HomeMy WebLinkAboutA6.1 Door Schedule and ElevationsDOOR SCHEDULE DOOR FRAME DOOR TYPE SIZE MATERIAL THICKNESS GLASS FINISH MATERIAL FINISH TYPE RATING HEAD JAMB SILL HARDWARE REMARKS DOOR # 101 FG 3'-01 ALUM 1 3/4" 1" INSU.. TEMPERED ANODIZED ALUM CLEAR ANODIZED SF1 -- -- -- -- 01 1,2 101 102 F 3'-01 INSUL STL 1 3/4" __ __ HM PAINTED F1 -- -- -- -- 02 3 102 103 FG 3'-0'X7'-0' ALUM 1 3/4" 1' INSU.. TEMPERED ANODIZED ALUM CLEAR ANODIZED SF4 -- -- -- -- 01 1,2 103 104 FG (2)3'-0'X7'-0" ALUM 1 3/4" TEMPERED ANODIZED ALUM pNODAR SF6 -- -- -- -- 03 1,2 104 RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and Local Codes City d Camel DATE: 08/19/19 14 GA c c C TYPE FI FRAME TYPE 2 NOT TO SCALE SEE DOOR SEE DOOR scHr cDULE� scHl EouLE I 16 CA 0 0 go 0 i N O TYPE F TYPE FG DOOR TYPE 94' A" o' A" IJ' 0" IA* -A" R.-A. R' H" STOREFRONT ELEVATIONS 3 NOT TO SCALE SCHED. REMARKS L ALUMINUM STOREFRONT FRAMING WITH DOOR. DOOR IS RESPONSIBILITY OF ALUM. STOREFRONT FRAMING MANUFACTURER AND MUST BE SIZED TO FIT INTO FRAMING AS DETAILED. PROVIDE MEDIUM STILE DOOR, WITH MIN. 10" BOTTOM RAIL FOR ADA COMPLIANCE. 2. SEE STOREFRONT ELEVATIONS FOR FRAME INFORMATION. 3. PROVIDE INSULATED STEEL DOOR AND FRAME. PAINT TO MATCH ADJACENT MATERIALS, COLOR TO BE SELECTED BY ARCHITECT. KEYED NOTES 0 1. OPENING REQUIRED FOR DOOR OR PAIR OF DOORS -SEE FLOOR PLAN FOR DOOR NUMBER, SWING ETC. REFER TO DOOR SCHEDULE FOR DOOR SIZES THAT WILL DETERMINE OPENING REQUIRED. DOORS ARE RESPONSIBILITY OF STOREFRONT FRAMING MANUFACTURER AND MUST COMPLY WITH ALL STATE AND LOCAL ADA CODE REQUIREMENTS. 2. 4 11" X 2' EXTRUDED ALUMINUM STOREFRONT FRAMING SYSTEM. TYPICAL ALL STOREFRONT UNLESS OTHERWISE NOTED. SEE SCHEDULE FOR FINISH. SUPPLIER TO VERIFY WIND LOAD CALCULATIONS AND VERIFY STOREFRONT CONDITION. SHOULD CURTAIN WALL BE REQUIRED, PLEASE NOTIFY ARCHITECT. YKK OR EQUAL. GLAZING TYPES T = SECTION OF GLAZING REQUIRED TO BE TEMPERED - GLASS - USE I" INSULATED TEMPERED GLASS AT EXTERIOR APPLICATIONS, AND )' TEMPERED AT INTERIOR LOCATIONS. IB = SECTION OF GLAZING REQUIRED TO BE I" INSULATED GLASS. lb = SECTION OF GLAZING REQUIRED TO BE )" INSULATED GLASS. GLASS MUST MEET THE FOLLOWING SPECIFICATIONS FOR COMPLIANCE WITH THE ENERGY CONSERVATION CODE FOR ENVELOPE CALCULATIONS: LOW "E" COATING *U" VALUE - O.xx 'SHGC' VALUE - MAXIMUM OF O.xx ALL GLASS TO BE CLEAR HARDWARE HARDWARE SET #01 3 HINGES 1 CUSTOM PULLS (COLRD. W/ TENANT) 1 DEAD BOLT CYLINDER (COORD. CYLINDER LOCATION W/ TENANT) I PUSH BAR INTERIOR I PERIMETER SEAL I LOW PROFILE THRESHOLD I CLOSER I SWEEP HARDWARE SET 4402 3 HINGES (NON PULL HINGE PINS) 1 PANIC BAR 1 HEAVY DUTY LATCH GUARD 1 INTERCHANGEABLE CYLINDER LOCK AND HAND GRIP I LOW PROFILE THRESHOLD I SWEEP I WEATHER STRIPPING 1 18 CA DRIP EDGE :G17.1G11iH7FiPi7 6 HINGES 2 CUSTOM PULLS (COLRD. W/ TENANT) 2 DEAD BOLT CYLINDER (COORD. CYLINDER LOCATION W/ TENANT) 2 PUSH BAR INTERIOR 2 PERIMETER SEAL 2 LOW PROFILE THRESHOLD 2 CLOSERS 2 SWEEPS rim V l PROJECT LOCATION N KEY PLAN CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O 317. 288 .0681 IF :: 317.288.0753 THIS DRAWING AND THE IDEA$ DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCE). WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENTOF CWUN ARCHRECPJRE. O WPY T2019 CVWNAft69iECTURE WESTON POINTE RESTAURANT 4425 WESTON POINTE DRIVE CARMEL INDIANA CARMEL RESUBMITTAL 04.07,17 PERMIT SET 07.17.17 0 PERMIT SET 05.21.19 170026 DOOR SCHEDULE AND STOREFRONT ELEVATIONS