HomeMy WebLinkAboutM0.1 Shell MechanicalABBREVIATIONS HVAC SYMBOLS A AMP, AMPERE TO INSIDE DIAMETER ABV ABOVE IE INVERT ELEVATION A/C AIR CONDITIONER, AIR CONDITIONING, IN INCH, INCHES ABOVE CEILING IN WC INCHES OF WATER COLUMN SUPPLY AIR DIFFUSER - SHADING INDICATES ACC AIR COOLED CHILLER PATTERN. NO PATTERN SHOWN EQUALS 4-WAY ACCU AIR COOLED CONDENSING UNIT GA KILOVOLT.PMRS OR AS NOTED ADJ ADJUSTABLE 0 KILOWATTS AFC ABOVE FINISHED CEILING KMH KILOWATT-HOUR RETURN OR EXHAUST AIR GRILLE AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE L INTERNALLY LINED AL ACOUSTIC LINING LAT LEAVING AIR TEMPERATURE ROUND DUCTWORK. DIAMETER IN INCHES ANSI AMERICAN iSTANDARDS INSTITUTE 1 # POUNDS All AIR PRESSURE PROP LW LEAVING DRY BULB ARCH ARCHITECT, ARCHITECTURAL LP LOW PRESSURE 20112 RECTANGULAR DUCTWORK. SIZE IN INCHES, AN AIR CONDITIONING & REFRIG INSTITUTE iLOCKED ROTOR AMPS FIRST NUMBER IS SIDE GROWN ASHRAE AMERICAN SOCIETY OF HEATING, LTG LIGHTING REFRIGERATION & AC ENGINEERS LWB LEAVING WET BULB ASME AMERICAN SOCIETY OF MECHANICAL ENGRS UNT LEAVING WATER TEMPERATURE %%/%XL_ INTERNALLY LINED DUCT ABBY ASSEMBLY AMERICAN SOCIETY OF TESTING & MATLB MAX MAXIMUM AUX AUXILIARY MEN!1CO0 NC BTU PER HOUR MECHANICAL CONTRACTOR ® SUPPLY OR OUTSIDE AIR DUCT AND AMERICAN WIRE GAUGE MCA MINIMUM CIRCUIT AMPACITY AWS AMERICAN WELDING SOCIETY MCC MOTOR CONTROL CENTER RETURN, RELIEF OR EXHAUST AIR DUCT AWNA AMERICAN WATER WORKS ASSOC. NO MECH MOTORIZED DAMPER MECHANICAL DIFFUSER/GRILLE LABEL: B/F BELOW FLOOR BAS BUILDING AUTOMATION SYSTEM li MANUFACTURER BOD BAMDRAFT DAMPER MH MANHOLE, METAL HALIDE q B A - TYPE/DESIGNATION SIR BOILER FEED WATER MIN MINIMUM B - NECK SIZE (INCHES) BLDG BUILDING MOCP MAXIMUM OVER CURRENT PROTECTION C C - AIRFLOW (OR) Bill BUILDING MANAGEMENT SYSTEM MTU MOUNTED BOD BOTTOM OF DUCT MUA MAKE-UP AIR BOP BOTTOM OF PIPE PIPUCTUflE 90 DEGREE DUCTWORK ELBO4 WI TURNING VANES BOR BOTTOM OF N/A NOT APPLICABLE LJ BE BR ITISH THERMAL UNIT N.C. NORMALLY CLOSED NO NOISE CRITERIA TURNING VANES CA COMBUSTION AIR NEC NATIONAL ELECTRICAL CODE CC CONCRETE NEMA NATIONAL ELECTRICAL Ill ASSOC. OR CUBIC FEET PER HOUR NFPA NATIONAL FIRE PROTECTION ASSOC. ROUNDS ELAR - CFM CUBICMILL FEET PER MINUTE NIC NOT IN CONTRACT R RECTANGULAR ROUND OR RECTANGULAR CHNR/COWS CHILLED WATER RETURN/SUPPLY N.O. NORMALLY OPEN COIflC CIRCULATING TUTS NOT TO SCALE O/H OVERHEAD Ca CIRCUIT DUCTWORK BRANCH TAKE -OFF WITH CL CENTERLINE OA OUTSIDE AIR (VENTILATION AIR) 45ULW WITH 45 DEGREE BRANCH INLET OLD CEILING Om OPPOSED BLADE DAMPER CO CLEANOUT OC ON CENTER CONN CONNECT CONNECTION t OD OVERFLOW DRAINAGE, OUTSIDE DIAMETER HIGH EFFIECENY 'BUCKLEY' TAP WITH DAMPER COP PLUG COLUMN OPNG OPENING CIE CONNECT TO EXISTING ORD OVERFLOW ROOF DRAIN CW DOMESTIC COLD WATER OS&Y OUTSIDE STEM AND YOKE DUCTWORK SIZE TRANSITION C'YRIONS CONDENSING WATER RETURNISUPPLY OSHA OCCUPATIONAL SAFETY &HEALTH ADMIN. °C DEGREES CELSIUS SUPPLY OR OUTSIDE AIR DUCT UP PB PUSH BUTTON D DEPTH PC PRESSURE DROP DB MY BULB PH, 0 PHASE all DECIBEL PIV POST INDICATOR VALVE SUPPLY W OUTSIDE AIR DUCT DOWN DOC DIRECT DIGITAL CONTROL PLBG PLUMBING DEG DEGREES PSI POUNDS PER SQUARE INCH RETURN OR EXHAUST AIR DUCT UP DIA (OR 0) DIAMETER PRV PRESSURE RELIEF VALVE DIM DIMENSION � RA RETURN AIR DISC DISCONNECT Lam" J RETURN OR EXHAUST AIR DUCT DOWN ON DONN NCR REFLECTED CEILING PLAN DOM DOMESTIC RD ROOF CRAW DS DOWNSPOUT RECIRC RECIRCULATE IN -LINE 90 DEGREE RISE IN DUCT DING DRAWING BEINF REINFORCING, REINFORCED DX DIRECT EXPANSION HILL RELOCATED ', ", IN -LINE 90 DEGREE DROP IN DUCT RED REV REQUIRED REVISION, REVISE EA EACH EAT ENTERING AIR TEMPERATURE REX REMOVE EXISTING RISE INCLINED RISE IN DUCT EC ELECTRICAL CONTRACTOR RH RELATIVE HUMIDITY EW ENTERING WV BULB RHG REFRIGERANT HOT GAS ELEV ELEVATION FILL REFRIGERANT LIQUID POINT OF CONNECTION - NEW TO EXISTING ELEC ELECTRICAL RLA RUNNING LOAD RIPS ENCL ENCLOSURE RPM REVOLUTIONS PER MINUTE > MANUAL VOLUME DAMPER EMIR EDU IPMENT RR REMOVE AND RELOCATE ESP EXISTING STATIC RE REFRIGERANT SUCTION RWATEREFRIGERANTSUCTION M ESP INESSUflE EXTERNAL TO REMAIN RWC RAIN EWE ENTERING WET BULB MOTORIZED DAMPER SA SUPPLY AIR EAT ENTERING WATER TEMPERATURE SAN SANITARY F EXX EXHAUST SO SMOKE DETECTOR, STORM WAIN FIRE DAMPER EX EXISTING SECT SF SECTION SQUARE FEET, SQUARE FOOT O THERMOSTAT FA FIRE All FACP FIRE ALARM CONTROL PANEL BHT SHEET FCO FLOOR CLEANOUT SM SHEET METAL FD FIRE DAMPER SM40NA SHEET METAL & A/C CWT NAT'L ASSOC. O HUMIDISTAT FF FINISHED FLOOR SIP STATIC PRESSURE FLA FULL LOAD PAIPS SPEC SPECIFICATION ® SENSOR FLEX FLEXIBLE SO SQUARE FP FIRE PROTECTION ST STD STORM WATER STANDARD C CARBON DIOXIDE SENSOR FPM FEET PER MINUTE SURF SURFACE FT FOOT, FEET SUSP SUSPEND FW FILTERED WATER SU DUCT SMOKE DETECTOR TDH TE TOTAL DYNAMIC HEAD TENANT EXHAUST (TOILET) °F DEGREES FAHRENHEIT 0 DRAWING NOTE REFERENCE G GAS GA GAUGE THRU THROUGH ��// GAL GALLON TP TOTAL PRESSURE TSP TOTAL STATIC PRESSURE IIIGalGALVANIZED W ROUND GC GENERAL CONTRACTOR TSTAT THERMOSTAT GFN, GFIC GROUND FAULT INTERRUPTER TYrR/TOMS TOWER WATER RETURNISUPPLV $ OVAL W FLAT OVAL GPD GALLONS PER DAY TYP TYPICAL GPH GALLONS PER HOUR UC UNDERCUT DOOR 3/4' FOR AIRFLOW UIF UNDERFLOOR GPM GALLONS PER MINUTE U/G UNDERGROUND GRD GROUND U/S UNDERSLAB GW GREASE WASTE UL UW UNDERWRITERS LABORATORIES, INC. UNLESS OTHERWISE NOTED H HEIGHT HD HEAD, HUB DRAIN V VOLT, VENT HHWBIHHWS HEATING HOT WATER RETURN/SUPPLY VA VOLT-AMPERE, VALVE HO4 HAND -OFF -AUTOMATIC VAC VACUUM HP HORSEPOWER, HEAT PUMP VAV VARIABLE AIR VOLUME HSTAT HUMIDISTAT VD VOLUME DAMPER HTG HEATING VTR VENT THROUGH ROOF HTR HEATER W WATT, WIDTH WAC HEATING, VENTILATING & A/C BY DOMESTIC HOT WATER W/ WITH WIN DOMESTIC RECIRCULATED HOT WATER W/O WITHOUT HYD HYDRANT Wit WET BULB HZ HERTZ NO WATER COLUMN RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �M;44v�tG,A�,DA�1 DATE: 08/19/19 1' INTERNALLY LINED RETURN AIR DUCTWORK DUCT MOUNTED SMOKE DETECTOR L ROOFTOP UNIT ®\ ROOF TOP UNIT SEAL BETWEEN ALL DUCTS AND RODF DECK WITH SEAL BE IN ALL DUCTS AND ROOF ACDUSTICAL SEALANT DECK WITH ACOUSTICAL SEALANT \� FLE% CONNECTION I � PROVIDE FLEX CONNECTION VERTICAL SUPPLY AIR DUCT BELOW ROOF DECK FOR SUPPLY SHALL BE FULL SIZE OF UNIT AND RETURN AIR DUCT DROPS OPENING. TRANSITION TO DUCT SIZE INDICATED ON PLAN END VIEW 1 RTU SECTION DETAIL All SCALE: NONE SIDE VIEW HAND TIGHT PLUG COPPER CONDENSATE WAIN LINES PAST CURB TO PREVENT CURB FROM RUST DAMAGE. DO NOT USE PVC FOR CONDENSATE DRAIN LINES. KEEP VERTICAL CONDENSATE LINE A MINIMUM OF 3' FROM CURB 'H' = FAN INLET PRESSURE (+) PLUS 1 - J = CONDENSATE TRAP SHOULD BE AT A DEPTH OF [1/2 (11 TO OVERCOME NEGATIVE STATIC PRESSURE OF FAN EXTEND TO RODF WHERE EXISTING IS PIPED TO ROOF WAIN W REO'D BY LOCAL AUTHORITIES. SECTION TO WAIN ONLY MAY BE PVC MIN - 4' MAX MIN. 12'x18'x2' THICK CONWETE SPLASH BLOCK 24'x24- HUMANE ROOF PAD SPUD BACK GRAVEL MASTIC TO ROOF 2 RTU CONDENSATE DETAIL i SCALE: NONE CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317.288.0681 F :: 317. 288. 0753 DRAWN BY: JES CHECKED BY: KW OT/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 8712410 F 440 8717954 tesengineering.mm =-D : �••._ STATE OF i W S CINAII It'00 THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HERBN ARE THE EKCWi INTELLECTUAL PROPERTY OF CURRAN ARCHITECTIIRE AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART. WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE ® CCGYhG TM6, C1AiWNIRCMIEC K WESTON POINTE RETAIL WESTON POINTE DRIVE NORTH MICHIGAN ROAD CARMEL, INDIANA SHELL MECHANICAL LEGEND, DETAILS & ABBREVIATIONS CARMEL RESUBMITTAL 04.07.17 CARMEL COMMENTS O4.27.17 ADDENDUM 1 09.22.17 PERMIT SET 05.21.19 160273 M-0.