Loading...
HomeMy WebLinkAboutA101 Architectural PlansDE 1 /8" 0 WAITING/DISPLAY LT-102 101 42° AfF EXIST. EXAM 1 J�1� AL03� 105 w m o <' a EXIST. EXAM 2 y30y �= 106 WORK 121 EXIST. TEST REXIST, 118 TEST 30- AFT 4 -6 119 O PASSAGE 118 117 PASSAGE 116 EXAM4 DILATING n4 toe w Q H H o PRE -TEST 113 FLOOR PLAN 1/81,= 1'-0" RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Cannel ��1X�3LT EXIST. EXAM 3 107 EXAM 5 109 LJ 110 EXAM 6 110 FSULT.12 STORAGE WALL TYPE LEGEND EXIST STAIRS EXISTING PARTITION TO BE REMOVED 0 EXISTING PARTITION TO REMAIN — NEW WALLS TO THE DECK 3-5/8" 20 GA. METAL STUDS 0 24" O.C. TO DECK W/ 5/8" TYPE 'X' GYPSUM WALLBOARD TO DECK. PROVIDE 3-1/2" FIBER GLASS SOUND INSULATION IN WALL CAVITY. NEW INSULATED PARTITION 3-5/8" 20 GA. METAL STUDS 0 24" O.C. & 5/8' TYPE SX GYPSUM WALLBOARD TO FINISHED CEIt1NG BOTH SIDES. PROVIDE 3-1/2" FIBER GLASS SOUND INSULATION IN WALL CAVITY & 0 CEILING B-O' EITHER SIDE. LOW HEIGHT PARTITION 3-5/8" 20 GA. METAL STUDS 0 24" O.C. W/ 5/8" GYPSUM WALLBOARD BOTH SIDES TO HEIGHT NOTED ON PLAN. NOTE: ALL GYPSUM BOARD SHALL BE TAPED AND SPACKLED FULL HEIGHT. SAND TO CEILING LINE. PREPARE FOR PAINT/WALLCOVERING. a— / /r i H " ,� c]--a un UP 11 E%IST. l I u I I I' RESTROOM I I I I IL I F l� — l� F 4 ♦ —FY I CEILING DEM. PLAN WAITING/DISPLAY 101 EXIST. RESTROOM FIXTURE PLAN 1 /8" = 1'-0" FIXTURE LEGEND ITEM DESCRIPTION REMARKS 1 EXISTING S.S. SINK - RELOCATED BUILDING STANDARD 2 25" D. LAMINATE WORK SURFACE 0 30" A.F.F. W/ 4" BACKSPLASH SEE FINISH PLAN 3 RELOCATED CABINETRY - BASE CABINETS AND UPPER CABINETS PROVIDE NEW END PANELS AS NECESSARY SEE FINISH PLAN 4 LAMINATE UPPER WALL CABINETS SEE FINISH PLAN 5 12" D. LAMINATE TRANSACTION TOP ® 42" ARE BUILDING STANDARD 6 25" D. X 24" W. LAM. COUNTER TOP 0 3C A.F.F. SUPPORT BRACKETS TO BE PERPENDICULAR TO BASE BUILDING STANDARD 7 LAMINATE COUNTER TOP 0 36" ARE BUILDING STANDARD 8 LAMINATE COUNTER TOP Ab 34" ARE BUILDING STANDARD EXIST. STAIRS LAB i 103 EXIST. 3 EXAM 1 6 105 � I I <^ EXEXIST. AM2 6 2 u 06 RECEPT. ORK VFT [ 102 121 EXIST. EXAM 3 6 4 107 TEST TEST 119 EXIST 118 STAIRS iAGE DILATING V 108 PASSAGE 116 EXAM 4 11114 EIn TES13 \/ C / % XAM E 09 5 6 CONSULT. EX ,� „11AM0 6 STORAGE 11 DEMOLITION PLAN KEYNOTES ❑I REMOVE STUD WALL IN ITS ENTIRETY REMOVE EXISTING DOOR, FRAME & HARDWARE IN THEIR ENTIRETY RE -USE AS POSSIBLE IN NEW PLAN ETI REMOVE EXISTING LAMINATE COUNTER/TRANSACTION TOP/WORK SURFACE IN ITS ENTIRETY 4❑ REMOVE EXISTING SINK AND CAP OFF PLUMBING - RE -USE SINKS El REMOVE EXISTING EXAM ROOM CABINETRY AND RE -USE IN NEW FLOOR PLAN 6❑ REMOVE EXISTING FLOORCOVERING IN ITS ENTIRETY. 7❑ REMOVE EXISTING VINYL BASE IN ITS ENTIRETY. OREMOVE EXISTING VINYL WALLCOVERING IN ITS ENTIRETY. ❑g REMOVE EXISTING MINI BLINDS IN THEIR ENTIRETY. APPROX. ELEVATION OF ACOUST. CEILING SCOPE DOCUMENTS THE DOCUMENTS ARE INTENDED TO INDICATE THE GENERAL SCOPE OF THE PROJECT IN TERMS OF DESIGN CONCEPT, DIMENSIONS, AND MAJOR ARCHITECTURAL ELEMENTS. THESE DOCUMENTS DO NOT NECESSARILY DESCRIBE OR INDICATE ALL WORK REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT. ON THE BASIS OF THE GENERAL SCOPE INDICATED OR DESCRIBED, EACH TRADE CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR THE PROPER EXECUTION AND COMPLETION OF THIS WORK. GENERAL NOTES 1. THE DRAWINGS AND SPECS. ARE AN INSTRUMENT OF SERVICE AND ARE THE SOLE PROPERTY OF THE DESIGNER. ANY RE -USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE DESIGNER. 2. THE DRAWINGS AND SPECS. ARE THE SOLE PROPERTY OF THE OWNER. ANY RE -USE OR DUPLICATION OF THESE DOCUMENTS IS PROHIBITED WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE OWNER. 3. ALL WORK SHALL BE PERFORMED IN STRICT COMPLIANCE WITH ALL APPLICABLE CODES, LAWS, AND ORDINANCES. 4. VERIFY ALL EXISTING CONDITIONS PRIOR TO START OF CONSTRUCTION. NOTIFY DESIGNER IMMEDIATELY OF CONFLICTS PRIOR TO PROCEEDING. 5. EACH CONTRACTOR SHALL SCRUTINIZE ALL DRAWING SHEETS TO DETERMINE FULL EXTENT OF RESPONSIBILITIES FOR EACH RESPECTIVE TRADE. 6, EACH CONTRACTOR SHALL PROVIDE ALL BARRICADES, ETC. AS REQUIRED BY LAW, CODE OR ORDINANCE AND AS OTHERWISE REQUIRED. 7, EACH CONTRACTOR IS REQUIRED TO REMOVE ALL CARTONS, BOXES, MATERIALS, TRASH AND DEBRIS CAUSED BY HIS WORK FROM THE JOB SITE DAILY. 8. ALL MATERIALS SUSPENDED FROM STRUCTURE ABOVE SHALL BE HUNG FROM THE TOP CHORD OF THE JOIST THIS INCLUDES BUT IS NOT LIMITED TO BULKHEADS, SPRINKLER LINES, CEILINGS, GAS PIPING, STORM WATER, ELECTRICAL CONDUIT, ETC. 9. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL REQUIRED PERMITS AND THE PAYING OF ALL REQUIRED FEES. 10, ALL DIMENSIONS ARE FROM FACE OF DRYWALL TO FACE OF DRYWALL. 11. ALL INTERIOR FINISHES SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 12. ADA - TENANT BUILD OUT DESIGN HAS BEEN BASED UPON OUR TRAINING AND UNDERSTANDING OF THE REGULATIONS AND GUIDEUNES ISSUED AS COMPONENT PARTS TO TITLE III OF THE AMERICANS WITH DISABILITIES ACT, PUBLIC LAW 101-336. DESIGN RESOLUTION DOES NOT ATTEMPT TO ADDRESS POTENTIAL CONCERNS ASSOCIATES WITH OTHER TITLES OF THE ACT THAT IMPLICATE POLICY, PROCEDURES, AND TELECOMMUNICATIONS ISSUES, 13. ALL EXIT DOOR LOCKS SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES OF THE LATEST ADOPTION. 14. DOOR CLOSERS AT INTERIOR DOORS SHALL BE ADJUSTED SO THAT THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN A DOOR SHALL NOT EXCEED 5 LEIS. 15. INTERIOR DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 70 DEGREES, THE DOOR WILL TAKE AT LEAST 3 SECONDS TO MOVE TO A POINT 3 IN. FROM THE LATCH TO THE LEADING EDGE OF THE DOOR. 16. PREPARE ALL EXISTING WALLS AND FLOORS TO RECEIVE NEW FINISHES. PATCH AND REPAIR AS REQUIRED. 17. G.C. TO LABEL ALL RATED WALLS ABOVE CEILING. FIXTURE NOTES 1. PROVIDE FIRE TREATED WOOD OR METAL BLOCKING FOR FIXTURES AS REQUIRED. 2, G.C. TO SUPPLY AND INSTALL ALL FIXTURES LISTED ABOVE U.N.O. 3. ALL FIXTURES USTED ABOVE SHALL BE "BUILDING STANDARD'. VERIFY TYPE, COLOR, & MANUFACTURER W/ OWNER. 4. MILLWORK CONTRACTOR TO PROVIDE SHOP DRAWINGS FOR ALL CABINETRY FOR TENANT APPROVAL. 5- ALL FAUCETS TO BE ADA COMPLIANT. (WRIST BLADE OR SINGLE ACTION FAUCETS) 6. G.C. TO PROVIDE & INSTALL ANTI SCALD DEVICE EQUAL TO SYMMONS TEMPCONTROL THERMOSTATIC MIXING VALVE - #5-400, #5-500, #5-700, #5-900 OR (15-1000 (DEPENDING ON THE SIZE REQUIRED). 7. ALL EXPOSED OUTSIDE CORNERS OF COUNTERTOPS SHALL BE RADIUSED. 8, INSTALL 2" BLACK GROMMETS FOR EVERY 3 LF OF WORKSURFACE, BUT NO LESS THAN ONE PER TOP. VERIFY EXACT LOCATION WITH TENANT PRIOR TO INSTALLATION. 9, ALL WOODWORK/MILLWORK SHALL CONFORM TO THE QUALITY STANDARDS OF ARCHITECTURAL WOODWORK INSTITUTE (AND PREMIUM GRADE. FABRICATOR SHALL BE FAMILIAR WITH AWI STANDARDS. 10, FABRICATE WOODWORK/MILLWORK ITEMS TO ACTUAL FIELD DIMENSIONS. CONTRACTOR($) SHALL SUBMIT FOR APPROVAL - SHOP DRAWINGS, SAMPLES AND/OR MANUFACTURER'S LITERATURE FOR ALL ITEMS. SHOP DRAWINGS SHALL SHOW SUFFICIENT DETAIL TO DETERMINE COMPLIANCE WITH QUALITY STANDARDS AND DESIGN INTENT. 11, PROVIDE ALL NECESSARY FURRING AND GROUNDS FOR WOODWORK AND FINISH ITEMS. COORDINATE LOCATIONS OF BLOCKING WITHIN PARTITIONS FOR ITEMS TO BE SECURED TO SURFACE. ALL FASTENERS SHALL BE CONCEALED. ,. FROVI^L N Rn rYIRPIFR IIARD4 IO A'I ( 1 1OFCORNERS. FLOOR PLAN KEYNOTES OALIGN NEW WALL WITH EDGE OF EXISTING WALL OR COLUMN 5/8" TYPE "%" GYP. BRD. JF BOTH SIDES OVER 3 5/8" O CLEAN AND CLOSE BLINDS AND DRYWALL OVER EXISTING WINDOW MET& STUDS OPROVIDE NEW ROLLER SHADES TO EXISTING WINDOWS LOCK LEGEND NOTE: ALL HARDWARE TO BE BUILDING STANDARD. DOOR OPERATION TO BE LEVER TYPE. GRAD 2 CYLINDRICAL LOCKSETS ARE TO BE USED. ADA COMPUANT WALL SECTION L1 - BARN DOOR HARDWARE L2 - PASSAGE SET N.T.S. SPECIAL PLUMBING NOTES THE PLUMBING DRAWINGS CONTAINED HEREIN ARE SCHEMATIC IN NATURE AND SERVE ONLY TO CONVEY THE "INTENT" OF THE TENANT'S REQUIREMENTS. IT IS THE RESPONSIBILITY OF THE DESIGN/BUILD CONTRACTORS TO FULLY ENGINEER THESE SYSTEMS. SIGNED AND SEALED DRAWINGS ARE REQUIRED. • THE PLUMBING CONTRACTOR SHALL FURNISH & INSTALL ALL NECESSARY PIPING, FIXTURES, AND OTHER COMPONENTS IN COMPLETE COMPLIANCE WITH ALL CURRENT FEDERAL, STATE AND LOCAL CODES AND ORDINANCES. • ALL NEW AND EXISTING HOT WATER LINES SHALL BE INSULATED. • ALL NEW AND EXISTING PVC OVERHEAD PIPING ABOVE THE CEILINGS SHALL BE WRAPPED WITH "FIRE TAPE". • G.C. TO PROVIDE & INSTALL ANTI SCALD DEVICE. THE TMV IS A LAWLER #84008-61-25 OR APPROVED EQUAL BY LEONARD, SYMMONS OR BRADLEY. GRAMMAN DESIGN, LLC epaw planningI nleriorda gn 8118 SEQUOIA COURT INDIANAPOLIS, IN T624D jsgramman@aU net 317 752.9520 /9 Architectural Solutions Consulting 911 Raeall,d P4m c.�.1 Im�i�meemz 'LLU li IIIVA B44 a LLB W W NJ L 1_ Q 0 0 Q J Q 0 U °a Go W DO LU ? wo as 2 w z za (� a Q o Q& Joz — O_ I oa ml tomlCam 00 o�lWM M DOOR SCHEDULE* DOORS • FRAMES : RPAINT E-EXISTING SEE FINISH PLAN NO. I DOOR FRAME HARDWARE REMARKS SIZE I MAPL ITYPE JMATTJ TYPTICLOSER1 LOCK I STOP KEY PLAN C1 NOT TO SCALE 0 a U N 0 r W X C: A101 PLANS I DATE: -1 WOW -1`J