Loading...
HomeMy WebLinkAboutP0.2 Overall Plumbing PlanC.7 — V (II — &S — - GENERAL SHEET NOTES 1. EXISTING PLUMBING INFORMATION IS BASED ON LIMITED EXISTING BUILDING DRAWINGS AND FIELD WORK. THE CONTRACTOR SHALL FIELD VERIFY THE EXISTING CONDITIONS FOR ACCURACY. CONTRACTOR SHALL NOTIFY OWNER, ARCHITECT AND ENGINEER OF ANY SITUATIONS THAT MODIFY OR INCREASE THE SCOPE OF WORK FROM THAT IS DESCRIBED IN THE DOCUMENTS. 2. REFER TO DRAWINGS AND PROJECT SPECIFICATIONS OF OTHER DISCIPLINES FOR ADDITIONAL PROJECT INFORMATION AND REQUIREMENTS. NOTIFY ENGINEER OF MY CONFLICTS BETWEEN THE INFORMATION PRESENTED AND FIELD CONDITIONS. 3. PLUMBING INSTALLATION MUST MAINTAIN INTEGRITY OF WALLS, PARTITIONS AND FLOORS DESIGNATED AS EITHER FIRE RATED OR 'SMOKE TIGHT'. SEAL MOUND ALL PENETRATIONS THROUGH RATED OR SMOKE TIGHT ASSEMBLIES. COORDINATE WITH ARCHITECTURAL PLANS AND GENERAL CONTRACTOR. 4. NOTHING IS PERMITTED TO BE ATTACHED T05 SUSPENDED FROM, OR PENETRATE THE ROOF DECK. CONTRACTOR MAY ATTACH TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL WHICH EXISTS PROVE THE SPACE. 5. ALL CONCEALED PIPING SHALL BE TESTED AND PROVEN WEATHERPROOF PRIOR TO CONCEALMENT. 6. SEE SITE PLANS FOR METER SIZES. O SHEET KEYNOTES 1 2-1/2' WATER SERVICE. SEE SITE PLANS FOR ADDITIONAL INFO ON INCOMING WATER SERVICE. 2 6- SANITARY. SEE SITE PLANS FOR ADDITIONAL INFORMATION. 3 1- ON VALVED TAP FOR FUTURE TENANT CONNECTION. PROVIDE METER WITH REMOTE READER TO EACH SUITE. 4 GAS METER MANIFOLD ASSEMBLY: SEE SITE PLAN FOR ADDITIONAL INFORMATION. COORDINATE METER INSTALLATION WITH UTILITY. SEE DETAIL FOR ADDITIONAL INFORMATION. 5 6' GREASE WASTE TO MO GALLON GREASE TRAP. SEE SITE PLANS FOR ADDITIONAL INFORMATION. 6 EMBLY 7 PROVIDE 12' SLEEVE FOR FUTURE FIRE LINE 8 PROVIDE 8- SLEEVE TO GREASE INTERCEPTOR 9 SA' OW VALVED TAP FPR FUTURE TENANT CONNECTION. PROVIDE METER WITH REMOTE READS TO ITE. 3 1 PLUMBING PLAN P-0.2 SCALE: 11S-=1W RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City d Camel DATE: 08/19/19 CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317. 288.068I IF :: 317. 288. 0753 DRAWN BY: SIR CHECKED BY: ROI OT/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 8712410 F 440 8717954 tesengineering.com T�.. STATE OF r W� S//O I I IAI11111?\`\\\ THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE FXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND PRE NOT TO BE USED OR REPRODUCED, WHOLE DR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHTECTURE 0 C VUa4T2016CLIUAN0.RCHIlECNP£ WESTON POINTE RETAIL WESTON POINTE DRIVE NORTH MICHIGAN ROAD CARMEL, INDIANA OVERALL PLUMBING PLAN CARMEL RESUBMITTAL 04.07.17 CARMEL COMMENTS O4.27.17 ADDENDUM 1 09.22.17 Q PERMIT SET 05.21.19 160273 P=0.2