUSING. MAXIMUM TRAVEL DISTANCE
OF 75 FEET FROM ANY POINT TO A VISIBLE EXTINGUISHER.
6.
REFER TO SHEET Al 00 FOR WALL TYPE AND CONSTRUCTION
DETAILS
7.
EXISTING EXIT SIGNS, FIRE PULLS, FIRE EXTINGUISHERS, ALARM
NOTIFICATION APPLIANCES TO REMAIN.
CODE SUMMARY
SCOPE OF WORK:
OFFICE SPACE BUILD -OUT REMODEL TO PREVIOUSLY BUILT -OUT OFFICE
OCCU FANCY CLASSIFICATION:
B (BUSINESS)
CHANGE OF OCCUPANCY CLASS
NO
TOTAL BUILDING AREA:
±13,620 SF/FLOOR X 2 STORIES = 27,239 GROSS SF
TOTALAREA ON FLOOR:
13,620 SQ.FT.
TOTAL PROJECT AREA:
2,120 SCI
OCCU PANCV CALCULATIONS
SPACE TYPE AREA SFPEROCCUPANT OCCUPLOAD
GENERAL OFFICE 1,425 100 15
CLOSING (CONFERENCE) 583 15 40
STORAGE 112 300 1
TOTAL OCCUPANTS IN PROJECT AREA: 15
NUMBER OF REQUIRED EXITS:
2
SPRINKLER SYSTEM (YES/NO):
NOT EXISTING - NEW SYSTEM BEING INSTALLED IN TENANT SUITE
FIRE WALLS, AND/OR OCCUPANCY SEPARATIONS (IF REQUIRED)
N/A
APPUCABLE CODES:
ALL CONSTRUCTION SHALL COMPLY WITH THE FOLLOWING
BUILDING CODE
2014 INDIANA BUILDING CODE (2012 IBC WITH STATE AMENDMENTS)
STRUCTURAL CODE
2008 INDIANA BUILDING (20061BC, ASCE-7-2005)
PLUMBING CODE
2012 INDIANA PLUMBING CODE
MECHANICAL CODE
2014 INDIANA MECHANICAL CODE (20121MC WITH STATE AMENDMENTS)
ELECTRICAL CODE
2009 INDIANA ELECTRICAL CODE (2008 NEC WITH AMENDMENTS)
FIRE/LIFE SAFETY CODE
2014 INDIANA FIRE CODE (2012 IFC WITH STATE AMENDMENTS)
ACCESSIBILITY CODE
2014 INDIANA BUILDING CODE, CHI I -ACCESSIBILITY, ANSI A-117.1 STANDARD,
ADA ACCESSIBILITY GUIDELINES - 2009 EDITION
ENERGY CODE
2010 INDIANA ENERGY CONSERVATION CODE (ASHRAE 90.1-2007) WITH
INDIANA AMMENDMENTS
GENERAL ADMINISTRATIVE RULES 2ND EDITION.
LIFE SAFETY PLAN
1/811
9
v
Z d b
Y >
� mARE3
J 5i AA0 q
jW OR
0 AIRO
z Y
u
0
6 Vim^
9
on ^
on _
z
O
ti
a
0
¢
FEE
U
q
E
z
So
a
�
o
a
a
o
a
PER
00
�
N
m
So
0)
3m
u
CIO4a
o0
O
LA
��
m
ED
O
a
u
SEE a
N
W
4=J O
O
N
_
M
7 0
TV
C N ko
O
jC
Bill
C �
S
N
Z
E NAS
�U
eiiiiiiiii,_ ro
w U
O
LL
AN LEy
egF,eY`P2,
SO
OH 8]BE
c
LEd____J1
ZZ
RO OF
PS 11
0` "
co
ictIFFEENEI
LIFE SAFETY
A001
IN MATEDORREMEMENTED By THESE DRA ARM ABU
OWNED By PARENTELDMGN GICUR INC ANDSHATNOT BE
USED By OR DISCLOSED TO My ENRON RAN OR COMES FOR
AM REASON NHATSAOEAM WITHOUT THEW BITTER CONSENT
OF PARAPTEL SPEND GAND UP INC
CONTRACTORS SHEALLVEND AND BE RESPONSIBLE MR ALL
IN MEN SOUP ON THEDOBEFTE PARAUEL ASEAN GROUP INC
ED a BE NOTIFIED OF My DISCREPANCIES OR VA RATIONS
MOM THE DIM ENS IONS SHOWN ON THE PLAS