GENERAL SHEET NOTES
1. EXISTING PLUMBING INFORMATION IS BASED ON LIMITED EXISTING BUILDING DRAWINGS AND
FIELD WORK. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY.
CONTRACTOR SHALL NOTIFY OWNER, ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY
OR INCREASE THE SCOPE OF WORK FROM THAT IS DESCRIBED IN THE DOCUMENTS.
2. REFER TO DRAWINGS AND PROJECT SPECIFICATIONS OF OTHER DISCIPLINES FOR ADDITIONAL
PROJECT INFORMATION AND REQUIREMENTS. NOTIFY ENGINEER OF MY CONFLICTS BETWEEN THE
INFORMATION PRESENTED AND FIELD CONDITIONS.
3. PLUMBING INSTALLATION MUST MAINTAIN INTEGRITY OF WALLS, PARTITIONS AND FLOORS
DESIGNATED AS EITHER FIRE RATED OR 'SMOKE TIGHT'. SEAL MOUND ALL PENETRATIONS
THROUGH RATED OR SMOKE TIGHT ASSEMBLIES. COORDINATE WITH ARCHITECTURAL PLANS AND
GENERAL CONTRACTOR.
4. NOTHING IS PERMITTED TO BE ATTACHED T05 SUSPENDED FROM, OR PENETRATE THE ROOF DECK.
CONTRACTOR MAY ATTACH TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST OR THE
STRUCTURAL STEEL WHICH EXISTS PROVE THE SPACE.
5. ALL CONCEALED PIPING SHALL BE TESTED AND PROVEN WEATHERPROOF PRIOR TO CONCEALMENT.
6. SEE SITE PLANS FOR METER SIZES.
O SHEET KEYNOTES
1 2-1/2' WATER SERVICE. SEE SITE PLANS FOR ADDITIONAL INFO ON INCOMING WATER SERVICE.
2 6- SANITARY. SEE SITE PLANS FOR ADDITIONAL INFORMATION.
3 1- ON VALVED TAP FOR FUTURE TENANT CONNECTION. PROVIDE METER WITH REMOTE READER TO
EACH SUITE.
4 GAS METER MANIFOLD ASSEMBLY: SEE SITE PLAN FOR ADDITIONAL INFORMATION. COORDINATE
METER INSTALLATION WITH UTILITY. SEE DETAIL FOR ADDITIONAL INFORMATION.
5 6' GREASE WASTE TO MO GALLON GREASE TRAP. SEE SITE PLANS FOR ADDITIONAL
INFORMATION.
6 EMBLY
7 PROVIDE 12' SLEEVE FOR FUTURE FIRE LINE
8 PROVIDE 8- SLEEVE TO GREASE INTERCEPTOR
9 SA' OW VALVED TAP FPR FUTURE TENANT CONNECTION. PROVIDE METER WITH REMOTE READS
TO ITE.
3
1
PLUMBING
PLAN
P-0.2
SCALE: 11S-=1W
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City d Camel
DATE: 08/19/19
CURRAN
ARCHITECTURE
5719 LAWTON LOOP E. DR. #212
INDIANAPOLIS, IN 46216
O :: 317. 288.068I
IF :: 317. 288. 0753
DRAWN BY: SIR CHECKED BY: ROI
OT/E/S
ENGINEERING
25760 First Street
Cleveland, OH 44145
P 440 8712410
F 440 8717954
tesengineering.com
T�.. STATE OF r W�
S//O I I IAI11111?\`\\\
THIS DRAWING AND THE IDEAS, DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE FXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND PRE NOT
TO BE USED OR REPRODUCED, WHOLE DR
IN PART, WITHOUT THE WRITTEN
CONSENT OF CURRAN ARCHTECTURE
0 C VUa4T2016CLIUAN0.RCHIlECNP£
WESTON POINTE RETAIL
WESTON POINTE DRIVE
NORTH MICHIGAN ROAD
CARMEL, INDIANA
OVERALL PLUMBING
PLAN
CARMEL RESUBMITTAL 04.07.17
CARMEL COMMENTS O4.27.17
ADDENDUM 1 09.22.17
Q PERMIT SET 05.21.19
160273
P=0.2