HomeMy WebLinkAboutM0.1 Shell MechanicalABBREVIATIONS
HVAC SYMBOLS
A
AMP, AMPERE
TO
INSIDE DIAMETER
ABV
ABOVE
IE
INVERT ELEVATION
A/C
AIR CONDITIONER, AIR CONDITIONING,
IN
INCH, INCHES
ABOVE CEILING
IN WC
INCHES OF WATER COLUMN
SUPPLY AIR DIFFUSER - SHADING INDICATES
ACC
AIR COOLED CHILLER
PATTERN. NO PATTERN SHOWN EQUALS 4-WAY
ACCU
AIR COOLED CONDENSING UNIT
GA
KILOVOLT.PMRS
OR AS NOTED
ADJ
ADJUSTABLE
0
KILOWATTS
AFC
ABOVE FINISHED CEILING
KMH
KILOWATT-HOUR
RETURN OR EXHAUST AIR GRILLE
AFF
ABOVE FINISHED FLOOR
AFG
ABOVE FINISHED GRADE
L
INTERNALLY LINED
AL
ACOUSTIC LINING
LAT
LEAVING AIR TEMPERATURE
ROUND DUCTWORK. DIAMETER IN INCHES
ANSI
AMERICAN iSTANDARDS INSTITUTE
1 #
POUNDS
All
AIR PRESSURE PROP
LW
LEAVING DRY BULB
ARCH
ARCHITECT, ARCHITECTURAL
LP
LOW PRESSURE
20112
RECTANGULAR DUCTWORK. SIZE IN INCHES,
AN
AIR CONDITIONING & REFRIG INSTITUTE
iLOCKED
ROTOR AMPS
FIRST NUMBER IS SIDE GROWN
ASHRAE
AMERICAN SOCIETY OF HEATING,
LTG
LIGHTING
REFRIGERATION & AC ENGINEERS
LWB
LEAVING WET BULB
ASME
AMERICAN SOCIETY OF MECHANICAL ENGRS
UNT
LEAVING WATER TEMPERATURE
%%/%XL_
INTERNALLY LINED DUCT
ABBY
ASSEMBLY
AMERICAN SOCIETY OF TESTING & MATLB
MAX
MAXIMUM
AUX
AUXILIARY
MEN!1CO0
NC
BTU PER HOUR
MECHANICAL CONTRACTOR
®
SUPPLY OR OUTSIDE AIR DUCT
AND
AMERICAN WIRE GAUGE
MCA
MINIMUM CIRCUIT AMPACITY
AWS
AMERICAN WELDING SOCIETY
MCC
MOTOR CONTROL CENTER
RETURN, RELIEF OR EXHAUST AIR DUCT
AWNA
AMERICAN WATER WORKS ASSOC.
NO
MECH
MOTORIZED DAMPER
MECHANICAL
DIFFUSER/GRILLE LABEL:
B/F BELOW FLOOR
BAS
BUILDING AUTOMATION SYSTEM
li
MANUFACTURER
BOD
BAMDRAFT DAMPER
MH
MANHOLE, METAL HALIDE
q B
A - TYPE/DESIGNATION
SIR
BOILER FEED WATER
MIN
MINIMUM
B - NECK SIZE (INCHES)
BLDG
BUILDING
MOCP
MAXIMUM OVER CURRENT PROTECTION
C
C - AIRFLOW (OR)
Bill
BUILDING MANAGEMENT SYSTEM
MTU
MOUNTED
BOD
BOTTOM OF DUCT
MUA
MAKE-UP AIR
BOP
BOTTOM OF PIPE
PIPUCTUflE
90 DEGREE DUCTWORK ELBO4 WI TURNING VANES
BOR
BOTTOM OF
N/A
NOT APPLICABLE
LJ
BE
BR ITISH THERMAL UNIT
N.C.
NORMALLY CLOSED
NO
NOISE CRITERIA
TURNING VANES
CA
COMBUSTION AIR
NEC
NATIONAL ELECTRICAL CODE
CC
CONCRETE
NEMA
NATIONAL ELECTRICAL Ill ASSOC.
OR
CUBIC FEET PER HOUR
NFPA
NATIONAL FIRE PROTECTION ASSOC.
ROUNDS ELAR -
CFM
CUBICMILL FEET PER MINUTE
NIC
NOT IN CONTRACT
R RECTANGULAR
ROUND OR RECTANGULAR
CHNR/COWS
CHILLED WATER RETURN/SUPPLY
N.O.
NORMALLY OPEN
COIflC
CIRCULATING
TUTS
NOT TO SCALE
O/H
OVERHEAD
Ca CIRCUIT
DUCTWORK BRANCH TAKE -OFF
WITH
CL
CENTERLINE
OA
OUTSIDE AIR (VENTILATION AIR)
45ULW
WITH 45 DEGREE BRANCH INLET
OLD
CEILING
Om
OPPOSED BLADE DAMPER
CO
CLEANOUT
OC
ON CENTER
CONN
CONNECT CONNECTION
t
OD
OVERFLOW DRAINAGE, OUTSIDE DIAMETER
HIGH EFFIECENY 'BUCKLEY' TAP WITH DAMPER
COP
PLUG
COLUMN
OPNG
OPENING
CIE
CONNECT TO EXISTING
ORD
OVERFLOW ROOF DRAIN
CW
DOMESTIC COLD WATER
OS&Y
OUTSIDE STEM AND YOKE
DUCTWORK SIZE TRANSITION
C'YRIONS
CONDENSING WATER RETURNISUPPLY
OSHA
OCCUPATIONAL SAFETY &HEALTH ADMIN.
°C
DEGREES CELSIUS
SUPPLY OR OUTSIDE AIR DUCT UP
PB PUSH BUTTON
D
DEPTH
PC
PRESSURE DROP
DB
MY BULB
PH, 0
PHASE
all
DECIBEL
PIV
POST INDICATOR VALVE
SUPPLY W OUTSIDE AIR DUCT DOWN
DOC
DIRECT DIGITAL CONTROL
PLBG
PLUMBING
DEG
DEGREES
PSI
POUNDS PER SQUARE INCH
RETURN OR EXHAUST AIR DUCT UP
DIA (OR 0)
DIAMETER
PRV
PRESSURE RELIEF VALVE
DIM
DIMENSION
�
RA
RETURN AIR
DISC DISCONNECT
Lam" J
RETURN OR EXHAUST AIR DUCT DOWN
ON
DONN
NCR
REFLECTED CEILING PLAN
DOM
DOMESTIC
RD
ROOF CRAW
DS
DOWNSPOUT
RECIRC
RECIRCULATE
IN -LINE 90 DEGREE RISE IN DUCT
DING
DRAWING
BEINF
REINFORCING, REINFORCED
DX
DIRECT EXPANSION
HILL
RELOCATED
', ",
IN -LINE 90 DEGREE DROP IN DUCT
RED
REV
REQUIRED
REVISION, REVISE
EA EACH
EAT
ENTERING AIR TEMPERATURE
REX
REMOVE EXISTING
RISE
INCLINED RISE IN DUCT
EC
ELECTRICAL CONTRACTOR
RH
RELATIVE HUMIDITY
EW
ENTERING WV BULB
RHG
REFRIGERANT HOT GAS
ELEV
ELEVATION
FILL
REFRIGERANT LIQUID
POINT OF CONNECTION - NEW TO EXISTING
ELEC
ELECTRICAL
RLA
RUNNING LOAD RIPS
ENCL
ENCLOSURE
RPM
REVOLUTIONS PER MINUTE
>
MANUAL VOLUME DAMPER
EMIR
EDU IPMENT
RR
REMOVE AND RELOCATE
ESP
EXISTING STATIC
RE
REFRIGERANT SUCTION
RWATEREFRIGERANTSUCTION
M
ESP
INESSUflE
EXTERNAL TO REMAIN
RWC
RAIN
EWE
ENTERING WET BULB
MOTORIZED DAMPER
SA SUPPLY AIR
EAT
ENTERING WATER TEMPERATURE
SAN
SANITARY
F
EXX
EXHAUST
SO
SMOKE DETECTOR, STORM WAIN
FIRE DAMPER
EX
EXISTING
SECT
SF
SECTION
SQUARE FEET, SQUARE FOOT
O
THERMOSTAT
FA FIRE All
FACP
FIRE ALARM CONTROL PANEL
BHT
SHEET
FCO
FLOOR CLEANOUT
SM
SHEET METAL
FD
FIRE DAMPER
SM40NA
SHEET METAL & A/C CWT NAT'L ASSOC.
O
HUMIDISTAT
FF
FINISHED FLOOR
SIP
STATIC PRESSURE
FLA
FULL LOAD PAIPS
SPEC
SPECIFICATION
®
SENSOR
FLEX
FLEXIBLE
SO
SQUARE
FP
FIRE PROTECTION
ST
STD
STORM WATER
STANDARD
C
CARBON DIOXIDE SENSOR
FPM
FEET PER MINUTE
SURF
SURFACE
FT
FOOT, FEET
SUSP
SUSPEND
FW
FILTERED WATER
SU
DUCT SMOKE DETECTOR
TDH
TE
TOTAL DYNAMIC HEAD
TENANT EXHAUST (TOILET)
°F DEGREES FAHRENHEIT
0
DRAWING NOTE REFERENCE
G GAS
GA
GAUGE
THRU
THROUGH
��//
GAL
GALLON
TP
TOTAL PRESSURE
TSP
TOTAL STATIC PRESSURE
IIIGalGALVANIZED
W
ROUND
GC
GENERAL CONTRACTOR
TSTAT
THERMOSTAT
GFN, GFIC
GROUND FAULT INTERRUPTER
TYrR/TOMS
TOWER WATER RETURNISUPPLV
$
OVAL W FLAT OVAL
GPD
GALLONS PER DAY
TYP
TYPICAL
GPH
GALLONS PER HOUR
UC
UNDERCUT DOOR 3/4' FOR AIRFLOW
UIF UNDERFLOOR
GPM
GALLONS PER MINUTE
U/G
UNDERGROUND
GRD
GROUND
U/S
UNDERSLAB
GW
GREASE WASTE
UL
UW
UNDERWRITERS LABORATORIES, INC.
UNLESS OTHERWISE NOTED
H HEIGHT
HD
HEAD, HUB DRAIN
V VOLT, VENT
HHWBIHHWS
HEATING HOT WATER RETURN/SUPPLY
VA
VOLT-AMPERE, VALVE
HO4
HAND -OFF -AUTOMATIC
VAC
VACUUM
HP
HORSEPOWER, HEAT PUMP
VAV
VARIABLE AIR VOLUME
HSTAT
HUMIDISTAT
VD
VOLUME DAMPER
HTG
HEATING
VTR
VENT THROUGH ROOF
HTR
HEATER
W
WATT, WIDTH
WAC HEATING, VENTILATING & A/C
BY
DOMESTIC HOT WATER
W/
WITH
WIN
DOMESTIC RECIRCULATED HOT WATER
W/O
WITHOUT
HYD
HYDRANT
Wit
WET BULB
HZ
HERTZ
NO
WATER COLUMN
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�M;44v�tG,A�,DA�1
DATE: 08/19/19
1' INTERNALLY LINED
RETURN AIR DUCTWORK
DUCT MOUNTED
SMOKE DETECTOR
L
ROOFTOP UNIT ®\ ROOF TOP UNIT
SEAL BETWEEN ALL DUCTS
AND RODF DECK WITH SEAL BE IN ALL DUCTS AND ROOF
ACDUSTICAL SEALANT DECK WITH ACOUSTICAL SEALANT
\� FLE% CONNECTION
I �
PROVIDE FLEX CONNECTION VERTICAL SUPPLY AIR DUCT
BELOW ROOF DECK FOR SUPPLY SHALL BE FULL SIZE OF UNIT
AND RETURN AIR DUCT DROPS OPENING. TRANSITION TO DUCT
SIZE INDICATED ON PLAN
END VIEW
1
RTU
SECTION
DETAIL
All
SCALE:
NONE
SIDE VIEW
HAND TIGHT PLUG
COPPER CONDENSATE WAIN LINES PAST
CURB TO PREVENT CURB FROM RUST DAMAGE.
DO NOT USE PVC FOR CONDENSATE DRAIN
LINES. KEEP VERTICAL CONDENSATE LINE A
MINIMUM OF 3' FROM CURB
'H' = FAN INLET PRESSURE (+) PLUS 1 -
J = CONDENSATE TRAP SHOULD BE
AT A DEPTH OF [1/2 (11 TO
OVERCOME NEGATIVE STATIC
PRESSURE OF FAN
EXTEND TO RODF WHERE
EXISTING IS PIPED TO ROOF
WAIN W REO'D BY LOCAL
AUTHORITIES. SECTION TO
WAIN ONLY MAY BE PVC
MIN - 4' MAX
MIN. 12'x18'x2' THICK
CONWETE SPLASH BLOCK
24'x24- HUMANE ROOF
PAD SPUD BACK GRAVEL
MASTIC TO ROOF
2
RTU CONDENSATE DETAIL
i
SCALE: NONE
CURRAN
ARCHITECTURE
5719 LAWTON LOOP E. DR. #212
INDIANAPOLIS, IN 46216
O :: 317.288.0681
F :: 317. 288. 0753
DRAWN BY: JES CHECKED BY: KW
OT/E/S
ENGINEERING
25760 First Street
Cleveland, OH 44145
P 440 8712410
F 440 8717954
tesengineering.mm
=-D :
�••._ STATE OF i W
S CINAII It'00
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HERBN ARE
THE EKCWi INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTIIRE AND ARE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART. WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHITECTURE
® CCGYhG TM6, C1AiWNIRCMIEC K
WESTON POINTE RETAIL
WESTON POINTE DRIVE
NORTH MICHIGAN ROAD
CARMEL, INDIANA
SHELL MECHANICAL
LEGEND, DETAILS &
ABBREVIATIONS
CARMEL RESUBMITTAL 04.07.17
CARMEL COMMENTS O4.27.17
ADDENDUM 1 09.22.17
PERMIT SET 05.21.19
160273
M-0.