HomeMy WebLinkAboutA6.1 Door Schedule and ElevationsDOOR SCHEDULE
DOOR
FRAME
DOOR
TYPE
SIZE
MATERIAL
THICKNESS
GLASS
FINISH
MATERIAL
FINISH
TYPE
RATING
HEAD
JAMB
SILL
HARDWARE
REMARKS
DOOR #
101
FG
3'-01
ALUM
1 3/4"
1" INSU..
TEMPERED
ANODIZED
ALUM
CLEAR
ANODIZED
SF1
--
--
--
--
01
1,2
101
102
F
3'-01
INSUL STL
1 3/4"
__
__
HM
PAINTED
F1
--
--
--
--
02
3
102
103
FG
3'-0'X7'-0'
ALUM
1 3/4"
1' INSU..
TEMPERED
ANODIZED
ALUM
CLEAR
ANODIZED
SF4
--
--
--
--
01
1,2
103
104
FG
(2)3'-0'X7'-0"
ALUM
1 3/4"
TEMPERED
ANODIZED
ALUM
pNODAR
SF6
--
--
--
--
03
1,2
104
RELEASED FOR CONSTRUCTION
Subject to compliance with all regulations
of State and Local Codes
City d Camel
DATE: 08/19/19
14 GA
c
c
C
TYPE FI
FRAME TYPE 2
NOT TO SCALE
SEE DOOR SEE DOOR
scHr cDULE� scHl EouLE I
16 CA
0 0
go 0
i
N O
TYPE F TYPE FG
DOOR TYPE
94' A" o' A" IJ' 0" IA* -A" R.-A. R' H"
STOREFRONT ELEVATIONS 3
NOT TO SCALE
SCHED. REMARKS
L ALUMINUM STOREFRONT FRAMING WITH DOOR. DOOR IS
RESPONSIBILITY OF ALUM. STOREFRONT FRAMING
MANUFACTURER AND MUST BE SIZED TO FIT INTO
FRAMING AS DETAILED. PROVIDE MEDIUM STILE DOOR,
WITH MIN. 10" BOTTOM RAIL FOR ADA COMPLIANCE.
2. SEE STOREFRONT ELEVATIONS FOR FRAME INFORMATION.
3. PROVIDE INSULATED STEEL DOOR AND FRAME. PAINT TO
MATCH ADJACENT MATERIALS, COLOR TO BE SELECTED BY
ARCHITECT.
KEYED NOTES 0
1. OPENING REQUIRED FOR DOOR OR PAIR OF DOORS -SEE
FLOOR PLAN FOR DOOR NUMBER, SWING ETC. REFER TO
DOOR SCHEDULE FOR DOOR SIZES THAT WILL DETERMINE
OPENING REQUIRED. DOORS ARE RESPONSIBILITY OF
STOREFRONT FRAMING MANUFACTURER AND MUST COMPLY
WITH ALL STATE AND LOCAL ADA CODE REQUIREMENTS.
2. 4 11" X 2' EXTRUDED ALUMINUM STOREFRONT FRAMING
SYSTEM. TYPICAL ALL STOREFRONT UNLESS OTHERWISE
NOTED. SEE SCHEDULE FOR FINISH. SUPPLIER TO VERIFY
WIND LOAD CALCULATIONS AND VERIFY STOREFRONT
CONDITION. SHOULD CURTAIN WALL BE REQUIRED, PLEASE
NOTIFY ARCHITECT. YKK OR EQUAL.
GLAZING TYPES
T = SECTION OF GLAZING REQUIRED TO BE TEMPERED -
GLASS - USE I" INSULATED TEMPERED GLASS AT EXTERIOR
APPLICATIONS, AND )' TEMPERED AT INTERIOR LOCATIONS.
IB = SECTION OF GLAZING REQUIRED TO BE I" INSULATED
GLASS.
lb = SECTION OF GLAZING REQUIRED TO BE )" INSULATED
GLASS.
GLASS MUST MEET THE FOLLOWING SPECIFICATIONS FOR
COMPLIANCE WITH THE ENERGY CONSERVATION CODE FOR
ENVELOPE CALCULATIONS:
LOW "E" COATING
*U" VALUE - O.xx
'SHGC' VALUE - MAXIMUM OF O.xx
ALL GLASS TO BE CLEAR
HARDWARE
HARDWARE SET #01
3 HINGES
1 CUSTOM PULLS (COLRD. W/ TENANT)
1 DEAD BOLT CYLINDER
(COORD. CYLINDER LOCATION W/ TENANT)
I PUSH BAR INTERIOR
I PERIMETER SEAL
I LOW PROFILE THRESHOLD
I CLOSER
I SWEEP
HARDWARE SET 4402
3 HINGES (NON PULL HINGE PINS)
1 PANIC BAR
1 HEAVY DUTY LATCH GUARD
1 INTERCHANGEABLE CYLINDER LOCK AND
HAND GRIP
I LOW PROFILE THRESHOLD
I SWEEP
I WEATHER STRIPPING
1 18 CA DRIP EDGE
:G17.1G11iH7FiPi7
6 HINGES
2 CUSTOM PULLS (COLRD. W/ TENANT)
2 DEAD BOLT CYLINDER
(COORD. CYLINDER LOCATION W/ TENANT)
2 PUSH BAR INTERIOR
2 PERIMETER SEAL
2 LOW PROFILE THRESHOLD
2 CLOSERS
2 SWEEPS
rim
V l PROJECT
LOCATION
N
KEY PLAN
CURRAN
ARCHITECTURE
5719 LAWTON LOOP E. DR. #212
INDIANAPOLIS, IN 46216
O 317. 288 .0681
IF :: 317.288.0753
THIS DRAWING AND THE IDEA$ DESIGNS
AND CONCEPTS CONTAINED HEREIN ARE
THE EXCLUSIVE INTELLECTUAL PROPERTY
OF CURRAN ARCHITECTURE, AND ARE NOT
TO BE USED OR REPRODUCE). WHOLE OR
IN PART, WITHOUT THE WRITTEN
CONSENTOF CWUN ARCHRECPJRE.
O WPY T2019 CVWNAft69iECTURE
WESTON POINTE
RESTAURANT
4425 WESTON POINTE DRIVE
CARMEL INDIANA
CARMEL RESUBMITTAL 04.07,17
PERMIT SET 07.17.17
0 PERMIT SET 05.21.19
170026
DOOR SCHEDULE AND
STOREFRONT ELEVATIONS