Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E0.2 Electrical Legend
Fill me] ]fl:001[10 A AMP, AMPERES ADA AMERICANS WITH DISABILITIES ACT AFC ABOVE FINISHED CEILING ARE ABOVE FINISHED FLOOR AEG ABOVE FINISHED GRAVE ANSI AMERICAN NAT'L STANDARDS INSTITUTE ARCH ARCHITECT, ARCHITECTURAL AUX AUXILIARY AWG AMERICAN WIRE GAUGE AN AUDIOIVISUAL RAS BUILDING AUTOMATION SYSTEM BE BREAKER BLDG BUILDING BUS BUILDING MANAGEMENT SYSTEM C CONDUIT CATV CABLE TELEVISION SYSTEM C/B CIRCUIT BREAKER COTV CLOSED CIRCUIT TELEVISION OEM CUBIC FEET PER MINUTE CRT CIRCUIT CT CURRENT TRANSFORMER MG CEILING CW GOLD WATER D DEEP, DEPTH DUCT DIGITAL ALARM COMMUNICATING TRANSMITTER dB DECIBEL DOC DIRECT DIGITAL CONTROL 0 DELTA DIA DIAMETER DISC DISCONNECT ON DOWN DWG DRAWING EC ELECTRICAL CONTRACTOR IF EXHAUST FAN ETR EXISTING TO REMAIN EMT ELECTRICAL METALLIC TUBING EWC ELECTRICAL WATER COOLER EM EXHAUST EX, EXIST EXISTING FA FIRE ALARM FACP FIRE ALARM CONTROL PANEL FARA FIRE ALARM REMOTE ANNUNCIATOR FLA FULL LOAD AMPS FPO FIRE PROTECTION CONTRACTOR FT FOOT, FEET G,GRD GROUND GC GENERAL CONTRACTOR GFI, GFIC GROUND FAULT INTERRUPTER HID HIGH INTENSITY DISCHARGE HTR HEATER HVAC HEATING, VENTILATING & A/C IBC INTERNATIONAL BUILDING OODE IN INCH, INCHES KVA KILOVOLT -AMPS KW KILOWATTS KWH KILOWATT-HOUR L LENGTH LED LIGHT EMITTING DIODE LRA LOCKED ROTOR AMPS LTG LIGHTING MAX MAXIMUM ITC MECHANICAL CONTRACTOR MCA MINIMUM CIRCUIT AAPACITY MCB IMIN CIRCUIT BREAKER MOO MOTOR CONTROL CENTER M:CH MECHANICAL MI METAL HALIDE MIN MINIMUM Ml MAXIMUM OVER CURRENT PROTECTION MUA MAKE UP AIR IUD MOUNTED N/A NOT APPLICABLE N.C. NORMALLY CLOSED NEC NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MFN'S ASSOC. NFPA NATIONAL FIRE PROTECTION ASSOC, NIC NOT IN CONTRACT N.O. NORMALLY OPEN NTS NOT TO SCALE OC ON CENTER GIN OVERHEAD OSHA OCCUPATIONAL SAFETY &HEALTH ADMIN. P POLE PB PUSH BUTTON PC PLUMBING CONTRACTOR PF POWER FACTOR PH PHASE PVC POLYVINYL CHLORIDE RCP REFLECTED CEILING PLAN REV REVISION REX REMOVE EXISTING ROS RIGID GALVANIZED STEEL III RUNNING LOAD AMPS RM ROOM RR REMOVE AND RELOCATE RTU ROOF TOP UNIT BE SERVICE ENTRANCE SF SQUARE FEET, SQUARE FOOT THRU THROUGH TRANS TRANSFORMER TYP TYPICAL TIC TIME CLOCK US UNDERGROUND UL UNDERWRITERS LABORATORIES, INC. WIN UNLESS OTHERWISE NOTED UPS UNINTERRUPTED POWER SUPPLY VA VOLT-AMPERE W WATT, WIDTH W/ WITH WP WEATHERPROOF XFMi TRANSFORMER Y WE RELEASED FOR CONSTRUCTION Subject to compliance with all regulations of State and meal Codes City of Camel �VT�MD'�G*T41WML DATE: \ 08/19/19 ELECTRICAL SYMBOLS (ALL SYMBOLS SHOWN ARE NOT NECESSAA ILLY USED ON THE DRAWINGS) 35 HOMERUN #12 TO PANEL 'A' CIRCUIT #1 3 5 VIA 2GROUN GROUNDING CON UCTOR RS , ,A TWO #12 CONDUCTORS (MINIMUM SIZE), RWIN.EFER A GROUNDING CONDUCTOR SHALL BE PROVIDED IN ALL OONMENTS. REFER TO SPECIFICATIONS FOR ADDITIONAL GROUNDING REQUIREMENTS. - - - - INFLOOR/UNDERFLOOR CONDIIT/WIRE CIRCUITRY TURNING UP PANELBOARD - 208Y/120 VOLT, 305 4 WIRE PANELBOARD - MOY/277 VOLT, 305 4 WIRE TELEPHONE FIRE RATED PLYWOOD BACKBOARD - SIZE INDICATED ON PLAN O JUNCTION COX DISCONNECT SWITCH UNFUSED DISCONNECT SWITCH FUSED: 'AS' - INDICATES AMPERE SWITCH SIZE 'AF' - INDICATES AMPERE FUSE SIZE ® MY TYPE TRANSFORMER DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18' AFF UNLESS OTHERWISE NOTED: '2' INDICATES CIRCUIT NUMBER "C" INDICATES MOUNTED 8" ABOVE COUNTER "54" INDICATES 54' ARE All INDICATES WEATHERPROOF COVER "IG" INDICATES ISOLATED GROUND TYPE 'GFI' INDICATES GROUND FAULT CIRCUIT INTERRUPTER TYPE DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, GROUNDING TYPE, 20 AMPERE, MOUNTED AT 18' AFF UNLESS OTHERWISE NOTED. SINGLE (SIMPLEX) RECEPTACLE, TYPE AND MOUNTING AS INDICATED ON THE DRAWINGS. DUPLEX RECEPTACLE - 125 VOLT 2 POLE 3 WIRE 20 AMPERE MOUNTED IN FLOOR BOX. ® DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN CEILING. ®p COMBINATION DUPLEX RECEPTACLE AND VOICE/DATA OUTLET MOUNTED IN FLOOR BOX. ® DOUBLE DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE MOUNTED IN FLOOR BOX. O POWER POLE Qw FIRE RATED POKETHROUGHDEVICE 'P' INDICATES DUPLEX RECEPTACLE - 125 VOLT, 2 POLE, 3 WIRE, 20 AMPERE 'T' INDICATES TELEPHONE/DATA $ SWITCH - SINGLE POLE TOGGLE TYPE - 120J277 VOLT, 1-HP RATED, 20 AMPERE, MOUNTED AT 48' AFF UNLESS OTHERWISE NOTED: "3" INDICATES THREE WAY SWITCH "4" INDICATES FOUR WAY SWITCH "C" INDICATES SWITCH MOUNTED 8' ABOVE COUNTER "a" INDICATES SWITCHED FIXTURE CONTROL "OS" INDICATES DUAL TECHNOLOGY OCCUPANCY SENSOR SWITCH "D" INDICATES DIMMER SWITCH - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR 'DF' INDICATES FLUORESCENT DIMMER SWITCH - WATTAGE AS INDICATED ON PANEL SCHEDULE. EACH BRANCH CIRCUIT SHALL INCLUDE A SEPARATE NEUTRAL CONDUCTOR OS SWITCH - DUAL TECHNOLOGY, CEILING MOUNTED - SINGLE POLE, TOGGLE TYPE - 120/277 VOLT, 20 AMPERE '3' INDICATES THREE WAY SWITCH '4' INDICATES FOUR WAY SWITCH �13 LIGHT FIXTURE: 'A' INDICATES FIXTURE TYPE, '13' INDICATES CIRCUIT a NUMBER, 'a' INDICATES SWITCH O NTROL. REFER TO LUMINAIRE SCHEDULE A FOR DESCRIPTION. LIGHTING FIXTURE WITH 1 BALLAST WIRED TO EMERGENCY AND/OR NIGHT LAIIIII NL LIGHTING COT. ILLUMINATED 'EXIT' SIGN LIGHTING FIXTURE. CEILING MOUNTED OR WALL MOUNTED. PROVIDE DIRECTIONAL ARROWS AS INDICATED ON FLOOR PLANS. a D REMOTE EMERGENCY WEATHERPROOF LIGHTING HEAD SUPPLIED FROM REMOTE Y BATTERY UNIT. EMERGENCY LIGHTING BATTERY UNIT WITH HEADS AS INDICATED. TC TIME CLOCK COMBINATION VOICE/DATA OUTLET - MOUNTED AT 18' AFF UNLESS OTHERWISE NOTED. PROVIDE SINGLE GANG BOX WITH PLASTER RING AND 3/4' CONDUIT TO ABOVE THE ACCESSIBLE CEILING. 'W' INDICATES WALL MOUNTED AT 54' AFF, 'C' INDICATES MOUNTED 8' ABOVE COUNTER. O DATA OUTLET MOUNTED IN FLOOR BOX DOOR BUZZER DOOR BELL ❑' PUSHBUTTON FACP FIRE ALARM CONTROL PANEL ARA FIRE ALARM REMOTE ANNUNCIATOR ❑F FIRE ALARM MANUAL PULL STATION MOUNTED AT 48' ARE. DI FIRE ALARM AUDIO/VISUAL ALARM SIGNAL WALL MOUNTED AT 80' AFF. FIRE ALARM VISUAL ONLY ALARM SIGNAL WALL MOUNTED AT 80' AFF. SD FIRE ALARM PHOTOELECTRIC SMOKE DETECTOR SD FIRE ALARM DUCT MOUNTED SMOKE DETECTOR WITH SAMPLING TUBE, FURNISHED AND WIRED BY EC, MOUNTED BY MC. © REMOTE ANNUNCIATOR LIGHT/AUDIBLE ALARM FOR DUCT SMOKE DETECTOR HD FIRE ALARM HEAT DETECTOR CM FIRE ALARM CARBON MONOXIDE DETECTOR TS TAMPER SWITCH FS FLOW SWITCH FK_Hl KITCHEN HOOD SUPPRESSION SYSTEM TFP1 FIRE PUT' CONTROL PANEL ELECTRICAL SPECIFICATIONS DIVISION 26 - ELECTRICAL I. GENERAL PROVISIONS A. GENERAL CONDITIONS, CODES & STANDARDS 1. GENERAL CONDITIONS OF THE CONTRACT FOUND IN THE ARCHITECTURAL DRAWINGS, GENERAL AND SPECIAL CONDITIONS OF THE AMERICAN INSTITUTE OF ARCHITECTS (AIA) AND MY OF THE OWNER'S GENERAL REQUIREMENTS SHALL APPLY UNLESS NOTED OTHERWISE. 2. REFER TO THE GENERAL CONDITIONS ON THE ARCHITECTURAL DOCUMENTS AND THE GENERAL AND SPECIAL CONDITIONS OF THE AIA FOR ADDITIONAL REQUIREMENTS REGARDING; SAFETY, COORDINATION & COOPERATION, WORKMANSHIP, PROTECTION, CUTTING AND PATCHING, DAMAGE TO OTHER WORK, PRELIMINARY OPERATIONS, STORAGE, ADJUSTMENTS, CLEANING, ETC. 3. ALL WORK SHALL BE IN CONFORMANCE WITH ALL LOCALLY ENFORCED, FEDERAL, STATE, AND LOCAL CODES AND ORDINANCES INCLUDING ANY SPECIAL THE OWNER REQUIREMENTS IN ADDITION TO THOSE SPECIFIED. 4. CONTRACTOR SHALL PAY FOR AND OBTAIN ALL NECESSARY LICENSES, PERMITS AND INSPECTIONS REQUIRED TO PROCEED WITH THE WORK. THIS SHALL INCLUDE ALL REQUIRED COORDINATION WITH THE LOCAL UTILITY COMPANIES AND THEIR ASGOCIATED FEES OR COSTS. S. ALL EQUIPMENT AND MATERIALS USED SHALL BE NEW AND UL LISTED FOR THE APPLICATION, AND SHALL BEAR AN APPROPRIATE UL LABEL. B. SCOPE OF WORK 1. THIS CONTRACT SHALL INCLUDE THE FURNISHING, INSTALLING, CONNECTING, AND OPERATION OF ALL EQUIPMENT WHICH IS A PART OF THE ELECTRICAL SYSTEMS AS SHOWN ON THE DRAWINGS AND AS REQUIRED BY SIMILAR INSTALLATIONS. ANY MATERIAL OR LABOR WHICH IS NEITHER SHOWN ON THE DRAWINGS NOR CALLED FOR IN THE SPECIFICATIONS, BUT WHICH IS OBVIOUSLY NECESSARY TO COMPLETE THE WORK AND WHICH IS USUALLY INCLUDED IN WORK OF A SIMILAR CHARACTER SHALL BE FURNISHED AND INSTALLED UNDER THIS CONTRACT AT NO ADDITIONAL COST TO THE OWNER. CONTRACTOR SHALL PROVIDE ALL LABOR AND MATERIALS REQUIRED TO PROVIDE THE OWNER A COMPLETE, CODE APPROVED AND OPERATIONAL ELECTRICAL SYSTEM. 2. CAREFULLY READ SPECIFICATION FOR ALL PARTS OF THE WORK SO AS TO BECOME FAMILIAR WITH ALL TRADES' WORK SCOPE. CONSULT WITH OTHER TRADES TO INSURE PROPER LOCATIONS AND AVOID INTERFERENCES. ANY CONFLICT SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER BEFORE WORK IS COMMENCED. 3. CONTRACTORS SHALL BE HELD TO HAVE EXAMINED THE PREMISES AND SITE SO AS TO COMPARE THEM WITH THE DRAWINGS AND SPECIFICATIONS, NOTE THE EXISTING CONDITIONS AND OTHER WORK THAT WILL BE REQUIRED, AND THE NATURE OF THE CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. NO ALLOWANCE SHALL BE MADE TO THE CONTRACTOR BY REASON OF THIS FAILURE TO HAVE MADE SUCH EXAMINATION OR OF ANY ERROR ON HIS PART. 4. ALL EXISTING UTILITY AND ELECTRICAL SERVICES SHALL BE FIELD VERIFIED. CORRECTIONS TO THE DESIGN AND INSTALLATION SHALL BE MADE WITHOUT ADDITIONAL COST TO THE OWNER. S. PROVIDE ALL CUTTING AND PATCHING REQUIRED FOR INSTALLATION OF ELECTRICAL WORK. ALL CORE DRILLING OR CUTTING OF FIRE RATED FLOORS, SHAFTS, AND WALLS SHALL BE FIRESTOPPED PRIOR TO FINISH PATCHING. ALL PENETRATIONS SHALL BE FIRE SEALED TO MATCH THE FIRE RATING OF THE FLOORS, SHAFTS, AND WALLS PENETRATED. 6. TEMPORARY ELECTRICAL SERVICE, LIGHTING, AND RELATED WIRING SHALL BE PROVIDED TO OSHA REOUIREM:NTS FOR THE USE OF ALL TRADES DURING CONSTRUCTION. 7. TEMPERATURE AND INTERLOCK CONTROL COMPONENTS AND ALL RELATED WIRING AND CONDUIT SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE INDICATED ON THE DRAWINGS. 9. ALL WORK INCLUDING, BUT NOT LIMITED TO PARTS, MATERIAL, EQUIPMENT AND LABOR SHALL BE GUARANTEED FOR ONE YEAR AFTER ACCEPTANCE BY THE ENGINEER AND OWNER. WHERE AN EQUIPMENT MANUFACTURER HAS A WARRANTY THAT EXCEEDS ONE YEAR, THAT WARRANTY PERIOD SHALL APPLY TO THIS PROJECT. C. DOCUMENTS 1. THE DRAWINGS ARE DIAGRAMMATIC; ALL WORK SHALL BE PERFORMED AS INDICATED ON THE DRAWINGS UNLESS EXISTING CONDITIONS OR COORDINATION ISSUES REQUIRE CHANGES. THESE CHANGES SHALL BE MADE WITH NO ADDITIONAL COST TO THE OWNER. 2. ANY INCIDENTAL ITEMS OR LABOR, ETC. NOT INCLUDED IN THE SPECIFICATIONS OR THE DRAWINGS BUT REASONABLY IMPLIED AS NECESSARY FOR THE COMPLETE INSTALLATION OF ALL APPARATUS SHALL BE INCLUDING IN BID. 3. THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO SUPPLEMENT EACH OTHER AND ANY MATERIAL OR LABOR CALLED FOR IN ONE SHALL BE FURNISHED EVEN THOUGH NOT MENTIONED IN BOB. 4. IF ERRORS ARE FOUND IN THE DRAWINGS OR SPECIFICATIONS OR DISCREPANCIES OCCUR BETWEEN THE SAME, OR BETWEEN THE FIGURES ON THE DRAWINGS, AND THE SCALE OF SAME OR BETWEEN THE LARGER AND SMALLER DRAWINGS, OR IN THE DESCRIPTIVE MATTER ON THE DRAWINGS SHALL BE REFERRED TO THE OWNER FOR REVIEW AND FINAL DECISION PRIOR TO THE BID DUE DATE. S. THE BIDDING OF THIS WORK WILL CONTEMPLATE THE USE OF EQUIPMENT AND MATERIALS EXACTLY AS SPECIFIED HEREIN. WHERE MORE THAN ONE MANUFACTURER IS MENTIONED ANY ONE MAY BE UTILIZED. SUBSTITUTE MANUFACTURERS MAY BE OFFERED ONLY AS AN ALTERNATE TO THE SPECIFIED EQUIPMENT AND MATERIAL AND MUST BE SUBMITTED AS SPECIFIED IN THE ARCHITECTURAL DOCUMENTS. 6. MISCELLANEOUS ITEMS NECESSARY TO COMPLETE THE SYSTEMS CAN BE OF ANY RECOGNIZED MANUFACTURE PROVIDED THESE ITEMS MEET MINIMUM STANDARDS AS SET IN THESE SPECIFICATIONS. REFER TO EACH SECTION FOR ANY SPECIFIC REQUIREMENTS. D. COORDINATION 1. CONTRACTOR SHALL LOCATE, IDENTIFY AND PROTECT ANY EXISTING SERVICES YMICH ARE REQUIRED TO BE MAINTAINED OPERATIONAL AND SHALL EXERCISE EXTRA CAUTION IN THE PERFORMANCE OF ALL WORK TO AVOID DISTURBING SUCH FACILITIES. ALL COSTS FOR REPAIR OF DAMAGES TO SUCH SERVICES SHALL BE PAID BY THE CONTRACTOR CAUSING THE DAMAGE. 2. EACH CONTRACTOR SHALL BE HELD RESPONSIBLE FOR ALL DAMAGE TO OTHER WORK CAUSED BY HIS WORK OR THROUGH THE NEGLECT OF HIS, OR HIS SUB -TRADE'S PERSONNEL. ALL PATCHING, REPAIRING, REPLACEMENT AND PAINTING, ETC, SHALL BE DONE AS DIRECTED BY THE OWNER BY THE CRAFTSMEN OF THE TRADES INVOLVED. THE COSTS OF SUCH WORK SHALL BE PAID BY THE CONTRACTOR CAUSING THE DAMAGE. 3. IT IS ESSENTIAL THAT ALL WORK AT THE PROJECT BE DONE AT SUCH TIME AND IN SUCH MANNER AS NOT TO INTERFERE WITH THE OPERATIONS OF THE SPACE, ADJACENT SPACES, OR FACILITY. A WORK SCHEDULE SHALL BE ARRANGED WITH THE OWNER, INCLUDING PREMIUM TIME WORK TO FACILITATE WORK WITH A MINIMUM OF INTERFERENCE TO THE OWNER'S OPERATIONS. E. METHODS 1. EXCAVATIONS SHALL BE MADE IN OPEN TRENCHES. FLOORS SHALL BE SAW CUT. CONDUIT SHALL BE LAID ON AN APPROPRIATELY GRADED 6' BED OF CLEAN AND DRY SAND. ENGINEERED FILL SHALL BE USED TO BACKFILL TO 6' ABOVE THE CONDUIT. BACKFILL THE REMAINDER OF THE TRENCH UTILIZING THE EXCAVATED MATERIAL IF APPROVED BY THE ARCHITECT OR THE OWNER. IF THE EXCAVATED MATERIALS ME NOT ACCEPTABLE, ENGINEERED FILL ACCEPTABLE TO THE ARCHITECT SHALL BE UTILIZED TO BACKFILL THE REMAINDER OF THE TRENCH. BACKFILL SHALL BE ACCOMPLISHED IN 9' LIFTS WITH ALL LIFTS OOMPACTED TO 0% PROCTOR. PATCH FLOM TO MATCH EXISTING. 2. EQUIPMENT, CONDUIT, ETC. SHALL NOT BE SUPPORTED FROM MY CEILINGS, OTHER PIPING, OTHER CONDUIT OR DUCTWORK, ROOF DECK, OR JOIST BRIDGING. ITEMS SHALL BE SUPPORTED FROM ACCEPTABLE STRUCTURAL BUILDING COMPONENTS AS DETERMINED BY THE ARCHITECT AND STRUCTURAL ENGINEER. 3. ALL ROOF PENETRATIONS, FLASHINGS AND COUNTER FLASHINGS SHALL BE PERFORMED BY THE OWNER'S ROOFING CONTRACTOR AT THE REQUESTING CONTRACTORS COST. F. SUBMITTALS 1. SHOP DRAWINGS SHALL BE PROVIDED TO THE ARCHITECT OF ALL EQUIPMENT AND ACCESSORIES PROVIDED FOR THE PROJECT WHETHER SPECIFIED HEREINOR ON THE DRAWINGS. REVIEW OF THE SHOP DRAWINGS SHALL BE FOR GENERAL DESIGN CONCEPT AND AIIHERENCE WITH THE SPECIFICATIONS. QUANTITY OF SHOP DRAWINGS SUBMITTED SHALL BE AS SPECIFIED BY THE ARCHITECT. SHOP DRAWINGS SHALL BE PREPARED BY THE CONTRACTOR SHOWING LOCATIONS AND MEASUREMENTS FROM COLUMNS OF ALL CONCEALED AND EXPOSED PIPING, DUCTWORK, CONDUIT, EQUIPMENT, ACCESSORIES, ETC., AND SUBMITTED PRIOR TO INSTALLATION. THE OWNER MAY MAKE REPRODUCIBLE COPIES OF THEIR DRAWINGS AVAILABLE FOR USE IN PREPARATION OF SHOP DRAWINGS, HOWEVER THE OWNER SHALL NOT BE HELD RESPONSIBLE FOR NOT CONFIRMING ALL INFORMATION ON THE DRAWINGS PRIOR TO FABRICATION AND/OR INSTALLATION. 2. PROJECT RECORD DOCUMENTS - MAINTAIN AT THE JOBSITE ONE COPY OF ALL CONTRACT DOCUMENTS CLEARLY WED AS "PROJECT RECORD COPY'. THESE DRAWINGS PALE TO BE MAINTAINED IN GOOD CONDITION, UPDATED DAILY FOR CHANGES ENCOUNTERED AND AVAILABLE AT ALL TIMES FOR INSPECTION BY THE OWNER. DO NOT USE FOR FIELD CONSTRUCTION[ PROJECT RECORD DOCUMENTS ME TO BE KEPT CURRENT WITH EXACT DIMENSIONS OF ALL WORK, EQUIPMENT, DISTRIBUTION CONDUIT, CIRCUITS, ETC. MARK ALL INFORMATION IN RED LINES AND NOTES 80 AS TO BE EASILY IDENTIFIED FROM THE BASE DRAWING. UPON COMPLETION OF THE WORK, ONE SET OF THESE DOCUMENTS SHALL BE TURNED OVER TO THE OWNER AS ONE QUALIFICATION FOR FINAL PAYMENT. 3. THREE COMPLETE SETS OF AS -BUILT DOCUMENTATION SHALL BE PROVIDED. IT SHALL INCLUDE, BUT NOT BE LIMITED TO ACCURATE PLAN DRAWINGS, WIRING DIAGRAMS AND OPERATION AND MAINTENANCE MANUALS. 4. SUBMIT OVERCURRENT DEVICE COORDINATION STUDY INCLUDING EQUIPMENT EVALUATION REPORTS, ONE LINE DIAGRAM, PROTECTIVE DEVICE COORDINATION STUDY AND TIME -CURRENT COORDINATION CURVES. STUDY ELECTRICAL DISTRIBUTION SYSTEM FROM NORMAL AND ALTERNATE POWER SOURCES. THE STUDY SHALL COMPLY WITH IEEE 399 FOR GENERAL STUDY REQUIREMENTS. II. PRODUCTS A. CONDUIT 1. CONDUIT SHALL BE HEAVY WALL RIGID GALVANIZED STEEL WHERE EXPOSED AND SUBJECT TO DAMAGE, 8'-0' ARE AND BELOW, AND IN WET LOCATIONS WHERE INDICATED ON THE DRAWINGS. UNDERGROUND CONDUIT SHALL BE SCHEDULE 40 PVC AND SHALL BE CONCRETE ENCASED S' MINIMUM) WHERE INDICATED ON THE DRAWINGS. A TRANSITION SHALL BE MADE TO HEAVY WALL RIGID GALVANIZED STEEL BEFORE PVC CONDUITS PENETRATE THE FLOOR SLAB. INTERIOR CONDUITS SHALL BE ELECTRICAL METALLIC TUBING (EMT). METAL CLADINC)CABLE MAY BE USED IF APPROVED BY THE OWNER, AND INSTALLED IN LOCATIONS PERMITTED BY CODE. 2. FLEXIBLE METAL CONDUIT SHALL BE USED FROM OUTLET BOX TO INDIVIDUAL RECESSED LIGHT FIXTURES, AND FOR FINAL CONNECTIONS TO MOTORS AND OTHER DEVICES SUBJECT TO VIBRATION. B. CONDUIT FITTINGS AND BOXES 1. INTERIOR OUTLET BOXES SHALL BE STANDARD GALVANIZED SHEET STEEL TYPE, NOT LESS THAN 14 GAUGE IN THICKNESS, WITH KNOCKOUT OPENINGS, EXTENSIONS, PLASTER RINGS AND COVER PLATES TO ACCOMMODATE THE DEVICES INSTALLED. COVER PLATES SHALL BE SMOOTH PLASTIC TO MATCH DEVICE COLOR. USE STEEL PLATES WITH ROUNDED OORNERS FOR SURFACE BOXES. OUTDOOR (WET LOCATION) OUTLET BOXES SHALL BE CAST ALUMINUM TYPE WITH DEVICE COVERS TO SUIT. 2. OUTLET BOXES SHALL NOT BE LESS THAN 4 INCHES SOLARI 1-1/2 INCHES DEEP. 3. OMPLINGS AND CONNECTORS FOR EMT SHALL BE DIE CAST ZINC OR STEEL. BUSHING SHALL BE GROUNDING TYPE WITH INSULATING PLASTIC INSERT. C. WIRE AND CABLE 1. CONDUCTORS FOR POWER AND LIGHTING SHALL BE NEW GOO -VOLT, 90-C, TYPE MN, THHW, OR THWN INSULATION, MINIMUM SIZE #12-AWG, EXCEPT FOR CONTROL WIRING WHICH MAY BE #14-AWG. OTHER SIZES SHALL BE AS NOTED ON THE DRAWINGS. CONDUCTORS SHALL BE COPPER, UNLESS OTHERWISE APPROVED BY THE OWNER. 2. BRANCH CIRCUIT RUNS EXCEEDING 100 FEET IN TOTAL LENGTH FROM THE PANELBOARD TO THE LAST DEVICE, SHALL BE #10-AWG CONDUCTORS UNLESS OTHERWISE NOTED. 3. COMPRESSION TYPE LUGS AND CONNECTORS SHALL BE USED FOR ALL TERMINATIONS AND SPLICES. 4. ALL LOW VOLTAGE COMMUNICATIONS, FIRE ALARM, DATA, SECURITY, TELEPHONE AND ALL OTHER MISCELLANEOUS LOW VOLTAGE WIRING INSTALLED IN CEILING SHALL BE PLENUM RATED. D. WIRING DEVICES 1. DUPLEX RECEPTACLES SHALL BE GROUNDING TYPE, NEMA 5-20R, RATED FOR 20 AMPS, 125 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. 2. SWITCHES SHALL BE TOGGLE OPERATED, QUIET TYPE, RATED FOR 20 AMPS, 120/277 VOLTS, WITH PROVISIONS FOR BACK AND SIDE WIRING. THREE WAY AND FOUR WAY SWITCHES SHALL BE PROVIDED WHERE INDICATED. 3. COLORS OF DEVICES SHALL BE SELECTED BY ARCHITECT. 4. WIRING DEVICES SHALL BE SPECIFICATION GRADE, AS MANUFACTURED BY HUBBELL, PASS & SEYMOUR, ARROW HART, LEVITON AND GENERAL ELECTRIC. E. LIGHTING AND RECEPTACLE PANELBOARDS 1. BRANCH CIRCUIT PANELBOARDS SHALL BE DEAD FRONT TYPE, WITH MAIN LUGS OR MAIN OVERCURRENT DEVICE AS INDICATED, BRANCH OVERCURRENT DEVICES AS NOTED AND AN EQUIPMENT GROUND BAR, ALL IN A SURFACE OR FLUSH MOUNTED SHEET STEEL ENCLOSURE. MINIMUM SHORT CIRCUIT CAPACITY SHALL BE 10,000 AMPS SYMMETRICAL FOR 120/208V, AND 18,000 AMPS SYMMETRICAL FOR 2771480V APPLICATION UNLESS NOTED OTHERWISE. 2. CIRCUIT BREAKERS SHALL BE BOLT ON TYPE; WITH MOLDED PLASTIC CASE; 1, 25 OR 3 POLE AS INDICATED; QUICK -MAKE, QUICK -BREAK; AND THERMAL -MAGNETIC TRIP DEVICE. 3. ALL BREAKERS FEEDING HVAC EQUIPMENT SHALL BE HACK RATED, UNLESS OTHERWISE NOTED. 4. ALL EQUIPMENT RATED LESS THAN 100A SHALL HAVE GO DEGREE C MINIMUM TERMINATIONS. ALL EQUIPMENT RATED 100A OR OVER SHALL HAVE 75 DEGREE MINIMUM TERMINATIONS. S. INDIVIDUAL SINGLE POLE CIRCUIT BREAKERS, WITH IDENTIFIED TIES, OR 213 POLE BREAKERS SHALL BE PROVIDED FOR EACH UNGROUNDED CONDUCTOR IN ALL MULTI -WIRE BRANCH CIRCUITS. 6. PANELBOARDS SHALL BE AS MANUFACTURED BY SQUARE D, GENERAL ELECTRIC, SIEMENS, AND CUTLER HAMMER. F. SAFETY SWITCHES AND MOTOR STARTERS 1. SAFETY SWITCHES SHALL BE FUSIBLE OR NON -FUSIBLE AS INDICATED ON THE DRAWINGS. SWITCHES SHALL BE QUICK -MAKE, QUICK -BREAK, HEAVY DUTY VISIBLE BLADE TYPE. ENCLOSURES SHALL BE NEMA 1 TYPE UNLESS OTHERWISE INDICATED ON THE DRAWINGS. FUSES SHALL BE DUAL ELEMENT - TIME DELAY TYPE. 2. ALL MOTORS OVER 1/8 HP SHALL BE PROVIDED WITH THERMAL OVERLOAD PROTECTION. OVERLOAD PROTECTION SHALL BE PROVIDED INTEGRAL WITH THE MOTOR WINDINGS AND/OR MOTOR OONTROLLER (PROVIDED BY OTHERS) UNLESS OTHERWISE INDICATED ON DRAWINGS. 3. ALL EQUIPMENT RATED LESS THAN 100A SHALL HAVE 60 DEGREE C MINIMUM TERMINATIONS. ALL EQUIPMENT RATED 100A OR OVER SHALL HAVE 75 DEGREE MINIMUM TERMINATIONS. H. LUMINAIRES AND LAMPS 1. ALL LUMINAIRES SHALL BE SPECIFIED ON THE LUMINAIRE SCHEDULE. 2. ALL FIXTURE / BALLAST 1 LAMP COMBINATIONS SHALL BE ENERGY SAVING TYPE. I. FIRE ALARM SYSTEM 1. A COMPLETE FIRE ALARM SYSTEM SHALL BE PROVIDED AS DESCRIBED ON THE DRAWINGS. ALL DEVICES, WIRING, BACKBOXES, PROGRAMMING, START-UP, INSTRUCTION AND TESTING REQUIRED FOR A COMPLETE OPERATING SYSTEM SHALL BE PROVIDED. 2. THE ELECTRICAL CONTRACTOR SHALL FURNISH SHOP DRAWINGS, COMPLETE WITH EQUIPMENT CUTS AND FLOOR PLANS (WITH WIRING INDICATED), AS WELL AS BATTERY CALCULATIONS, AND VOLTAGE DROP CALCULATIONS FOR REVIEW AND APPROVAL BY THE ARCHITECT, ENGINEER, AND ALL AUTHORITIES HAVING JURISDICTION. FLOOR PLAN DRAWINGS SHALL BE STAMPED BY A PROFESSIONAL ENGINEER RETAINED BY THE CONTRACTOR AND/OR SUPPLIER. NICET 4 CERTIFICATION AND STAMP IS ACCEPTABLE IF APPROVED BY THE AUTHORITY HAVING JURISDICTION. 3. THE ELECTRICAL CONTRACTOR SHALL FURNISH FIRE ALARM DRAWINGS, CALCULATIONS, AND EQUIPMENT INFORMATION FOR ALL REQUIRED LOCAL MUNICIPALITY, OR STATE PERMITS. THE ELECTRICAL CONTRACTOR SHALL ARRANGE AND COORDINATE ALL REQUIRED TESTING AND INSPECTIONS REQUIRED BY THE LOCAL MUNICIPALITY FIRE DEPARTMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE FIRE DEPARTMENT COSTS IN BID. 4. ALL HVAC UNITS OR GROUP OF HVAC UNITS WITH A COMMON PLENUM AND A DESIGN CAPACITY GREATER THAN 20M OEM SHALL AUTOMATICALLY SHUT DOWN ASSOCIATED HVAC UNIT OR UNITS. WHERE A DUCT SMOKE DETECTOR IS NOT VISIBLE OR ACCESSIBLE FROM THE FLOOR, REMOTE AUDIBLE/VISUAL ALARM INDICATOR/TEST SWITCHES SHALL BE PROVIDED IN AN APPROVED LOCATION, AT A HEIGHT ACCESSIBLE AND VISIBLE FROM THE FLOOR. HVAC DUCT DETECTORS SHALL BE CONNECTED TO A CENTRAL STATION MONITORING SYSTEM UNDER SEPARATE CONTRACT WITH THE OWNER. S. FIRE ALARM SIGNAL SHALL INITIATE THE FOLLOWING ACTIONS: a. CONTINUOUSLY OPERATE ALARM NOTIFICATION APPLIANCES. b. IDENTIFY ALARM AND SPECIFIC INITIATION DEVICE AT FIRE CONTROL PANEL. C. TRANSMIT ALARM TO LANDLORD SYSTEM. d. TRANSMIT ALARM SIGNAL TO REMOTE RECEIVING STATION. e. INTERRUPT TENANT SOUND SYSTEM. f. UNLOCK ELECTRIC DOORS IN EGRESS PATHS. g. RELEASE FIRE AND SMOKE DOORS HELD OPEN BY MAGNETIC DOOR HOLDERS. h. SHUT DOWN AIR HANDLING SYSTEMS. i. ACTIVATE EMERGENCY GAS AND HOOD EQUIPMENT SHUTOFFS. I. SWITCH HVAC EQUIPMENT CONTROLS TO FIRE ALARM MODE. 6. ALL FIRE ALARM VISIBLE DEVICES SHALL BE ADA COMPLIANT WITH A MINIMUM CANDELA RATING OF 75. CEILING MOUNTED DEVICES SHALL HAVE A RATING WITH THE LISTED REQUIREMENTS FOR A SPECIFIC CEILING HEIGHT. 7. ALL WALL MOUNTED STROBES, SPEAKER -STROBES, OR HORN STROBES SHALL BE MOUNTED SUCH THAT THE LENS IS NOT LESS THAN 80 INCHES AND NOT MORE THAN 96 INCHES ABOVE THE FINISHED FLOOR. 8. ALL AUDIBLE NOTIFICATION APPLIANCES SHALL BE SET TO ACHIEVE A SOUND PRESSURE AT LEAST 15dB ABOVE THE AVERAGE AMBIENT SOUND LEVEL. 9. ALL CABLES FOR THE FIRE ALARM SYSTEM SHALL BE RATED FOR THE INTENDED USE. 10. FIRE ALARM SYSTEM MONITORING SHALL BE BY OTHERS UNDER SEPARATE CONTRACT WITH THE OWNER. 11. PROVIDE A SEPARATE LINE ITEM COST FOR A (1), (3), (5) YEAR MAINTENANCE, TESTING AND MONITORING AGREEMENT. AGREEMENT TO INCLUDE MONITORING TO A UL LISTED CENTRAL STATION PER NFPA 72 REQUIREMENTS, ALL CODE REQUIRED TESTING OF THE FIRE ALARM SYSTEM PER NFPA 72 AND OBC (MONTHLY VISUAL INSPECTION SHALL BE BY THE ONNEB), CLEANING OF DEVICES SHALL BE DONE UPON SYSTEM REQUEST, AND ALL COST ASSOCIATED WITH MAINTENANCE OF THE SYSTEM SHALL BE PROVIDED (DUE TO DEFECTIVE EQUIPMENT ONLY). PROVIDE A YEARLY REPORT TO THE OWNER. 12. FIRE ALARM SYSTEM SHALL BE BY SIMPLEX, NOTIFIER, FCI, SIEMENS OR GAMEWELL. III. EXECUTION A. GENERAL MISCELLANEOUS 1. ALL CONDUIT RUN IN FINISHED AREAS SHALL BE CONCEALED. CONDUIT SMALLER THAN 3/4' SHALL MOT BE USED FOR ANY CIRCUIT HOMERUNS. 2. RACEWAYS EXPOSED TO DIFFERENT TEMPERATURES SHALL BE FILLED WITH AN APPROVED MATERIAL IN ACCORDANCE WITH ARTICLE 300.7 OF THE NATIONAL ELECTRICAL OODE. 3. HANGERS, SUPPORTS, OR FASTENINGS SHALL BE PROVIDED AT EACH ELBOW, AT THE ENDS OF STRAIGHT RUNS TERMINATING AT BOXES OR CABINETS, AND AT INTERMEDIATE POINTS AS REQUIRED BY CODE. CONDUITS OR BOXES SHALL NOT BE SUPPORTED BY CEILING SUPPORT WIRES OR OTHER CEILING SUPPORTING HARDWARE. 4. ACCESS PANELS SHALL BE PROVIDED FOR ALL JUNCTION BOXES AND PULL BOXES INSTALLED ABOVE DRYWALL CEILINGS, COORDINATE SIZE AND LOCATION WITH ARCHITECT. 5. FIXTURE SUPPORTS SHALL BE IN ACCORDANCE WITH ARTICLE 410-30 OF THE NATIONAL ELECTRICAL CODE, OR ANY LOCAL CODES WHICH MY APPLY. 6. PROVIDE PERMANENT NAMEPLATES WITH DESIGNATIONS FOR PANELBOARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS. 7. PROVIDE TYPEWRITTEN DIRECTORY CARDS WITH BRANCH CIRCUIT IDENTIFICATION FOR BRANCH CIRCUIT PANELBOARDS. PANELBDARDS, FEEDER DEVICES, DISTRIBUTION EQUIPMENT AND STARTERS SHALL BE FIELD MARKED TO WARN QUALIFIED PERSONS OF POTENTIAL ELECTRIC ABC FLASH HAZARDS IN ACCORDANCE WITH NEC 110.16. 8. INSTALL HANDLE GUARDS ON ALL BREWERS FOR NIGHT LIGHTING, EMERGENCY AND SIMILAR CIRCUITS. 9. THE ELECTRICAL CONTRACTOR SHALL BALANCE PANELBOARD LOADING TO WITHIN 10% ON EACH PHASE BASED ON INSTALLED CONDITIONS. LOAD BALANCING CIRCUIT CHANGES SHALL BE PERFORMED OUTSIDE THE NORMAL OCCUPANCY WORKING SCHEDULE AND AT A TIME DIRECTED BY LANDLORD. 10. THE FINAL LOCATIONS OF ALL EQUIPMENT, OUTLETS, ETC. SHALL BE SUBJECT TO REASONABLE CHANGES IN LOCATION UP TO THE TIME OF ROUGHING -IN, AT NO ADDITIONAL COST TO THE OWNER. 11. CONTACT ELECTRIC POWER COMPANY AND MANE NECESSARY ARRANGEMENTS FOR ELECTRIC SERVICE. 12. CONTACT TELEPHONE COMPANY AND MAKE NECESSARY ARRANGEMENTS FOR TELEPHONE SERVICE. 13. AT ALL TIMES KEEP PREMISES AND BUILDING IN A NEAT AND ORDERLY CONDITION, FOLLOWING OWNER'S INSTRUCTION IN REGARD TO STORING OF MATERIALS, PROTECTIVE MEASURES AND DISPOSING OF DEBRIS. 14. ALL SERVICE EQUIPMENT SHALL BE IDENTIFIED AS BEING SUITABLE FOR USE AS SERVICE EQUIPMENT. SERVICE EQUIPMENT SHALL BE FIELD MARKED WITH THE MAXIMUM AVAILABLE FAULT CURRENT AND THE DATE THE CALCULATION WAS PERFORMED. FIELD MARKING SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE INSTALLATION ENVIRONMENT. 15. RACEWAYS BELOW DRIVEWAYS, PARKING LOTS, AND ANY RACEWAYS INSTALLED BEGIN GRADE SHALL BE INSTALLED A MINIMUM OF 24' BELOW FINISHED GRADE PER NEC 300-5. B. GROUNDING 1. GROUND ALL CONDUITS, CABINETS, MOTORS, PANELS, AND OTHER EXPOSED NON -CURRENT CARRYING PARTS OF ELECTRICAL EQUIPMENT IN ACCORDANCE WITH NEC ARTICLE 250. 2. BOND METAL WATER PIPING AND OTHER METAL PIPING (INCLUDING GAS PIPING) AND EXPOSED STRUCTURAL METAL IN ACCORDANCE WITH NEC ARTICLE 250. 3. GROUNDING OF THE ELECTRICAL SYSTEM SHALL BE BY MEANS OF AN INSULATED GROUNDING CONDUCTOR INSTALLED WITH ALL FEEDERS AND BRANCH CIRCUIT CONDUCTORS IN ALL CONDUITS. FIRE ALARM NOTES 1. PRINCIPAL OCCJPANCY CLASSIFICATION IS GROUP M. 2. SPACE IS PROVIDED WITH FULL SPRINKLER COVERAGE. 3. OCCUPANT LOAD IS LESS THAN 500. 4. THE LANDLORD DOES REQUIRE ALL TENANTS TO INSTALL A FIRE ALARM SYSTEM MONITORED BY THE LANDLORD SYSTEM. 5. A FIRE ALARM SYSTEM IS REQUIRED. CURRAN ARCHITECTURE 5719 LAWTON LOOP E. DR. #212 INDIANAPOLIS, IN 46216 O c 317.288 .0681 F :: 317.288.0753 DRAWN BY: JTK CHECKED BY: WR OTIE/S ENGINEERING 25760 First Street Cleveland, OH 44145 P 440 8712410 F 440 871 7954 tesengineering.com NGEM T N 767i�_ %p STATE OF i•�� i SS//DON A LI\���Y\ II III THIS OMWING AND THE IDEAS DESIGNS AND CONCEPTS CONTAINED HEREIN ARE THE EXCLUSIVE INTELLECTUAL PROPERTY OF CURRAN ARCHITECTURE, AND ARE NOT TO BE USED OR REPRODUCED, WHOLE OR IN PART, WITHOUT THE WRITTEN CONSENT OF CURRAN ARCHITECTURE. © wv T201¢aRVN'PouTFCme= WESTON POINTE RESTAURANT WESTON POINTE DRIVE NORTH MICHIGAN ROAD CARMEL, INDIANA ELECTRICAL LEGENDS, ABBREVIATIONS & SPECIFICATIONS CARMEL RESUBM PERMIT SET ADDENDUM 1 ADDENDUM 2 PERMIT SET 170026 E=0.2