Loading...
HomeMy WebLinkAboutP0.3 Overall Plumbing Roof Plan1 I I I 1 RI ER II IL ROOM / II III II II 1 / II II I I I II I I I II II II -4 t — — — — — — — — — — 3 nl�4ON 3 31-1/4' ON F 1-1/4' ON ROOF 1 ON ROOF r ON ROOF(120 CFH (150 CFH (20 CFH) 120 OF I I I II I I II RT&1 RTU-2 RTU-3 RN -4 D II I ILOI � II L_J 1O2 TENANT TENANT 2,070 sf 39202 sf 103 1 I TENANT 11 0 / 2,000 sf II II — — — — — — — — — — I/ I II I I I II B.8 — 10 TENANT 2, 11 SF RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �VT�MTM�O*VAWML DATE: \\ 08/19/19 I I I I I I I I I L- 102 TENANT 103 TENANT 35088 SF 15330 SF I II II II I II II 104 WANT O 1,33 SF GAS EQUIPMENT SCHEDULE TAG DESCRIPTION LOAD (CFH) RTU-1 ROOF TOP UNIT 120 RTU-2 ROOF TOP UNIT 150 RTU-3 ROOF TOP UNIT 150 RTU-4 ROOF TOP UNIT 120 RTU-5 ROOF TOP UNIT 120 RTU-6 ROOF TOP UNIT 120 RTU-] ROOF TOP UNIT 180 TOTAL 900 1-1/4' ON ROOF - (125 CFH)- 1-114' ON ROOF (144 CFH) 314- ON ROOF �72LEk) — F — — I I L _ J 105 ,TENANT 1,966 sf ,,--314' ON ROOF (72 CFH) �1- ON ROOF (125 CFH) �1- ON ROOF (125CFH) - 1- ON ROOF 1120 CFH) Ul I 4- 1- 106 L__JI TENANT 2,070 sf 105 TENANT 106 TENANT 15330 SF 25312 SF 1 1 OVERALL ROOF PLUMBING PLAN 10 P-0.3 I SCALE 118'=1'-0' 1- ON (1 ED 1 GENERAL SHEET NOTES 1. ALL CONCEALED PIPING SHALL BE TESTED AND PROVEN WEATHERPROOF PRIOR TO CONCEALMENT. 2. REFER TO DRAWINGS AND PROJECT SPECIFICATIONS OF OTHER DISCIPLINES FOR ADDITIONAL PROJECT INFORMATION AND REOOIREMENTS. NOTIFY ENGINEER OF ANY CONFLICTS BETWEEN THE INFORMATION PRESENTED AND FIELD CONDITIONS. 3. PLUMBING INSTALLATION MUST MAINTAIN INTEGRITY OF WALLS, PARTITIONS AND FLOORS DESIGNATED AS EITHER FIRE RATED OR 'SMOKE TIGHT'. SEAL AROUND ALL PENETRATIONS THROUGH RATED OR SMOKE TIGHT ASSEMBLIES. COORDINATE WITH ARCHITECTURAL PLANS AND GENERAL CONTRACTOR. 4. ALL EXPOSED, EXTERIOR PIPING SHALL BE PAINTED WITH RUST INHIBITIVE PRIMER, COLOR CODED FINISH, AND IDENTIFICATION LABELS. S. VERIFY NATURAL GAS AVAILABILITY AND CAPACITY. COORDINATE PRESSURE, SERVICE CONNECTION, AND METER INSTALLATION WITH THE LANDLORD AND LOCAL UTILITY COMPANY. 6. PROVIDE GAS PIPE SUPPORTS ON ROOF. PROVIDE 10'-0' ON CENTER AND AT ALL CHANGES OF DIRECTION. REFER TO DETAIL 5 ON SHEET P-01, 7. NOTHING IS PERMITTED TO BE ATTACHED T05 SUSPENDED FROM, OR PENETRATE THE ROOF DECK. CONTRACTOR MAY ATTACH TO OR SUSPEND FROM THE TOP CHORD OF THE JOIST OR THE STRUCTURAL STEEL WHICH EXISTS ABOVE THE SPACE. O GAS PIPING DRAWING NOTES 1 EXTEND AND OONNECT NEW GAS PIPING TO GAS MANIFOLD, SEE DETAILS FOR MORE INFORMATION. VERIFY SIZE AND LOCATION PRIOR TO CONSTRUCTION. 2 SEE MOE'S PLANS FOR ADDITIONAL INFORMATION ON SPACE 104. I ROOF_ _ _ _ _ _ — I —UT vr'] I L__J 107 TENANT 2,550 sf I 0 107 TENANT 2,347 SF pip CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O :: 317. 288. 0681 F :: 3I7. 288. 0753 DRAWN BY: STK CHECKED BY: RON *T/E/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 8712410 F 440 8717954 tesengineering.com All I I I II//2, _) F�.. STATE OF ///I N Al 11tAAA o THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCE, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE 0 COPMOiT201QCIMMNA"ITECNF£ WESTON POINTE RETAIL WESTON POINTE DRIVE NORTH MICHIGAN ROAD CARMEL, INDIANA SHELL OVERALL PLUMBING ROOF PLAN CARMEL RESUBMITTAL 04.07.17 CARMEL COMMENTS O4.27.17 ADDENDUM 1 09.22.17 ,&PERMIT SET 05.21.19 160273 P=0.3