HomeMy WebLinkAboutP0.1 Plumbing ShellPLUMBING ABBREVIATIONS
(ALL
(ALL ABBREVIATIONSSHOWN PAS NOT
PLUMBING
SYMBOLS
NECESSARILY O
USED ON DRAWINGS)
(ALL SYMBOLS SHOWN
ARE NOT NECESSARILY USED ON DRAWINGS)
A
AMP, AMPERE
a
KILOWATTS
Me ABOVE
OWN KILOWATT-HOUR
AN
ABOVE CEILING
ELBOW UP
AW
ADJUSMOVE ABLEFINISHED
L9S, k
POUNDS
AFC
PROVE FINISHED CEILING
LP
LOW NE
3
ELBOW GOWN
ME
MOVE FINISHED FLOOR
LOUT
LEAVING WATER TEMPERATURE
AEG
ABOVE FINISHED GflPDE
VALVE IN MOP
ANS
ABOVE UND�6
MAX
MAXIMUM
ANSI
AN MAIL INSTITUTE
AMERICAN NAARC
MBH
1000 BTU PER HOUR
ARCH
ARCHITECT ARCHITECTURAL
MC
MECHANICAL CONTRACTOR
DIRECTION OF FLOW
ASME
CIEU OF MECHANICAL
ASSEMBLY �(ICIETV OF MECHANICAL ENGHS
MCA
MINIMUM CIRCUIT PMPACITV
pI
TEE OUTLET UP
ASSV
ASSEMBLY
INCH
MECHANICAL
ASTM
AMERICAN SOCIETY OF TESTING & MAi
MEN
MANUFACTURER
AUX
AUXILIARY
MH
MANHOLE, METAL HALIDE
TEE OUTLET DOWN
AWN
AMERICAN WELDING SOCIETY
MIN
MINIMUM
AWNA
AMERICAN WATER WORKS ASSOC.ASS
MOCP
MID
MAXIMUM OVER WflflENT PROTECTION
MOUNTED
IN
UNION
B/F BELOW FLOOR
BLDG
BUILDING
BALL VALVE
BOP
BOTTOM OF PIPE
NIA
NOT APPLICABLE
BOBBOTTOM
OF STRUCTURE
N.C.
NORMALLY CLOSED
D4
GATE VALVE
BTTUU
BRITISH THERMAL UNIT
NEC
NATIONAL ELECTRICAL CODE
NEMA
NFPA
NATIONAL ELECTRICAL NEWS ASSOC.
NATIONAL FIRE PROTECTION ASSOC.
OBEY VALVE
CA COMBUSTION AIR
CFH
CUBIC FEET PER HOUR
NIC
NOT IN CONTRACT
CALIBRATED BALANCING VALVE
CIRC
CIRCULATING
N.O.
NORMALLY OPEN
CL
CENTERLINE
MS
NOT TO SCALE
OLD
CEILING
CHECK VALVE
CO
CLEANOUT
OIH
OVERHEAD
CONN
CONNECT CONNECTION
OC
ON CENTER
PRESSURE REDUCING VALVE
COP
CLEANI PLUG
OD
OVERFLOW DRAINAGE, OUTSIDE DIAMETER
COL
COLUMN
OPINE
OPENING
BUTTERFLY VALVE
GTE
CONNECT TO EXISTING
ORD
OVERFLOW ROOF DRAIN
CW
°C
DOMESTIC COLD WATER
OS&Y
OUTSIDE STEM AND YOKE
7}
HOSE 8IB8
DEGREES CELSIUS
OSHA
OCCUPATIONAL SAFETY &HEALTH ADMIN.
—SAN —
SANITARY PIPING
D
DEPTH
PD
PRESSURE MOP
DEG
DEGREES
PH, B
PHASE
y
SANITARY VENT PIPING
DIA (W 0)
DIAMETER
PIV
POST INDICATOR VALVE
NO —
STORM PIPING A/G
DIM
DIMENSION
PLBG
PLUMBING
DISC
DISCONNECT
PSI
POUNDS PER SQUARE INCH
— ST
STORM PIPING U/G
ON
DOM
DOWN
DOMESTIC
PRV
PRESSURE RELIEF VALVE
— W —
OVERFLOW DRAIN PIPING
RD
ROOF DRAIN
IS DONNSPOUT
— —
COLD WATER (CW) PIPING
DWG
DRAWING
RECIRC
RECIRCULATE
REINF
REINFORCING, REINFORCED
— — — —
HOT WATER (HOC) PIPING
EA
EC
EACH
ELECTRICAL CONTRACTOR
REL
RED
RELOCATED
REQUIRED
HOT WATER RECIRCULATION HE
ELEV
ELEVATION
REV
REVISION, REVISE
G
NATURAL GAS PIPING
ELEC
ELECTRICAL
REX
REMOVE EXISTING
ENCL
ENCLOSURE
RPM
REVOLUTIONS PER MINUTE
]
CAP ON END LINE
EQUIP
EQUIPMENT
RR
REMOVE AND RELOCATE
SIR
ENT
EXISTING TO REMAIN
ENTERING WATER TEMPERATURE
RWC
RAIN WATER CONDUCTOR
zz
IA21
GAS VALVE
SAN
SD
SANITARY
STORM DRAIN
SX EXISTING
"kF
'T7
T&P RELIEF VALVE
FCO FLOOR CLEANOUT
SECT
SECTION
FD
FLOOR DRAIN
SF
SQUARE FEET, SQUARE FOOT
— — — — — — — — 1I
WALL CLEANOUT OR CLEANOUT PLUG
FF
FINISHED FLOOR
SP
STATIC PRESSURE
FLA
FULL LOAD AMPS
SPEC
SPECIFICATION
FLOOR CLEANOUT
FLEX
FLEXIBLE
SO
SQUARE
�^,
HP
FIRE PROTECTION
ST
STORM WATER
FT
FOOT, FEET
STD
STANDARD
PRESSURE GAUGE WITH GOUGE COCK
FW
FILTERED WATER
SURF
SURFACES
°F
DEGREES FAHRENHEIT
SUSP
SUSPEND
THERMOMETER
WATER METER
G GAS
TOP TOTAL DYNAMIC HEAD
GA
GAUGE
TSTAT
THERMOSTAT
GAL
GALLON
UP
TYPICAL
�
GAS REGULATOR
G
GALVANIZED
/F
UNDERGROUN
O
GC GENERAL CONTRACTOR
GPD
GALLONS PER DAY
VIG
UNDERGROUND
�
FLEXIBLE CONNECTION
GPH
GALLONS PER HOUR
U/S
UNDERSLAB
GPM
GALLONS PER MINUTE
UL
UNDERWRITERS LABORATORIES, INC.
PIPE FLANGE
GW
GREASE WASTE
UON
UNLESS OTHERWISE NOTED
THERMOMETER WELL
H
HEIGHT
V
VOLT, VENT
HD
HERD HUB DRAIN
VA
VALVE
�O
FLOOR SINK (FS)
HP
HIS
HORSEPOWER, HEAT PUMP
HEATING
VAC
VACUUM
JO
FLOOR DRAIN WITH P-TRAP
HTR
HEATER
VTR
VENT THROUGH ROOF
HVAC
HEATING, VENTILATING & A/C
W
WATT, WIDTH
El E0
PLUMBING FIXTURES
HW
DOMESTIC HOT WATER
W/
WITH
HE
DOMESTIC RECIRCULATED HOT WATER
W/o
WITHOUT
®
GAS MANIFOLD LOCATION
HYD
HYDRANT
WC
WATER COLUMN
HZ
HERTZ
DOUBLE CHECK BACKFLOW PREVENTER
LOV
ID
INSIDE DIAMETER
��
DOMESTIC WATER RISER
IE
INVERT ELEVATION
IN
INCH, INCHES
POINT OF NEW CONNECTION
IN WC
INCHES OF WATER COLUMN
TO EXISTING PIPING OR SYSTEM
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City of Camel
�VT�'�G*T41WMt_
DATE: \ 08/19/19
COPPER TOP. FINISH AS -
SELECTED BY ARCH.
BRASS PLUS
AS REQUIRED FITTING —
OR EXTENSION
SANITARY OR STORM
FLUSH WITH
FINISHED FLOOR
FINISHED FLOOR
OR WALK
CAULK
I
FLOOR CLEANOUT DETAIL
P-0.1
SCALE: NONE
PLUMBING FIXTURE AND EQUIPMENT SCHEDULE
CONNECTION SIZE
TAG
FIXTURE TYPE
MEN
MODEL No.
DESCRIPTION
SAN
VENT
NN
ON
SEE
ADJUSTABLE CLEANOUT, IF FLOURS ARE TILED OR TERRAZZO PROVIDE WITH
FCO
FLOUR CLEAN OUT
PUNS
-
-
-
J.R. SMITH
4000 SERIES
NICKEL BRONZE FINISH, IF FLOORS ARE CARPETED PROVIDE WITH RECESSED
TOP. CLEANDUTS ARE TO BE FLUSH WITH FINISHED FLOOR.
REDUCED PRESSURE
LEAD FREE RPZ, BRONZE. MAXIMUM PRESSURE 175 LBS. MOUNT IN ACCESSIBLE
RPBFP
BACNFLOW PREVENTER
1-112'
WATTS
LF919
LOCATION, ON UNISTRUT AND STANCIOUSISHELF.
UNISTRUT SECURED TO EXTERIOR
OF THE WALL (TYP. OF 2)—
ur uns LLNL PHLswxL. 2-112,
VIDE GAS PRESSURE
ULATOR IF REQUIRED
COOK
SERVICE ON ROOF. 3' NO
ER TO PLANS FOR
TINUATION AND SIZES GAS PRESSURE
REGULATOR 2k
BY LOCAL UTILITY
EG COMPANY
2
GAS
CONNECTION DETAIL - ROOFTOP UNITS
P-0.1
SCALE:
NONE
B-LINE C-PORT
8' X 18' X 112
TALK PAD AT
ACH SUPPORT ,
GAS PIPING BY PLUMBING CONTRACTOR. ALL GAS PIPING IS TO
BE RACKED UP TIGHT TO THE EXTERIOR WALL, ROUTED AROUND
BUTTER SYSTEM AND ONTO THE ROOF (UP.)
180 CF
UNION
GAS COCK (UP)
TRANSITION RISEN
DETAIL NOTES
GAS METERS PROVIDED TO
TENANT BY THE LOCAL UTILITY COMPANY
(GAS PRESSURE AT METER 2 PSI)
1. GAS MANIFOLD SHOWN IS FOR CONCEPTUAL REFERENCE ONLY. REFER TO THE GAS SCHEDULES
ON THE BUILDING DRAWINGS FOR QUANTITIES AND CONNECTED LOADS OF TENANT SPACES.
2. TENANT CONTRACTORS ARE TO ROUTE ALL MANIFOLD GAS PIPING UP THE SIDE OF THE
EXTERIOR BUILDING TIGHT TO THE WALL AS POSSIBLE. COORDINATE ALL MOUNTING AND
PIPE STRAP ROUTING LOCATIONS WITH LANDLORDS REPRESENTATIVE PRIOR TO ANY WORK.
3. SUPPORT ALL MANIFOLD PIPING PER UTILITY COMPANY RECOMMENDATION.
5
BUILDING GAS MANIFOLD DETAIL
PO.1
SCALE: NONE
NOTES
1. INSTALLATION SHALL BE PER MANUFACTURERS RECOMMENDATIONS.
2. WOW BLOCK SUPPORTS ME NOT ACCEPTABLE
3. BLACK IRON PIPING SHALL BE PAINTED; (PAINTING OF GALVANIZED PIPING IS NOT REO'D)
3
GAS SUPPORT ON ROOF DETAIL
P-0.1
SCALE: NONE
1-1/2• DOMESTIC
SUPPLY
1-1/2• WATTS SERIES LF919 REDUCED
PRESSURE BACKFLOW PREVENTER WITH
STRAINER. PROVIDE AIR GAP AND
PIPE TO FLOOR SINK.
NON RISING STEM (TYP)
STRAINER
1-1/2' EMU METER
WALL SUPPORTS
FLOOR SINK
FINISHED FLOOR
4
INCOMING SERVICE
P.01
SCALE: NONE
MANIFOLD PIPING TO BE SECURELY
FASTENED TO WALL IN A MINIMUM
OF 8 PLACES.
TO TENANT PIPING
BY PLUMBING
CONTRACTOR
CURRAN
ARCHITECTURE
5719 LAWTON LOOP E. DR. #212
INDIANAPOLIS, IN 46216
O :: 317.288.0681
IF :: 317. 288. 0753
DRAWN BY: SIR CHECKED BY: KDH
OT/E/S
ENGINEERING
25760 First Street
Cleveland, OH 44145
P 440 8712410
F 440 8717954
tesengineering.com
��.• STATE OF W�
//O I I IAA 11111?\\\\\
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND PRE NOT
TO BE USED OR REPRODUCED, WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHTECTURE
0 CONY T2016CL%WN0.4CHRECILW£
WESTON POINTE RETAIL
WESTON POINTE DRIVE
NORTH MICHIGAN ROAD
CARMEL, INDIANA
SHELL PLUMBING
DETAILS & SCHEDULES
CARMEL RESUBMITTAL 04.07.17
CARMEL COMMENTS O4.27.17
ADDENDUM 1 09.22.17
Q PERMIT SET 05.21.19
160273
P=0.I