Loading...
HomeMy WebLinkAboutE0.1 Electrical Panel SchedulesPANEL NAME CIRCUIT BREAKER REMARKS PANEL CHARACTERISTICS CIRCUIT BREMER TYPE/ACCESSORY OPTIONS MD P CC -CONTROLLED CIRCUIT, EX -EXISTING LOAD TO REMAIN, W.-MODIFIED LOAD ON EXISTING BREAKER, CL SIRCUIT WIRED THROUGH CURRENT LIMITER 800 BUS 800 MCB 208 / 120 35K AIC A-AFCI, S-SHUNT TRIP, H-HACR G=GFCI L= GIB LOCK HT -HANDLE TIE NB=WEN CIRCUIT BREAKER MOUNTING SURFACE 3 - 4 -W BUS MATENIAL COPPER Ckt No Breaker LOAD DESCRIPTION Load Type Load VA PM1asin9 Load VA Load Typa LOAD DESCRIPTION Breaker Ck6 No (Remarks) L1 L2 L9 (Remarks) 1 9013 RTU-1 M 8,166 200 X LIGHITNG CONTROL 2011 L 2 3 M M 8,166 8,166 210 180 L R EXTERIOR BUILDING LIGHTS WAG RECEPT 2011 2011 4 6 5 ] 20/1 SPARE X 200 X FACP 2011 B 9 2011 SPARE X 180 R GENERAL REC 2011 10 11 2011 SPARE X X SPARE 2011 12 13 2011 SPARE X X SPARE 2011 14 15 2011 SPARE X X SPARE 2011 16 17 2011 SPARE X X SPARE 2011 10 19 2011 SPARE X X SPARE 2011 20 21 2011 SPARE X X SPARE 20/1 22 23 2011 SPARE X X SPARE 2011 24 25 2011 SPARE X X SPARE 20/1 26 27 2011 SPARE X X SPARE 2011 28 29 20/1 SPARE X % SPARE 20/1$42 31 20/1 SPARE X X SPARE 2011 39 20/1 SPARE X X SPARE 2011 95 2011 SPARE X X SPARE 2011 3] 2011 SPARE X X SPARE 20/1 39 2011 SPARE X X SPARE 20/1 41 2011 SPARE X X SPARE 2011 PANEL NOTES: NO SUBFEED LOAD SUBFEED LUGS Track (FT) Lengg Total Lighting Load •L" WA g 0.21 Total Connected Load in WA - Phase A Total Track lightingLoad '0" ]KVA) 0.36 d70.7 Total Connected Load in KVA - Phase B Show h (FTM Show W Length (FT) Total le Load •R" (KVA) 0.00 Total Connected Load in KVA - Phase C how Window Total Show Window Load 'C" (KVA) Total Connected Load in KVA -All Phases Mlaa LOBtl DeKdntl % 1.00 Total Motor Load 'M" (KVA) 4.6 2.00 Total Connected LLoa 1n Mpa Tofel Electric Heat Loatl 'H" (KVA) 0.40 Total NEC Demand Loatl in KVA -All PM1aaea Total Load 'X" (KVA) 0.00 Total NEC Demand Load In Pnps ance Kitchen Appliance Load 'K" (KVA) 0.00 GROUNDED CONDUCTOR (NEUTRAL) FROM UTILITY COMPANY TRANSFORMER SERVICE GROUNDED OR NEUTRAL BUS GROUNDING ELECTRODE CONDUCTOR (N2 /0) PER NEC 250.66.� BONDING JUMPER PER NEC 250.102.IC)11 )� METAL FRAME OF BUILDING STRUCTURE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City yUoof Cancel �VT�VI�OwVAWML DATE: \\ 08/19/19 CONNECTION (TYPICAL) CONCRETE ENCASED ELECTRODE (REINFORCING STEEL) CONNECTOR LISTED FOR PURPOSE NON-METALLIC PROTECTIVE SLEEVE WITHIN 5' OF WATER ENTRANCE TO BUILDING 1G' n 10' �10'� INCOMING CONDUIT GROUND (IF STEEL CONDUIT) EQUIPMENT GROUNDING BUS EQUIPMENT BONDING JUMPER ENCLOSURE GROUND MAIN BONDING JUMPER (#210) PER NEC 250.102.(C)(1). #6 AM MINIMUM 10' X 2' X 1 /4' COPPER GROUND BAR. INSTALL ON TELEPHONE BACKBOARD WITH (2) UL LISTED STANDOFF INSULATORS. BONDING JUMPER SOURCE (DIRECT CONTACT WITH EARTH FOR 10OR MORE) COPPER CLAD STEEL, 10' x 3/4' WITH TOP OF ROD 6' BELOW FINISH GRADE (TYPICAL) CLAMPS SUITABLE FOR DIRECT BURIAL (TYPICAL) 3 SERVICE GROUNDING AND BONDING DETAIL E-0.1 SCALE: NONE ELECTRICAL LOAD SUMMARY LOAD DESCRIPTION KW (CONNECTED) NEC DEMAND KW (DEMAND) Total Lighting Load "L" 0.21 125% 0.26 Total Track lighting Load '0' 0 FT 0.00 NEC 0.00 Total Receptacle Load •R• 0.36 NEC 0.36 Total Show Window Load "C" 0 FT 0.00 NEC 0.00 Total Motor Load "K" 24.50 100% 24.50 Total Electric Heat Load "W 0.00 t00% 0.00 Total Mike Load -X- 0.40 100% 0.40 KUolen Appliance Load "K" 0.00 65% 0.00 FUTURE LOAD D.00 T00% 0.00 TOTAL LUAU INS) 26.47 25.62 TOTAL LOAD (AMPS) 70.7 70.9 GYPSUM W `INTUMESCENT FIREST METALLIC CONDUIT DEPTH AS REWIRED MANUFACTURER 1 OR 2 HOUR RATED ILL #WL1001 2250A 120/208V PAD MOUNTED UTILITY TRANSFORMER EXTERIOR ITERANT 2 RUNS OF (4)#500KCMIL5(1)#2/OGND-(2)3'C F=295235(MAX) PANEL MAP. SODA NICE 120/208V #2/0 F=295504(WX) 2 RUNS OF (4)#500KOMIL,(1)#2/OGND-(2)3'C 1 ONE LINE DIAGRAM SECA SCALE: NONE MOP-2 1 OUTDOOR PHOTOSENSOR; FACE NORTH 3/C #18 LV CABLE ZONE SCHEDULE: 1. BUILDING MOUNTED LIGHTING; PS ON, PS OFF RELAY PANEL WITH INTEGRATED DIGITAL TIME CLOCK, 8 LIGHTING RELAYS, WITH RELAY CONTROL CARD FOR MANUAL CONTROL OF ZONES OR INDIVIDUAL RELAYS. EATON LITEREEPER LK8 OR EQUAL. BLDG MU EXT. LIGHTS SPARE SPARE SPARE SPARE SPARE SPARE SPARE 2 LIGHTING CONTROL DIAGRAM (PACKAGED) ISOA SCALE: NONE PROVIDE WIRING PER - MANUFACTURER'S INSTALLATION DRAWING (TYR) SIGNALING LOOP V SYNCHRONIZING MODULE - PROVIDE TELEPHONE - LINE TO TERMINAL BOARD FOR CITY TIE-IN OR OFF -SITE I) SEALANT, MONITORING. IY HE PROVIDE TELEPHONE - LINE FOR SECONDARY OFF -SITE MONITORING. 4 IFIRESTOP FOR METALLIC CONDUIT E-0.1 SCALE: NONE �. r 18' FINISHED OWE FINISHED GRADE MIN MIN.) � � �`�' \� TRENCHING AND SELECT CLEAN \ / BACKFILL TO 95% COMPACTION BY E.0 y 7 y ay TRENCHING AND SELECT CLEAN A y ��.( �� RED MARKER 12' ��- MORFILL TO 95% COMPACTION BYE C. d �J\ \ R - TAPE 'ELECTRICAL' 24' c�c c -i / y . 300 i 4•SCHEDULE 40 (MIN.) /�///�/l ��`���L<* RED MARKER MIN. CONDUITS (TYPICAL) °i_,� A �i/ q y �, 32• SCHEDULE 40 -< %L -2 //'�' TAPE A . (MIN.) CONDUITS (TYPICAL) ^'; ,/ 'ELECTRICAL' / J 5. L= BASE SPACER ON j -I 5'-0' MAX. CENTERS ^ _ 4 EwiH 5 PRIMARY POWER DUCT BANK DETAIL EE0.1 SCALE: NONE 6 UNDERGROUND CONDUIT DETAIL E-0.1 SCALE: NONE 2#12 MG, 1#12 AN END, 3/4-C. Mi 20A/1P PROVIDE MONITOR MODULE FOR REQUIRED FUNCTION (TYPICAL). FACP FIRE ALARM CONTROL PANEL SURFACE MOUNTED, LOCATED IN TENANT SPACE (VERIFY LOCATION PRIOR TO ROUGH -IN). (DACT REQUIRES TWO ACTIVE PHONE LINES). FIRE ALARM DETAIL NOTES -SEE KITCHEN HGOD BLOCK DIAGRAM FOR ADDITIONAL REQUIREMENTS. PROVIDE WIRING AND RELAY REQUIRED TO SHUTDOWN TENANT SOUND SYSTEM UPON FIRE ALARM ACTIVATION, PROVIDE WIRING TO STARTERS FOR FAN SHUTDOWN. PROVIDE WIRING TO EACH SECURITY DOOR MAG LOCI( POWER SUPPLY LOCATION FOR UNLOCKING OF SECURITY DCORS DURING FIRE ALARM CONDITION. (COORDINATE WITH SECURITY SYSTEM SUPPLIER). 1 THIS DIAGRAM REPRESENTS A TYPICAL SYSTEM AND IS NOT INTENDED FOR INSTALLATION. SYSTEM SUPPLIER SHALL PROVIDE INSTALLATION DRAWINGS AND SCHEMATIC WIRING DIAGRAMS. EXACT SYSTEM REQUIREMENTS SHALL BE COORDINATED WITH THE SYSTEM SUPPLIER. SYSTEM INSTALLER SHALL BE NICET CERTIFIED, IF REQUIRED BY LOCAL AUTHORITY HAVING JURISDICTION. 2 SYSTEM SUPPLIER SHALL SUPERVISE INSTALLATION, PROGRAM AND TEST SYSTEM AND INSTRUCT OYNER ON SYSTEM OPERATION. 3 ALL FIRE ALARM WIRING SHALL BE PLENUM RATED. EXPOSED FIRE ALARM WIRING, 10'-0- AFF AND BELOW, SHALL BE INSTALLED IN CONDUIT TO ABOVE ACCESSIBLE CEILING SPACE OR STRUCTURE. 4 ALL CONTROL CABINETS SHALL BE GROUNDED PER NEC REQUIREMENTS AND PER SPECIFICATIONS. S. COORDINATE CITY TIE-IN REQUIREMENTS WITH LOCAL AUTHORITY. 6 DUCT SMOKES ARE FURNISHED AND WIRED BY EC, AND INSTALLED PER CODE BY MC. 7 ALL FIRE ALARM DEVICES SHALL BE INSTALLED IN ACCORDANCE WITH INFRA 72 & 'ADA' 7 ADDRESSABLE FIRE ALARM SYSTEM TYPICAL WIRING DIAGRAM EE0.1 SCALE: NONE CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O e 317. 288 . 068 1 IF :: 317.288.0753 DRAWN BY: JTK CHI EJR GTIE/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 8712410 F 440 871 7954 tesengineering.com 6 =�N T.•_ T�.. STATE OF i 4/� ' F P'•.ND I AN v?.: D N Alll1��? \ THIS DRAWING AND THE IDEA$ DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED. WHOM OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. cpPmlou20'e, CIRMWx TaruR_ WESTON POINTE RESTAURANT WESTON POINTE DRIVE NORTH MICHIGAN ROAD CARMEL, INDIANA ELECTRICAL PANEL SCHEDULES & DETAILS M' CARMEL RESUBR PERMIT SET ADDENDUM 1 ADDENDUM 2 PERMIT SET 170026 E=0. I