Loading...
HomeMy WebLinkAboutA5.5 Wall SectionsRELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City of Camel �N;A��3tB,�DA�1 DATE: 08/19/19 NOTE: LADDER INFORMATION SHOWN FOR GENERAL DESIGN INTENT ONLY. CONTRACTOR SHALL PROVIDE/INSTALL LADDER ASSEMBLY WHICH 15 IN FULL COMPLIANCE WITH ALL LOCAL, • _ STATE AND FEDERAL CODES AND OSHA REGULATIONS. SUBMIT SHOP DRAWINGS FOR REVIEW. WALL SECTION 3 WALL SECTION A 2 WALL SECTION KEYED NOTES O 1. REFER TO ROOF PLAN FOR ROOF SYSTEM, TYPICAL. milli 2. DIESCORNICE. SOLDIER . 3. SOLDIER COURSE —MODULAR BRICK VENEER. 4. ARCHITECTURAL PRECAST STONE PANEL. SEE EXTERIOR ELEVATIONS FOR JOINTS. 5. CONCRETE SLAB ON GRANULAR FILL AND VAPOR BARRIER. REFER TO STRUCTURAL DRAWINGS FOR MORE INFORMATION. FABC AWNING. B. VERSET A STONE PANEL BY BORAL. PROVIDE WIRE PER C U R R A N MANUFACTURERS DETAILS. B. METAL STUD FRAMED EXTERIOR WALL. SEE STRUCTURAL A R C H I T E C T U R E DRAWINGS FOR ALL CONNECTIONS TO STRUCTURAL FRAME. FILL ALL EXTERIOR WALLS WITH MINIMUM R-21 BATT 5719 LAWFON LOOP E. DR. #212 INSULATION. PROVIDE 6 MIL VAPOR BARRIER INTERIOR SIDE INDIANAPOLIS, IN 46216 OF WALL, O 317. 288. 0681 9. EXTRUDED ALUMINUM STOREFRONT OR CURTAINWALL F :: 317. 288 .0753 FRAMING. REFER TO EXTERIOR ELEVATIONS FOR INFORMATION. 10. INTERIOR GYP BOARD TO DECK. 11. SEE STRUCTURAL DRAWINGS. 12. CONCRETE BLOCK VENEER, SEE ELEVATIONS. SEE STRUCTURAL FOR ALL FOUNDATION INFORMATION. 13. 2' RIGID PERIMETER INSULATION. 14. POURED CONCRETE FOOTING, SEE STRUCTURAL. 15. FIRE TREATED EXTERIOR SHEATHING OR GYP SHEATHING AND WEATHER BARRIER. 16. 1-1/2' CONTINUOUS RIGID INSULATION & WEATHER BARRIER, R 7.5 MIN. 17. NOT USED. 18. NOT USED. 19. NOT USED. 20. MODULAR BRICK VENEER. 21. NOT USED. 22. 1' DM. UDDER RUNGS 1'—O" O.C. • 23. UDDER BRACKETS: BENT BAR VERTICAL SPACING. i0 UPRIGHT AT MAX 24" O.C. VERTICAL SPACING. 24. sp' (I X6' CALIF. THRU BOLT W/ FLAT WASHER. TYPICAL. 25, 2X6 F.R. BLOCKING THIS LOCATION FOR UDDER CONNECTIONS. 26. J' EXPANSION MATERIAL AND SEALANT. THIS DRAWING AND THE IDEAS, DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE DKCLUEVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHRECNRE. WPRVI T2019CJRWNA"UECNPE WESTON POINTE RESTAURANT 4425 WESTON POINTE DRIVE CARMEL, INDIANA CARMEL RESUBMITTAL 04.07.17 PERMIT SET 07.17.17 O ADDENDUM 01 09,22.17 Qz PERMIT SET 05.21.19 ,510N poNTE OANE c x Q 170026 0_�� PROJECT WALL SECTIONS I LOCATION IR"= W KEY PLAN A5.5