Loading...
HomeMy WebLinkAboutSpecs and Detailsr-----------------a-----------------D c B A NOTICE Tl11S DOCUMENT CONTAINS INFORMATION WHICH IS BOTH CONFIDENTIAL HID PROPRIETARY 10 CAPSTONE TURBINE COAPOAATION. NEITHER THIS DOCUMENT NOR THE INFORMATlON CONTAINED HEREIN 8HAI.l. BE COPIED, DISCLOSED 10 OTHERS OR USED FOR ANY OTHER PURPOSES BEYOND THE SPEQFIC PURPOSE FOR WHICH THIS DOCUMENT WNJ DEUVERED WITHOUT THE EXPRESS WltTTBI PERMISSION OF CAPSTONE TURBINE CORPORATION. 20112 CAPSTONE T\JABINE CORPORATION -AU. RIGifTS RESERVED NO UNLESS OTHERWISE SPECIFIED INTERPRET DRAWING PER ANSI Y14.5M-1982. 2 ALL DIMENSIONS ARE IN INCHES. • FRONT, SIDE AND REAR CLEARANCES SHOULD BE PROVIDED FOR SERVICE ACCESS. LOCAL ELECTRICAL CODES SHALL PRESCRIBE MINIMAL REAR CLEARANCE FOR ACCESS TO JUNCTION BOX. 4 MOUNT LEVEL WITHIN 2% GRADE. SURFACE MUST DRAIN TO PREVENT STANDING WATER. 5 REFER TO PRODUCT CATALOG FOR OPTIONAL ACCESSORIES. 6 REFER TO CAPSTONE MICROTURBINE FUEL TECHNICAL REFERENCE MANUAL410002. 0 UFT UNIT WITH AVE INCH WIDE FORK UFT BLADES. m FOR OVERHEAD LIFTING OF UNIT; STRAPS SHALl. NOT EXCEED 30" FROM VERTICAL. ~ THIS APPUES TO DUAL MODE OR STAND ALONE SYSTEMS. ~ THIS APPLIES TO GRID CONNECT SYSTEMS. 11 ADDmONAL PRODUCT SPECIFICATION INFORMATION IS CONTAINED IN THE PRODUCT SPECIFICATION 460000. 12 ADDmONAL ELECTRICAL INFORMATION IS CONTAINED IN THE C30 ELECTRICAL TECHNICAL REFERENCE 410000. 13 ADDmONAL PERFORMANCE INFORMATION IS CONTAINED IN THE PERFORMANCE TECHNICAL REFERENCE 410004. ~ HAND TIGHTEN UFTlNG EVE AND TIGHTEN ADDmONAL 3/4 TO 1 TIJRN TO SECURE LIFTlNG PARALl.EL wm-l LONG SIDE OF UNIT. ~ ROOF IS A 'NO STEP" ZONE. 7 4X 1.60 IN LIFTING EYE INTERFACE DISPLAY PANEL (UNDER COVER) ENGINE COMBUSTION AIR INLET FILTER ACCESS ELECTRONICS VENTILATION AIR INLET FORWARD PALLET JACK OPENING 6 ENGINE EXHAUST 6 4 3 SIDE PALLET JACK OPENING ---------------2------------------------------------1---------------~ USER ENCLOSURE EXHAUST REAR ACOUSTIC ATTENUATION HOOD ENCLOSURE EXHAUST REVISIONS LTR DESCRIPTION DATE APPROVED A PRODUCTION RELEASE ~7 D.RESH B 0&1 STANDARDIZATION 06/09/11 P. BREAULT C PER CM-105086 07/24/12 P. BREAULT WEIGHTS DUAL MODE 11271 LBS I 578 KG GRID CONNECT! 891 LBS I 405 KG LUGS SIZES/ELECTRICAL CONNECTIONS WIRE SIZE TORQUE HIGH 2/0 TO #6 AWG 120 IN LBS POWER 62 TD 13 mm2 1 .38 KG-M NEUTRAL TO 30 IN LBS CONNECT! ON BAY (ON BACK) GROUND 0.34 KG-M FUELS FUEL INLET MODES DM GC LPNG X 37'FLARE AN-12 (3/4' AND 1/2' FEMALE NPT ADAPTER-LOOSE SHIPPED) X HPNG 37'FLARE AN-12 (3/4' AND 1/2' FEMALE NPT ADAPTER-LOOSE SHIPPED) X X LIQUID 37.FLARE AN-6* X X 37.FLARE AN-12 X X PROPANE (3/4' AND 1!2" FEMALE NPT ADAPTER-LOOSE SHIPPED) LANDFILL 3/4' FEMALE NPT X (TYPE A) (1 /2' NPT ADAPTER LOOSE SHIPPED) DIGESTER 3/4' FEMALE NPT X (TYPE B) (1 /2' NPT ADAPTER LOOSE SHIPPED) [I] HPSG 3/4' FEMALE NPT X X (1/2' NPT ADAPTER LOOSE SHIPPED) *SEE NEXT PAGE FOR DRAIN SIZE ~ Capstone Turbine Corporation :11.. Clpllnl 21E11IfJIIDf«lFFSIIEET "7JJI" av<11MDHIH,CA.,011 0&1, C30, IND PKG 518834 ~ c D c B A COPY IS UNCONTROLLED; USER IS RESPONSIBLE TO VERIFY CURRENT REVISION 4 3 _________________ 1 _______________ ___j r-----------------a-----------------7 6 D c B A NOTICE TliiS DOWMENT CONTAINS INFOAIIIAOON WHICH IS BOTH CONFIDEN'TIN.. AND PROPRIETARY TO CAPSTONE lURBINE CORPOAAliON. NEITHER lHIS DOCUMENT NORlHE INFQAMATION CONTAINED HEREIN SHALl. BE COPIED, DISCLOSED TO OTHERS OR USED FOR ANf OTHER PURPOSES BE'I'OND lHE SPECIFIC PURPOSE FOR WHICH lHIS DOCUMENT WNJ DB.NERED WTTHOU'T Tl1E EXPRESS WRTT9j PERMISSION OF CAPSTONE lURBINE CORPORATION. 2002 CAPSTONE lURBINECORPORATION -AU. RIGif!S RESER'IIED 30 00 1762.0]'---~~ -15.00 -----j !381 .oJ I ~-------+-------.-11 1-1 ll DISPLAY ACCESS PANEL :~r--. •l ENGINE COMBUSTil~~ -ACCESS ~ [766.71 AIR INLET FILTER [~i~~~~~~-~~J 30.19 • • 77.23 [1961.6] ELECTRONIC~ ____ VENTILATION ~~ AIR INLET I ~ CENTER OF------'-·~:::s::::::::::::::::::::::::::::r GRAVITT ---..., ----t~~~i~~ [g . -II F ------~1~~i~§ CENTER 0 _______.-GRAVITY ~ 36.46 1926.1] ....,..,-..,....-, --+-----.,-,-.......-'----8.oo I [203.2] I-----l 8.00 -[203.2] 27.85 [707.5] 9 08 1230.11 11.73 1298.0] 4.88 2 IB 32.0] 2.56 J [65.0] 5.69 1144.41 -3.01,-[76.4] 5 26.09 [662.8] 59.67 11515.5) 5.00 [127.0] ENTER OF GRAVITY [g I ENTER OF GRAVITY ~ 4 25.00 1------[635.0]'---~ I ·+-++ . ·++ 52.97 11345.4] 37 00 [939.8] 31.65 1803.8] . 43.74 11111.0] 49.10 [1247.1] I 1+~+-f . , . I++~H~ 3 ---------------2------------------------------------1---------------, 3i' NAX 1·1/2' I.D. LIFTING EYE 2400 lba LIMIT EACH OOLING AIR EXHAUST (TOP & BOTTOM) 'j ---------------=.. ...... 6.66 TURBINE ~HAUST FLAPPER 0146.0 I 5. 751 O.D. /lOAD ON XHAUST NOT TO EXCEED 25 I ba [1L]rJ~ .... =::::5;:;=3:==----~ 37.50 1952.51 70.53 11791.5) POWER CONNECTION BAY I I f--..... 0 0 0 ~ ~ 13.31 17.46 1443.51 DRAIN (LIQUID ONLY l 1/4" FEMALE NPT FUEL INLET !SEE TABLE! &X 9} . 88 MOUNTING HOLES 122. 4l 10.87 [276.0] ONNUNICATIONS BAY 30.42 [772.7] VENT (LIQUID ONLY) 4.90 [124.5] 8.40 [213.4] 5.34 [135.71 518834 D c B A COPY IS UNCONTROLLED; USER IS RESPONSIBLE TO VERIFY CURRENT REVISION 4 3 _________________ 1 _______________ ___j r-----------------a-----------------D c B A NOTICE Tl11S DOCUMENT CONTAINS INFORMATION WHICH IS BOTH CONFIDENTIAL HID PROPRIETARY 10 CAPSTONE TURBINE COAPOAATION. NEITHER THIS DOCUMENT NOR THE INFORMATlON CONTAINED HEREIN 8HAI.l. BE COPIED, DISCLOSED 10 OTHERS OR USED FOR ANY OTHER PURPOSES BEYOND THE SPEQFIC PURPOSE FOR WHICH THIS DOCUMENT WNJ DEUVERED WITHOUT THE EXPRESS WltTTBI PERMISSION OF CAPSTONE TURBINE CORPORATION. 20112 CAPSTONE T\JABINE CORPORATION -AU. RIGifTS RESERVED 7 30.00 [762.1] 30.00 [762.1] 36.68 [931 .6] 6 6 65.13 [1400.4] 4 SERVICE CLEARANCES ~ REQUIRED FOR ROUTINE MAINTENANCE REQUIRED FOR OVERHAUL MAINTENANCE 3 35.31 [896.9] COPY IS UNCONTROLLED; USER IS RESPONSIBLE TO VERIFY CURRENT REVISION 3 ---------------2------------------------------------1---------------~ 30.00 [762.1] D c B A 518834 c _________________ 1 _______________ ___j