HomeMy WebLinkAboutM0.3 Shell Mechanical PlanROOFTOP HVAC UNIT SCHEDULE SUPPLY FAN DATA GX COOLING DATA GAS HEATING DATA UNIT CHARACTERISTICS TAG SERVICE MFfl MODEL Na. NOMINAL EEfl/SEER MIN OA NOTES/OPERATING TONS ICFM) AIR FLOW ESP MOTOR FAN FAT RAT SENSIBLE TOTAL COOLING INPUT OUTPUT HEATING VOLTAGE ACCESSORIES ICFM) (IN WC) (HP) (RPM) °pB/°COB °GB/°COB (MBH) (MBH) STAGES EAT/MAT F (MEN) (MBH) STAGES IV-�-HZ) UNIT MCA UNIT MOCP WEIGHT (LBS) RTU-1 TENANT 101 RTU-4 TENANT 103 TRANE YHW74 6.0 13.1/16.0 600 2400 0.8 3.8 1077 79.0/66.8 56.4/55.9 58.7 73.6 1 51.8/89.1 120.0 97.2 1 208-3-60 37.4 50.0 1132 1-18 RTU-5 TENANT 105 RTII TENANT 106 RTU-2 TENANT 102 TENANT 102 TENANT 107 TRANE YHM92 7.5 12.6/14.5 750 3000 0.8 1.0 1142 79.0/66.8 58.5156.9 66.3 91.6 2 51.8189.1 150.0 120.0 2 208-3-W 42.0 50.0 1291 1-18 FRTRTU-3 U-] 1. 95° CONDENSING TEMPERATURE 2. REFRIGERANT - R410A 3. 100% ECONOMIZER WITH FIXED DWYBULB CONTROL 4. BAROMETRIC RELIEF 5. 14' INSULATED ROOF CURB 6. HACR CIRCUIT BREAKER ]. UN -POWERED CONVENIENCE OUTLET 8. DIRECT DRIVE 9. SINGLE ZONE VAV 10. THROUGH THE BASE ELECTRICAL 11. HAIL GUARD - WITH TOOL LESS REMOVAL 12. PROGRAMMABLE SEVEN DAY AUTO CHANGE OVER THERMOSTAT WITH REMOTE TEMPERATURE SENSOR 13. HINGED ACCESS DOORS 14. 2- PLEATED FILTERS MERV 8 15. MICRO -PROCESSOR CONTROLS 16. 5 YEAR COMPRESSOR WARRANTY 17. STAINLESS STEEL HEAT EXCHANGER 18. 10 YEAR WARRANTY ON HEAT EXCHANGER aT - &7 - 8.8 - "� RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �NI��V'�0*1411PML DATE: \ 08/19/19 GENERAL SHEET NOTES 1. ANYTHING NOT NOTED AS EXISTING IS TO BE FURNISHED AND INSTALLED AS PART OF THIS PROJECT. 2. REFER TO DRAWINGS AND PROU EDT SPECIFICATIONS OF OTHER DISCIPLINES FOR ADDITIONAL PROJECT INFORMATION AND REQUIREMENTS. NOTIFY ENGINEER OF MY CONFLICTS BETWEEN THE INFORMATION PRESENTED AND FIELD CONDITIONS. 3. MECHANICAL SYSTEMS INSTALLATION MUST MAINTAIN INTEGRITY OF WALLS, PARTITIONS AND FLOORS DESIGNATED AS EITHER FIRE RATED OR 'SMOKE TIGHT'. SEAL AROUND ALL PENETRATIONS THROUGH RATED OR MORE TIGHT ASSEMBLIES. COORDINATE W/ARCHITECTURAL PLANS AND GENERAL CONTRACTOR. 4. ALL ROOF PENETRATIONS, PATCHING AND FLASHING SHALL BE PERFORMED BY AN APPROVED ROOFING CONTRACTOR AT THIS CONTRACTOR'S EXPENSE. COORDINATE ROOF PENETRATIONS AND ROOFTOP EQUIPMENT LOCATIONS WITH LANDLORD AND GENERAL CONTRACTOR. S. NOTHING IS PERMITTED TO BE ATTACHED T05 SUSPENDED FROM, OR PENETRATE THE ROOF DECK. CONTRACTOR MAY ATTACH TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL WHICH EXISTS ABOVE THE SPACE. 6. COORDINATE FINAL ROOFTOP UNIT LOCATIONS WITH STRUCTURAL ENGINEER. PROVIDE 10' CLEARANCE FROM UNIT OUTSIDE AIR INTAKE TO ANY EXHAUST/VENTS ON ROOF. 7. GENERAL CONTRACTOR TO LABEL ALL ROOFTOP EQUIPMENT WITH TENANT NAME, SPACE NUMBER AND EOU IPMENT IDENTIFICATION (RTU-1, ETC.), PER MALL SPECIFICATIONS AND STANDARDS. 8. PITCH POCKETS ARE NOT PERMITTED ON THE ROOF FOR CONDENSATE DRAINS, POWER OR CONTROL WIRING. ALL CONNECTIONS ARE TO BE MAIZE INSIDE THE EQUIPMENT CURB OR THROUGH PRE -MANUFACTURED PIPING CURB. Q SHEET KEYNOTES 1 PROVIDE SUPPLY AND RETURN DUCT DROPS FULL SIZE WITH FLEX CONNECTION AT UNIT DOWN THRU ROOF TO 1'-0' BELOW JOIST FOR FUTURE TENANT CONNECTION. 2 PROVIDE 7-DAY PROGRAMMABLE THERMWTAT. THERMOSTAT SHALL BE SUSPENDED IN JOIST SPACE WITH 50' OF COILED WIRE FOR FUTURE TENANT RELOCATION. 3 RETURN AIR MOUNTED SMOKE DETECTOR PROVIDED AND WIRED BY ELECTRICAL CONTRACTOR, MOUNTED BY MECHANICAL CONTRACTOR. I I I I I I III I II I I I I 1 III 1 II II II II I I I II I (TYPICAL) (50Jr-H��P _ ,�J--F��� (,�' _I -I (TYPICAL) 0 I 02 1 1 11 1 � '��I I I (TYPp[CAL) I I I I I I 1 1 I I I I I I L_J L_J L_J L_J L_J L-J L_J RTU-1 RTU-2 RTU-3 RTU-4 RTU-5 RTU 6 RTU-7 II 1tl1 TENANT 102 TENANT 103 TENANT 105 TENANT 106 TENANT 107 TENANT 1,8]0 SF L 31020 SF 1,876 SF � 11840 SF 21126 SF 25347 SFI L - - - - - - - II II I I I I II I II II II II I 1 1 I �11 I II II 1 SHELL MECHANICAL PLAN M-0d SCALE: 118'=1'-0' CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317. 288.068I IF :: 317. 288. 0753 DRAWN BY: JES CHECKED BY: GOP OT/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 8712410 F 440 8717954 tesengineering.com ttIIIINIM/r, T�.. STATE OF r W� S//O I I IAI1 TI1f \\`\\\ THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND PRE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHTECTURE 0 COPYHVV4T2016CIMR4N0.RCHIlECNP£ WESTON POINTE RETAIL WESTON POINTE DRIVE NORTH MICHIGAN ROAD CARMEL, INDIANA SHELL MECHANICAL PLAN CARMEL RESUBMITTAL 04.07.17 CARMEL COMMENTS O4.27.17 ADDENDUM 1 09.22.17 Q PERMIT SET 05.21.19 160273 M=0.3